Synchrotron radiation-based far-infrared spectroscopic ellipsometer with full Mueller-matrix capability

We developed far-IR spectroscopic ellipsometer at the U4IR beamline of the National Synchrotron Light Source in Brookhaven National Laboratory. This ellipsometer is able to measure both, rotating analyzer and full-Mueller matrix spectra using rotating retarders, and wire-grid linear polarizers. We utilize exceptional brightness of synchrotron radiation in the broad spectral range between about 20 and 4000 cm{sup -1}. Fourier-transform infrared (FT-IR) spectrometer is used for multi-wavelength data acquisition. The sample stage has temperature variation between 4.2 and 450 K, wide range of {theta}-2{theta} angular rotation, {chi} tilt angle adjustment, and X-Y-Z translation. A LabVIEW-based software controls the motors, sample temperature, and FT-IR spectrometer and also allows to run fully automated experiments with pre-programmed measurement schedules. Data analysis is based on Berreman's 4 Multiplication-Sign 4 propagation matrix formalism to calculate the Mueller matrix parameters of anisotropic samples with magnetic permeability {mu}{ne} 1. A nonlinear regression of the rotating analyzer ellipsometry and/or Mueller matrix (MM) spectra, which are usually acquired at variable angles of incidence and sample crystallographic orientations, allows extraction of dielectric constant and magnetic permeability tensors for bulk and thin-film samples. Applications of this ellipsometer setup for multiferroic and ferrimagnetic materials with {mu}{ne} 1 are illustrated with experimental results and simulations for TbMnO{sub 3} and Dy{sub 3}Fe{sub 5}O{sub 12} single crystals. We demonstrate how magnetic and electric dipoles, such as magnons and phonons, can be distinguished from a single MM measurement without adducing any modeling arguments. The parameters of magnetoelectric components of electromagnon excitations are determined using MM spectra of TbMnO{sub 3}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A synchrotron-radiation-based variable angle ellipsometer for the visible to vacuum ultraviolet spectral range

A rotating analyzer spectroscopic polarimeter and ellipsometer with a wide-range θ-2θ goniometer installed at the Insertion Device Beamline of the Metrology Light Source in Berlin is presented. With a combination of transmission- and reflection-based polarizing elements and the inherent degree of polarization of the undulator radiation, this ellipsometer is able to cover photon energies from about 2 eV up to 40 eV. Additionally, a new compensator design based on a CaF{sub 2} Fresnel rhomb is presented. This compensator allows ellipsometric measurements with circular polarization in the vacuum ultraviolet spectral range and thus, for example, the characterization of depolarizing samples. The new instrument was initially used for the characterization of the polarization of the beamline. The technical capabilities of the ellipsometer are demonstrated by a cohesive wide-range measurement of the dielectric function of epitaxially grown ZnO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Paired circularly polarized heterodyne ellipsometer

We develop a paired circularly polarized heterodyne ellipsometer (PCPHE), in which a heterodyne interferometer based on a two-frequency circularly polarized laser beam is set up. It belongs to an amplitude-sensitive ellipsometer that is able to provide not only a wider dynamic range of polarization modulation frequency but also a higher detection sensitivity than that of a conventional photometric ellipsometer. A real-time and precise measurement of ellipsometric parameters, which demonstrated an accuracy of less than 1 nm on thickness measurement of SiO2 thin film deposited on silicon substrate, can be applied with the PCPHE.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopic ellipsometer based on direct measurement of polarization ellipticity

A polarizer-sample-Wollaston prism analyzer ellipsometer is described in which the ellipsometric angles {psi} and {Delta} are determined by direct measurement of the elliptically polarized light reflected from the sample. With the Wollaston prism initially set to transmit p- and s-polarized light, the azimuthal angle P of the polarizer is adjusted until the two beams have equal intensity. This condition yields {psi}={+-}P and ensures that the reflected elliptically polarized light has an azimuthal angle of {+-}45 deg. and maximum ellipticity. Rotating the Wollaston prism through 45 deg. and adjusting the analyzer azimuth until the two beams again have equal intensity yields the ellipticity that allows {Delta} to be determined via a simple linear relationship. The errors produced by nonideal components are analyzed. We show that the polarizer dominates these errors but that for most practical purposes, the error in {psi} is negligible and the error in {Delta} may be corrected exactly. A native oxide layer on a silicon substrate was measured at a single wavelength and multiple angles of incidence and spectroscopically at a single angle of incidence. The best fit film thicknesses obtained were in excellent agreement with those determined using a traditional null ellipsometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Gaertner L119 ellipsometer and its use in the measurement of thin films

An introduction to the study of ellipsometry is presented, with special attention given to the Gaertner model L119 ellipsometer and the techniques of measuring thin films with this instrument. Values obtained from the ellipsometer are analyzed by a computer program for a determination of optical constants and thickness of the film.

Linkous, M.↗

Linear Polarization Measurements with a New Soft X-Ray Polarimeter and Ellipsometer at a Bending Magnet Beamline of a Compact Storage Ring

Linear polarization measurements were carried out using a newly developed soft x-ray polarimeter and ellipsometer (SXPE) for complete polarization analysis at a soft x-ray beamline (BL-11) of the SR Center, Ritsumeikan University, Japan. A Mo/Si multilayer mirror (period: 10.36 nm, ratio of Mo layer to period: 0.64, and 23 bilayers with topmost Si layer) was deposited on the surface of a commercial Si(111) substrate by an ion beam sputtering method. It was cut into two pieces which were then used as reflection-type polarizers. When the incident wavelength was scanned from 12.4 nm to 14.8 nm by a Monk-Gillieson type varied-line-spacing grating monochromator of the BL-11, the angles of incidence of both the Mo/Si multilayer polarizers in the SXPE were also varied from 37.5 deg. to 52.3 deg. The polarizances depended strongly on the wavelength, and the best performance of over 99% was obtained in the vicinity of 14 nm. Using these polarizers, we assessed that the degree of linear polarization of the BL-11 was almost constant at 85-88% in the measured wavelength range.

43 PARTICLE ACCELERATORS↗

Development of a spectroscopic Mueller matrix imaging ellipsometer for nanostructure metrology

In this paper, we describe the development of a spectroscopic Mueller matrix imaging ellipsometer (MMIE), which combines the great power of Mueller matrix ellipsometry with the high spatial resolution of optical microscopy. A dual rotating-compensator configuration is adopted to collect the full 4 × 4 imaging Mueller matrix in a single measurement. The light wavelengths are scanned in the range of 400–700 nm by a monochromator. The instrument has measurement accuracy and precision better than 0.01 for all the Mueller matrix elements in both the whole image and the whole spectral range. The instrument was then applied for the measurement of nanostructures combined with an inverse diffraction problem solving technique. The experiment performed on a photoresist grating sample has demonstrated the great potential of MMIE for accurate grating reconstruction from spectral data collected by a single pixel of the camera and for efficient quantification of geometrical profile of the grating structure over a large area with pixel resolution. It is expected that MMIE will be a powerful tool for nanostructure metrology in future high-volume nanomanufacturing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interferometric ellipsometer

We describe an interferometric ellipsometer that, in contrast to previous designs, requires a single reflection from a sample surface so that tan{psi} and {delta} are measured directly. A reference beam is created in one arm of a modified Mach-Zehnder interferometer such that the p and s polarizations have a common phase and fixed relative amplitude, irrespective of the sample. This beam is combined interferometrically with the measurement beam. The output beam is spatially separated into its polarization components and temporal fringes created at the photodetectors via mechanical scanning of one of the mirrors. Measurements made on a reference SiO2 film are in excellent agreement with the calibration certificate while those made on a glass surface demonstrate measurement capabilities for low reflectivity samples. Estimates of the noise performance indicate a precision, in air, of {approx}41 pm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ellipsometer for measurement in ultrahigh vacuum

Ellipsometer, used with ultrahigh vacuum, allows measurement of varied angles of incidence. Vacuum chamber, directly incorporated into optical bench systems, allows varied angle measurements to be taken through same region of a window.

Walter, H. U.↗

Small-Modulation Ellipsometer

Small-modulation ellipsometer contains no moving parts and insensitive to small misalignments. Provides real-time, simultaneous measurements of both ellipsometric parameters, without need for separate calibration measurement or tedious adjustments. Can be made compact and rugged for operation in harsh environments.

Woollam, J.↗

Ellipsometer

In an ellipsometer, a phase-modulated, polarized light beam is applied to a sample, electrical signals are obtained representing the orthogonal planes of polarization of the light after it has interacted with the sample and the constants of the sample are calculated from the two resulting electrical signals. The phase modulation is sufficiently small so that the calibration errors are negligible. For this purpose, the phase modulator, phase modulates the light within a range of no more than ten degrees peak to peak. The two electrical signals are expanded by Fourier analysis and the coefficients thereof utilized to calculate psi and delta.

Ducharme, Stephen Paul↗

Development and performance test of a soft x-ray polarimeter and ellipsometer for complete polarization analysis

A new apparatus for polarimetric and ellipsometric measurements based on the rotating-analyzer method in the soft x-ray region has been designed, constructed, and installed in the soft x-ray beamline (BL-11) at the SR Center of Ritsumeikan University, Shiga, Japan. It can realize the optical configurations for the complete polarization analysis by using six independently movable drive shafts. A demonstration of the capabilities of the apparatus has been performed using Mo/Si multilayer polarizers deposited by an ion beam sputtering method. It is for the first time shown that the degree of linear polarization of monochromatized light from the BL-11 is approximately 87% at 92 eV since the beamline has been constructed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An ellipsometer with variable angle of incidence for studies in ultrahigh vacuum

The windows for the vacuum chamber are incorporated into the optical bench system by means of flexible bellows which allow measurements to be made over a large range of angle of incidence, one of which is chosen so that maximum sensitivity is obtained. The principal angle of incidence was determined, and straightforward corrections for strain birefringence of vacuum chamber windows were made. Atomically clean surfaces of sodium chloride and lithium fluoride were investigated to verify the performance of the system. Submonolayer and monolayer coverage of water on these surfaces could be detected. On cleavage planes of NaCl, a first monolayer of adsorbed water is complete at about one torr only.

Walter, H. U.↗

Ellipsometer measurements of epitaxial GaAs layers: A concept

Report discusses analysis involving Maxwell's equations formed in a 6-by-6 matrix. By applying boundary conditions at proper points in sample, equation for propagation of light through anisotropic medium is reduced to eigenvalue problem resulting in 4-by-4 matrix.

Desmet, D. J.↗

Study of Al with a combined Auger electron spectrometer-ellipsometer system

Auger electron spectroscopy and ellipsometry were applied in order to measure the optical constants and study the surface chemistry of vapor-deposited Al films and high-purity bulk Al surfaces in situ under vacuum. The optical constants measured were compared with the extinction coefficient computed by the free-electron theory. The contamination of the clean Al surface was in the form of a metal oxide film. Auger electron spectroscopic measurements were used to establish the relationship between the Auger peaks of O (513 eV) and aluminum oxide (53 eV) and changes in the measured optical phase and film thickness. The free path length of the Al Auger electrons (67 eV) in the oxide film was determined, and it was shown that the amplitude of these peaks is a linear function of film thickness down to 0.6 A.

Allen, T. H.↗

Instrumentation of the variable-angle magneto-optic ellipsometer and its application to M-O media and other non-magnetic films

A new and comprehensive dielectric tensor characterization instrument is presented for characterization of magneto-optical recording media and non-magnetic thin films. Random and systematic errors of the system are studied. A series of TbFe, TbFeCo, and Co/Pt samples with different composition and thicknesses are characterized for their optical and magneto-optical properties. The optical properties of several non-magnetic films are also measured.

Zhou, Andy F.↗

Invited Article: An integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument

We report on the development of the first integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument, covering an ultra wide spectral range from 3 cm{sup −1} to 7000 cm{sup −1} (0.1–210 THz or 0.4–870 meV). The instrument comprises four sub-systems, where the magneto-cryostat-transfer sub-system enables the usage of the magneto-cryostat sub-system with the mid-infrared ellipsometer sub-system, and the far-infrared/terahertz ellipsometer sub-system. Both ellipsometer sub-systems can be used as variable angle-of-incidence spectroscopic ellipsometers in reflection or transmission mode, and are equipped with multiple light sources and detectors. The ellipsometer sub-systems are operated in polarizer-sample-rotating-analyzer configuration granting access to the upper left 3 × 3 block of the normalized 4 × 4 Mueller matrix. The closed cycle magneto-cryostat sub-system provides sample temperatures between room temperature and 1.4 K and magnetic fields up to 8 T, enabling the detection of transverse and longitudinal magnetic field-induced birefringence. We discuss theoretical background and practical realization of the integrated mid-infrared, far-infrared, and terahertz optical Hall effect instrument, as well as acquisition of optical Hall effect data and the corresponding model analysis procedures. Exemplarily, epitaxial graphene grown on 6H-SiC, a tellurium doped bulk GaAs sample and an AlGaN/GaN high electron mobility transistor structure are investigated. The selected experimental datasets display the full spectral, magnetic field and temperature range of the instrument and demonstrate data analysis strategies. Effects from free charge carriers in two dimensional confinement and in a volume material, as well as quantum mechanical effects (inter-Landau-level transitions) are observed and discussed exemplarily.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ellipsometry

Ellipsometry is a technique often used to measure the thickness and properties of a thin film. This article covers the instrumental, theoretical, and practical aspects of this technique. Notably, different types of instruments including nulling ellipsometer, rotating compensator ellipsometer, and photoelastic modulator ellipsometer designs are presented. Elements of proper data analysis are also included, such as the use of an error-based figure of merit.

Complex reflection coefficients↗