Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Estimating Cosmic Ray Spectral Parameters From Simulated Detector Responses With Detector Design Implications

A simple power law model consisting of a single spectral index alpha (sub 1), is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 10(exp 13) eV, with a transition at knee energy E(sub k) to a steeper spectral index alpha(sub 2) greater than alpha(sub 1) above E(sub k). The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, L. W.↗

Estimating Cosmic-Ray Spectral Parameters from Simulated Detector Responses with Detector Design Implications

A simple power law model consisting of a single spectral index (alpha-1) is believed to be an adequate description of the galactic cosmic-ray (GCR) proton flux at energies below 10(exp 13) eV, with a transition at knee energy (E(sub k)) to a steeper spectral index alpha-2 > alpha-1 above E(sub k). The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, L. W.↗

The detector response matrices of the burst and transient source experiment (BATSE) on the Compton Gamma Ray Observatory

The detector response matrices for the Burst And Transient Source Experiment (BATSE) on board the Compton Gamma Ray Observatory (CGRO) are described, including their creation and operation in data analysis. These response matrices are a detailed abstract representation of the gamma-ray detectors' operating characteristics that are needed for data analysis. They are constructed from an extensive set of calibration data coupled with a complex geometry electromagnetic cascade Monte Carlo simulation code. The calibration tests and simulation algorithm optimization are described. The characteristics of the BATSE detectors in the spacecraft environment are also described.

Pendleton, Geoffrey N.↗

Some observations on spin detector response during Galileo high gain antenna deployment

This paper summarizes a dynamic analysis conducted in support of the investigation of the anomalous deployment of the Galileo High Gain Antenna on April 11, 1991. The work was focused on modeling the spacecraft spin dynamics to predict and compare the spin detector telemetry during the antenna deployment for possible cause scenarios. The effects of analog and digital low-pass filtering, digitization, and telemetry on the reported spin rate were studied as well. The high frequency phenomena in the spin detector response are masked by the filtering and sampling of the telemetry data. However, the observed spin detector telemetery is consistent with a single rib popping free, and is most likely associated with a rib near the spin detector, or 180 deg opposite.

Peng, Chia-Yen↗

Microwave biasing improves detector response in the infrared region

Detection system, which incorporates advantages of microwave biasing, measures output of a carbon dioxide laser at 10.6 microns with a factor of 1,000 improvement in sensitivity. Material lifetime, rather than external circuitry, limits detector response time.

Sun, C.↗

Estimating Cosmic Ray Spectral Parameters from Simulated Detector Responses

A simple power law model consisting of a single spectral index al is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 100 TeV, with a transition at kink energy Ek to a steeper spectral index a2>al above Ek. The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, Leonard↗

Nonlinear Detector Response of Aqua MODIS Land Imaging Bands

The detectors in Aqua MODIS reflective solar bands (RSB) are calibrated assuming a linear relationship between the observed top-of-atmosphere radiance and the instrument output response. Any non-linear behavior in the system response can contribute to errors in NASA’s Level 1B MODIS reflectance and radiance products, which are used in a wide variety of Earth science applications. While most RSB detectors continue to have very linear behavior even after more than 18 years of operation, we present evidence that the detectors in Aqua MODIS bands 1 (645 nm) and 2 (858 nm) have deviations from gain linearity that change over the mission by up to 3%. We show a clear divergence between gain measurements made with the on-board solar diffuser (SD) at two different radiance levels, achieved by collecting data both with and without an attenuation screen. Radiance trends from lunar calibrations and typical desert and ocean scenes are also compared. We present a simple method to characterize the response non-linearity using a quadratic function by combining the results of the two sets of SD calibrations. Applying this quadratic calibration algorithm to the desert and lunar data results in improved agreement in their long-term radiance trends. A clear understanding of the magnitude of the gain non-linearity could be useful to help improve the quality of numerous MODIS science products, including the land imaging applications that rely heavily on these bands.

MODIS↗

Infrared detector responsivity measured simultaneously at multiple frequencies

The responsivity (the ratio of the output electrical signal to the incident radiation power) of an IR detector is measured at several frequencies simultaneously. A computer-controlled variable frequency chopper is used. Chopper modulation of a blackbody is square-wave-like, hence measurements can be taken not only at the fundamental frequency but also at the harmonics. The technique gives excellent agreement with the classical technique of measuring the fundamental response alone at a set of modulation frequencies. With a small enough aperture and a high enough chopper speed, agreement can be within five percent out to 31 times the fundamental frequency. The technique allows the rapid and automated acquisition of the frequency response of IR detectors, which may then be screened for responsivity, noise, and noise equivalent power.

Brasunas, John C.↗

Ultrafast IR detector response in high Tc superconducting thin films

The response from a high Tc superconducting multielement optical detector made of a laser deposited Y-Ba-Cu-O thin film has been evaluated. Several microscopic and spectroscopic techniques were used to establish the presence of the correct phase of the thin film. Optical pulses from a laser diode at 830 nm and from a Q-switched CO2-laser at 10.6 microns were used. The detector responded to 50 ps (FWHM) pulses. A comparison between dR/dT of the film and the response amplitude as a function of temperature indicated a bolometric response.

Lindgren, Mikael↗

Characterization of Photon-Counting Detector Responsivity for Non-Linear Two-Photon Absorption Process

Sub-band absorption at 1550 nm has been demonstrated and characterized on silicon Geiger mode detectors which normally would be expected to have no response at this wavelength. We compare responsivity measurements to singlephoton absorption for wavelengths slightly above the bandgap wavelength of silicon (approx. 1100 microns). One application for this low efficiency sub-band absorption is in deep space optical communication systems where it is desirable to track a 1030 nm uplink beacon on the same flight terminal detector array that monitors a 1550 nm downlink signal for pointingcontrol. The currently observed absorption at 1550 nm provides 60-70 dB of isolation compared to the response at 1064 nm, which is desirable to avoid saturation of the detector by scattered light from the downlink laser.

Geiger mode detector↗

Detector response in time-of-flight mass spectrometry at high pulse repetition frequencies

Dead time effects in chevron configured dual microchannel plates (MCPs) are investigated. Response times are determined experimentally for one chevron-configured dual MCP-type detector and two discrete dynode-type electron multipliers with 16 and 23 resistively divided stages. All of these detectors are found to be suitable for time-of-flight mass spectrometry (TOF MS), yielding 3-6-ns (FWHM) response times triggered on a single ion pulse. It is concluded that, unless there are viable solutions to overcome dead time disadvantages for continuous dynode detectors, suitable discrete dynode detectors for TOF MS appear to have a significant advantage for high repetition rate operation.

Gulcicek, Erol E.↗

Fire detector response in aircraft applications

Photoelectric, ionization, and gas sensors were used to detect the signatures from the radiant heat or flame of various aircraft materials. It was found that both ionization and photoelectric detectors are about equally capable of detecting products of pyrolysis and combustion of synthetic polymers, especially those containing fire-retardant additives. Ionization detectors alone appeared to be sensitive to combustion products of simple cellulosic materials. A gas sensor detector appeared to be insensitive to pyrolysis or combustion products of many of the materials.

Wiersma, S. J.↗

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗