Designing Crane Controls with Applied Mechanical and Electrical Safety Features

The use of overhead traveling bridge cranes in many varied applications is common practice. In particular, the use of cranes in the nuclear, military, commercial, aerospace, and other industries can involve safety critical situations. Considerations for Human Injury or Casualty, Loss of Assets, Endangering the Environment, or Economic Reduction must be addressed. Traditionally, in order to achieve additional safety in these applications, mechanical systems have been augmented with a variety of devices. These devices assure that a mechanical component failure shall reduce the risk of a catastrophic loss of the correct and/or safe load carrying capability. ASME NOG-1-1998, (Rules for Construction of Overhead and Gantry Cranes, Top Running Bridge, and Multiple Girder), provides design standards for cranes in safety critical areas. Over and above the minimum safety requirements of todays design standards, users struggle with obtaining a higher degree of reliability through more precise functional specifications while attempting to provide "smart" safety systems. Electrical control systems also may be equipped with protective devices similar to the mechanical design features. Demands for improvement of the cranes "control system" is often recognized, but difficult to quantify for this traditionally "mechanically" oriented market. Finite details for each operation must be examined and understood. As an example, load drift (or small motions) at close tolerances can be unacceptable (and considered critical). To meet these high functional demands encoders and other devices are independently added to control systems to provide motion and velocity feedback to the control drive. This paper will examine the implementation of Programmable Electronic Systems (PES). PES is a term this paper will use to describe any control system utilizing any programmable electronic device such as Programmable Logic Controllers (PLC), or an Adjustable Frequency Drive (AID) 'smart' programmable motion controller. Therefore the use of the term Programmable Electronic Systems (PES) is an encompassing description for a large spectrum of programmable electronic control devices.

Lytle, Bradford P.↗

Electrical Engineering Medium Voltage Protection and Coordination

This presentation covers the basics of the medium voltage electrical system on the Kennedy Space Center. The material will include the process of selective coordination between protective devices and the analysis of a fault that occurred in the electrical system. I will discuss the most common causes of faults found and how the system reacts to the faults at different locations in the subsystem. Explain the importance of the sensitivity and coordination between the devices to protect the equipment it is supplying.

Wessner, Jason R.↗

A new characterization of the icing environment below 10,000 feet AGL from 7,000 miles of measurements in supercooled clouds

A growing requirement over the past decade for a new assessment of aircraft icing conditions in wintertime clouds at altitudes up to about 10,000 feet is discussed. The requirement was documented in past workshops and comes primarily from the helicopter community which wants ice-protected rotorcraft to meet increasing demands for all-weather operations. Currently, only a few of the larger helicopters are equipped with certification of ice-protection devices. This is because the current FAA criteria for design and certification of ice-protection equipment results in power and payload penalties that smaller rotorcraft cannot tolerate. The FAA criteria were actually designed for large, transport-category aircraft capable of flying to 20,000 feet or more. For this reason, there have been concerns that the current criteria may be too severe for low-performance aircraft, such as helicopters, which generally operate at altitudes below 10,000 feet.

Jeck, R. K.↗

Command module/service module reaction control subsystem assessment

Detailed review of component failure histories, qualification adequacy, manufacturing flow, checkout requirements and flow, ground support equipment interfaces, subsystem interface verification, protective devices, and component design did not reveal major weaknesses in the command service module (CSM) reaction control system (RCS). No changes to the CSM RCS were recommended. The assessment reaffirmed the adequacy of the CSM RCS for future Apollo missions.

Weary, D. P.↗

Viscoelastic foam cushion

Foam is viscous and elastic with unusual and useful temperature, humidity, and compression responses. Applied weight and pressure distributed equally along entire interface with foam eliminates any pressure points. Flexible urethane foam is ideal for orthopedic and prosthetic devices, sports equipment, furniture, and crash protection.

Kubokawa, C. C.↗

Lightning accommodation systems for wind turbine generator safety

The wind turbine safety program identifies the naturally occurring lightning phenomenon as a hazard with the potential to cause loss of program objectives, injure personnel, damage system instrumentation, structure or support equipment and facilities. Several candidate methods of lightning accommodation for each blade were designed, analyzed, and tested by submitting sample blade sections to simulated lightning. Lightning accommodation systems for composite blades were individually developed. Their effectiveness was evaluated by submitting the systems to simulated lightning strikes. The test data were analyzed and system designs were reviewed on the basis of the analysis. This activity is directed at defining design and procedural constraints, requirements for safety devices and warning methods, special procedures, protective equipment and personnel training.

Bankaitis, H.↗

Foundation, excavation and radiation shielding concepts for a 16-m large lunar telescope

NASA is considering a 16-m diameter optical telescope on the moon as a part of the Space Exploration Initiative. Fundamental concepts of engineering activities on the moon and how they can be applied to the establishment of a 16-m large lunar telescope (LLT) are discussed. These fundamental concepts include the engineering response of lunar soils and how they affect construction activities, namely, drilling, blasting, ripping, digging and compaction. A mirror support structure and foundation design concept is proposed. The foundation considered is a multiple contact points spud-can type footing. It does not appear that a deep foundation or the presence of bedrock is required to achieve the telescope foundation stiffness. The LLT system will include a regolith covered housing, the size of a small room, which will contain sensitive electronic equipment including charge coupled devices which need protection from cosmic radiation effects. A brief discussion is made on radiation, radiation transport and radiation effects on electronics and on humans. Radiation protection techniques and the different emplacement schemes for the LLT instrument housing for radiation protection are suggested. A structural concept of an early lunar based telescope is also presented.

Chua, Koon M.↗

Evaluating the Viability of Compact and Portable X-Ray Systems for an Exploration Medical System in a Ground Demonstration

MOTIVATION FOR INCLUDING X-RAY CAPABILITIES For upcoming exploration missions, the need for enhanced medical care becomes critical due to extended mission durations, significant communication delays, and minimal evacuation opportunities. Previous evidence by our team has revealed that among the 119 medical conditions targeted for management during spaceflight within NASA Exploration Medical Capability’s IMPACT Condition List, at least 36 could benefit from radiography (XR). Utilizing XR for diagnosis and management is hypothesized to significantly improve management of crew health by enabling the immediate evaluation and confirmation of potential injuries or illnesses. Beyond clinical applications, XR also holds potential for non-destructive testing (NDT). This includes applications such as assessing the structural integrity of the spacecraft, analyzing surface and meteorite samples, and inspecting onboard electronics. THREE CANDIDATE X-RAY SYSTEMS CHOSEN FOR GROUND DEMONSTRATION The Exploration Medical Capability Element (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) of the Mars Campaign Office initiated early background work for ground demonstrations. In FY21, ExMC published a Concept of Operations to guide requirements development. By FY23, XMIPT and yet2, a technology scouting and open innovation consulting firm, had completed a market survey and trade study to identify potential miniature XR systems. Selection criteria included commercial-off-the-shelf availability, low mass and volume, and regulatory compliance. The top three candidate devices—Remedi REMEX-KA6, MinXray Impact, and FujiFilm Xair—were acquired to characterize the requirements and capabilities of each device. To facilitate testing, phantoms, and radiographic personal protective equipment (PPE) were purchased, and a dedicated space was designated for XRS usage at Glenn Research Center. During this presentation, the mass, volume, and power requirements for each of the three piloted devices are revealed, as well as information regarding the detector, mA, and kV of the devices. GOAL AND OBJECTIVES OF A MINI XRS GROUND DEMONSTRATION The primary goal of ExMC/XMIPT technology demonstrations is to bridge the gap in available, flight-ready medical device technology by flight-testing diagnostic and treatment technologies essential for managing medical conditions during exploration missions. These technologies must adhere to vehicle constraints such as mass, volume, power, and data requirements, integrate seamlessly with medical decision-support tools, and support increasingly Earth-independent operations. There are three main objectives for the future ground demonstration of these three devices. First, we aim to determine the full capabilities of these three miniature XR systems within the context of the spaceflight environment. While medical applications are the primary focus for the miniature XR, a comprehensive exploration of non-medical uses has been initiated by an XMIPT-sponsored NASA SPARK campaign to identify collaborators. Second, we plan to establish criteria and to use insights gained from evaluating each miniature XR against those criteria to select the most suitable system among the three candidates. Third, we intend to evaluate their suitability for flight certification, which includes assessing its durability for launch, reentry, and exposure to high background radiation, as well as its compatibility with existing data architecture systems. Numerous subject matter experts from NASA and partner institutions will support these objectives.

C A Haddix↗

Beam Stop For High-Power Lasers

Graphite/aluminum plate absorbs most of light. Beam stop fits on standard optical mounting fixture. Graphite plate thick enough to absorb incident laser beam but thin enough to transfer heat quickly to heat sink. Device used for variety of blocking purposes. For example, blocks laser beam after it passes through experimental setup, or at each stage of setup so stages checked and tested in sequence. Negligible reflectance of device is valuable safety feature, protecting both users and equipment from reflections.

Mcdermid, Iain S.↗

DC wiring system grounding and ground fault protection issues for central station photovoltaic power plants

The DC wiring system for a photovoltaic power plant presents a number of unique challenges to be overcome by the plant designers. There are a number of different configurations that the grounding of the DC wiring system can take, and the choice will affect the number and type of protective devices required to ensure safety of personnel and protection of equipment. The major grounding and fault protection considerations that must be taken into account when selecting the basic overall circuit configuration are summarized. The inherent advantages and disadvantages of each type of circuit grounding (resistance or solid) along with the personnel safety and equipment protection issues for each of these grounding methods are presented.

Simburger, E. J.↗

OSHA medical and workplace surveillance requirements and NIOSH recommendations (for employees exposed to toxic substances and other work hazards)

Both OSHA medical and work place surveillance requirements and NIOSH recommendations were prepared as a desk reference to help occupational health professionals to perform their duties. The medical surveillance information focuses on frequency of physical examinations, specific problems that may arise as a result of exposure (e.g., decreased immunocompetence, weight loss, ets.), conditions that intensify the harmful effects of exposure (e.g., medication an exposed employee may be taking, cigarette smoking, etc.), the areas that should be scrutinized in medical and work histories and during the physical exam, and specific clinical tests that should be conducted. Recordkeeping requirements are also specified. The workplace surveillance information consists of monitoring requirements, personal protective equipment requirements, and recordkeeping requirements. Such details as the sampling devices that should be used, the type of respirators that should be worn, and the frequency of inspections are included. This document does not specify the training, labeling and posting, and safe work practice requirements and recommendations due to space considerations.

Cooper, L. P.↗

Final Report on the Detection of Green Monopropellants

In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

Detection↗

A study of an advanced confined linear energy source

A literature survey and a test program to develop and evaluate an advanced confined linear energy source were conducted. The advanced confined linear energy source is an explosive or pyrotechnic X-Cord (mild detonating fuse) supported inside a confining tube capable of being hermetically sealed and retaining all products of combustion. The energy released by initiation of the X-Cord is transmitted through the support material to the walls of the confining tube causing an appreciable change in cross sectional configuration and expansion of the tube. When located in an assembly that can accept and use the energy of the tube expansion, useful work is accomplished through fracture of a structure, movement of a load, reposition of a pin, release of a restraint, or similar action. The tube assembly imparts that energy without release of debris or gases from the device itself. This facet of the function is important to the protection of men or equipment located in close proximity to the system during the time of function.

Anderson, M. C.↗

The ac power line protection for an IEEE 587 Class B environment

The 587B series of protectors are unique, low clamping voltage transient suppressors to protect ac-powered equipment from the 6000V peak open-circuit voltage and 3000A short circuit current as defined in IEEE standard 587 for Category B transients. The devices, which incorporate multiple-stage solid-state protector components, were specifically designed to operate under multiple exposures to maximum threat levels in this severe environment. The output voltage peaks are limited to 350V under maximum threat conditions for a 120V ac power line, thus providing adequate protection to vulnerable electronic equipment. The principle of operation and test performance data is discussed.

Roehr, W. D.↗

Risk Presentation Using the Three Dimensions of Likelihood, Severity, and Level of Control

Traditional hazard analysis techniques utilize a two-dimensional representation of the results determined by relative likelihood and severity of the residual risk. These matrices present a quick-look at the Likelihood (Y-axis) and Severity (X-axis) of the probable outcome of a hazardous event. A three-dimensional method, described herein, utilizes the traditional X and Y axes, while adding a new, third dimension, shown as the Z-axis, and referred to as the Level of Control. The elements of the Z-axis are modifications of the Hazard Elimination and Control steps (also known as the Hazard Reduction Precedence Sequence). These steps are: 1. Eliminate risk through design. 2. Substitute less risky materials for more hazardous materials. 3. Install safety devices. 4. Install caution and warning devices. 5. Develop administrative controls (to include special procedures and training.) 6. Provide protective clothing and equipment. When added to the two-dimensional models, the level of control adds a visual representation of the risk associated with the hazardous condition, creating a tall-pole for the leastwell-controlled failure while establishing the relative likelihood and severity of all causes and effects for an identified hazard. Computer modeling of the analytical results, using spreadsheets and three-dimensional charting gives a visual confirmation of the relationship between causes and their controls.

Watson, Clifford↗

Risk Assessment Using the Three Dimensions of Probability (Likelihood), Severity, and Level of Control

Traditional hazard analysis techniques utilize a two-dimensional representation of the results determined by relative likelihood and severity of the residual risk. These matrices present a quick-look at the Likelihood (Y-axis) and Severity (X-axis) of the probable outcome of a hazardous event. A three-dimensional method, described herein, utilizes the traditional X and Y axes, while adding a new, third dimension, shown as the Z-axis, and referred to as the Level of Control. The elements of the Z-axis are modifications of the Hazard Elimination and Control steps (also known as the Hazard Reduction Precedence Sequence). These steps are: 1. Eliminate risk through design. 2. Substitute less risky materials for more hazardous materials. 3. Install safety devices. 4. Install caution and warning devices. 5. Develop administrative controls (to include special procedures and training.) 6. Provide protective clothing and equipment. When added to the twodimensional models, the level of control adds a visual representation of the risk associated with the hazardous condition, creating a tall-pole for the least-well-controlled failure while establishing the relative likelihood and severity of all causes and effects for an identified hazard. Computer modeling of the analytical results, using spreadsheets and threedimensional charting gives a visual confirmation of the relationship between causes and their controls

Watson, Clifford↗

Risk Assessment Using the Three Dimensions of Probability (Likelihood), Severity, and Level of Control

Traditional hazard analysis techniques utilize a two-dimensional representation of the results determined by relative likelihood and severity of the residual risk. These matrices present a quick-look at the Likelihood (Y-axis) and Severity (X-axis) of the probable outcome of a hazardous event. A three-dimensional method, described herein, utilizes the traditional X and Y axes, while adding a new, third dimension, shown as the Z-axis, and referred to as the Level of Control. The elements of the Z-axis are modifications of the Hazard Elimination and Control steps (also known as the Hazard Reduction Precedence Sequence). These steps are: 1. Eliminate risk through design. 2. Substitute less risky materials for more hazardous materials. 3. Install safety devices. 4. Install caution and warning devices. 5. Develop administrative controls (to include special procedures and training.) 6. Provide protective clothing and equipment. When added to the two-dimensional models, the level of control adds a visual representation of the risk associated with the hazardous condition, creating a tall-pole for the least-well-controlled failure while establishing the relative likelihood and severity of all causes and effects for an identified hazard. Computer modeling of the analytical results, using spreadsheets and three-dimensional charting gives a visual confirmation of the relationship between causes and their controls.

Watson, Clifford C.↗

Shield For Flexible Pipe

Cylindrical shield designed to fit around flexible pipe to protect nearby workers from injury and equipment from damage if pipe ruptures. Designed as pressure-relief device. Absorbs impact of debris ejected radially from broken flexible pipe. Also redirects flow of pressurized fluid escaping from broken pipe onto flow path allowing for relief of pressure while minimizing potential for harm.

Ponton, Michael K.↗