Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electric power failures.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optimizing the location and configuration of disaster resilience hubs under transportation and electric power network failures

Natural disasters often result in failures of transportation network components and blackouts that imperil the wellbeing of vulnerable populations. In response to these events, resilience hubs have been proposed as a pre-disaster planning strategy to improve access to critical services. This paper introduces an optimization-based approach to locate and configure electric power-generating resilience hubs considering the possibility of failures in transportation and electric power systems. The model's objective is to identify hub locations and configurations that maximize transportation accessibility to the hubs and maximize the satisfaction of basic energy needs through hub-generated electric power. Besides a budget constraint, the model accounts for limits on the levels of hub energy generation vis-à-vis community energy demands, and on the transportation network distance of communities to hubs. Three heuristics are presented for the proposed planning problem. The first heuristic is a genetic algorithm (GA) with problem-specific solution generation procedures. The other two heuristics implement greedy search techniques. Numerical experiments were conducted, using data from rural Puerto Rico, to illustrate the application of the proposed model and heuristics, and examine their performance. In the numerical experiments, the GA heuristic found better solutions than the greedy heuristics. Additionally, design solutions consisting of spatially dispersed hubs with low energy generation capacity were better than solutions with spatially concentrated high-capacity hubs. Lastly, across a wide range of hub demand scenarios, only a small number of candidate hub locations consistently ranked among the best locations for establishing a hub.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power electronics reliability analysis.

This report provides the DOE and industry with a general process for analyzing power electronics reliability. The analysis can help with understanding the main causes of failures, downtime, and cost and how to reduce them. One approach is to collect field maintenance data and use it directly to calculate reliability metrics related to each cause. Another approach is to model the functional structure of the equipment using a fault tree to derive system reliability from component reliability. Analysis of a fictitious device demonstrates the latter process. Optimization can use the resulting baseline model to decide how to improve reliability and/or lower costs. It is recommended that both electric utilities and equipment manufacturers make provisions to collect and share data in order to lay the groundwork for improving reliability into the future. Reliability analysis helps guide reliability improvements in hardware and software technology including condition monitoring and prognostics and health management.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of Automated Power Systems Management for planetary spacecraft

Automated Power Systems Management is a technology being developed at JPL to provide the capability for onboard monitoring, computation, and control of planetary-spacecraft electrical power systems without the need for ground intervention. The technology uses microcomputers to provide the control and flexibility necessary to achieve rapid and decisive control of power system functions in the event of electrical power failures or unplanned events requiring power system responses. The current program at JPL includes the design, fabrication, test, and evaluation of a breadboard spacecraft power system, modified to incorporate automated power system functions which are implemented by means of a distributed microcomputer system.

Bridgeforth, A. O.↗

Surface radiation observations for October 27-28, 1986 during the Wisconsin FIRE/SRB experiment

A portion of both the shortwave and longwave surface radiation data is presented which was measured during the combined FIRE (First ISCCP Regional Experiment) and SRB (Surface Radiation Budget) experiments conducted in central Wisconsin from October 14 to November 2, 1988. The time periods from which high quality measurement values were obtained are summarized. Data gaps exist because of either equipment malfunctions or electrical power failures. Intercomparison of pre-experiment measurements by the various organizations involved suggests that all stations are accurate (relative to each other) to within about 10 W/m(sup -2) on a 24-hour daily average basis. Most of the instruments were calibrated by the National Radiation Centers in either the U.S. (National Oceanic and Atmospheric Administration) or Canada (Atmospheric Environment Service). October 27 and 28, 1986 were selected for detailed case study because a large amount of cirrus clouds existed over the experiment region on those days. Downwelled irradiance values are shown at each surface station at the time of afternoon NOAA-9 overpasses. Values shown are 10-minute averages centered about each overpass time, but minute-average data are available.

Whitlock, C. H.↗

Electrical power requirements analysis. Single failure tolerant entry

The results of an analysis of the orbiter electrical power system for the case of a single failure tolerant (SFT) entry are presented. The analysis was performed using the shuttle electrical power system analysis computer program. It was performed to permit assessment of the capability of the orbiter systems to support the proposed entry configuration and to provide the data necessary to identify potential constraints and limitations. Three contingency modes have been identified which would require an SFT entry. This analysis addresses an SFT entry resulting from the loss of two fuel cell powerplants, while on orbit. The results of the analysis indicate that, even under near optimum conditions, the fuel cell power demand will exceed the tested operating capacity of 16 kw, and that various electrical components may experience voltages below 24 VDC.

Pipher, M. D.↗

Fault Detection and Diagnosis in Spacecraft Electrical Power Systems

The ability to accurately identify and isolate failures in the electrical power system (EPS) is critical to ensure the reliability of spacecraft. This paper proposes a novel solution to the problem of fault detection and diagnosis in direct current (DC) electric power systems for spacecraft. Autonomous operation becomes essential during deep space missions that lack the ability to monitor and control the spacecraft from ground locations. The current state of EPS fault supervision is insufficient to guarantee highly reliable operation. To solve this issue, a combination of model-based and knowledge-based techniques are used in a hierarchical framework to improve the diagnostic performance of the system. Noise, disturbances, and modeling errors are considered in the design of the fault detection system. Practical considerations related to spacecraft flight hardware and software are accounted for in the system design for flight applications. To assess the functionality of the design, a wide array of failures are simulated in a series of experiments. The experiments showed that the technique improved the capability of the autonomous system by increasing the number of fault types diagnosed. The significance of this study is to provide a framework capable of advanced diagnostics of an EPS with little to no interaction from human operators.

Autonomous Power Systems↗

Reconfiguring Power Systems to Minimize Cascading Failures: Models and Algorithms

The main goal of this project was to develop new scientific tools, based on optimization techniques, with the purpose of controlling and modeling cascading failures of electrical power transmission systems. We have developed a high-quality tool for simulating cascading failures. The problem of how to control a cascade was addressed, with the aim of stopping the cascade with a minimum of load lost. Yet another aspect of cascade is the investigation of which events would trigger a cascade, or more appropriately the computation of the most harmful initiating event given some constraint on the severity of the event. One common feature of the cascade models described (indeed, of several of the cascade models found in the literature) is that we study thermally-induced line tripping. We have produced a study that accounts for exogenous randomness (e.g. wind and ambient temperature) that could affect the thermal behavior of a line, with a focus on controlling the power flow of the line while maintaining safe probability of line overload. This was done by means of a rigorous analysis of a stochastic version of the heat equation. We incorporated a model of randomness in the behavior of wind power output; again modeling an OPF-like problem that uses chance-constraints to maintain low probability of line overloads; this work has been continued so as to account for generator dynamics as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Abruptness of Cascade Failures in Power Grids

Electric power-systems are one of the most important critical infrastructures. In recent years, they have been exposed to extreme stress due to the increasing demand, the introduction of distributed renewable energy sources, and the development of extensive interconnections. We investigate the phenomenon of abrupt breakdown of an electric power-system under two scenarios: load growth (mimicking the ever-increasing customer demand) and power fluctuations (mimicking the effects of renewable sources). Our results on real, realistic and synthetic networks indicate that increasing the system size causes breakdowns to become more abrupt; in fact, mapping the system to a solvable statistical-physics model indicates the occurrence of a first order transition in the large size limit. Such an enhancement for the systemic risk failures (black-outs) with increasing network size is an effect that should be considered in the current projects aiming to integrate national power-grids into ‘‘super-grids’’.

42 ENGINEERING↗

Development of a Supervisory Tool for Fault Detection and Diagnosis of DC Electric Power Systems with the Application of Deep Space Vehicles

This dissertation formulates the problem of fault detection and diagnosis of DC electric power systems for the application of autonomous spacecraft. The ability to accurately identify and isolate failures in the electrical power system is critical to ensure the reliability of a spacecraft. This problem becomes more pronounced during deep space missions that lack the ability to monitor from ground control. The current state of electrical power system fault supervision is insufficient to guarantee highly reliable and robust operation. To solve this issue, a combination of model-based and rules-based techniques are used in a hierarchical framework to improve the diagnostic performance of the spacecraft electrical power system. Noise, disturbances, and modeling errors are considered in the design of the method. Practical considerations related to the hardware and software are discussed for the flight application. A wide array of failure types are simulated in a series of experiments to assess the functionality of the design. The experiments showed that the methods used improved the diagnostic capability of the autonomous system while taking into account the limitations attributed to flight software requirements. The significance of this study is to provide a framework capable of advanced diagnostics of an electrical power system with little to no interaction from a human operator.

Fault Detection and Diagnosis↗

Electromechanical Turboprop-Pitch-Control Mechanism

Propeller-control system autonomous and tolerant of failure. Mounting electrical-power module and conditioning/control systems inboard rotating propeller hub eliminates failure-prone slipring devices and creates autonomous, failure-tolerant propeller-control system. Modular component design facilitates on-the-wing maintenance. System highly adaptive to various sizes and gearbox configurations. Features and capabilities described unmatched by any comparable PCM now in existence. These capabilities needed by large, fuel-efficient, commuter turboprop aircraft now being developed by aircraft industry.

Steinetz, B. M.↗

ARRA: Reconfiguring Power Systems to Minimize Cascading Failures - Models and Algorithms

Building on models of electrical power systems, and on powerful mathematical techniques including optimization, model predictive control, and simluation, this project investigated important issues related to the stable operation of power grids. A topic of particular focus was cascading failures of the power grid: simulation, quantification, mitigation, and control. We also analyzed the vulnerability of networks to component failures, and the design of networks that are responsive to and robust to such failures. Numerous other related topics were investigated, including energy hubs and cascading stall of induction machines

24 POWER TRANSMISSION AND DISTRIBUTION↗

Failure Behavior and Control-Based Mitigation for a Parallel Hybrid Propulsion System

NASA is pursuing research to advance Electrified Aircraft Propulsion (EAP) technologies that address fuel burn and emission reduction goals. EAP brings the potential for improved performance over the state of the art. However, for these systems to be practical and certifiable, they need to possess adequate robustness to adverse conditions including a variety of system failures that are not applicable to conventional turbofans today. Numerous EAP concepts interface gas turbine engines with an electrical power system that includes electric machines and sometimes electrical energy storage. The expansion of the powertrain increases the probability of encountering a failure and introduces new failure modes. Failures within the electrical power system may also impact the gas turbine engine(s) to which the electrical powertrain is coupled. This effort investigates failures originating in the electrical power system and their impact on the parallel hybrid propulsion system. Reversionary control strategies are also demonstrated to reduce the impact of the failures. Failure mitigation strategies were devised and employed in simulation. Various failure scenarios were simulated including those occurring during steady state operation, transients, and takeoff and landing scenarios. The timing of the failure and delay in failure identification and activation of mitigation strategies are noteworthy variables in the study. While the system remained stable throughout all failure scenarios, delays in failure identification could result in undesirable conditions such as increased operating temperatures and reduced stall margin. The results demonstrate successful mitigation of failures through reversionary control modes and help to generate confidence in the robustness of the conceptual parallel hybrid propulsion system.

Failure behavior↗

Failure Behavior and Control Based Mitigation for a Parallel Hybrid Propulsion System

NASA is pursuing research to advance Electrified Aircraft Propulsion (EAP) technologies that address fuel burn and emission reduction goals. EAP brings the potential for improved performance over the state of the art. However, for these systems to be practical and certifiable, they need to possess adequate robustness to adverse conditions including a variety of system failures that are not applicable to conventional turbofans today. Numerous EAP concepts interface gas turbine engines with an electrical power system that includes electric machines and sometimes electrical energy storage. The expansion of the powertrain increases the probability of encountering a failure and introduces new failure modes. Failures within the electrical power system may also impact the gas turbine engine(s) to which the electrical powertrain is coupled. This effort investigates failures originating in the electrical power system and their impact on the parallel hybrid propulsion system. Reversionary control strategies are also demonstrated to reduce the impact of the failures. Failure mitigation strategies were devised and employed in simulation. Various failure scenarios were simulated including those occurring during steady state operation, transients, and takeoff and landing scenarios. The timing of the failure and delay in failure identification and activation of mitigation strategies are noteworthy variables in the study. While the system remained stable throughout all failure scenarios, delays in failure identification could result in undesirable conditions such as increased operating temperatures and reduced stall margin. The results demonstrate successful mitigation of failures through reversionary control modes and help to generate confidence in the robustness of the conceptual parallel hybrid propulsion system.

Failure behavior↗

Reliable LED Lighting Technologies: Key Factors and Procurement Guidance

Abstract— Lighting systems have the ability to transform the economic and educational infrastructure of disadvantaged communities, and eradicating “light poverty” has become one of the primary goals of the International Year of Light 2015. Solid-state lighting (SSL) technology, based on light-emitting diode (LED) light sources, has emerged as the next generation of lighting technology, with a current global market penetration of roughly 5%. This paper will report on recent research on understanding SSL lighting system reliability (failure modes, environmental stressors, electrical power quality); discuss the implications of SSL technology reliability for providing lighting services; and suggest practical approaches to ensure SSL reliability to benefit humanity. Among the key findings from this work is that LED sources can be extremely reliable, withstanding a broad range of environmental stresses without failure. Nonetheless, SSL lighting systems can have a negative impact on electrical power reliability, as well as on the affordability of lighting services, without attention to the quality of the accompanying power infrastructure. It is therefore critical to ensure that the performance of the power supply electronics used in lighting systems is matched to the quality of the power source, when evaluating energy efficient lighting choices.

Davis, Lynn↗