Search NASA⌕ Search

SEARCH · Search NASA

Results for “DUOPLASMATRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Design and fabrication of a duoplasmatron extraction geometry and LEBT for the LANSCE H{sup +} RFQ project

The 750-keV H{sup +} Cockcroft-Walton at LANSCE will be replaced with a recently fabricated 4-rod Radio Frequency Quadrupole (RFQ) with injection energy of 35 keV. The existing duoplasmatron source extraction optics need to be modified to produce up to 35 mA of H{sup +} current with an emittance <0.02 π-cm-mrad (rms, norm) for injection into the RFQ. Parts for the new source have been fabricated and assembly is in process. We will use the existing duoplasmatron source with a newly designed extraction system and low energy beam transport (LEBT) for beam injection into the RFQ. In addition to source modifications, we need a new LEBT for transport and matching into the RFQ. The LEBT uses two magnetic solenoids with enough drift space between them to accommodate diagnostics and a beam deflector. The LEBT is designed to work over a range of space-charge neutralized currents and emittances. The LEBT is optimized in the sense that it minimizes the beam size in both solenoids for a point design of a given neutralized current and emittance. Special attention has been given to estimating emittance growth due to source extraction optics and solenoid aberrations. Examples of source-to-RFQ matching and emittance growth (due to both non-linear space charge and solenoid aberrations) are presented over a range of currents and emittances about the design point. A mechanical layout drawing will be presented along with the status of the source and LEBT, design, and fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface modification of ferritic steels using MEVVA and duoplasmatron ion sources

Metal Vapor Vacuum Arc (MEVVA) ion source (IS) is a unique tool for production of high intensity metal ion beam that can be used for material surface modification. From the other hand, the duoplasmatron ion source provides the high intensity gas ion beams. The MEVVA and duoplasmatron IS developed in Institute for Theoretical and Experimental Physics were used for the reactor steel surface modification experiments. Response of ferritic-martensitic steel specimens on titanium and nitrogen ions implantation and consequent vacuum annealing was investigated. Increase in microhardness of near surface region of irradiated specimens was observed. Local chemical analysis shows atom mixing and redistribution in the implanted layer followed with formation of ultrafine precipitates after annealing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation, Design, Construction of Duoplasmatron and Diagnostic Neutral Beam System for Alborz Tokamak

Diagnostic Neutral Beam (DNB) has been used for measuring plasma parameters of tokamaks such as ion and electron temperature, safety factor, impurity concentration and etc. Ion source and electrical power supply specification are the main part of DNB. Arc discharge current value is affected by filament current and anode voltage. Beam current changes with arc current signal in our experiment that agree with theoretical relations. Sixty milli-ampere (60 mA) pulse beam current is because of arc current of about 40 A and extraction voltage of about 20 kV. The increase of beam current with arc current has been reported experimentally and effect of arc current on beam current has been investigated for several high extraction voltages. Optimum condition, which means having a telescopic beam (minimum divergence) for specific parameters of duoplasmatron, has been simulated and verified with experimental test. The best extraction voltage for these parameters has been found to be about 16-kV. The ratio of the perpendicular velocity to parallel velocity has been calculated to be about 0.012. It has been shown experimentally with optical emission spectroscopy that increase in arc current and magnetic current increase proton content of beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental optimization of beam quality extracted from a duoplasmatron proton ion source

The LANSCE accelerator facility operates with two independent ion injectors for H⁺ and H⁻ particle beams. The H⁺ ion beam is formed using a duoplasmatron source followed by a 750 keV Cockroft-Walton accelerating column. Formation of an optimal plasma meniscus is an important feature for minimizing beam emittance, and maximizing beam brightness. A series of experiments were performed to find the optimal combination of extraction voltage and extracted current for the H⁺ beam. Measurements yielded the best ratio of beam perveance to Child–Langmuir perveance of 0.52 for maximizing beam brightness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Optimization of the IOTA Duoplasmatron Proton Source

We present results from online optimization studies of a duoplasmatron ion source designed to produce 50~keV protons for acceleration to 2.5~MeV and subsequent injection into the Integrable Optics Test Accelerator (IOTA) at Fermilab. Using a Bayesian exploration technique, we developed multi-parameter models of the source s proton current and employed these models to optimize its performance. Depending on the spectrometer configuration used to isolate the proton beam and the chosen optimization objective, we identified three candidate operating points, achieving normalized 50~\% emittances between 0.57 and 1.3~\textmu m and a maximum proton current of $14.5 \pm 0.6$~mA.

Banerjee, Nilanjan [Fermilab] (ORCID:0000000344660↗

Commissioning of Phase 1 of the LANL RFQ Test Stand - Beam Characterization

A series of numerical start-to-end simulations of Phase 1 of the 750 keV RFQ Test Stand which includes the ion source (H+ duoplasmatron), a 1-Solenoid LEBT, an emittance scan station and a Faraday cup were performed to find a mechanism for the characterization of the proton beam extracted from the duoplasmatron.

43 PARTICLE ACCELERATORS↗

A Tandetron as proton injector for the eye tumor therapy in Berlin

The therapy of eye tumors with fast protons is an excellent tool giving very high local control rates. At the Helmholtz-Zentrum Berlin (HZB) almost 1800 patients were treated since 1998. A 2 MV Tandetron was installed as injector for the k = 132 HZB cyclotron. Using the standard 358 duoplasmatron ion source with direct extraction of negative hydrogen ions an extremely stable proton beam can be delivered, both on the short-term and the long-term scale. The hair-needle filaments made from thoriated tungsten wires have safe operation times of more than 1000 h.

43 PARTICLE ACCELERATORS↗

Electrostatic Matching of a High Current Proton Beam to a RFQ

In order to demonstrate the operation of a prototype DWA (dielectric wall accelerator), it was necessary to modify the LEBT of a commercially procured proton RFQ (Radio Frequency Quadrupole) injector linac. The relatively high output current (35 mA) of the duoplasmatron ion source at the low injection energy of 35 keV to the RFQ presented a matching problem in the beam transport due to the high space charge, the fixed transport length, and the small beam size required at the RFQ. In addition, only the use of electrostatic lenses was considered in order to minimize the size of the system. The standard AccSys design using one decel-accel einzel lens proved to be insufficient, so three new solutions were proposed, each using a pair of decelerating einzel lenses. The tool used to optimize these designs was a newly developed feature of the program IGUN. The RFQ acceptance ellipse is plotted on top of the phase space data of the transport calculation together with an ellipse with the same Twiss parameters which just encloses all the trajectories. The quality of matching is then given as the ratio of the areas of these two ellipses, making optimization easy. This paper will present the results of this optimization and the performance of the actual equipment built and tested.

43 PARTICLE ACCELERATORS↗

Test results of the proton injector of the Proton Engineering Frontier Project accelerator

One of the goals of the Proton Engineering Frontier Project (PEFP) is to develop a 100 MeV proton accelerator. As a low energy part, a 20 MeV proton linac has been developed and tested. The 20 MeV accelerator consists of a 50 keV proton injector, a 3 MeV radio frequency quadrupole, and a 20 MeV drift tube linac. The proton injector includes a duoplasmatron type ion source and a low energy beam transport. After a preliminary test with 1 mA peak current of the 20 MeV accelerator, the proton injector was modified with the goal of increasing the 20 MeV beam current up to 20 mA peak value. The modifications include the reduction of the proton injector length, installation of a beam current monitor, and electron trap and supplement of the solenoid and steering magnets. In this paper, the modifications of the PEFP proton injector are described and initial test results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion source development for various applications in Korea (invited) (abstract)

Ion source development in Korea has been related with various applications from accelerator to nanotechnology. Conventional ion sources such as Duoplasmatron and PIG ion sources were developed for high power proton accelerator and small cyclotron accelerators. To improve lifetime of the high current proton ion source, helicon plasma ion sources were developed with external rf antenna and applied for neutron generation in drive-in-target configuration. Negative hydrogen ion sources were also developed for tandem and cyclotron accelerators by using both rf and filament discharges. Large-area high-current ion sources for the KSTAR NBI system were developed and successfully tested for long-pulse operation of up to 300 s. Several broad beam ion sources for industrial applications such as ion implantation and surface treatment were also developed by using arc, rf, and microwave discharges. Recently, ion source applications become diversified to the area of nano- and biotechnologies. For example, C60 ion source was developed for the use of bioapplications in nanometer scale. For focused ion beam as a nanofabrication tool, liquid metal ion sources were improved and a novel plasma ion source was developed by utilizing localized sheath discharges. Research and development activities of these ion sources will be discussed with short description of appropriate applications.

43 PARTICLE ACCELERATORS↗

Status of ion sources at National Institute of Radiological Sciences

The National Institute of Radiological Sciences (NIRS) maintains various ion accelerators in order to study the effects of radiation of the human body and medical uses of radiation. Two electrostatic tandem accelerators and three cyclotrons delivered by commercial companies have offered various life science tools; these include proton-induced x-ray emission analysis (PIXE), micro beam irradiation, neutron exposure, and radioisotope tracers and probes. A duoplasmatron, a multicusp ion source, a penning ion source (PIG), and an electron cyclotron resonance ion source (ECRIS) are in operation for these purposes. The Heavy-Ion Medical Accelerator in Chiba (HIMAC) is an accelerator complex for heavy-ion radiotherapy, fully developed by NIRS. HIMAC is utilized not only for daily treatment with the carbon beam but also for fundamental experiments. Several ECRISs and a PIG at HIMAC satisfy various research and clinical requirements.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of the IOTA Proton Source [Slides]

Integral-Optics Test Accelerator (IOTA) • Formed from the High Intensity Neutrino Source (HINS) • Goals – integrable optics with non-linear magnets and with electron lenses – optical stochastic cooling of particle beams – innovative emittance exchange • Storage ring – 39m in circumference – protons and ions • Focus on injection into RFQ – Duoplasmatron – Nickel filament.

43 PARTICLE ACCELERATORS↗

Side extraction duoPIGatron-type ion source

We have designed and constructed a compact duoPIGatron-type ion source, for possible use in ion implanters, in which ions are extracted from a side aperture in contrast to conventional duoPIGatron sources with axial ion extraction. The size of the side extraction aperture is 1x40 mm{sup 2}. The ion source was developed to study physical and technological aspects relevant to an industrial ion source. The side extraction duoPIGatron has a stable arc, uniformly bright illumination, and dense plasma. The present work describes some operating parameters of the ion source using argon and BF{sub 3}. Total unanalyzed beam currents were 40 mA with Ar at an arc current of 7 A and 13 mA with BF{sub 3} gas at an arc current of 9 A.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗