Search NASA⌕ Search

SEARCH · Search NASA

Results for “Desiccant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Desiccants enabling energy-efficient buildings: A review

Buildings account for about 39% of the total energy consumption in the United States. Developing highly energy-efficient and environmentally friendly systems that are either actively or passively integrated into buildings plays a crucial role in decarbonizing the building sector. Among various technologies, desiccant-based energy systems have received particular attention in recent years due to their unique advantages, such as being thermally driven using low-grade waste or solar energies and being reliable over a wide range of operating ranges. Extensive research efforts have been exerted on desiccant-enabled technologies at both material and system levels aiming to increase their performance and achieve high technological readiness levels. The present review paper comprehensively discusses research works made at the system level. It overviews desiccant-based air conditioning systems, desiccant-based humidity pumps, desiccant-based thermal energy storage systems, and desiccant-based appliances. The study identifies challenges and opportunities to accelerate the commercialization of desiccant-enabled technologies. It is found that desiccant materials offer great promise to improve energy efficiency and functionality of future buildings through decoupling the latent and sensible cooling loads in air conditioning systems, humidity pumps integrated into building facades, and next-generation appliances. However, commercial viability and widespread acceptance of desiccant-based systems have been hampered by several major obstacles, including liquid and air flow mal-distribution and inferior thermo-physical properties of desiccant materials resulting in low ab/adsorption and regeneration rates and bulky/costly systems.

25 ENERGY STORAGE↗

Dehumidification energy storage using a stratified liquid desiccant tank

Liquid desiccants can play an important role in reducing dehumidification energy requirements in the built environment. Because they are in a liquid state, the desiccant can be easily stored and then used to dehumidify buildings during peak energy consumption periods. By maintaining stratification between concentrated and diluted desiccant solutions, a single tank can be used to store liquid desiccant for energy storage purposes. Using a stratified tank instead of separate tanks for dilute and concentrated solutions will reduce storage costs and increase energy storage densities for liquid desiccant systems. This paper describes the experimental validation and one-dimensional modeling of a stratified liquid desiccant tank. The stratified tank prototype developed achieved 80 % of the theoretical energy storage density based on an imposed desiccant concentration change. Here, the stratified tank model was able to reasonably reproduce the experimental results. Using this model, the impact of varying operational conditions on the energy density of the stratified liquid desiccant energy storage was evaluated. Depending on the operating conditions, stratified liquid desiccant energy storage using aqueous LiCl up to 40 wt% can achieve energy storage densities in excess of 330 kWh/m 3 .

25 ENERGY STORAGE↗

The energy saving potential of thermo-responsive desiccants for air dehumidification

The desiccant wheel is a promising technology for energy-efficient humidity control. However, its overall efficiency—hindered by the desiccant materials’ properties—remains low because traditional desiccants (e.g., silica gels) have a single isotherm regardless of their adsorption temperature. Thermo-responsive materials have been proposed to break this fixed affinity to water vapor, with drastically different adsorption isotherms depending on temperature. Its potential for improving dehumidification efficiency, however, has not been addressed. In this paper, we model the potential of a thermo-responsive interpenetrating polymer network (IPN) desiccant with temperature-dependent adsorption isotherms for energy-efficient dehumidification via a validated transient desiccant wheel model for humidity control of buildings. Thermo-responsive desiccants can improve the dehumidification performance due to their thermo-responsive switchable hydrophilicity below/above the lower critical solution temperature. Our analysis shows that thermo-responsive IPN desiccants can potentially reduce energy consumption by up to 30% compared to silica gels. Finally, the savings depend strongly on the critical temperature of the thermo-responsive desiccant and should be higher when the inlet temperatures are expected to be higher.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented in this paper. We report this model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. The results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.

42 ENGINEERING↗

Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented here. This model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. Finally, the results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.

42 ENGINEERING↗

Critical review and future prospects for desiccant coated heat exchangers: Materials, design, and manufacturing

Solid desiccant dehumidification is a promising alternative to vapor compression-based air-dehumidification to reduce energy consumption and improve air quality. Desiccant coated heat exchanger (DCHE), as one type of solid desiccant dehumidification system, can improve system performance and efficiency. The thermal performance and moisture removal capability of the DCHE greatly influence its dehumidification performance.The present work aims to critically analyze the designs, materials, and manufacturing methods of heat exchangers used for solid desiccant coating and look into recent developments in regular heat exchangers, potentially deployed as a substrate for DCHE applications. A comprehensive literature review of publications regarding solid desiccant materials, heat exchangers, manufacturing and coating methods, binder materials, and the performance of heat exchangers has been developed. Alternative heat exchangers are described as better options than fin and tube heat exchangers that have been considered thus far for DCHE applications. Additionally, the heat exchanger's manufacturing process and materials over their thermal and mass exchange performance have been analyzed. Despite the widespread use of fin and tube heat exchangers for solid desiccant coating, recent developments in heat exchanger design, and related fields such as manufacturing methods and materials, open the possibilities for their application in solid desiccant dehumidification systems. Lastly, the authors provide their outlook on possible developments of DCHE technology, aiming to increase systems' energy and dehumidification performance.

36 MATERIALS SCIENCE↗

A methodology for selection of solid desiccants in energy recovery ventilators

Controlling indoor humidity levels is essential for maintaining acceptable indoor air quality in buildings. The use of energy recovery ventilators (ERVs) is an energy-efficient way to regulate indoor air humidity. Fixed-bed regenerators and rotary wheels are widely used ERVs because of their high sensible and latent effectiveness. These ERVs are made of desiccant-coated substrates, which enable them to transfer moisture between the supply and exhaust air streams. However, the moisture transfer ability of ERVs depends on the physiochemical and sorption properties of desiccants. Extensive, full-scale experiments are required to determine the best desiccant material for these systems. This paper presents a simplified method of selecting suitable desiccant materials for ERVs. The methodology involves important characterization methods, literature correlations for performance prediction, and cost-effective testing methods prior to full-scale testing, and full-scale test methods are discussed in detail. Furthermore, the performance of a few newly derived materials is evaluated and compared with that of conventional desiccants such as silica gel and molecular sieves. The highest latent effectiveness was obtained for composite of super absorbent polymer (SAP) with potassium formate (SAP-HCO2K-50 %), all-polymer porous solid desiccant (APPSD) and metal organic framework (MOF)–MIL–101 (Cr), followed by activated carbon fibre felt (ACFF) Silica sol-LiCl30, SAP, silica gel, MOF–303, and molecular sieve. Researchers and manufacturers would benefit from the proposed methodology and presented data in developing new desiccant materials for ERV applications.

Energy recovery↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tripogon loliiformis tolerates rapid desiccation after metabolic and transcriptional priming during initial drying

Abstract Crop plants and undomesticated resilient species employ different strategies to regulate their energy resources and growth. Most crop species are sensitive to stress and prioritise rapid growth to maximise yield or biomass production. In contrast, resilient plants grow slowly, are small, and allocate their resources for survival in challenging environments. One small group of plants, termed resurrection plants, survive desiccation of their vegetative tissue and regain full metabolic activity upon watering. However, the precise molecular mechanisms underlying this extreme tolerance remain unknown. In this study, we employed a transcriptomics and metabolomics approach, to investigate the mechanisms of desiccation tolerance in Tripogon loliiformis , a modified desiccation-tolerant plant, that survives gradual but not rapid drying. We show that T. loliiformis can survive rapid desiccation if it is gradually dried to 60% relative water content (RWC). Furthermore, the gene expression data showed that T. loliiformis is genetically predisposed for desiccation in the hydrated state, as evidenced by the accumulation of MYB, NAC, bZIP, WRKY transcription factors along with the phytohormones, abscisic acid, salicylic acid, amino acids (e.g., proline) and TCA cycle sugars during initial drying. Through network analysis of co-expressed genes, we observed differential responses to desiccation between T. loliiformis shoots and roots. Dehydrating shoots displayed global transcriptional changes across broad functional categories, although no enrichment was observed during drying. In contrast, dehydrating roots showed distinct network changes with the most significant differences occurring at 40% RWC. The cumulative effects of the early stress responses may indicate the minimum requirements of desiccation tolerance and enable T. loliiformis to survive rapid drying. These findings potentially hold promise for identifying biotechnological solutions aimed at developing drought-tolerant crops without growth and yield penalties.

59 BASIC BIOLOGICAL SCIENCES↗

Engineered Polymer Architectures for Thermo–Responsive Desiccants in Dehumidification Applications

Humidity control is relevant to many processes in buildings and manufacturing and is responsible for over 600 million tons of CO 2 annually. As such, desiccants that can efficiently remove moisture from air can greatly reduce emissions. A new class of desiccant materials, thermo–responsive desiccants, has been of increased interest in the literature. These materials are generally based on thermo–responsive polymers and exhibit a temperature–dependent isotherm, an attribute that is small in traditional desiccants. In this work, seven key parameters needed to create an effective thermo–responsive polymer desiccant are identified using a combination of modeling and experimental data. Further, it is found that more thermo–responsiveness is not necessarily better for energy efficiency, and that an optimal, “medium” value is desired. Additionally, polymer composition and architecture play key roles in adjusting the seven key parameters. Finally, based on findings from both modeling and experimental work, guidelines on synthesizing future thermo–responsive polymer desiccants are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An experimental study on dehumidification and regeneration performance of a new nonporous membrane-based heat and mass exchanger using an ionic liquid desiccant

As a promising alternative to inefficient vapor-compression-based air conditioning, liquid desiccant dehumidification uses a liquid desiccant in contact with the humid air absorbing the moisture. However, it has not gained much market share due to the issues related to the carryover, corrosion, fouling, and crystallization of liquid desiccant. The research has developed a new membrane-based exchanger, which uses a non-corrosive ionic liquid desiccant and nonporous tubular membranes to address these issues. As the second generation of the prototype, the new exchanger was tested at various operating conditions. According to the experimental data, when it is used in the dehumidification loop, the new membrane-based exchanger achieves a specific vapor transportation rate of 778.6 g/(h–m 2 ) and an average water vapor flux of 0.316 g/(h-m 2 -Pa), which is a significant improvement compared with the previous designs using nonporous membranes. It also achieved a comparable or even better dehumidification performance compared with the dehumidifiers that use porous membrane and conventional liquid desiccants. However, the regeneration performance is not as good as its dehumidification. It is mainly caused by the high operating temperature required in the regeneration loop. The experimental data and findings provide first-hand experimental data and enhance the understanding of advanced membrane-based ionic liquid desiccant systems.

42 ENGINEERING↗

Advances in Desiccant Wheels for Dehumidification, VOC Mitigation, and CO 2 Removal for Energy-Efficient IAQ Management

Humidity control is pivotal to maintain occupant thermal comfort and suppress mold growth in indoor environments. Furthermore, poor indoor air quality (IAQ) due to the presence of volatile organic compounds (VOCs) and high concentrations (>1,000 ppm) of CO 2 can cause health issues and negatively affect cognitive performance. Therefore, providing high-quality indoor air has gained significant attention over the past decade. Conventional cooling coil and filter-based HVAC systems have limited capability to meet the augmented demand for occupant thermal comfort and high indoor air quality. Moreover, modern buildings are increasingly airtight to save energy, and increasing ventilation to mitigate VOC and CO 2 concentration is discouraged. Separate sensible and latent cooling technology using a rotary desiccant wheel presents a promising solution in this respect. Because of the development of desiccant materials with high water vapor, VOC, and CO 2 uptake, desiccant wheels can be used as an integrated technology option for IAQ management. Here, to promote desiccant wheel use for energy-efficient management of IAQ in buildings, this article reviews recent advancements in using desiccant wheels for dehumidification, VOC mitigation, and CO 2 capture from outdoor air. Finally, the article presents the authors’ perspective by summarizing the key research gaps in the field and discussing the future direction of research to address these gaps from two different aspects, namely, suitable adsorbent material development and desiccant wheel design.

CO2 capture↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗

A first and second law analysis of a thermoresponsive polymer desiccant dehumidification and cooling cycle

Herein, we present a theoretical description for a new desiccant air conditioning cycle that uses thermoresponsive polymers instead of traditional desiccants. We use a combined first and second law analysis to demonstrate that this new cycle has three major advantages relative to the traditional case: (i) it can regenerate at lower temperatures, (ii) it can harvest liquid water and (iii) it has significantly higher coefficients of performance (COPs). For example, this new cycle can achieve a COP of 5.1 when regenerated at 95 degrees C, whereas the traditional desiccant cycle is limited to a COP of ~ 1. The fundamental origins of these advantages can be traced to the method of regeneration. The traditional desiccant cycle regenerates by flowing hot air over the desiccant, which provides a medium for gaseous water desorption. However, this also generates entropy and places a minimum temperature constraint on the hot air. In contrast, the thermoresponsive polymer cycle regenerates through a polymer phase transition. The polymer absorbs water vapor in humid air, and then it expels liquid water when raised above its transition temperature. This regeneration method generates liquid water that can be harvested and relaxes constraints on entropy generation and minimum temperature. The minimum regeneration temperature of the thermoresponsive cycle is only limited by the transition temperature of the polymer, which can be tuned through materials science. Due to its liquid water harvesting capability, the new cycle potentially eliminates water consumption when used with evaporative cooling, or it can be directly used for atmospheric water harvesting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers

We report that to dehumidify a humid air stream, existing air conditioning (AC) systems substantially overcool the outdoor humid air below its dew point, thereby significantly reducing energy efficiency. Directly capturing humidity, membrane-based liquid-desiccant dehumidification systems separate sensible and latent cooling (SSLC) loads and thus offer a promising pathway for a high-performance AC solution. Design of an energy-efficient SSLC-AC system, however, rests largely on detailed understating of the dehumidification process. While some studies have identified the dehumidification process mainly depends on membrane characteristics, other studies have argued that the process is limited by desiccant liquid or alternatively air thermo-hydraulic physics for typical humid climate conditions. The present study examines performance and physics of the membrane-based liquid-desiccant dehumidification process over a wide range of climate conditions through a novel 3D, two-phase, multi-species CFD model. Decoupling the thermodynamic and hydraulic effects, the study reveals that the dehumidification rate is a linear function of the water vapor pressure potential ($J=α ΔP$) summarizing the system's thermodynamic state. The slope of the curve (i.e., α) depends on hydraulic transport characteristics of the membrane pores, air stream, and desiccant solution. More importantly, it was found that the air dehumidification process is mainly limited by the air-side transport physics for thin liquid-desiccant films and commonly used porous superhydrophobic membranes. Additionally, results show that, depending on ambient/desiccant conditions and physical dehumidifier characteristics, energy effectiveness and dehumidification rate vary from 13 to 34% and from 0.13 to 1.4 g m -2 s -1 , respectively. Therefore, the present study allows to efficiently design future SSLC-based AC systems exhibiting high performance energy metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗