Search NASA⌕ Search

SEARCH · Search NASA

Results for “Curtailment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Too Much of a Good Thing? Global Trends in the Curtailment of Solar PV

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. However, PV curtailment is increasing as PV composes greater shares of grid capacity. In this paper, we present a novel synthesis of curtailment in four key countries: Chile, China, Germany, and the United States. We find that about 6.5 million MWh of PV output was curtailed in these countries in 2018. We find that: Policy and grid planning practices influence where, when, and how much PV is curtailed; Some PV curtailment is attributable to limited transmission capacity connecting remote solar resources to load centers; PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. We discuss available measures to reduce PV curtailment as well as increasing PV curtailment in the contexts of evolving grids and energy technologies.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Impact of Thermal Plant Operational Flexibility on VRE Curtailment: The Curtailment Paradox

This presentation provides an overview of a previously published paper in Joule "The curtailment paradox in the transition to high solar power systems." The adoption of PV and battery storage has accelerated globally in recent years, driven by rapid cost declines. A corresponding increase in curtailment is anticipated as PV growth continues. This study explores the effect of system flexibility options on curtailment across increasing PV penetration levels. Results highlight a paradox where thermal generator flexibility matters most only at mid-PV penetration levels (25%-40%), and a misalignment exists where PV provides system value by providing operating reserves without sufficient opportunity for monetary compensation.

capacity expansion modeling↗

Activity-based Informed Curtailment: Using Acoustics to Design and Validate Smart Curtailment to Reduce Risk to Bats at Wind Farms

Rapid expansion of renewable energy infrastructure is a key part of any global strategy to reduce the pace and severity of anthropogenic climate change, although the potential impacts of renewable energy infrastructure on wildlife are also becoming increasingly apparent. Bats appear vulnerable to population-level impacts from the cumulative effect of turbine-related fatalities at commercial wind energy facilities in North America, particularly as the industry continues to expand to meet renewable energy generation targets. Turbine curtailment is the most widely used and consistently effective method to reduce bat fatality rates and involves pitching turbine blades parallel to prevailing winds to restrict turbine rotation when turbines would otherwise be operating and capable of producing power. Recognizing the need to expand the wind industry while managing risk to bats highlights the need to understand and manage turbine-related impacts to bats more aggressively and strategically than the current use of blanket curtailment allows.

17 WIND ENERGY↗

Bat Smart Curtailment: Efficacy and Operational Testing

Curtailment, or blanket curtailment, is a leading method to mitigate the impacts to bats from operating wind turbines. Although this strategy results in considerable decreases in bat fatalities, it also results in decreased energy production. In 2019, Natural Power was awarded funding by the Department of Energy to assess the readiness of the informed smart curtailment technology, EchoSense (formerly referred to as Detection and Active Response Curtailment, [DARC]). The research undertaken by this project expands the understanding of alternative methods, known as smart curtailment, to maintain a reduction in bat fatalities while simultaneously recovering lost energy associated with blanket curtailment. The overall project was composed of three major tasks; Task 1 was focused on cybersecurity compliance of the EchoSense system in accordance with the North American Electric Reliability Corporation Critical Infrastructure Protection (“NERC CIP”) standards, Task 2 assessed the mechanical loads exerted on turbines when operating under a smart curtailment regime, and Task 3 assessed the efficacy of the EchoSense system at an operational wind farm. Regarding Task 1, an external review by the National Renewable Energy Laboratory determined that the EchoSense system did not create any new cybersecurity weaknesses and was compliant with the NERC CIP standards. As a result of this process, Natural Power developed some best practices (10.1) for wind- wildlife technology developers. In conjunction with the National Renewable Energy Laboratory, the results (10.2) of the loads testing demonstrated that the periodic curtailment and release of turbines by the EchoSense system did not have any detrimental impact on the mechanical components of a wind turbine (Task 2). During the late summer to fall of 2020 and 2021, Natural Power demonstrated that the use of the EchoSense smart curtailment system resulted in no significant difference in bat fatalities compared to blanket curtailment with cut-in speeds at 6.9 m/s (2020) and 5.0 m/s (2021) while resulting in a significant difference in decreased lost energy (Task 3). This translates to an average of 41% (2020) and 56% (2021) reduction in per turbine energy loss compared to blanket curtailment. The reduction in energy loss that would have been achieved by EchoSense curtailment compared to blanket curtailment, if applied across all 69 turbines, is roughly equivalent to having an additional turbine on site. These results are notable for finding a balance between the environmental impact of wind energy and the economic feasibility in energy production associated with mitigating that impact. https://www.naturalpower.com/us/expertise/service/engineering-operations/echosense

17 WIND ENERGY↗

Solar PV Curtailment in Changing Grid and Technological Contexts: Preprint

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. At increasing levels of PV penetration situations arise where PV is curtailed, either because of local supply/demand imbalances or to maintain system flexibility. In 2018, we estimate that about 6.5 million MWh of PV output was curtailed in four key countries: Chile, China, Germany, and the United States. We find that PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. Similar to the case of wind, some PV curtailment is attributable to limited transmission capacity connecting sparsely populated solar-heavy regions to load centers.Grid policies generally seek to minimize curtailment because it is viewed as an economic and environmental loss. However, we argue that changing grid and technological contexts warrant new thinking on PV curtailment. In the grid context, as grids integrate more PV and other renewable energy generation, seeking an optimal level of accepted curtailment becomes more efficient than preventing it. In the technological context, emerging technologies such as advanced inverters and low-cost battery storage are making PV systems more flexible. With flexible PV, grid operators can use withheld PV output to provide various non-generation grid services. This withheld PV output is a form of curtailment under prevailing definitions of the term. Hence, policies that aim to minimize curtailment may undercut the ability of grid operators to fully use the emerging capabilities of flexible PV systems. We argue that the changing grid and technological contexts require a re-examination of the curtailment paradigm. We argue that PV output that is withheld to provide grid services is fundamentally different from output that goes unused in response to system constraints. As a result, we propose a more exclusive definition of curtailment as unused PV output rather than the more expansive conventional definition as any reduction in system output from its technical potential. The terminological distinction is more than a question of semantics. Facilitating grid services by withholding PV output may increase the potential value of flexible PV systems to the grid. This shift in thinking may allow grid operators and policymakers to think in terms of PV curtailment management rather than minimization. Effective curtailment management may include policies that increase PV system dispatchability, alternative PV compensation schemes that decouple generator revenue from system output, and policies to increase grid flexibility.

Chile↗

Analysis of curtailment at The Geysers geothermal Field, California

Geothermal energy has traditionally been viewed as a baseload energy source, but the rapid growth of intermittent renewable energy has led to a need for more flexibility in power generation to avoid mandatory curtailment imposed by grid operators. This study of curtailment at The Geysers provides insights into the magnitude, duration, frequency, temporal and spatial distribution, and potential causes of curtailment events between 2013 and 2018. Annual levels of curtailment range during this period from 9 to 47 GW h, representing 0.15 to 0.81 % of the net generation. Most curtailments occurred at the power plants connected to a lower capacity transmission line and may result from transmission constriction. There is a clear link between negative pricing and economic curtailment, especially when solar production is higher. Economic curtailment events tend to be only a few hours and vary in magnitude up to almost 300 MW, whereas transmission-related curtailment events can be up to several weeks in duration. It is likely that curtailment of geothermal power will be an increasing concern, and could be mitigated by flexible generation strategies and increases in energy storage. It is critical to know the nature of curtailment events so that flexible generation options can be assessed properly.

15 GEOTHERMAL ENERGY↗

Developing and Evaluating a Smart Curtailment Strategy Integrated with a Wind Turbine Manufacturer Platform

The Renewable Energy Wildlife Institute lead a team of scientists, wind developers, and turbine manufacturers in a study to develop and test a “smart curtailment” system intended to help reduce bat collisions with wind turbines. The Vestas Bat Protection System (VBPS) is a newly developed software module within the Supervisory Control and Data Acquisition (SCADA) system of Vestas turbines. The VBPS combines data from commercially available environmental sensors and the turbine’s built-in sensors with the Vestas SCADA system. VBPS is designed to receive environmental data from sensors on the turbine such as temperature, wind speed, wind direction, time of day, and time of year, relays that information to the SCADA system to determine whether to execute turbine curtailments at any given time. The goals of this study were to 1) develop a bat fatality risk model based on bat activity data and environmental data collected in year 1, and to 2) evaluate the VBPS, using the bat fatality risk model to implement curtailment, in comparison to “blanket curtailment” (turbines curtailed when wind speed is below 5.0 meters per second (m/s)) and “control” (normally operating, feathered below 3.0 m/s) turbines in year 2. The field study took place at a wind energy facility in Iowa during the fall bat migration seasons (July – October) in 2021 and 2022. For VBPS to succeed as a viable strategy for the minimization of bat fatalities, it should meet or exceed the performance of blanket curtailment. Specifically, the VBPS should meet the following performance targets to demonstrate whether it an effective, practical risk reduction measure: (1) Turbines operating VBPS should have equal or fewer bat fatalities compared to turbines operating with blanket curtailment, and significantly fewer bat fatalities compared to control turbines; and (2) Turbines operating VBPS should have greater power production compared to turbines operating with blanket curtailment. The study was completed in accordance with the Statement of Project Objectives and within the terms of the Budget Justification. This Final Report describes the progress, challenges, and outcomes of the study.

17 WIND ENERGY↗

A decade of curtailment studies demonstrates a consistent and effective strategy to reduce bat fatalities at wind turbines in North America

Abstract There is a rapid, global push for wind energy installation. However, large numbers of bats are killed by turbines each year, raising concerns about the impacts of wind energy expansion on bat populations. Preventing turbine blades from spinning at low wind speeds, referred to as curtailment, is a method to reduce bat fatalities, but drawing consistent inference across studies has been challenging. We compiled publicly available studies that evaluated curtailment at six wind energy facilities in North America across 10 years. We used meta‐regression of 29 implemented treatments to determine fatality reduction efficacy as well as sources of variation influencing efficacy. We also estimated species‐specific fatality reduction for three species that comprise most fatalities in North America: hoary bat ( Lasiurus cinereus ), eastern red bat ( Lasiurus borealis ) and silver‐haired bat ( Lasionycteris noctivagans ). We found that curtailment reduced total bat fatalities by 33% with every 1.0 ms −1 increase in curtailment wind speed. Estimates of the efficacy for the three target species were similar (hoary bats: 28% per ms −1 , 95% CI: 0.4%–48%, eastern red bats: 32% per ms −1 , 95% CI: 13%–47% and silver‐haired bats: 32% per ms −1 , 95% CI: 3%–53%). Across multiple facilities and years, a 5.0 ms −1 cut‐in speed was estimated to reduce total bat fatalities by an average of 62% (95% CI: 54%–69%). Mortality reductions at individual facilities in any given year were estimated to fall between 33%–79% (95% prediction interval). Inter‐annual differences rather than inter‐site or turbine characteristics accounted for most of the variation in efficacy rates. Species‐specific average mortality reduction at 5.0 ms −1 curtailment wind speed was 48% (95% CI: 24%–64%) for hoary bats, 61% (95% CI: 42%–74%) for eastern red bats and 52% (95% CI: 30%–66%) for silver‐haired bats. Practical implication . curtailment reduced bat mortality at wind turbines in this North American study. Efficacy increased proportionally as curtailment speed is raised, and patterns and rates of efficacy were similar across species. This indicates that curtailment is an effective strategy to reduce bat fatalities at wind energy facilities, but exploration of further refinements could both minimize bat mortality and maximize energy production.

17 WIND ENERGY↗

Evaluation of the Turbine Integrated Mortality Reduction (TIMR SM ) Technology as a Smart Curtailment Approach (Final Summary Report)

Wind energy is a crucial technology for achieving net-zero emissions by 2050. However, the growth and deployment of wind energy in North America have led to the deaths of many bat species due to operating wind turbines. Hundreds of thousands of bats are estimated to die at wind turbines annually in North America. Operational minimization, which includes feathering turbine blades and curtailment, has been documented to reduce bat fatality effectively. Curtailment refers to altering turbine operation based on wind speed, time of year, temperature, sensors, and activity models. However, when turbines are curtailed, they do not generate power, resulting in energy loss and revenue for wind energy facilities. The Electric Power Research Institute (EPRI) funded the development of Turbine Integrated Mortality Reduction (TIM SM ) Technology, which curtails turbine operation when bats are detected. The initial TIMR system research showed promising results, with an 85% reduction in overall bat fatalities and a 91% reduction for the little brown bat. However, these results were based on a single site during one fall season, and it was unclear if similar results could be replicated at other wind energy facilities. This research aimed to validate the TIMR system results from the prior field study at a second site in the U.S., estimate the power production and reduction in bat mortality at turbines with installed TIMR systems relative to blanket curtailment and fully operational turbines, test the TIMR system in two calendar years and during the summer and fall periods, and evaluate the operational and commercial characteristics of the TIMR system for potential wind industry adoption. The study was conducted at a 500.9-MW wind energy facility in southeast Adair County, Iowa. Three experimental treatments were involved in this randomized block design study: TIMR, Curtailment at 5.0 m/s, and Normal Operation. In 2021, three treatments were used at 18 turbines, expanding to four treatments across 36 turbines in 2022. The TIMR system worked as designed throughout the entire study; however, because of unexpected wind turbine operational challenges in 2021, there was not sufficient sample size to evaluate the treatment differences. In 2022, there were significant differences in fatality levels between treatment types and normal operating turbines. Curtailment at 5.0 m/s reduced fatalities by 30.8% compared to normal operations, and TIMR decreased fatalities by 48.6% compared to normal operations. Two different methods were used to evaluate the differences in energy loss for each treatment. The TIMR system resulted in 1.3% to 1.6 % annual energy loss in 2021 and 1.0% to 1.2 % in 2022. The Curtailment at 5.0 m/s resulted in 0.6% to 0.8 % annual energy loss in 2021 and 0.5% to 0.6 % in 2022. The project achieved all the stated objectives and demonstrated that TIMR is an effective technology that balances bat fatality reduction with energy generation. The results will support the deployment of TIMR and other acoustic sensor-based technologies. The research provides valuable insights into the impact of different treatments on fatality rates and energy outputs, contributing to the ongoing efforts to mitigate the environmental impact of wind energy.

17 WIND ENERGY↗

National-scale impacts on wind energy production under curtailment scenarios to reduce bat fatalities

Wind energy often plays a major role in meeting renewable energy policy objectives; however, increased deployment can raise concerns regarding the impacts of wind plants on certain wildlife. Particularly, estimates suggest hundreds of thousands of bat fatalities occur annually at wind plants across North America, with potential implications for the viability of several bat species. One approach to reducing bat fatalities is shutting down (or curtailing) turbines when bats are most at risk, such as at night during relatively low wind speed periods throughout summer and early autumn. While curtailment has consistently been shown to reduce bat fatalities, the lost power production reduces revenues for wind plants. This study conducted simulations with a range of curtailment scenarios across the contiguous United States to examine sensitivities of annual energy production (AEP) loss and potential impacts on economic metrics for future wind energy deployment. We found that AEP reduction can vary across the country from less than 1% to more than 10% for different curtailment scenarios. From an estimated 2891 gigawatts (GW) of simulated economically viable wind capacity (measured by a positive net present value), we found the mid curtailment scenario (6.0 m/s wind speed cut-in from July 1 through October 31) reduced the quantity of economic wind capacity by 274 GW or 9.5%. Our results indicate that high levels of curtailment could substantially reduce the future footprint of financially viable wind energy. In this context, future work that illuminates cost-effective strategies to minimize curtailment while reducing bat fatalities would be of value.

17 WIND ENERGY↗

The Solar Curtailment Paradox

This presentation summarizes work recently published in a Joule article, "The Curtailment Paradox in the Transition to High Solar Power Systems." Rising penetrations of variable renewable energy (VRE) in power systems are expected to increase the curtailment of these resources because of oversupply and operational constraints. We evaluate the effect on curtailment from various flexibility approaches, including storage, thermal generator flexibility, operating reserve eligibility rules, transmission constraints, and temporal resolution, by using a highly resolved realistic system. Results reveal two aspects of a curtailment paradox as the system evolves to higher solar penetration levels. First, thermal generator parameters, especially in restricting minimum operating levels and ramp rates, affect VRE curtailment more in mid-PV penetration levels (~25%–40%) but much less at lower (~20%) or higher (~45%) PV penetration levels. Second, although allowing VRE and storage to provide operating reserve results in significant operating costs and curtailment benefits, the price suppression effect from these resources reduces incentives for PV to provide operating reserves with curtailed energy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Enabling Fairness in Distributed PV Curtailment for Voltage Regulation: A Comparative Analysis

The growing adoption of photovoltaic systems in power distribution networks has yielded numerous advantages, but it has also introduced challenges, particularly in managing overvoltage issues. Uncoordinated photovoltaic integration can lead to voltage rise beyond acceptable levels. Curtailing active power is an effective method for addressing overvoltage issues in power distribution systems. Nevertheless, it is essential to distribute the curtailment fairly among the resources to maintain fairness and achieve a well-balanced utilization of renewable energy. This paper presents a comparative study of different fairness schemes for active power curtailment in photovoltaic integration systems. Three different curtailment methods are selected for demonstration: i) proportional, ii) egalitarian, and iii) financial. The study involves evaluating the curtailment schemes based on their ability to distribute the curtailed power among the photovoltaic systems in a justifiable manner, focusing on their formulation and distributed solution. A detailed performance comparison is carried out to highlight the cost of catering for fairness schemes in photovoltaic curtailment using relevant metrics, where simulations are carried out using a modified IEEE 123-bus test case.

Mukherjee, Monish↗

Overvoltage Prevention and Curtailment Reduction Using Adaptive Droop-Based Supplementary Control in Smart Inverters

Recent developments in the renewable energy sector have seen an unprecedented growth in residential photovoltaic (PV) installations. However, high PV penetration levels often lead to overvoltage problems in low-voltage (LV) distribution feeders. Smart inverter control such as active power curtailment (APC)-based overvoltage control can be implemented to overcome these challenges. The APC technique utilizes a constant droop-based approach which curtails power rigidly, which can lead to significant energy curtailment in the LV distribution feeders. In this paper, different variations of the APC technique with linear, quadratic, and exponential droops have been analyzed from the point-of-view of energy curtailment for a LV distribution network in North America. Further, a combinatorial approach using various droop-based APC methods in conjunction with adaptive dynamic programming (ADP) as a supplementary control scheme has also been proposed. The proposed approach minimizes energy curtailment in the LV distribution network by adjusting the droop gains. Simulation results depict that ADP in conjunction with exponential droop reduces the energy curtailment to approximately 50% compared to using the standard linear droop.

42 ENGINEERING↗

Evaluating the Curtailment Risk of Non-Firm Utility-Scale Solar Photovoltaic Plants under a Novel Last-In First-Out Principle of Access Interconnection Agreement

With the increasing share of distributed energy resources on the electric grid, utility companies are facing significant decisions about infrastructure upgrades. An alternative to extensive and capital-intensive upgrades is to offer non-firm interconnection opportunities to distributed generators, via a coordinated operation of utility scale resources. This paper introduces a novel flexible interconnection option based on the last-in, first-out principles of access aimed at minimizing the unnecessary non-firm generation energy curtailment by balancing access rights and contribution to thermal overloads. Although we focus on solar photovoltaic (PV) plants in this work, the introduced flexible interconnection option applies to any distributed generation technology. The curtailment risk of individual non-firm PV units is evaluated across a range of PV penetration levels in a yearlong quasi-static time-series simulation on a real-world feeder. The results show the importance of the size of the curtailment zone in the curtailment risk distribution among flexible generation units as well as that of the “access right” defined by the order in which PV units connect to the grid. Case study results reveal that, with a proper selection of curtailment radius, utilities can reduce the total curtailment of flexible PV resources by up to more than 45%. Findings show that non-firm PV generators can effectively avoid all thermal limit-related upgrade costs.

14 SOLAR ENERGY↗

Ultrasonic deterrents provide no additional benefit over curtailment in reducing bat fatalities at an Ohio wind energy facility

Wind energy is important for achieving net-zero greenhouse gas emissions but also contributes to global bat mortality. Current strategies to minimize bat mortality due to collision with wind-turbine blades fall broadly into two categories: curtailment (limiting turbine operation during high-risk periods) and deterrence (discouraging bat activity near turbines). Recently, there has been interest in combining these strategies to achieve greater reductions in bat fatalities than either strategy might achieve in isolation. To investigate the effectiveness of combining curtailment with ultrasonic deterrent minimization strategies, we deployed six ultrasonic deterrents at nacelle height on 16 experimental turbines at Avangrid Renewables’ Blue Creek Wind Energy Facility. We rotated between four conditions (normal operations, curtailment only, deterrent only, curtailment and deterrent) randomly assigned to four wind turbines each night between 15 June and 3 October 2017. We found that bat mortality at wind turbines was independent of wind speed. The effectiveness of ultrasonic acoustic deterrents varied between high-frequency-calling species (eastern red bats) and low-frequency-calling species (hoary bats, silver-haired bats, and big brown bats). When deterrents were active, mortality was twice as high for eastern red bats compared to the control. Conversely, deterrents had a weak dampening effect on bat mortality for low-frequency species. We found no additive effects on mortality reduction for turbines operating both curtailment and deterrents compared to either approach in isolation. Our findings suggest that ultrasonic acoustic deterrents may not be effective for both high and low frequency echolocating bats. The increase in fatalities of eastern red bats is alarming and underscores the importance of considering site- and species-specific effects of minimization solutions.

60 APPLIED LIFE SCIENCES↗

Estimation of solar photovoltaic energy curtailment due to volt–watt control

The widespread deployment of autonomous inverter‐based solutions for mitigating voltage and frequency excursions caused by high‐penetration photovoltaic (PV) systems has drawn increased attention due to their potential impact on PV production. It is now important to quantify the amount of solar energy curtailed as a result of the activation of inverter‐based grid support functions (GSFs). This study proposes a methodology for estimating the impact of volt–watt on customer PV energy curtailment using smart meter voltage data. This method estimates maximum possible curtailment for a given volt–watt curve based on the customer smart meter voltage during the time period of interest. This study compares the proposed methodology with field measurements using irradiance and customer inverter data from Hawaii as well as with results from a previous simulation‐driven study on the impact of advanced inverter GSF activation on PV energy curtailment. Results show that the proposed method for estimating lost PV production caused by volt–watt control aligns reasonably well with field measurements and computer simulations for hundreds of customers. The proposed method could be used to estimate customer energy curtailment, which could inform future compensation mechanisms for utilities leveraging customer‐sited resources to mitigate high voltage and defer infrastructure upgrades.

Emmanuel, Michael↗