Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct contact column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nitrogen evolution, NO X formation and reduction in pressurized oxy coal combustion

Oxy-combustion is one of the most prominent solutions for reducing CO 2 emissions from coal-fired power plants using carbon-capture-and-utilization technology. However, when compared to air combustion at atmospheric pressure, oxy-combustion is very expensive, owing to the significant efficiency penalties associated with air separation, flue gas recirculation (FGR), treatment, compression, and storage or transit of CO 2 . In comparison, pressurized oxy-combustion (POC) is more efficient as it recovers a significant amount of heat energy from the flue gas moistures. Nevertheless, CO 2 derived from pressurized oxy coal combustion has impurities, e.g., acid gases (NO X and SO X ) that can corrode the plant equipment, transport lines as well as deteriorating effect on the environment. Fortunately, in pressurized combustion systems, both NO X and SO X can be scrubbed by a single-column direct contact cooler (DCC), but this requires a minimum ratio of NO X to SO X at the inlet to be efficiently removed. Therefore, NOx is one of the important hindering parameters in commercializing the pressurized oxy-combustion. Although NOx evolution during oxy-coal combustion has been explored extensively at 1 atm, higher pressure studies are rare. Much still needs to be done to better understand the NO X mechanism and the effects of different parameters on NO X emissions under these conditions. Here, this paper reviews the published literature on nitrogen evolution, NO X formation and reduction in pressurized oxy-coal combustion. At higher pressures, the NO X from fuel-bound nitrogen is generated through volatiles, tar and char, all of which are discussed. Where literature is not available, the effect of pressure on NOx evolution in different stages of coal combustion is predicted through CHEMKIN simulation. Homogeneous and heterogeneous pathways of NO X formation and their destruction in pressurized oxy-coal combustion are evaluated. Additionally, the effect of pressure on a few mature and commercialized NOx abatement methods is explored. In the last, the future perspective and recommendation are given. This review will aid in the provision of basic knowledge about NOx evolution and control in pressurized fuel combustion, as well as the identification of new research areas to pursue.

01 COAL, LIGNITE, AND PEAT↗

A direct contact cooler design for simultaneously recovering latent heat and capturing SO x and NO x from pressurized flue gas

Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oxy-fuel combustion and power generation system

Integration of an oxyfuel combustion boiler at elevated pressures and a heat exchanger is achieved to produce carbon dioxide by feeding flue gas comprising carbon dioxide and water from the oxyfuel combustion boiler to a direct contact cooler column wherein water is condensed at a temperature of 0 to 10° C. lower than its dew point; feeding a portion of the condensed water from the direct contact cooler column to the oxyfuel combustion boiler; feeding a portion of the carbon dioxide from the direct contact cooler column to the oxyfuel combustion boiler; and recovering a portion of the carbon dioxide from the direct contact cooler column.

Alekseev, Alexander↗

Separation of volatile organic contaminants from water using a direct-contact dehumidifier: An experimental study and modeling

A packed-bed, direct-contact dehumidifier (PB-DCD) has been developed to selectively condense water from a gaseous mixture of organic contaminants. In this process, hot air is humidified by mixing with wastewater vapor in a static mixer and is dehumidified by subcooled fresh water passing through the PB-DCD in a counter-current configuration. The goal of this study is to understand the relationship between various operating parameters and how they affect separation of isopropyl alcohol (IPA) from the gaseous mixture with the purpose of expanding the investigation to other contaminants in the future. The process has been successfully used to separate IPA from wastewater. Different parameters including the concentration of IPA in water, feed temperature, air-to-vapor ratio, and cooling-water-to-vapor mass ratio, as well as residence time were examined to determine their influence on contaminant separation and clean water recovery rate. The Buckingham Pi theorem was applied to reduce the number of studying variables by generating non-dimensional groups. Experiments were performed to determine the relationship between the non-dimensional parameters and model mass transfer in the system. Mass transfer coefficients for multicomponent gaseous mixture condensation in a packed-bed direct contact condenser column are calculated and a modified correlation of mass transfer is developed. The parameters of the mass transfer model are obtained from operating conditions of the PB-DCD, stream conditions and thermodynamic properties. A modified Sherwood correlation is developed to predict IPA separation from a gaseous mixture consisting of air, water, and IPA. The modified Sherwood correlation is applied to successfully predict the Sherwood number with a mean absolute error equal to 6.6 %. According to the experimental results, the maximum IPA separation achieved was 76.3 %, which corresponds to a water recovery rate of 58.7 %.

42 ENGINEERING↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular stage pressurized oxy-combustion (SPOC) power plant for biomass firing and coal-biomass co-firing. The SPOC process was modelled using Aspen Plus®, and largely based on a previous model designed by this group for SPOC coal firing. To enable comparison with current National Energy Technology Laboratory (NETL) Bio-Energy Carbon Capture and Storage (BECCS) studies, a 550 MWe SPOC power plant with a supercritical Rankine cycle (241 bar, 593°C, and 593°C), and 90% carbon capture was modeled, and hybrid poplar biomass was chosen. Two cases were evaluated, namely 100% biomass (carbon negative) and 25% biomass co-firing (carbon neutral), and the 100% Powder River Basin coal firing case was chosen for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water regeneration. Unique to the SPOC process, the boilers are arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the water leaving the bottom of the DCC is at a sufficiently high temperature that it can be used for boiler feed water heating, improving plant thermal efficiency. The SPOC efficiencies were above the BECCS cases with capture, and no efficiency penalty on the SPOC plant was observed with an increase of biomass in the mix mostly due to the higher oxygen content in biomass that resulted in lower oxygen requirement from the ASU, and the higher moisture in biomass that due to the key benefit of the SPOC process can be partially recovered as latent heat.

Magalhaes, Duarte↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular SPOC power plant for biomass firing and coal-biomass co-firing. Two Rankine cycles were considered: a supercritical steam cycle (242 bar, 593°C, 593°C) with 550 MWe net output and a subcritical cycle (166 bar, 566°C, 566°C) with 200 MWe net output. For both cases, 95% carbon capture was modeled, and hybrid poplar biomass was chosen to generate carbon-negative power. In addition, the supercritical 500 MWe case included a 25% biomass co-firing (carbon neutral) case. For both cycles, a 100% Powder River Basin coal firing case was used for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water pre-heating. Unique to the SPOC process, the boilers are pressurized and arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the moisture in the flue gas is condensed, leaving the bottom of the DCC at a sufficiently high temperature such that it can be used for boiler feed water pre-heating, improving plant thermal efficiency. Following drying and purification, CO2 in the flue gas is at the purity required for storage or utilization. The performance data were obtained from process modelling via Aspen Plus®. The stream data from Aspen Plus® were used as an input for the AACE Class 5 cost study. Ultimately, the capital costs, Levelized Cost of Electricity (LCOE), and cost of CO2 captured and avoided were obtained. The HHV efficiency of the carbon negative 550 MWe supercritical SPOC case (34.8%) was clearly above those reported by NETL for the BECCS baseline cases of supercritical pulverized coal with capture (B12B, 31.5%) and the 49% biomass co-firing case with capture (PA3, 29.2%). The HHV efficiency of the carbon-negative subcritical plant is also higher than the subcritical baseline PC plant with capture (case B11B.95) presented by NETL (32% vs 29.7%). The LCOE for the SPOC 100% biomass case was similar to the LCOE for the BECCS 49% biomass with carbon capture case ($147/MWh), and the SPOC carbon neutral case LCOE was lower ($110/MWh) than the cost for the NETL baseline SC coal firing case with 90% carbon capture ($114/MWh).

Magalhaes, Duarte↗

Creative absorber design and optimization for CO 2 capture with aqueous piperazine

The Texas Carbon Management Program is preparing a Front-End Engineering Design (FEED) of the PZASTM (Piperazine with the Advanced Stripper TM ) for CO 2 capture at a natural gas combined cycle power plant in West Texas. This paper develops the absorber design for the capture system and studies the operational strategies of the absorber in response to ambient temperature swing. The design uses 2 absorber trains, and each train integrates absorption and a water-wash section in one column. Each column has a cross-section area of 174 m 2 and consists of 3 sections of MellapakPlus® 252Y structured packing. Packing heights for each section are 3, 4.9, and 2.7 m from top to bottom. A pump-around intercooler applied at the bottom bed circulates solvent and eliminates the direct contact cooler. The baseline CO 2 removal rate is 90% and will vary between 78% and 90% with ambient temperature. The system uses air cooling to eliminate cooling water usage. The water balance in the system will be managed by operating the water wash at a high circulation rate (1300 kg/h) to condense water during the night and make up for water loss during the day. Finally, the proposed design reduces the capital cost of the absorber column by minimizing the packing height and eliminating the direct contact cooler (DCC), and improves the energy cost by lowering the pump-around intercooling temperature and increasing the pump-around rate.

03 NATURAL GAS↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Crystalline Silicotitanate Batch Contact Testing with Ba, Ca, Pb, and Sr

Washington River Protection Solutions is working to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. This goal incorporates the design of a Tank Side Cesium Removal system, which filters tank waste supernate to remove suspended solids and then removes Cs by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The 137 Cs-depleted product is intended to be sent to the WTP for vitrification. Processing of actual tank waste supernate showed effectively complete uptake of Sr and Ba by CST and significant uptake of Ca. Further, Campbell et al. (2019) analyzed CST post-column testing and found significant (>1E-2 mmoles/g) uptake of Ca and Pb along with some Ba, Cd, Fe, Sr, and U. This led to concern that selected metals, particularly the +2 cations, Ca, Sr, Ba, and Pb may be consuming Cs exchange sites and possibly reducing CST capacity for Cs. Exchange of +2 cations was assumed to be associated with the M(OH) + species for the metal (M) ion in the caustic solution. A series of batch contact testing was conducted to evaluate the exchange behavior of Ba, Ca, Pb, and Sr onto CST. The Cs exchange behavior was also tested as a benchmark for direct comparisons. The CST was provided in the sodium form by Honeywell UOP, as IONSIV TM R9140-B, Lot 2002009604, 18 x 50 mesh. A <30-mesh aliquot was collected to match the sieve fraction expected for use in upcoming small column test configurations. Kinetic exchange rate and isotherms were measured at metal concentrations benchmarked from the AP-107 tank waste feed composition and as limited by the metal solubility in the alkaline solution. Two simplified matrices were tested: 1) 1.0 M NaOH/4.6 M NaNO 3 and 2) 0.1 M NaOH/5.5 M NaNO 3 ; these matrices represented the expected 5.6 M Na concentration of process feed and served to address the hydroxide concentration effect on exchange behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental measurement of the effective contact angle for solvent/packing interactions in a structured packed column for CO 2 capture

The contact angle is a critical factor for determining the effective mass transfer area for carbon dioxide (CO 2 ) capture via the chemical absorption process in a packed column, and thus the overall capture efficiency of the packed column. Many widely used commercial packings involve microscale features (perforation, corrugation, etc.) that may also affect the wetting behavior. This study proposes a systematic method of using a modified Wilhelmy plate to measure the effective contact angle to characterize the solvent and featured packing interaction. In lieu of computational efforts relying on assumptions guided by semi-informed correlation, the proposed method directly measures the effective contact angle as a function of the solvent and packing thermophysical and hydrodynamic properties. The characterization of the effective contact angle is then integrated in the computational fluid dynamics modeling to reduce uncertainty in the prediction of effective mas transfer area. Experiments were conducted for stainless steel coupons using water and aqueous sodium hydroxide (NaOH) solvent for verification of the proposed experimental protocol. The surface tension of the aqueous NaOH solvent was altered using surfactant and antifoam. The effective contact angle increases with the increased value of the surface tension for flat stainless steel sheets. On the other hand, effective contact angles do not vary in Mellapak coupons for aqueous monoethanolamine (MEA) and NaOH solvent. In this case, surface textures and sheet design play a dominant role in the surface tension of solvents. Furthermore, CO 2 loading has a significant effect on the contact angle for Mellapak coupons. As expected, the contact angle decreases with the increasing temperature of CO 2 capture solvents (MEA, EEMPA). The effective contact angle measurement using the Wilhelmy plate method can provide more accurate and efficient solvents for characterizing the solvent-packing surface interactions. Subsequently, the present method enhances the accuracy of the prediction of the effective mass transfer area in carbon capture by solvent absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Innovative Zero-Liquid Discharge Intermediate-Cold-Liquid Eutectic-Freeze Desalination System

A novel freeze desalination technology is presented for purification of water produced from various industrial processes, including oil and gas extraction. The main innovative idea is introducing a water-immiscible intermediate-cold-liquid (ICL) medium which absorbs the cold from a refrigeration cycle and transfers it to a freezing chamber where it is mixed with brine. The cold ICL enters the freezing chamber at temperatures between -10°C to -30°C. Precooled brine in injected into the freezing chamber and pure water freezes out of the brine upon mixing with the ICL. The rate of freezing inside the chamber is controlled by adjusting the flow rate of the cold ICL relative to the inlet brine. Both eutectic freeze and non-eutectic freezing are possible by controlling the temperature of the freezing chamber. The solid-liquid slurry created in the freezing chamber flows to a filter separation unit after passing through a separation column. The ice crystals are separated from the liquid by a rotary filter device. The collected ice is rinsed by a centrifugal unit. The rinsed ice is melted to produce fresh water. The developed technology resolves the issues common to current freeze-desalination systems while offering superior heat transfer performance ascribed to direct-contact between the cooling medium and the brine in addition to producing solid salt and pure water. The system operates under atmospheric pressure. The low operation temperature minimizes the corrosion issues common in systems exposed to brine. Also, due to the low operating temperature, there are no concerns about evaporation of volatile organics from the produced water during the treatment. The developed technology effectively eliminates the use of chemicals for pretreatment of brine. The system can be constructed from commercially available components. Extensive testing using a lab-scale prototype by using synthetic brine and actual produced water with TDS values from 50,000 ppm to 300,000 ppm showed that freshwater could be achieved with relatively small dependency on the quality of the input brine. The quality of the treated water was found to be mainly a function of the duration of the centrifugal process. Treated water with TDS as low as 200 ppm could be achieved in the tests. Thermo-economic modeling coupled with system level thermochemical process model were developed for prediction of the LCOW. The LCOW was predicted to be $\$$0.50 to $\$$0.90 per barrel of produced water. The potential markets for deployment of the technology are the oil and gas, in-land thermoelectric powerplants, RO desalination plants, and mining industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Batch contact testing with variable Na AN-107 and AP-105

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the batch contact testing for tanks AN-107 and AP-105 to help evaluate CST performance on tanks waste supernate after processing it in the ion exchange columns. Batch columns were performed with the wastes at six Na concentrations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Processed Lab Data for Neural Network-Based Shear Stress Level Prediction

Machine learning can be used to predict fault properties such as shear stress, friction, and time to failure using continuous records of fault zone acoustic emissions. The files are extracted features and labels from lab data (experiment p4679). The features are extracted with a non-overlapping window from the original acoustic data. The first column is the time of the window. The second and third columns are the mean and the variance of the acoustic data in this window, respectively. The 4th-11th column is the the power spectrum density ranging from low to high frequency. And the last column is the corresponding label (shear stress level). The name of the file means which driving velocity the sequence is generated from. Data were generated from laboratory friction experiments conducted with a biaxial shear apparatus. Experiments were conducted in the double direct shear configuration in which two fault zones are sheared between three rigid forcing blocks. Our samples consisted of two 5-mm-thick layers of simulated fault gouge with a nominal contact area of 10 by 10 cm^2. Gouge material consisted of soda-lime glass beads with initial particle size between 105 and 149 micrometers. Prior to shearing, we impose a constant fault normal stress of 2 MPa using a servo-controlled load-feedback mechanism and allow the sample to compact. Once the sample has reached a constant layer thickness, the central block is driven down at constant rate of 10 micrometers per second. In tandem, we collect an AE signal continuously at 4 MHz from a piezoceramic sensor embedded in a steel forcing block about 22 mm from the gouge layer The data from this experiment can be used with the deep learning algorithm to train it for future fault property prediction.

15 GEOTHERMAL ENERGY↗

Small to Full Height Scale Comparisons of Cesium Ion Exchange Performance with Crystalline Silicotitanate

The U.S. Department of Energy’s (DOE) Hanford Site houses 56 million gallons of high-level radioactive waste generated from plutonium production from 1944 to 1988. The supernatant waste, currently stored in underground tanks, is intended to be vitrified following filtration and 137 Cs removal at the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Vitrification Facility. The WTP Pretreatment Facility will not be operational for several years. The Tank Side Cesium Removal (TSCR) system is a technology demonstration that will remove cesium from tank waste supernate to support directly feeding LAW to the vitrification facility. The 137 Cs removal is important to meet the WTP LAW contract specification and ultimately for creating a contact-handled waste form. The waste acceptance criteria (WAC) limit for the WTP LAW Facility is <3.18E-5 Ci 137 Cs per mole Na. The TSCR system is skid mounted and employs two key technologies: dead end filtration for solids removal and ion exchange (IX) for cesium removal. Filtration is necessary to protect the functionality of the IX columns. The IX process utilizes sodium form crystalline silicotitanate (CST) IX media produced by UOP Honeywell, LLC (Des Plaines, IL) under the product name IONSIV R9140-B, 18 x 50 mesh, in a lead-lag-polish column configuration. Each column contains a CST bed height of 92 inches and a volume of approximately 157 gallons of CST IX media. The full-scale TSCR operation will run at a residence time of 1.9 bed volumes (BV)/h, which results in a superficial velocity of 7.3 cm/min and a flowrate of ~5 gal/min. Column testing at small (2.5% of the full bed height), medium (12% of the full bed height), and full-height scales has been previously conducted to evaluate process variables and scale up performance of Cs exchange onto the CST. Cesium load performances from various sieve cuts at the small scale indicated that a 30-mesh sieve cut be tested to determine if it better reflects the 12% and full-height column performances at the small scale. Two process flowrates were tested in the small-column configuration with <30-mesh CST and simulant solutions. These tests were compared to full-height column tests at the same residence times to assess CST particle size effect on column scaling. Table S.1 summarizes the observed column performance determined for the two flowrates juxtaposed to the previous work with 5.6 M Na simulant at higher scales (used as benchmarks). The WAC breakthroughs between the small and full-height tests at 1.3 BV/h differed by ~59 BVs. The WAC breakthroughs for small, medium, and full-height tests at 1.8 BV/h were consistent at 240 BVs. The 50% Cs breakthroughs were nominally equivalent for all column tests. The common transition zones and onsets of Cs breakthrough at the 1.8 BV/h tests indicated that the Cs mass transfers were equivalent and thus the <30-mesh CST Cs load performance at the small scale successfully modeled that of the full-height system. It is recommended that the <30-mesh CST be used in subsequent 10-mL CST bed tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗