Rotation of electrothermal-instability-driven overheating structure due to helically oriented surface magnetic field on a high-current-density aluminum rod
Experiments on the 1-MA, 100-ns-rise-time Mykonos Facility demonstrate rotation of electrothermal instability (ETI)-driven overheating structure on 1.00-mm-diameter, 10-nm-surface roughness, 99.999%-pure aluminum rods, which are pulsed with helically polarized surface magnetic field. Rods are machined to include pairs of 10-micron-scale quasi-hemispherical voids or “engineered defects (ED)” which provide the dominant current density perturbation from which ETI grows most rapidly. Experiments include an axial magnetic field component through the addition of a helically wound return-current electrode or “helical return can (HRC).” For a given HRC design, azimuthal field (B ɵ ) and axial field (B z ) components rise at a prescribed and fixed ratio, driving an increasing magnetic field of constant polarization at the rod's surface; most experiments generated surface magnetic field at a 15-degree field polarization angle (from horizontal) defined as ɸ B = arctan(B z /B ɵ ). ETI-driven emission patterns from individual ED are observed to rotate along ɸ B , while emission patterns from dielectric-coated ED pairs are shown to elongate and preferentially merge along ɸ B , in qualitative agreement with 3D-magnetohydrodynamic simulations. These data strongly support that for a randomized distribution of current density perturbations on a high-current density conductor, nearby perturbations will favorably merge about ɸ B , with the degree of merging increasing with current. Such observations offer fundamental new understanding of the seeding mechanisms of the helical magneto-Rayleigh Taylor (MRT) instabilities observed from axially magnetized magnetically driven imploding liners.