Using Computational Fluid Dynamics of Wind Simulations Coupled With Weather Data to Calculate Dynamic Line Ratings

Dynamic line rating is a technology that allows for the rating of electrical conductors to be calculated based on local weather conditions rather than using ”worst-case” assumptions of weather conditions. The static ratings are typically based on weather conditions that are conservative in nature, and thus dynamic line rating may provide room to increase the current capacity. The local weather conditions may estimate conditions more accurately near the transmission lines accounting for terrain such as nearby hills. One way to estimate the local weather conditions is through the use of computational fluid dynamics. The results of a wind field simulation can be coupled with sparsely located weather stations to provide an accurate assessment of the wind speeds along the path of the conductor. Here, the wind field simulations are calculated using a steady state Reynolds-averaged Navier-Stokes model. These results along with local solar radiance measurements can be used to provide estimates of the steady state ampacity with the standard IEEE equations. An advanced test case for this process involves performing these simulations in a complex terrain, Hells Canyon, the deepest river gorge in North America. The results show that by using weather-based sensors without considering localized wind conditions, the available ampacity may be over-predicted significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Line Rating: Research and Policy Evaluation

Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of electrical conductors to be increased based on local weather conditions. Overhead lines are conventionally given a conservative rating based on worst case scenarios. We demonstrate that observing the conditions in real time leads to additional capacity and safer operation. This paper provides a report of a pioneering scheme in the United States of America in which DLR has been applied. Thereby, we demonstrate that observing the local weather conditions in real time leads to additional capacity and safer operation. Secondly, we discuss limitations involved. In doing so, we arrive at novel insights which will inform and improve future DLR projects. Third, we provide a policy background and discussion to clarify the technology’s potential and identifies barriers to the imminent adoption of dynamic line rating systems. We provide suggestions for regulatory bodies about possible improvements in policy to encourage adoption of this beneficial technology.

17 WIND ENERGY↗

Forecasting Dynamic Line Rating with Spatial Variation Considerations

Dynamic line rating (DLR) is a technology that allows the ampacity of an electrical conductor to be calculated using real-time or forecasted weather conditions. Historically, the ampacity of a conductor has been determined using a static line rating method which assumes conservative weather assumptions. Therefore, not only can DLR give a more accurate measurement of the true ampacity of a conductor, but it can also increase its ampacity during weather conditions with greater thermal mitigations. The two primary cooling factors in the ampacity calculations are wind speed and direction. In complex terrain, wind speed and direction can have large variations over short distances. Therefore, accurately identifying the limiting span of a transmission line requires high spatial resolution of the wind along its path. One solution is to install dense weather stations along their path, though this can become costly over long distances. Therefore, researchers have investigated the use of Computation Fluid Dynamic (CFD) simulations to accurately compute the wind field along the path of a transmission line and use these results to identify the limiting section of the conductor. This work presents a case study that evaluates the coupling of CFD simulations and forecasted weather simulations using the High-Resolution Rapid Refresh (HRRR) model points over a 2-year span within a region in south eastern Idaho. The primary goal of the work is the evaluation of the number of HRRR model points used, i.e., weather stations, along the path of the line and the accuracy of the resulting ampacity. This was done using 4, 10, 17, 26, and 35 HRRR model points along two transmission line paths. The results indicate that as the number of model points are increased, the DLR ampacity of the lines decrease, yet converge as more points are added and demonstrate little change with additional HRRR points. It is expected that these results can help transmission line operators identify the number of weather stations that must be installed when coupled with CFD simulations and DLR ampacity to ensure accurate ratings and safe operations.

17 WIND ENERGY↗

Forecasting Dynamic Line Rating with Spatial Variation Considerations

Dynamic line rating (DLR) is a technology that allows the ampacity of an electrical conductor to be calculated using real-time or forecasted weather conditions. Historically, the ampacity of a conductor has been determined using a static line rating method which assumes conservative weather assumptions. Therefore, not only can DLR give a more accurate measurement of the true ampacity of a conductor, but it can also increase its ampacity during weather conditions with greater thermal mitigations. The two primary cooling factors in the ampacity calculations are wind speed and direction. In complex terrain, wind speed and direction can have large variations over short distances. Therefore, accurately identifying the limiting span of a transmission line requires high spatial resolution of the wind along its path. One solution is to install dense weather stations along their path, though this can become costly over long distances. Therefore, researchers have investigated the use of Computation Fluid Dynamic (CFD) simulations to accurately compute the wind field along the path of a transmission line and use these results to identify the limiting section of the conductor. This work presents a case study that evaluates the coupling of CFD simulations and forecasted weather simulations using the High-Resolution Rapid Refresh (HRRR) model points over a 2-year span within a region in south eastern Idaho. The primary goal of the work is the evaluation of the number of HRRR model points used, i.e., weather stations, along the path of the line and the accuracy of the resulting DLR ampacity. This was done using 4, 10, 17, 26, and 35 HRRR model points along two transmission line paths. The results indicate that as the number of model points are increased, the DLR ampacity of the lines decrease, yet converge as more points are added and demonstrate little change with additional HRRR points. It is expected that these results can help transmission line operators identify the number of weather stations that must be installed when coupled with CFD simulations and DLR ampacity to ensure accurate ratings and safe operations.

17 WIND ENERGY↗

Dynamic Line Rating Forecast Time Frames

As dynamic line ratings (DLR) are used to support different use cases, the preferred data source varies according to the forecast horizon. The below guidance is one possibility to utilize weather forecasting. Note that the time-periods of forecasts and spatial resolution may be subject to change as National Oceanic and Atmospheric Administration (NOAA)/National Weather Service (NWS) periodically upgrades its forecast models and data servers. Moreover, Persistence/ML Observations advances in analytics may justify combining data sources for more reliable DLR forecasts. The list below gives a time period (t) followed by possible guidance for data in that interval.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling computational fluid dynamics with the high resolution rapid refresh model for forecasting dynamic line ratings

This study looks at forecasted dynamic line ratings in southern Idaho by using data from the High Resolution Rapid Refresh (HRRR) model for forecasted weather conditions. The HRRR model can provide accurate 18- hour forecasts with a 15-minute temporal resolution. Typical static ratings used for over head transmission lines use overly conservative assumptions for local weather conditions, such as using the maximum solar irradiance or temperature measured during the summer combined with low wind speed for an entire season. The HRRR forecast model used here has a high spatial resolution to provide local forecast conditions along the entire length of a transmission line. The area that is of interest in this study is in southern Idaho spanning a total of 15,000 square kilometers. The forecasted weather data is coupled with a computational fluid dynamics model of the wind in the region to improve the resolution to an even finer scale for resolving local convective cooling rates on each individual transmission line midpoint span. This high fidelity approach can be used to find the minimum ampacity limit across all given midpoints of a transmission line to determine the absolute minimum to be used for the line rating. The ability to increase the line rating above the conservative static approach with the forecasted weather data provides a large potential to alleviate congestion and provide data for the utility market transactions. Furthermore, this study shows that for the region of interest, using forecasted weather data coupled with CFD modeling will calculate DLR ampacity rating above static about 90% of the time, with only a small relative error in the forecasted ampacity over time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feasibility and Prospects of the High Resolution Rapid Refresh Model For Dynamic Line Rating

The ampacity of transmission lines is defined as the maximum amount of current the conductor can safely carry. It is necessary for transmission line operators to apply ampacity limits due to the thermal properties of the conductor. Dynamic Line Rating (DLR) is a technology and technique that uses the environmental conditions or a set of the conditions to calculate the ampacity of the conductor. The way the DLR is calculated has depended upon some amount of physical technology to implement the solution. The High Resolution Rapid Refresh (HRRR) Model is an atmospheric model that may provide enough resolution to perform dynamic line rating without any hardware at all. The objective is to use this model to perform Dynamic Line Rating. This will solve two of the most pervasive problems in Dynamic Line Rating, how to instrument a transmission line hundreds of miles long and then how to predict near future ampacity sufficient for transmission operators to effectively use, This technique will use the Idaho National Laboratory site as the test location for analysis. The High Resolution Rapid Refresh model is a reliable, freely available, and well-maintained weather forecasting model for the entire United States of America. The model provides enough special resolution that additional local weather monitoring devices at location are not necessary to conduct dynamic line rating. The HRRR ratings are lower on average than the locally measured ratings which allows for an additional margin of safety. The adoption of using purely digital methods for dynamic line rating could allow for wide scale adoption of the technology with very little overhead expenditure of implementation.

17 WIND ENERGY↗

Dynamic Line Rating Oncor Electric Delivery Smart Grid Program

Electric transmission lines are the lifeline of the electric utility industry, delivering its product from source to consumer. This critical infrastructure is often constrained such that there is inadequate capacity on existing transmission lines to efficiently deliver the power to meet demand in certain areas or to transport energy from high-generation areas to high-consumption regions. When this happens, the cost of the energy rises; more costly sources of power are used to meet the demand or the system operates less reliably. These economic impacts are known as congestion, and they can amount to substantial dollars for any time frame of reference: hour, day or year. There are several solutions to the transmission constraint problem, including: construction of new generation, construction of new transmission facilities, rebuilding and reconductoring of existing transmission assets, and Dynamic Line Rating (DLR). All of these options except DLR are capital intensive, have long lead times and often experience strong public and regulatory opposition. The Smart Grid Demonstration Program (SGDP) project co-funded by the Department of Energy (DOE) and Oncor Electric Delivery Company developed and deployed the most extensive and advanced DLR installation to demonstrate that DLR technology is capable of resolving many transmission capacity constraint problems with a system that is reliable, safe and very cost competitive. The SGDP DLR deployment is the first application of DLR technology to feed transmission line real-time dynamic ratings directly into the system operation’s State Estimator and load dispatch program, which optimizes the matching of generation with load demand on a security, reliability and economic basis. The integrated Dynamic Line Rating (iDLR)1 collects transmission line parameters at remote locations on the lines, calculates the real-time line rating based on the equivalent conductor temperature, ambient temperature and influence of wind and solar radiation on the stringing section, transmits the data to the Transmission Energy Management System, validates its integrity and passes it on to Oncor and ERCOT (Electric Reliability Council of Texas) respective system operations. The iDLR system is automatic and transparent to ERCOT System Operations, i.e., it operates in parallel with all other system status telemetry collected through Supervisory Control and Data Acquisition (SCADA) employed across the company.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Line Rating Study of Concurrent Cooling for a Proposed Wind Farm

This report was prepared for the Wind Energy Technology Office for the FY 2021, quarter 2 deliverable. This details the use of dynamic line rating technology to rate a gen tie-line associated with a proposed wind farm. By utilizing dynamic line rating, the concurrent cooling effect – maximum wind farm power output is coupled with additional cooling on the line – can be used to provide a smaller size conductor for the gen tie line, thus reducing the capital costs.

17 WIND ENERGY↗

Using Computational Fluid Dynamics to Assess Dynamic Line Rating in Southern Idaho

The overall goal of the study is to combine computational fluid dynamics (CFD) simulations with weather data that is collected over a 1-year long period across southern Idaho to calculate the dynamic line ratings (DLR) of several transmission lines. These ratings can be compared to the static rating assumptions to show the potential for additional current carrying capacity along transmission lines through account for additional effects of convective cooling from the wind. The region of interest is quite large, sized at 144 km by 98 km; in order to cover this large region, the CFD simulations are split into four separate regions of over 80 million computational cells each. The weather data that was collected suggest initial assumptions used to make the static ratings were vastly over predicted with regards to summer temperatures and solar irradiance. The weather data is ran through the General Line Ampacity State Solver (GLASS) tool that was developed by Idaho National Laboratory (INL) to parse large quantities of weather data across thousands of transmission midpoint spans in the region. For shorter lines, the dynamic line ratings often show large improvement over static ratings. The case study here shows over 95% of the time DLR values are above static values on the short transmission lines. However, for long lines, a conundrum occurs, where due to the large number of weather stations associated with the line, there is often a single weather station which may read local wind speeds of zero. This often defaults the line rating to be limited by natural convective cooling and does not show as much improvement over static as might be expected from the weather data if DLR calculations are used with a minimum ampacity across all midpoints. Other methods with transient state calculations should be utilized for long lines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Forecasted Dynamic Line Ratings for Regional Transmission Lines

This report was prepared for the Wind Energy Technology Office for the FY 2022, quarter 3 deliverable. This details the use of forecasted dynamic line rating as an improvement over static rating for three transmission lines in three regions of interest. A selection of wind plants across Idaho, the Columbia River Gorge and offshore wind in the NYSERDA territory were modeled for their concurrent cooling effects for dynamic line rating. Regional transmission lines for the wind plant interconnections were determined and a CFD domain was created to determine local wind flows over the lines. A dynamic line rating for each of the lines was calculated for both weather observation data and HRRR model forecast data. The comparison of peaks in the wind power production were compared to the DLR peaks. It was determined that for shorter regional transmission lines, the effect of concurrent cooling that commonly occur with gen-tie lines were still valid. Concurrent cooling effects drop as the length of the regional transmission lines increase in distance from the wind plants. In addition, the accuracy of the forecasted ampacity to the weather observation data for ampacity was assessed. In general, the accuracy was best for the INL region with the NOAA-maintained sites. The Columbia River Gorge and Long Island sites showed similar levels of accuracy for the forecasted DLR. The accuracy levels were around 11% for the INL region, 15% for Columbia River Gorge and 7% for New York Long Island. The higher error for the Columbia Gorge region is likely due to the sparse availability of weather stations available, whereas both the INL site and Long Island are well instrumented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission Line Ampacity Improvements of AltaLink Wind Plant Overhead Tie-Lines Using Weather-Based Dynamic Line Rating

Abstract—Overhead transmission lines (TLs) are conventionally given seasonal ratings based on conservative environmental assumptions. Such an approach often results in underutilization of the line ampacity as the worst conditions prevail only for a short period over a year/season. We presents dynamic line rating (DLR) as an enabling smart grid technology that adaptively computes ratings of TLs based on local weather conditions to utilize additional headroom of existing lines. In particular, general line ampacity state solver utilizes measured weather data for computing the real-time thermal rating of the TLs. The performance of the presented method is demonstrated from a field study of DLR technology implementation on four TL segments at AltaLink, Canada. The performance is evaluated and quantified by comparing the existing static and proposed dynamic line ratings, and the potential benefits of DLR for enhanced transmission assets utilization. For the given line segments, the proposed DLR results in real-time ratings above the seasonal static ratings for most of the time; up to 95.1% of the time, with a mean increase of 72% over static rating.

17 WIND ENERGY↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

Advanced Transmission Technologies – GETs and HPCs Session 1: ATT Foundations and Dynamic Line Ratings (DLRs)

The INL TADA GETs Cohort Session 1, held on November 4, 2025, convened experts to address the integration of advanced transmission technologies, including Grid-Enhancing Technologies (GETs) and High Performance Conductors (HPCs), with a focus on digital assurance challenges. The session highlighted the growing importance of cybersecurity, supply chain transparency, reliability, and business risk management in deploying GETs, especially Dynamic Line Ratings (DLRs). Participants examined how expanded attack surfaces, limited vendor pools, and new regulatory requirements—such as FERC Orders 881, 2023, and 1920—are influencing utilities and technology providers. The workshop underscored the need for cyber-informed engineering, secure-by-design principles, and practical risk management strategies, while fostering collaboration and knowledge sharing among industry peers. Technical discussions covered the evolution from static to dynamic line ratings, complexities of cloud-based architectures, and NERC CIP compliance challenges. The session concluded with a collaborative risk exercise and a preview of future workshops on advanced power flow control and transmission topology optimization, reinforcing the cohort’s commitment to advancing digital assurance in the energy sector.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Risk-Based Distributionally Robust Optimal Power Flow With Dynamic Line Rating

In this paper, we propose a risk-based data-driven distributionally robust approach to investigating the optimal power flow with dynamic line rating. The risk terms, including penalties for load shedding, wind generation curtailment and line overload, are embedded into the objective function. To robustify the solution, we consider a distributional uncertainty set based on the second-order moment, that captures the correlation between wind generation outputs and line ratings, and also the Wasserstein distance, that hedges against data perturbations. We show that the proposed model can be reformulated as a convex conic program. Approximations of the proposed model are suggested, which leads to a significant reduction of the number of the constraints. For practical large-scale test systems, a distributionally robust optimal power flow model with Wasserstein-distance-based distributional uncertainty set and its convex reformulation are also provided. Simulation results on the 5-bus, the IEEE 118-bus and the Polish 2736-bus test systems validate the effectiveness of the proposed models.

distributionally robust optimization↗