Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

X-57 Maxwell High Lift Motor Controller Electromagnetic Interference Test Results

During research and development for NASA’s X-57 Maxwell all-electric aircraft project, the efficiency and power density requirements of its electric propulsion subsystem components were met, but aspects of integrating its powertrain subsystems proved problematic. Electromagnetic interference (EMI) from the cruise motor controller (CMC) was a significant challenge for the project. This problem was exacerbated by the lack of EMI requirements imposed on subsystem powertrain components. This report presents the results of EMI testing of the X-57 high lift motor controller (HLMC) at the NASA Glenn Research Center’s EMI Laboratory. For reference, the conducted emissions are compared to DO–160G and MIL–STD–61G conducted emissions limits. After the EMI test, mitigation of the conducted emissions using lightweight EMI chokes produced at NASA Glenn was evaluated using the Fast Fourier Transform (FFT) capability of an oscilloscope in the hardware development laboratory. This process can contribute to the rapid prototyping of electric powertrain components and EMI filters and improve the likelihood of successful EMI qualification at the component and system levels.

Silicon carbide↗

Crystalline Mesoporous Complex Oxides: Porosity-Controlled Electromagnetic Response

A colloidal--amphiphile--templated growth is developed to synthesize mesoporous complex oxides with highly crystalline frameworks. Organosilane-containing colloidal templates can convert into thermally stable silica that prevents the overgrowth of crystalline grains and the collapse of the mesoporosity. Using ilmenite CoTiO 3 as an example, the high crystallinity and the extraordinary thermal stability of its mesoporosity are demonstrated at 800 °C for 48 h under air. This synthetic approach is general and applicable to a series of complex oxides that are not reported with mesoporosity and high crystallinity, such as NiTiO 3 , FeTiO 3 , ZnTiO 3 , Co 2 TiO 4 , Zn 2 TiO 4 , MgTi 2 O 5 , and FeTi 2 O 5 . Those novel materials make it possible to build up correlations between mesoscale porosity and surface-sensitive physicochemical properties, e.g., electromagnetic response. For mesoporous CoTiO 3 , there is a 3 K increase of its antiferromagnetic ordering temperature, compared with that of nonporous one. Lastly, this finding provides a general guideline to design mesoporous complex oxides that allow exploring their unique properties different from bulk materials.

36 MATERIALS SCIENCE↗

Electromagnetic control of spin ordered Mn 3 qubits: a density functional study

[Mn 3 O(O 2 CMe)(dpd 3/2 )] 2 is composed of two monomers each of which contain three Mn atoms at the vertices of an equilateral triangle. A full analysis of the electronic and magnetic structure of the dimer shows that each Mn atom carries a local spin of S = 2 while other spin states are energetically much higher. This result suggests application for conventional as well as quantum tasks. A detailed analysis of the electronic and magnetic structure of the monomer, on the other hand, suggests that there are three spin states of S = 1, S = 3/2 and S = 2 per monomer which are energetically competitive. Additionally, we found that while monomer–monomer interactions are very weak, the coupling of monomers via covalent linkers affects both the magnetization and electronic energy levels of monomers. In particular, the isolated monomers prefer a ground state with local spin of S = 1 on Mn atoms and an antiferromagnetically ordered structure while the dimers possess a ground state with local spin of S = 2 on Mn atoms and a ferromagnetically ordered structure. The investigation of the polarizability of both monomer and dimer is examined for antiferromagnetically ordered structures which induces a high dipole moment of 0.08 (a.u.) and 0.16 (a.u.) for monomer and dimer, respectively. The energy of the antiferromagnetic structure is also high compared to other spin-electric molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining and controlling the electromagnetic environment for Space Station Freedom

Critical issues facing the SSF electromagnetic compatibility community are discussed focusing on effective utilization of SSF resources to perform overall SSF verification. Attention is also given to management and phases of an Electromagnetic Environment Effects Control Program (EEECP) aimed at producing an electromagnetically compatible station.

Pearson, S. D.↗

Positioning and Microvibration Control by Electromagnets of an Air Spring Vibration Isolation System

Active positioning and microvibration control has been attempted by electromagnets equipped in a bellows-type, air-spring vibration isolation system. Performance tests have been carried out to study the effects. The main components of the system's isolation table were four electromagnetic actuators and controllers. The vibration isolation table was also equipped with six acceleration sensors for detecting microvibration of the table. The electromagnetic actuators were equipped with bellows-type air springs for passive support of the weight of the item placed on the table, with electromagnets for active positioning, as well as for microvibration control, and relative displacement sensors. The controller constituted a relative feedback system for positioning control and an absolute feedback system for vibration isolation control. In the performance test, a 1,490 kg load (net weight of 1,820 kg) was placed on the vibration isolation table, and both the positioning and microvibration control were carried out electromagnetically. Test results revealed that the vibration transmission was reduced by 95%.

Watanabe, Katsuhide↗

Controls-structures-electromagnetics interaction program

A technology development program is described involving Controls Structures Electromagnetics Interaction (CSEI) for large space structures. The CSEI program was developed as part of the continuing effort following the successful kinematic deployment and RF tests of the 15 meter Hoop/Column antenna. One lesson learned was the importance of making reflector surface adjustment after fabrication and deployment. Given are program objectives, ground based test configuration, Intelsat adaptive feed, reflector shape prediction model, control experiment concepts, master schedule, and Control Of Flexible Structures-II (COFS-II) baseline configuration.

Grantham, William L.↗

Gateway Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment

This document is a tailored version of MIL-STD-461, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment, for the Gateway Program. While many of the requirements contained herein correspond with a MIL-STD-461 requirement, some are unique to the Gateway Program in order to meet the specific needs of the program. Nearly all limits are tailored specifically for Gateway elements, systems, and subsystems.

MIL-STD-461↗

Integrated model construction for CO2-EOR monitoring via charged-wellbore casing controlled-source electromagnetics

We present a method for the integrated development of 3D electrical conductivity models for CO2-EOR monitoring with charged wellbore casing controlled-source electromagnetics (CWC-CSEM). The model is constructed through the multiphysics integration of reservoir simulation, seismic, borehole resistivity, and transient EM (TEM) data. The process is performed in two stages. First, a large background conductivity model is constructed from the combination of seismic, borehole, and TEM data. Second, a more detailed and dynamic component of the model is created within the production interval by converting the reservoir simulation parameters to conductivity through Archie’s equation. In this presentation, we demonstrate the complete workflow for building these 3D conductivity site models that can be updated throughout production using the Bell Creek oil field as an example. We then show application of the developed site model to simulating the predicted CWC-CSEM data as one step in the larger problem of reservoir imaging and monitoring of injected CO2 during enhanced oil recovery.

CO2, Sequestration, Monitoring, time-lapse, reserv↗

Time Lapse Charged Wellbore Casing Controlled Source Electromagnetic Surveys for Monitoring Injected Carbon Dioxide

Carbon dioxide (CO2) injection for enhanced oil recovery (EOR) and long-term carbon storage extends the life of an oil field while keeping CO2 out of the atmosphere. Monitoring CO2 migration during EOR operations is critical to maximizing production and detecting unexpected CO2 migration quickly. In this project, we monitor CO2 migration using time-lapse charged well casing controlled source electromagnetics (CSEM) at an active EOR site undergoing CO2 injection. Since the electrical conductivity of the reservoir changes as CO2 displaces other fluids, this novel survey technique aims to monitor CO2 injection effectively and unobtrusively from the surface via electromagnetic field measurements. Of four time-lapse field campaigns spaced over two years, we have completed two. Each campaign consists of a CSEM survey supplemented by magnetotelluric and time-domain electromagnetic surveys. In the CSEM survey, a transmitter delivers alternating current to the subsurface at frequencies from 0.125 Hz to 16 Hz using steel well casings as electrodes. Charged well casing surveys detect deeper conductivity contrasts than surveys that use only surface electrodes, allowing CO2 movement at the depth of the reservoir to be imaged more clearly. We transmit on two well pairs. One pair is oriented in the east-west direction, and the other is oriented in the northeast-southwest direction. Receiver stations measure orthogonal components of the electric and magnetic fields. The measurements are repeated at the same locations in each field campaign. Data differences between campaigns provide information about changes in the electrical conductivity of the subsurface. We present the latest results from this ongoing project, including modeling, survey design, data processing techniques, and preliminary results from the field campaigns.

Magnetic and electrical methods, Geomagnetic induc↗

Using Controlled-Source Electromagnetic (CSEM) for CO 2 Storage Monitoring in the North Dakota CarbonSAFE Project

Conference presentation for International Meeting for Applied Geophysics & Energy (IMAGE), September 26 – October 1, 2021, Denver, CO. Geophysical methods are key for characterizing the geologic formations to store CO 2 and monitor the injected CO 2 over time to ensure containment. In the integrated multimeasurement geophysical approach considered for this project, it is expected that the controlled-source electromagnetic (CSEM) method is a strong contributor to mapping the CO 2 movement. A feasibility study of the CSEM method, including 1D and 3D modeling and a field noise test, was conducted to determine its effectiveness in monitoring CO 2 in the Broom Creek and Deadwood Formations. The study results demonstrate that the CSEM method can be used for CO 2 storage monitoring in the study area.

20 FOSSIL-FUELED POWER PLANTS↗

Wiring design for the control of electromagnetic interference (EMI)

Wiring design is only one important aspect of EMI control. Other important areas for EMI are: circuit design, filtering, grounding, bonding, shielding, lighting, electrostatic discharge (ESD), transient suppression, and electromagnetic pulse (EMP). Topics covered include: wire magnetic field emissions at low frequencies; wire radiated magnetic field emissions at frequencies; wire design guidelines for EMI control; wire design guidelines for EMI control; high frequency emissions from cables; and pulse frequency spectra.

Kopasakis, George↗

Charged Wellbore Casing Controlled Source Electromagnetics (CWC-CSEM) for Reservoir Imaging and Monitoring (Final report)

This project addresses the needs of the U.S. Department of Energy (DOE) to develop advanced monitoring technologies and protocols to track the fate of subsurface carbon dioxide (CO2) plumes for carbon storage. Specifically, the project seeks to develop and test a unique and novel system of technologies consisting of electromagnetic data acquisition, coupled multiphysics imaging, and reservoir model enhancement to understand the migration and long-term distribution of CO2 in the subsurface. The overarching objective is to develop an integrated approach for long term monitoring of carbon storage. The two main components of the project include the methodology development and the test of the method at a field site. The methodology component consists of 1) developing the field procedure and protocol for collecting time-lapse controlled-source electromagnetic (CSEM) data with source electric current injected into the subsurface through wellbore casings; 2) building of background 3D electrical conductivity utilizing multiple sources of data such as supplemental surface transient EM (TEM) surveys, well-logs, and seismic structural information, for enhancing CSEM signal from reservoir depths; and 3) coupled multiphysics simulations and inversion of CSEM data constrained by production data and by structural information from seismic imaging of the reservoir and overlying formations. The testing component used the field site of Bell Creek Oil Field, which served both as a field laboratory for the method development as well as a test site to evaluate the CSEM signal strengths and the methodology developed in this research project. We have accomplished all the proposed tasks and developed the methodology as planned. These include the procedure for time-lapse CSEM data acquisition, data processing techniques, integration with 3D conductivity model building, fast reservoir simulation for history matching using machine learning, and interpreting CSEM data with coupling to the reservoir modeling. Collectively, the outcome of these tasks form a coherent workflow that can be applied to monitor dedicated carbon storage in saline reservoirs. The testing component evaluated the applicability and limitations of the method, and concluded that the method would be ideal for monitoring dedicated carbon storage sites utilizing saline reservoirs.

54 ENVIRONMENTAL SCIENCES↗

Mechanisms of electromagnetic field control on mineral scaling in brackish water reverse osmosis: Combined homogenous and heterogeneous nucleation

Electromagnetic field (EMF) treatment has emerged as a promising approach for scaling control due to its cost-effectiveness, simplicity, and low energy consumption. However, there is a limited understanding of the mechanisms by which applied EMF impacts mineral scaling in reverse osmosis (RO) systems. This has led to inconclusive and varied results and uncertainties regarding its effectiveness. This study elucidates the impacts of EMF on homogenous and heterogeneous nucleation and membrane performance during RO desalination of different feedwaters. Our results reveal that EMF exhibits greater efficacy in treating near-saturated water (SI∼0), especially when coupled with extended hydraulic flushing (HF). For saturated brackish water desalination, heterogeneous scaling predominantly occurs on membrane surfaces, with the effectiveness of EMF in inhibiting scaling primarily attributed to the hydration effect. In supersaturated solutions, EMF promotes bulk precipitation due to the magnetohydrodynamic effect, quickly blocking membrane pores. Thus, when the saturation reaches a certain high level during RO desalination, magnetohydrodynamic EMF effects can accelerate flux decline caused by homogeneous scaling. In conclusion, this work provides an efficient method for predicting EMF efficiency, emphasizing the importance of saturation conditions and HF cleaning duration in determining membrane performance, suggesting these show promise for improving undersaturated or near-saturated feedwater desalination via RO.

42 ENGINEERING↗

A CFD Study Assisted with Experimental Confirmation for Liquid Shape Control of Electromagnetically Levitated Bulk Materials

Two types of optimized electromagnetic levitators were designed to achieve the free surface shape control of metallic melts as the combined results of the Lorentz force, sample gravity, and surface tension. The levitation behavior of bulk melts was investigated using computational fluid dynamics (CFD) modeling coupled with high-frequency electromagnetic field analysis and the arbitrary Lagrangian–Eulerian (ALE) method. The difference in the oscillation behavior between the solid and molten samples was explained by the damping of the electromagnetic induction and liquid viscosity. The motion of the mass center, melt shape, flow pattern, and Lorentz force in the levitated melt were determined within a wide excitation current range. With the increase in the applied current, the melt’s centroid position rose sharply in the area with low current but displayed a slow increase in the area with high current. Meanwhile, the stable shape of the bulk melt showed the typical transition from a long taper through a short taper and then into a rhombus. The internal flow pattern transformed from a simple double-loop structure to a complex configuration with three or four loops. The dependence of the deformation on the Bond number was analyzed in the two types of levitators. In addition, the stable shape and swing process of the bulk Al melt within the two types of electromagnetic levitation (EML) systems were quantitatively studied under protective inert gas conditions. The melt contour could be well described by the 10th Legendre polynomial function with a deviation of less than 0.5 pct.

36 MATERIALS SCIENCE↗