At least 19 records

Nature-Inspired Motivation for Developing Self-Healable Electrical Insulation

Polymeric aircraft electrical insulation normally degrade by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Self-healing insulation may be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the material. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, self-healing through establishment of ionic crosslinks allows for multiple healing events to occur as well as achieving full recovery strength under certain thermal environments. Surlyn®, a commercial ionically-crosslinked material, was investigated as a self-healing insulation candidate based on prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was studied to determine if moisture absorption rates in Surlyn® were lower than that of common polyimide insulators. Preliminary data showed that when cut, Surlyn® films lost nearly 60 percent of its original dielectric strength. However, when Surlyn® was cut and subsequently annealed, the films not only re-mended, but also recouped approximately 93 percent of its original dielectric strength, along with 90-97 percent of its mechanical strength.

electrical↗

Thermally-Induced Healing of Electrically-Insulating Ethylene-Octene Copolymers

We report on electrical insulating materials that not only have sufficient mechanical toughness to survive use conditions, but also possess the ability to undergo thermally induced self-repair when damaged. By controlling the cross-link density, a modified ethylene-octene copolymer (EOC) is able to retain its self-healing abilities while also being used at temperatures greater than the original, unmodified polymer. Specifically, an EOC cross-linked with 0.25 wt% dicumyl peroxide affords a material ability to recover 61% of its critical fracture energy — a value similar to thermoplastic EOC. Furthermore, as shown by dielectric spectroscopy, the cross-linked EOC retains good electrically-insulating properties.

Self-healing↗

Self-Healable Electrical Insulation for High Voltage Applications

Polymeric aircraft electrical insulation normally degrades by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Developing self-healing insulation could be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the insulation. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, establishment of ionic crosslinks could allow for multiple healing events to occur with the added benefit of achieving full recovery strength under certain thermal environments. This could be possible if the operating temperature of the insulator is the same as or close to the temperature where ionic crosslinks are formed. Surlyn, a commercial material with ionic crosslinks, was investigated as a candidate self-healing insulator based off prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was also studied to determine if moisture absorption rates in Surlyn were lower than that of common polyimides.

electrical insulation↗

Progresses in Developing Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

Development of the novel patented high voltage insulation system, namely micro-multilayer multifunctional electrical insulation (MMEI) was continued particularly for the future hybrid or all electric aircraft applications. Initially, the concept and feasibility of the MMEI system were successfully demonstrated with its exceptionally high dielectric breakdown voltage via optimizing the multilayer structures of the Kapton® PI films and binder layers such as PFA in terms of individual film thickness and layer configuration. Overall, MMEI structures outperformed most of the state-of-the-art (SOA) polymer insulation materials or structures. Since then, further optimizations and improvement of the system were pursued with specific emphasis on multifunctionalities such as moisture blocking, partial discharge (PD) resistance, durability, etc. Efforts have been also continued to identify the controlling mechanisms for the major improvement in dielectric strength of the MMEI structures via 3-dimensional dielectric failure mode analysis. At the same time, significant progress has been made in scaling up the MMEI structures and assessing their commercial applicability and manufacturability by developing full-scale prototypes of electrical components, such as power cable and bus bar. Overall progresses on the MMEI development to date will be presented in this paper.

Novel Electrical Insulation↗

Thermal and sputtered aluminum oxide coatings for high temperature electrical insulation

Aluminum oxide coatings have been investigated as electrically insulating layers for mounting thin film Pt-Pt/Rh thermocouples on gas turbine blade and vane alloys (MAR M200 + Hf and MAR M509). Thermal oxides were grown directly onto NiCoCrAlY and FeCrAlY coatings on these alloys at temperature between 1300 and 1400 K in oxygen partial pressures 10 to the -7th to 2 x 10 to the 4th Pa. Although these thermal oxides exhibited good adherence, analytical characterizations using electron and optical microscopy, as well as X-ray photoelectron spectroscopy showed that they had defects and impurities which limited their insulating ability. The insulating quality of the coating was greatly improved however by reactively sputtering an aluminum oxide film over the thermal oxide. Results are presented on the electrical performance of the 2-5 micron thick composite layers for temperatures up to 1300 K.

Kreider, K. G.↗

Feasibility of Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

The newly patented micro-multilayer multifunctional electrical insulation (MMEI) system was developed for future electric aircraft applications which critically require lightweight but high voltage (HV), high temperature, and corona or partial discharge (PD) resistant insulation. During the initial development stages, the concept and practicability of the MMEI system were successfully validated with its exceptionally high dielectric breakdown voltages. The multilayer structures were optimized in terms of material type, individual layer thickness, and overall layer configuration along with potential mechanisms identified for its superior performance. Subsequently, scalability, manufacturability, and commercial applicability of the MMEI system were demonstrated with the 1 meter long, 3-phase HV, high power (HP) bus bar prototypes. Two prototypes, one with the conventional SOA insulation system including Mica sheet and the other with an optimized MMEI, were designed, fabricated, and tested successfully. Both prototypes passed both HiPot and PD tests up to the highest test voltage available, 15 kVAC, although the latter showed a slight increase in PD activities at 12.5 kV. However, the prototype with MMEI was 15% lighter or 12% thinner than the other one. Current efforts to significantly enhance the PD resistance of the MMEI system by employing semiconductive shielding layers, which can be also multifunctional, e.g., electromagnetic interference shielding, moisture blocking, heat dissipation, for various HV applications are also discussed in this paper.

Novel Electrical Insulation↗

Feasibility of Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

The newly patented micro-multilayer multifunctional electrical insulation (MMEI) system was developed for future electric aircraft applications which critically require lightweight but high voltage (HV), high temperature, and corona or partial discharge (PD) resistant insulation. During the initial development stages, the concept and practicability of the MMEI system were successfully validated with its exceptionally high dielectric breakdown voltages. The multilayer structures were optimized in terms of material type, individual layer thickness, and overall layer configuration along with potential mechanisms identified for its superior performance. Subsequently, scalability, manufacturability, and commercial applicability of the MMEI system were demonstrated with the 1 meter long, 3-phase HV, high power (HP) bus bar prototypes. Two prototypes, one with the conventional SOA insulation system including Mica sheet and the other with an optimized MMEI, were designed, fabricated, and tested successfully. Both prototypes passed both HiPot and PD tests up to the highest test voltage available, 15 kVAC, although the latter showed a slight increase in PD activities at 12.5 kV. However, the prototype with MMEI was 15% lighter or 12% thinner than the other one. Current efforts to significantly enhance the PD resistance of the MMEI system by employing semiconductive shielding layers, which can be also multifunctional, e.g., electromagnetic interference shielding, moisture blocking, heat dissipation, for various HV applications are also discussed in this paper.

Novel Electrical Insulation↗

Thermally Conductive Melt-Processable Polyimide HBN Micro-Composites for High Temperature Electrical Insulation Applications

Thermoplastic polymers exhibit excellent dielectric properties and manufacturing robustness. These properties mark thermoplastics as competitive material candidates for electrical insulation applications. However, the high-temperature performance of most thermoplastics is insufficient to meet the electrical wiring requirements for next-generation air and space transportation engineering designs, with continuous operation temperature requirements of up to 200 °C among other design requirements. Furthermore, the low thermal conductivity (κ) of polymers as a material class leads to heat trapping within wires which can amplify thermal stresses. As a result, there is a need to investigate candidate thermoplastic systems for their high temperature, dielectric, and κ performance.

polyimide↗

NASA-GRC Research Activities in High Voltage (HV) Electrical Insulation

This presentation gives an overview of recent research activities at NASA Glenn Research Center (GRC). The presentation covers research associated with materials for high voltage aerospace electrical insulation applications.

Aerospace Materials Aerospace electrical insulatio↗

Effects of carbon/graphite fiber contamination on high voltage electrical insulation

The contamination mechanics and resulting failure modes of high voltage electrical insulation due to carbon/graphite fibers were examined. The high voltage insulation vulnerability to carbon/graphite fiber induced failure was evaluated using a contamination system which consisted of a fiber chopper, dispersal chamber, a contamination chamber, and air ducts and suction blower. Tests were conducted to evaluate the effects of fiber length, weathering, and wetness on the insulator's resistance to carbon/graphite fibers. The ability of nuclear, fossil, and hydro power generating stations to maintain normal power generation when the surrounding environment is contaminated by an accidental carbon fiber release was investigated. The vulnerability assessment included only the power plant generating equipment and its associated controls, instrumentation, and auxiliary and support systems.

Garrity, T.↗

A test and instrumentation system for the investigation of degradation of electrical insulating materials

A comprehensive test apparatus has been developed for the evaluation of the effects of thermal cycling, high temperatures and high electric fields on the quality and stability of electrical insulating materials used in spacecraft systems. The system includes a test chamber in which the specimen can be subjected to thermal and electrical stresses encountered in the space environment (temperatures from -50 to 200 C and voltages from 0 to 10 kV rms, respectively) simultaneously. The system instrumentation includes provisions for the measurement of the change in capacitance, the thermal dissipation factor of the material, and complex dielectric constants with changes in temperature, corona intensity and voltages at frequencies from 22 kHz to 70 MHz, as well as the volume and surface resistivities of the materials.

Doreswamy, C. V.↗