Search NASA⌕ Search

SEARCH · Search NASA

Results for “Deployable heat shields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

FY22 Year End Report of Delivery Environments Predictive Capabilities Use in Analysis of SRP Programs

As was established in a previous milestone report for FY20, W-13 continues to be tasked with analyses that require knowledge of in-flight environments and require an in-house capability to generate such environments. To this end, FY21 work included obtaining and benchmarking the use of such tools for an in-house capability. With these tools available for analysis tasks, FY22 work has been to continue the development of analysis for Responsive Development Experiment (ReDX) flights in the Stockpile Responsiveness Program (SRP). While no flights were executed in FY22 that leveraged internal flight analysis., this report shows that both CBAERO and TAOS were used in W-13 under the Delivery Environments Program for the FY22 milestone in order to predict the flight environments of ReDX flight 3 and determine preliminary environments of the Calypso flight vehicle which includes a deployable heat shield.

42 ENGINEERING↗

THERMAL PROPERTIES OF DOUBLE-ALUMINIZED KAPTON AT LOW TEMPERATURES

Double-aluminized kapton (DAK) is commonly used in multi-layer insulation blankets in cryogenic systems. NASA plans to use individual DAK sheets in lightweight deployable shields for satellites carrying instruments. A set of these shields will reflect away thermal radiation from the sun, the earth, and the instrument's warm side and allow the instrument's cold side to radiate its own heat to deep space. In order to optimally design such a shield system, it is important to understand the thermal characteristics of DAK down to low temperatures. We describe experiments which measured the thermal conductivity and electrical resistivity down to 4 Kelvin and the emissivity down to 10 Kelvin.

36 MATERIALS SCIENCE↗

The detector calibration system for the CUORE cryogenic bolometer array

The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale cryogenic experiment designed to search for neutrinoless double-beta decay of 130 Te and other rare events. The CUORE detector consists of 988 TeO 2 bolometers operated underground at 10 mK in a dilution refrigerator at the Laboratori Nazionali del Gran Sasso. Candidate events are identified through a precise measurement of their energy. The absolute energy response of the detectors is established by the regular calibration of each individual bolometer using gamma sources. The close-packed configuration of the CUORE bolometer array combined with the extensive shielding surrounding the detectors requires the placement of calibration sources within the array itself. The CUORE Detector Calibration System is designed to insert radioactive sources into and remove them from the cryostat while respecting the stringent heat load, radiopurity, and operational requirements of the experiment. In conclusion, this paper describes the design, commissioning, and performance of this novel source calibration deployment system for ultra-low-temperature environments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MARIE: A Python-Based Framework for Comprehensive Fuel Recycling Modeling

One of the most pressing challenges to the continued deployment of nuclear energy systems is in the ultimate management and disposition of discharged fuel assemblies. While reprocessing and recovery of valuable materials from UNF assemblies has been considered as part of an overall strategy for minimization of the volume of reactor-based wastes to be managed, the deployment of commercial-scale reprocessing facilities presents an enormous economic challenge. The MARIE software package has been developed as a means of confronting this challenge. Representing components of a generic fuel reprocessing operation as individual physical processes, MARIE is designed as a modular framework intended to allow for analysis and cost-optimization for a hypothetical reprocessing facility while realistically accounting for the physical characteristics of the used fuel source term, such as decay heat, activity, and radiation dose (informing corresponding shielding requirements). Capabilities supported by MARIE include head-end operations such as fuel shearing, voloxidation, and dissolution; generic solvent extraction operations informed by available open-literature data; a suite of unit operations intended to represent electrochemical processing of used fuel assemblies (i.e., oxide reduction, electrorefining, and electrowinning); and finally, accounting for both costs and physical features of discharged waste streams, which can be used to inform follow-on analyses such as the feasibility of deep-borehole disposal of HLW. This paper presents an overview of the MARIE software capabilities, including how individual unit operations are implemented to enable a larger-scale optimization of a hypothetical reprocessing operation on aspects such as cost and recovery of valuable materials.

Skutnik, Steve [ORNL] (ORCID:000000016441135X)↗

New Virtual Test Bed Capabilities: Virtual DOME Model and New Updates to Repository

The Department of Energy (DOE) Office of Nuclear Energy National Reactor Innovation Center accelerates the deployment of novel reactor concepts by establishing both physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed represents the virtual arm of the National Reactor Innovation Center and is a joint effort with the DOE Nuclear Energy Advanced Modeling and Simulation Program. The Virtual Test Bed mission is to accelerate the deployment of advanced reactors by facilitating the adoption of cutting-edge DOE advanced modeling and simulation tools to design, evaluate, and license reactors. This is primarily achieved by storing example challenge problems in an externally available repository and by developing models to fill the M&S gaps needed for potential demonstrators. Activities conducted this fiscal year focused on developing of a Demonstration of Microreactor Experiments shield model to help accelerate the confirmatory analysis required for the reactor demonstration. This model and workflow will allow developers to leverage advanced modeling and simulation tools to ensure their reactor demonstration concept will meet dose requirements and that the surrounding shield will stay within concrete temperature limits during steady-state and transient operation conditions. An initial model has been developed to evaluate the temperature distribution in the concrete shield during steady-state operation, including neutron and gamma heating effects. Various modeling strategies have been examined to understand their applicability and limitations with different reactor designs to make the workflow as reactor-agnostic as possible and computationally effective to maximize its usability. In addition to describing the Demonstration of Microreactor Experiments shield model and associated results, this report summarizes other accomplishments regarding repository maintenance and improvement and new external models hosted on the repository.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of The DOME Shield Model For The NRIC Virtual Test Bed

As several advanced reactor concepts are maturing, test beds are needed to accelerate the demonstration and deployment of these advanced nuclear technologies. The National Reactor Innovation Center (NRIC) is building new or enhancing existing US Department of Energy infrastructure to support testing of components and systems. Demonstration of Microreactor Experiments (DOME) will utilize the Experimental Breeder Reactor-II (EBR-II) dome containment structure to host reactor demonstrations. A reactor supplemental shielding is needed so that DOME dose requirements are met. To accelerate the confirmatory analysis required for the reactor demonstration, the NRIC Virtual Test Bed (VTB) is developing a virtual model of the DOME shield that will be made available on the VTB public repository. This will allow developers to leverage advanced modeling and simulation tools to ensure their reactor demonstration concept will meet dose requirement and the limit concrete temperature in the shield during steady state and transient operation conditions. This paper presents the model developed for the DOME shield using open-source tools: MOOSE heat transfer module, Monte Carlo code OpenMC, and Cardinal to calculate the DOME shield temperature distribution during steady state

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

{sup 99m}Tc generators for clinical use based on zirconium molybdate gel and (n, gamma) produced {sup 99}Mo: Indian experience in the development and deployment of indigenous technology and processing facilities

The Indian pursuit of gel generator technology for {sup 99m}Tc was driven mainly by three considerations, namely, (i) well-established and ease of reliable production of (n, gamma)-based {sup 99}Mo in several tens of GBq quantities in the research reactors in Trombay/Mumbai, India, (ii) need for relatively low-cost alternate technology to replace the solvent (MEK) extraction generator system in use in India since 1970s and (iii) minimize dependency on weekly import of fission-produced {sup 99}Mo raw material required for alumina column generator. Extensive investigations on process standardisation for zirconium molybdate gel (ZMG) led to a steady progress, achieved both in terms of process technology and final performance of {sup 99m}Tc gel generators. The {sup 99m}Tc final product purity from the Indian gel system was comparable to that obtained from the gold-standard alumina column generators. Based on the feasibility established for reliable small-scale production, as well as satisfactory clinical experience with a number of gel generators used in collaborating hospital radiopharmacies, full-fledged mechanised processing facilities for handling up to 150 g of ZMG were set up. The indigenous design and development included setting up of shielded plant facilities with pneumatic-driven as well as manual controls and special gadgets such as, microwave heating of the zirconium molybdate cake, dispenser for gel granules, loading of gel columns into pre-assembled generator housing etc. Formal review of the safety features was carried out by the regulatory body and stage-wise clearance for processing low and medium level {sup 99}Mo activity was granted. Starting from around 70 GBq {sup 99}Mo handling, the processing facilities have since been successfully operated at a level of 740 GBq {sup 99}Mo, twice a month. In all 18 batches of gel have been processed and 156 generators produced. The individual generator capacity was 15 to 30 GBq with an elution yield of nearly 75%. 129 generators were supplied to 11 user hospitals and the estimated number of clinical studies done is well over 5000. The salient aspects of the Indian experience have been reported in many a forum and shared with the IAEA through the on-going CRP. The detailed process know-how is available for technology transfer from BRIT, India. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Efficient and assured reinforcement learning-based building HVAC control with heterogeneous expert-guided training

Abstract Building heating, ventilation, and air conditioning (HVAC) systems account for nearly half of building energy consumption and $$20\%$$ of total energy consumption in the US. Their operation is also crucial for ensuring the physical and mental health of building occupants. Compared with traditional model-based HVAC control methods, the recent model-free deep reinforcement learning (DRL) based methods have shown good performance while do not require the development of detailed and costly physical models. However, these model-free DRL approaches often suffer from long training time to reach a good performance, which is a major obstacle for their practical deployment. In this work, we present a systematic approach to accelerate online reinforcement learning for HVAC control by taking full advantage of the knowledge from domain experts in various forms . Specifically, the algorithm stages include learning expert functions from existing abstract physical models and from historical data via offline reinforcement learning, integrating the expert functions with rule-based guidelines, conducting training guided by the integrated expert function and performing policy initialization from distilled expert function. Moreover, to ensure that the learned DRL-based HVAC controller can effectively keep room temperature within the comfortable range for occupants, we design a runtime shielding framework to reduce the temperature violation rate and incorporate the learned controller into it. Experimental results demonstrate up to 8.8 X speedup in DRL training from our approach over previous methods, with low temperature violation rate.

Xu, Shichao↗

Detection of Diversion in a Realistic Heat Pipe Microreactor Using Supervised Machine Learning

Microreactors (MRs) pose new challenges for international safeguards. Here, their small size and mass reproducibility make them ideal for deployment in greater numbers and in remote locations, making the job of safeguards inspectors more challenging. Machine learning (ML) is currently being applied to many fields to augment human performance and increase automation; in particular, ML could be used to provide insight for international inspectors to help detect the diversion of nuclear fuel from MR cores. Four ML model types (k-nearest neighbors, decision tree, random forest, and histogram-based gradient boosted ensemble) were trained on integrated flux and critical control drum angle data generated with Serpent 2 for a realistic heat pipe MR design, achieving nearly 100% binary classification accuracy of nominal and diversion core configurations by the end of 1 full power year for three of the four model types. Regression model variants were also trained, using the same input data, for predicting the number of fuel pins diverted. Root-mean-square errors below 5% of the total number of fuel pins were achieved by the 1 full power year mark for all models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

TCCR Operational Summary and Optimization for Tank 9 Processing - 20314

Savannah River Remediation (SRR) manages and operates the liquid waste facilities at Savannah River Site (SRS) for the Department of Energy (DOE). Stored liquid waste is a complex mixture of insoluble solids (sludge) and soluble salts in an alkaline solution. SRR has deployed the Tank Closure Cesium Removal (TCCR) system, a tank-side ion exchange process, to remove radioactive cesium from salt waste and enable onsite disposal of the resulting decontaminated salt solution as low-level waste at the Saltstone facilities. The TCCR system consists of two prefilters, four ion exchange (IX) columns, one resin trap, and a ventilation system. The IX process uses a form of inorganic crystalline silicotitanate (CST), which has a high affinity for cesium and other alkali metals, strontium, and actinides. This process is currently deployed utilizing salt feed from Tank 10, with future plans to dissolve solid salt in Tank 9 and transfer the salt solution to Tank 10 for processing through TCCR. The feed for TCCR must be created from salt-cake in Tank 10 through a dissolution process. Once enough salt has been dissolved, a qualification process is entered. This process characterizes the feed and ensures the cesium loading on the columns will not cause boiling of waste within the columns during or after processing. Once the batch has been qualified, salt waste is fed to the TCCR system through a transfer pump in the center of the tank. The waste is filtered through a set of two shielded, dead-end prefilters that prevent solids buildup in the columns. The filtered salt solution then travels to the shielded IX columns, which can be operated individually or in series, where the cesium is sorbed on the CST media. The decontaminated salt solution (DSS) then travels through a resin trap and out of the module to Tank 11. TCCR has successfully processed approximately 795,000 L of Tank 10H radioactive salt waste over two batches to date. There has not yet been a system induced shutdown. The prefilters performed as expected with only minor degradation in recovery of differential pressure after a backflush sequence. The time between backflushes decreased as each batch reached the end of processing. The hydraulics in the IXCs mostly performed as expected at all flow rates, except for one IXC that will be further investigated during Batch 3 processing. The TCCR system has shown some opportunities for more efficient processing during the length of the demonstration so far. For future processing of material from Tank 9H through Tank 10H and the TCCR unit, TCCR 1A will implement changes to the prefilters and the IXCs. The prefilters will have an increased surface area and a new filter media in an effort to increase time between filter swaps and improve backwashing cleaning capability. The IXCs will have a reduced diameter to allow for increased heat transfer out of the column and increased loading of Cs-137. Additionally, a new form of CST with an increased kinetic performance is being investigated for use during TCCR 1A operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NUHOMS{sup R} EOS (Extended Optimized Storage): Robust, Advanced, and Dual Purpose Dry Storage System - 16472

AREVA TN has completed the design, analysis, and US NRC license submittal for the NUHOMS{sup R} Extended Optimized Storage (EOS) system. NUHOMS{sup R} EOS offers a large capacity and high heat load dry storage and transportation solution for UNF. EOS is not a new system, but an evolution of the already-proven safe and low-risk horizontal NUHOMS{sup R} storage system, which is one of the most widely used UNF dry storage systems in the United States. The EOS system features a 37PTH dry shielded canister (DSC) for 37 PWR UNF assemblies and an 89BTH DSC for the 89 BWR UNF assemblies. The EOS DSCs will be stored inside a horizontal storage module (HSM) that is a robust, fortress-like concrete storage overpack. Designed with the lessons learned from the Fukushima event in Japan in mind, EOS has robust margins for beyond design basis (BDB) events and offers the lowest risk and highest safety margin of any dry storage system design for recovery from BDB events. EOS also offers innovative aging management features with an aging management program (AMP) to assure safe and low dose long-term storage at the utility sites. EOS incorporates ports for AMP inspections and offers the option of using duplex stainless steel (DSS) for the DSC shell in order to negate corrosion issues. EOS is stored horizontally and above ground, making it easy and quick to access for visual inspection, monitoring, and mitigating actions during AMP. NUHOMS{sup R} EOS is optimized for high capacity, high burnup, high enrichments, and very low cooling times for UNF assemblies. It enables the highest heat load per canister (50 kW) and low dose rates. Even with high heat loads, EOS has significant margins to design basis limits. As the future of used fuel disposition will require the need to move fuel off-site to interim or consolidated storage, EOS is the ideal solution as it enables on-site loading and unloading operations that mitigate risk when transferring fuel on-site or transporting fuel off-site. The EOS design can be safely located in a traditional outdoor setting with fortress-like concrete reinforced modules that offer superior resistance to attack or can be safely operated inside of a building enclosure for those utilities desiring a more discreet siting for its used fuel storage systems. EOS has an innovative basket design that is made of high strength low alloy (HSLA) material and is easy to fabricate due to its non-welded design. Its innovative inlet and outlet air vent design, which incorporates dose reduction hardware, allows for optimal ambient airflow for highly efficient heat transfer with minimal radiation dose. The NUHOMS{sup R} EOS storage modules are interlocked in a side-by-side configuration offering superior and robust seismic performance. The license application for NUHOMS{sup R} EOS is currently under US NRC review and this system will be available for deployment in 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗