Green and durable engineered cementitious composites (GD-ECC) with recycled PE fiber, desert sand, and carbonation curing: Mixture design, durability performance, and life-cycle analysis
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Proton-exchange-membrane fuel cells (PEMFCs) are clean and sustainable mobile power sources for transportation. Recently, their deployment in heavy-duty vehicles (HDVs) has attracted growing interest owing to their high energy scalability and lower infrastructure requirements. However, to meet the stringent requirements for efficiency and long-term durability for HDV applications, PEMFCs typically employ a relatively high platinum group metal (PGM) loading (>0.2 mg PGM /cm 2 ). This elevated PGM loading significantly increases the stack and system costs, surpassing the U.S. Department of Energy (DOE) target of $\$ 60$/kW for commercial viability. Reducing PGM loading while maintaining performance and durability remains a central challenge for HDV fuel cells. Here we exploit metal oxide–Pt interactions and utilize the strong CeO x –Pt interaction to design a CeO x @Pt catalyst structure with exceptional durability. At a low total PGM loading (0.1 mg PGM /cm 2 ), the CeO x @Pt/C catalyst demonstrates high fuel cell performance (8.8 kW/g PGM ) and stability (power retention >90%) after the challenging HDV durability testing (90,000 accelerated-stress-test cycles). With the CeO x @Pt/C catalyst, we showcase over 70% reduction in Pt cost from the M2FCT target (to $\$ 9$/kW), highlighting its promising potential for enabling stable and cost-effective fuel cell systems for heavy-duty applications.
Abstract The chemical durability of perfluorosulfonic acid (PFSA) membranes is a topic of growing interest to meet Department of Energy (DOE) durability targets for heavy‐duty vehicle (HDV) applications. State‐of‐the‐art membranes like Nafion, rely on the use of cerium, heteropolyacids, and other inorganic additives to increase PFSA chemical durability. A less explored avenue for the oxidative stabilization of PFSA and hydrocarbon membranes is the use of organic antioxidants. No reversible organic antioxidant has been demonstrated to date which can enhance membrane lifetime by factors comparable to cerium. Here, ellagic acid (EA) is demonstrated as a promising radical scavenger for PFSA's. It is found that the incorporation of EA enhances the chemical durability of Nafion by 160%. EA, when incorporated with cerium as an electron donorenhances Nafion durability by at least 80% compared to a membrane incorporated with just cerium in DOE‐defined durability tests. EA is found to be reversible in acidic conditions like those of fuel cells and its reversibility could be further enhanced by the use of suitable co‐antioxidants.
Electrochemical CO 2 reduction is a promising conversion process for producing value-added fuels and chemicals from electricity and CO 2 as a sustainable carbon feedstock to domestically produce fuels and chemicals from industrial waste. Having reached industrially viable performance metrics with small-scale CO 2 electrolysis cells, the field must now increasingly focus on extending the device durability of large stacks to achieve equivalent metrics for 35,000+ hours to decrease maintenance and capital costs. Reported device lifetimes have increased in recent years, with the longest stability studies for CO, ethylene, and formic acid production being published in 2024–2025 with operation times of 4500, 1000, and 5200 h, respectively. Unfortunately, significant extension of the device durability is still required. Here, we provide an overview of ion-exchange membranes (IEMs) and provide insight into the variety of degradation mechanisms that must be overcome to enable the community to meet durability targets. In an effort to accelerate the extension of device lifetimes, we propose a general approach for characterizing CO 2 electrolysis cell degradation before and after durability testing to better elucidate the mechanisms and failure modes of IEMs in zero-gap cells. Furthermore, we encourage the adoption of operando characterizations in tandem with accelerated stress and durability tests, postulating that their combined applications will be increasingly valuable. We hope that this perspective motivates future durability studies to evaluate degradation across the entire electrolysis cell.
Predicting the moisture durability of building envelope components remains challenging due to multiple influencing factors, including material selection, assembly positioning, local climate conditions, air tightness, interior environment, and construction quality. Building codes increasingly emphasize energy efficiency through enhanced insulation and tighter envelopes but offer limited guidance on moisture durability considerations. Consequently, builders face uncertainty, particularly as new materials and assemblies enter the market.The Building Science Advisor (BSA) is a free, web-based expert system developed to address these challenges by providing actionable insights into the moisture durability and energy efficiency of both new and retrofit wall designs. Recently updated, we are now providing version 3.0 of the tool. BSA features significant user interface improvements, enhancing navigation and user interaction through a refreshed, intuitive design. Additionally, the tool incorporates a newly developed database containing pre-simulated wall assembly cases, significantly reducing response times and improving the accuracy of moisture durability assessments. Furthermore, the updated BSA includes moisture content as a performance criterion, providing users with a more comprehensive understanding of moisture-related durability risks. These enhancements enable rapid, reliable assessments tailored to specific climate zones and local building practices. BSA continues to offer targeted guidance on wall retrofit scenarios and delivers access to an expanded library of location-specific building science resources.This paper describes these key updates, highlighting the enhanced features, expanded capabilities, and overall improvements to user experience and educational content. The paper includes a demonstration that illustrates how the revised BSA effectively supports practitioners in designing durable, energy-efficient building envelope assemblies.
Proton exchange membrane fuel cells (PEMFCs) are expected to play a pivotal role in decarbonizing the transportation sector, and particularly heavy-duty vehicles (HDVs). However, improvements in durability are needed for PEMFCs to compete with state-of-the-art power sources for HDVs. Here, we examine how catalyst layer (CL) cracks that are engineered affect the CL durability by using patterned silicon templates to control the CL crack density at the micrometer scale. Electrochemical analyses show that the initial PEMFC performance is relatively unaffected by crack density, but the performance after durability testing was strongly affected. Specifically, CLs with high crack density showed higher performance relative to CLs without cracks after application of a carbon corrosion accelerated stress test. Electrochemical analyses coupled with X-ray computed tomography and scanning transmission electron microscopy with energy dispersive X-ray spectroscopy showed that the cracks provide shorter oxygen diffusion pathways to reaction sites, leading to decreased oxygen transport resistance. Additionally, we observed that the catalyst durability is unaffected by cracks. Our results provide a mechanistic explanation of the role of cracks in CL durability.
Proton-conducting solid oxide electrolysis cells (P-SOECs) are a promising technology for cost-effective and efficient production of green hydrogen. Breakthroughs in materials development, optimization of cell structure, and achievement of high performance and durability are essential to significantly increase the commercial competitiveness of these technologies. The main objective of this project is to gain scientific knowledge for the rational design, fabrication, and demonstration of a robust, highly efficient, and low-cost SOEC technology based on a proton-conducting electrolyte membrane for hydrogen production. We focused on better understanding the degradation mechanisms of proton-conducting electrolytes, air electrodes, and catalyst materials under electrolysis mode to develop an effective strategy for rationalizing new materials that are vital for enhancing cell performance and durability. The scope includes enhancing the performance and durability of the electrolyte and electrode materials under realistic operating conditions, developing highly active and robust catalysts to minimize electrode losses while improving tolerance to contaminant poisoning, revealing the mechanism of enhanced activity and stability of the catalyst, and understanding the underlying degradation mechanisms. In addition, various characterization techniques were employed to gain a fundamental understanding of the materials’ behavior and their impact on cell performance, providing vital information to guide materials discovery and cell design. After defect chemistry engineering, the optimized donor and acceptor co-doped electrolytes BaMo/W 0.03 Ce 0.71 Yb 0.26 O 3-δ (BM/W03) showed substantially improved chemical stability against high concentrations of CO 2 and H 2 O compared to the state-of-the-art electrolyte (BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ , BZCYYb1711) while maintaining comparable ionic conductivity and ionic transference number. To bypass the inherent trade-off between conductivity and chemical stability, we fabricated a bi-layer electrolyte composed of BZCYYb1711 coated with a highly-stable thin layer of BaHf 0.83 Yb 0.17 O 3-δ (BHYb). This bi-layer electrolyte displayed excellent chemical stability against high concentration CO 2 ; there was no detectable formation of BaCO 3 after exposure to 97% CO 2 (with 3% H 2 O) at 500 °C for 1000 hours and the rate of degradation in resistance was about 0.4% per 1,000 hours (kh). In contrast, the same BZCYYb1711 electrolyte without a BHYb coating degraded significantly under the same testing conditions; the degradation rate was increased to 5.1%/kh. In addition, a triple conducting air electrode Ba 0.9 Pr 0.1 Hf 0.1 Y0.1Co 0.8 O 3-δ (BPHYC) was developed by heavily doping transition metal ions into a proton-conducting material. This air electrode material, composed of 3 distinct phases, exhibits superior electrocatalytic activity due to the synergistic effect from the three component phases. Moreover, an active and durable catalyst, La 2 Ni 0.5 Fe 0.5 O 4+δ (LNF), was developed, showing excellent catalytic activity and contaminant tolerance, with a degradation rate of only 0.49%/kh when exposed to high concentrations of steam and Cr. Finally, single cells were constructed from the best electrolytes, electrodes, and catalyst coatings developed in this project. These cells demonstrated superior high current density at a given cell voltage, high roundtrip efficiency, and remarkable durability (up to 1000 hours of operation).
Phosphate glasses have a range of applications including as hosts for immobilizing radioactive wastes. Studies have shown that addition of iron and/or aluminum oxides can drastically improve the chemical durability of phosphate glasses where the accurate measurement of chemical durability is one of the most important factors for determining the long-term viability of a given waste form. However, due to inconsistencies with the experimental methods used to generate chemical durability data, comparing and interpreting such data is a tedious task. These variables include the temperature of the test, the specimen form (e.g., coupon, particles), the pressure of the test (e.g., atmospheric pressure, elevated pressure in an autoclave), the exposure time, the exposure medium, and how the loss is documented (e.g., total mass lost, normalized elemental release). This review paper summarizes a large collection of chemical durability tests on aluminophosphate glasses in various studies. In addition, the effects of different oxides on the properties of phosphate glasses are summarized.
Biomass Carbon Removal and Storage, or BiCRS, pathways use plants or algae that remove carbon dioxide from the atmosphere through photosynthesis and store it underground or in long-lived products. While some BiCRS approaches generate an energy product, all BiCRS approaches generate a carbon product. A new subset of BiCRS approaches focus on the storage of these raw or converted carbon products for generation of carbon credits. However, the durability of these approaches is highly variable as carbon products vary widely in their “form” and the conditions of their “fate.” We organize our thinking about carbon products and their durability around these two primary axes. The durability of carbon product “forms” is mediated by chemical recalcitrance and ranges substantially across agricultural residues, municipal solid waste, woody biomass, and nongaseous products of thermochemical conversion (e.g., biochars and bio-oils). Meanwhile, terrestrial storage “fates” vary in the mechanism employed to stall decay, including surface storage, dry storage, shallow anoxic storage, and deep or geologic anoxic storage (or injection). Each mechanism has different implications for suitability with different feedstock forms as well as long-term risks. We present a framework for assessing durability of solid or liquid raw and conversion carbon products under terrestrial storage fates, highlighting knowns, unknowns, and research priorities moving forward.
Device durability remains a significant challenge in photoelectrochemical (PEC) water splitting under ambient conditions. Yet, a lack of understanding of the test configuration and applied bias effects continue to hinder progress. In this study, we differentiate two-electrode (2E) and three-electrode (3E) configurations for evaluating PEC material durability, focusing particularly on their impacts on photoabsorber solid-state operating conditions. Our results underscore the fallacy of inferring 2E device stability from durability measurements performed solely in 3E configurations. Unmeasured and often misunderstood total circuit bias in 3E tests moderates material degradation, leading to the overestimation of photoelectrode stability compared to short-circuit operation. We demonstrate how the photoabsorber's operating voltage critically governs charge separation, surface stability, and degradation mechanisms during PEC operation. With these findings, we propose a standardized framework for conducting more reliable 3E durability experiments that simulate unassisted performance to help accelerate the development of robust, stable materials for solar-driven water splitting.
Proton Exchange Membrane (PEM) fuel cells are a suitable electrochemical power source for heavy duty vehicle (HDV) applications due to their high efficiency and durability. The cathode of the fuel cell uses a higher geometric loading of platinum (∼0.2 to 0.4 mg Pt /cm 2 ) for the electrocatalysis of the kinetically sluggish Oxygen Reduction Reaction (ORR) which requires higher weight percent loading of the metal (∼50%) on the carbon support to decrease the catalyst layer thickness and hence, the reactant transport losses. The conventionally used supports for platinum catalyst, such as the KetjenBlack TM type high surface area carbon (HSC) features limited mesopore area for the dispersion of Pt nanoparticles leading to increased aggregation and poor durability. Here, we show a new class of carbon materials known as the Engineered Catalyst Support (ECS) developed by Pajarito Powder with higher mesopore fraction for the dispersion of higher weight percentage of Pt nanoparticles. ECS materials can disperse up to 50% Pt by weight of the catalyst thereby enabling lower catalyst layer thickness with higher performance retained after durability test. A comprehensive set of physico-chemical and electrochemical studies in membrane electrode assembly (MEA) are reported to understand the performance and durability of Pt/ECS catalysts.
The low-activity waste (LAW) fraction of Hanford tank waste will be converted to glass at the Waste Treatment and Immobilization Plant (WTP) and disposed on the Hanford site. The chemical durability of LAW glasses has been researched for decades to satisfy contract requirements. Most LAW glass durability data has been generated on non-radioactive simulant glasses fabricated via crucible melts. These non-radioactive glasses were chosen due to safety and cost reasons with confidence that radioactive waste glasses would exhibit similar behavior. To reduce the risk of significant differences in laboratory test response data between WTP melter waste glass and simulant glass, Product Consistency Tests (PCT, i.e., ASTM C1285-21) and Environmental Protection Agency (EPA) 1313 durability tests were performed on actual and simulant LAW glasses fabricated using laboratory-scaled melters. Actual and simulant glass durability test results are presented and statistically compared. Finally, differences in test responses were found to be within experimental uncertainty.
Reducing reliance on perfluoroalkyl substances (PFAS) in proton-exchange membrane fuel cells requires hydrocarbon ionomers that combine high performance with long-term durability, a persistent challenge in catalyst-layer design. Here, we identify oxidation-driven ionomer-catalyst interfacial degradation as a dominant failure pathway in hydrocarbon ionomer-bonded cathodes and introduce an adsorption-engineering strategy to overcome this limitation. The comparison of a commercial sulfonated poly(phenylene) (Pemion) with structurally engineered sulfonated poly(fluorene)s demonstrated that electrode durability is governed by the interplay between ionomer adsorption strength and resistance to oxidative degradation on carbon-supported Pt catalysts. A poly(fluorene) ionomer with mobile alkyl sulfonic acid groups forms resilient interfaces, delivering 1.28 A cm−2 at 0.65 V under fully humidified H2/air conditions (80°C and 150 kPaabs), comparable to Pemion. After 90,000 accelerated potential cycles, the poly(fluorene)-bonded cathode exhibits significantly improved durability, with only 29% performance loss compared to 58% for Pemion; further molecular refinement reduces the loss to 17%, approaching that of Nafion-bonded cathodes (14%). These findings establish adsorption-engineered ionomer design that decouples interfacial anchoring from oxidative degradation as a general strategy for achieving durable, high-performance PFAS-free PEM fuel cell electrodes.
Abstract Green hydrogen, produced via water electrolysis using renewable electricity, will play a crucial role in decarbonizing industrial and heavy‐duty transportation sectors. Anion exchange membrane water electrolyzers (AEMWEs) can overcome many of the performance and cost limitations of incumbent technologies, however, still suffer from durability challenges due to oxidative instability of anion‐exchange ionomers. Herein, the use of an electro‐active porous transport layer as anode (PTL‐electrode) is demonstrated to enable efficient and durable AEMWEs. The stainless‐steel PTL‐electrodes are shown to have superior performance and durability compared to traditional catalyst layers containing ionomer and nanoparticle catalysts. An AEMWE cell operating at 2 A cm −2 for over 600 h exhibited a degradation rate of just 5 µV h −1 . During operation, the surface composition of the stainless steel transforms into a mixture of iron and nickel oxyhydroxides, contributing to enhanced oxygen‐evolution reaction activity. The combination of experimental work and modeling elucidates how the bulk structure of the PTL‐electrode offers an additional design dimension to further improve electrolyzer performance. Lastly, a surface modification strategy is applied to a PTL‐electrode to achieve an even higher performing AEMWE (2.3 vs 2.0 A cm −2 at 1.8 V). Overall, this work lays out pathways toward more efficient, durable, and affordable AEMWEs.
NiFeO x materials are known as among the most active catalysts toward oxygen evolution reaction (OER) for hydrogen generation in alkaline media. Nevertheless, the long-term durability of NiFeO x catalysts for OER is still too far to the industrial application. Herein, we prepared a NiFeReO x catalyst with single-site Re dopants and observed that the single-site Re dopants could significantly enhance the durability without compromising the activity. A cell voltage of 1.82 V without iR correction is noted at the current density of 3000 mA cm –2 in anion-exchange membrane water electrolyzer (AEMWE) with NiFeReO x catalyst, and a very small degradation is observed under 2000 and 1000 mA cm –2 , which remarkably outperforms the pristine NiFeO x . Additionally, the overpotential of 305 mV at 10 mA cm –2 is achieved with the NiFeReO x catalyst, which is lower than 50 mV compared with the pristine NiFeO x catalyst, together with a smaller Tafel slope of 54.3 mV dec -1 . The boosted OER durability and activity of the NiFeReO x catalyst could be attributed to the strong electron-withdrawing property of Re 7+ single atoms leading to the electronic structure optimization and stabilization of Ni/Fe active sites. Our insights propose a new path for designing NiFeO x catalysts with high durability and activity toward OER.
Proton exchange membrane fuel cells (PEMFCs) are a promising zero-emission power source for heavy-duty vehicles (HDVs). However, long-term durability of up to 25,000 h is challenging because current carbon support, catalyst, membrane, and ionomer developed for traditional light-duty vehicles cannot meet the stringent requirement. Therefore, understanding catalyst degradation mechanisms under the HDV condition is crucial for rationally designing highly active and durable platinum group metal (PGM) catalysts for high-performance membrane electrode assemblies (MEAs). Herein, we report a PGM catalyst consisting of platinum nanoparticles with a high content (40 wt %) on atomic-metal-site (e.g., MnN 4 )-rich carbon support. MEAs with the Pt (40 wt %)/Mn–N–C cathode catalyst achieved significantly enhanced performance and durability, generating 1.41 A cm –2 at 0.7 V under HDV conditions (0.25 mgPt cm –2 and 250 kPa abs pressure) and retaining 1.20 A cm –2 after an extended and accelerated stress test up to 150,000 voltage cycles. Electron microscopy studies indicate that most fine Pt nanoparticles are retained on or/and in the carbon support covered with the ionomer throughout the catalyst layer at the end of life. During the long-term stability test, the observed electrochemical active surface area reduction and performance loss primarily result from Pt depletion in the catalyst layer due to Pt dissolution and redeposition at the interface of the cathode and membrane. Importantly, the first-principle density functional theory calculations further reveal a support entrapment effect of the Mn–N–C, in which the MnN 4 site can specifically adsorb the Pt atom and further retard the Pt dissolution and migration, therefore enhancing long-term MEA durability.
Platinum (Pt) is the most active catalyst for oxygen reduction reaction; however, its activity still requires a significant increase to meet the demands of practical applications. To enhance the catalytic activity, alloy catalysts like platinum-cobalt (Pt-Co), are being extensively investigated. However, Co leaching from the Pt-Co alloy remains a significant concern. Evaluating the durability of Pt-Co alloy catalyst is further complicated by variations in Co leaching, which affects both the observed performance and durability. This variability often arises from an overlooked factor: choice of the inactive area of the membrane electrode assembly (MEA) used during the evaluation. This study examines the critical role of membrane inactive area on the performance loss observed during durability testing of Pt-Co alloys. Our findings indicate that a large membrane inactive area reduces the impact of Co leaching on performance and durability, up to 200 mA cm −2 difference in performance is observed between large and small inactive area MEA at 0.7 V for dry conditions, and more Co is retained in the active area of MEA for smaller inactive areas which is responsible for larger performance losses.
While significant advances have been made and early commercial fuel cell light-duty vehicles (LDVs) are starting to be produced, fuel cells in the heavy-duty-vehicle (HDV) transportation sector (including trucks, long-haul semitrailers, maritime, trains, etc.) are nascent, despite the fact that advantages of fuel cells compared to both diesel and electric powertrains are very compelling in terms of emissions, charging time, efficiency, power-to-weight ratio, among others. However, the fuel-cell technology for HDVs requires a paradigm shift in fuel-cell research and development compared to LDVs, where the emphasis becomes efficiency and improvements in durability instead of a focus on increased power densities and lower cell costs. Heavy-duty applications require significantly longer vehicle lifetimes (>25,000 hours/1,000,000 miles for heavy-duty trucks), and therefore require improved fuel cell durability compared to light-duty vehicles. In 2020, HFTO formed the Million Mile Fuel Cell Truck Consortium (M2FCT) that includes a core team of five national laboratories to overcome durability and efficiency challenges in PEMFCs for heavy-duty applications with an initial focus on long-haul trucks. While targets and testing protocols have been developed for light-duty vehicles, the same level of targets and testing protocols have not been established for heavy-duty transportation. With operational times of greater than > 25,000 hours required, the need for well-developed accelerated stress tests (ASTs) is amplified. Results from these ASTs demonstrate the need for more durable electrode layers and well-controlled potential variations. Finally, this presentation will provide an overview of the DOE's Fuel Cell R&D approach, highlighting past and current activities, as well as strategies to enable fuel cell competiveness for heavy-duty applications.