Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Estimating Cosmic Ray Spectral Parameters From Simulated Detector Responses With Detector Design Implications

A simple power law model consisting of a single spectral index alpha (sub 1), is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 10(exp 13) eV, with a transition at knee energy E(sub k) to a steeper spectral index alpha(sub 2) greater than alpha(sub 1) above E(sub k). The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, L. W.↗

Estimating Cosmic-Ray Spectral Parameters from Simulated Detector Responses with Detector Design Implications

A simple power law model consisting of a single spectral index (alpha-1) is believed to be an adequate description of the galactic cosmic-ray (GCR) proton flux at energies below 10(exp 13) eV, with a transition at knee energy (E(sub k)) to a steeper spectral index alpha-2 > alpha-1 above E(sub k). The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, L. W.↗

Improved modeling of detector response effects in phonon-based crystal detectors used for dark matter searches

Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve single-charge sensitivity when a voltage bias is applied across the detector. The total amount of phonon energy measured by such a detector is proportional to the number of electron-hole pairs created by the interaction. However, crystal impurities and surface effects can cause propagating charges to either become trapped inside the crystal or create additional unpaired charges, producing non-quantized measured energy as a result. A new analytical model for describing these detector response effects in phonon-based crystal detectors is presented. This model improves upon previous versions by demonstrating how the detector response, and thus the measured energy spectrum, is expected to differ depending on the source of events. Finally, we use this model to extract detector response parameters for SuperCDMS HVeV detectors, and illustrate how this robust modelling can help statistically discriminate between sources of events in order to improve the sensitivity of dark matter search experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating gas-filled neutron detector responses with DRiFT

– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpolation of computed gamma-ray detector response functions

Gamma-ray spectra measured by traditional detectors contain features that result from a combination of the effects of detector materials/geometry, the incident gamma-ray energy, and the angle of entry. The features, such as the full-energy photopeak, Compton continuum, annihilation peak, and escape peaks, are governed by simple relationships depending on incident energy and have been known for a long time. Monte Carlo computer simulations of gamma rays interacting with a detector will show these features, and with a resolution function applied, the results should look similar to real measurements. The traditional approach to creating a detector response function requires many separate simulations of monoenergetic gamma rays striking the detector. This paper presents a new approach to developing computed detector response functions. The new approach involves a much smaller number of monoenergetic gamma-ray simulations and uses interpolation to quickly generate the responses of gamma rays that were not simulated. During the interpolation process, the underlying physics equations are used to accurately compute the response of a given energy gamma ray from the small set of simulations. Such work enables accelerated generation of synthetic radiation detector data.

Detector response↗

Generative machine learning for detector response modeling with a conditional normalizing flow

In this paper, we explore the potential of generative machine learning models as an alternative to the computationally expensive Monte Carlo (MC) simulations commonly used by the Large Hadron Collider (LHC) experiments. Our objective is to develop a generative model capable of efficiently simulating detector responses for specific particle observables, focusing on the correlations between detector responses of different particles in the same event and accommodating asymmetric detector responses. Here, we present a conditional normalizing flow model ($\mathcal{CNF}$) based on a chain of Masked Autoregressive Flows, which effectively incorporates conditional variables and models high-dimensional density distributions. We assess the performance of the $\mathcal{CNF}$ model using a simulated sample of Higgs boson decaying to diphoton events at the LHC. We create reconstruction-level observables using a smearing technique. We show that conditional normalizing flows can accurately model complex detector responses and their correlation. This method can potentially reduce the computational burden associated with generating large numbers of simulated events while ensuring that the generated events meet the requirements for data analyses. We make our code available at https://github.com/allixu/normalizing_flow_for_detector_response

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The detector response matrices of the burst and transient source experiment (BATSE) on the Compton Gamma Ray Observatory

The detector response matrices for the Burst And Transient Source Experiment (BATSE) on board the Compton Gamma Ray Observatory (CGRO) are described, including their creation and operation in data analysis. These response matrices are a detailed abstract representation of the gamma-ray detectors' operating characteristics that are needed for data analysis. They are constructed from an extensive set of calibration data coupled with a complex geometry electromagnetic cascade Monte Carlo simulation code. The calibration tests and simulation algorithm optimization are described. The characteristics of the BATSE detectors in the spacecraft environment are also described.

Pendleton, Geoffrey N.↗

Some observations on spin detector response during Galileo high gain antenna deployment

This paper summarizes a dynamic analysis conducted in support of the investigation of the anomalous deployment of the Galileo High Gain Antenna on April 11, 1991. The work was focused on modeling the spacecraft spin dynamics to predict and compare the spin detector telemetry during the antenna deployment for possible cause scenarios. The effects of analog and digital low-pass filtering, digitization, and telemetry on the reported spin rate were studied as well. The high frequency phenomena in the spin detector response are masked by the filtering and sampling of the telemetry data. However, the observed spin detector telemetery is consistent with a single rib popping free, and is most likely associated with a rib near the spin detector, or 180 deg opposite.

Peng, Chia-Yen↗

Microwave biasing improves detector response in the infrared region

Detection system, which incorporates advantages of microwave biasing, measures output of a carbon dioxide laser at 10.6 microns with a factor of 1,000 improvement in sensitivity. Material lifetime, rather than external circuitry, limits detector response time.

Sun, C.↗

Estimating Cosmic Ray Spectral Parameters from Simulated Detector Responses

A simple power law model consisting of a single spectral index al is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 100 TeV, with a transition at kink energy Ek to a steeper spectral index a2>al above Ek. The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, Leonard↗

Detector Response and Battery Reliability

The Sandia National Laboratories (SNL) Material Control and Accountability (MC&A) measurements team performs confirmation measurements of Special Nuclear Material (SNM) at different locations around Sandia. The measurement team has access to two High purity Germanium (HPGe) detectors, the AEGIS (Model: AEGIS-BEGE5030), and the ORTEC (Model: trans-SPEC-DX-100). These two can operate purely on battery power, but the response of the detectors while on battery power is not well documented. To enhance our knowledge with these detectors the team wants to investigate the detectors response to changes in battery range, wall charging, and mid operation battery swaps (Hot Swaps).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Source Geometry on Detector Response Matrix Efficiency: Simulations of the PFUNS-MUSiC Experiments

This work looks at two different bare highly enriched uranium (HEU) systems, configuration one from Measurements of Uranium Subcritical and Critical (MUSiC) and Prompt Fission Uranium Neutron Spectrum (PFUNS) to see the effect geometry has on detector efficiency and the response matrix. The distance from the multiplying source, the medium between the source and detector, and the geometry of the source all play a part in the efficiency of the detector. These factors are especially important when performing spectrum unfolding. Spectrum unfolding is a process used to reconstruct a true spectrum from measured detector response data. It involves interpreting a set of measured values, such as a light signal from a scintillator, to recover the original neutron energy spectrum. This leads to the question, how much will the efficiency of a detector change when you measure a point source compared to an extended source? The distance and solid angle from the source to the detector may be different. It may only be a minuscule change, but in the spectrum unfolding process it can have a considerable effect on the unfolded spectrum

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Nonlinear Detector Response of Aqua MODIS Land Imaging Bands

The detectors in Aqua MODIS reflective solar bands (RSB) are calibrated assuming a linear relationship between the observed top-of-atmosphere radiance and the instrument output response. Any non-linear behavior in the system response can contribute to errors in NASA’s Level 1B MODIS reflectance and radiance products, which are used in a wide variety of Earth science applications. While most RSB detectors continue to have very linear behavior even after more than 18 years of operation, we present evidence that the detectors in Aqua MODIS bands 1 (645 nm) and 2 (858 nm) have deviations from gain linearity that change over the mission by up to 3%. We show a clear divergence between gain measurements made with the on-board solar diffuser (SD) at two different radiance levels, achieved by collecting data both with and without an attenuation screen. Radiance trends from lunar calibrations and typical desert and ocean scenes are also compared. We present a simple method to characterize the response non-linearity using a quadratic function by combining the results of the two sets of SD calibrations. Applying this quadratic calibration algorithm to the desert and lunar data results in improved agreement in their long-term radiance trends. A clear understanding of the magnitude of the gain non-linearity could be useful to help improve the quality of numerous MODIS science products, including the land imaging applications that rely heavily on these bands.

MODIS↗

Infrared detector responsivity measured simultaneously at multiple frequencies

The responsivity (the ratio of the output electrical signal to the incident radiation power) of an IR detector is measured at several frequencies simultaneously. A computer-controlled variable frequency chopper is used. Chopper modulation of a blackbody is square-wave-like, hence measurements can be taken not only at the fundamental frequency but also at the harmonics. The technique gives excellent agreement with the classical technique of measuring the fundamental response alone at a set of modulation frequencies. With a small enough aperture and a high enough chopper speed, agreement can be within five percent out to 31 times the fundamental frequency. The technique allows the rapid and automated acquisition of the frequency response of IR detectors, which may then be screened for responsivity, noise, and noise equivalent power.

Brasunas, John C.↗

Ultrafast IR detector response in high Tc superconducting thin films

The response from a high Tc superconducting multielement optical detector made of a laser deposited Y-Ba-Cu-O thin film has been evaluated. Several microscopic and spectroscopic techniques were used to establish the presence of the correct phase of the thin film. Optical pulses from a laser diode at 830 nm and from a Q-switched CO2-laser at 10.6 microns were used. The detector responded to 50 ps (FWHM) pulses. A comparison between dR/dT of the film and the response amplitude as a function of temperature indicated a bolometric response.

Lindgren, Mikael↗