Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical Port”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeled Electricity Demand Profiles for Electric Port Cargo Handling Equipment in the United States

Electric port cargo handling equipment (eCHE) hourly load datasets for the top 25 U.S. cargo airports (by tonnage), as described in Polemis et al. (2025). Please cite as: Polemis, Katerina, Andrew Kotz, Kara Podkaminer, and Brennan Borlaug. 2025. Hourly Load Profile Dataset for Electric Port Cargo Handling Equipment in the United States. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-92141. https://www.nlr.gov/docs/fy25osti/92141.pdf

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hourly Load Profile Dataset for Electric Port Cargo Handling Equipment in the United States

Historically, ports have relied on fossil fuels, particularly diesel, as their primary energy source. Transitioning to electric cargo handling equipment (eCHE) offers a promising solution, as this relatively mature technology eliminates tailpipe emissions, reduces harmful airborne particulates, lowers noise pollution, and supports decarbonization. This study develops an initial estimation of hourly electricity demand for eCHE at the top 25 container ports (by tonnage) in the United States. These datasets, accessible at data.nrel.gov/submissions/281, provide valuable insights into the electricity demand patterns and potential grid impacts associated with widespread eCHE adoption, forming a foundation for future refinement based on stakeholder feedback.

33 ADVANCED PROPULSION SYSTEMS↗

DOE Zero Energy Ready Home Case Study HIA 2020: United Way of Long Island, Net Positive All Electric Home, Port Jefferson Station, NY

Case study of a DOE 2020 Housing Innovation Award winning custom home in a mixed-humid climate that got a HERS -2 with PV, with 2,500 square feet, featuring a novel attic truss specifically designed to accommodate a ducted mini-split heat pump tucked into an insulated chase in the vented attic. The walls are constructed of 2x6 studs installed at 24 inches on center and incorporating advanced framing techniques to reduce the amount of lumber needed and to provide more room for insulation.

Building America, residential construction, home b↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

My vehicle is a data mine

In this talk we explore how analysis of vehicle data provides information of individual vehicle behaviors, information of other vehicles in the flow of traffic, and insights into the behavior of drivers. Over the last two decades traditional passenger vehicles have been transformed from integrated two-port electrical nodes to cyber-physical systems of communicating computational nodes whose individual state and control variables are shared on a standard controller area network (CAN) bus. As driver assistance systems have crept into vehicles as safety features, driver behaviors can be observed through analysis of the data streams on the CAN bus as these new nodes communicate with one another. The properties of these data streams, as well as architectures and approaches to gather the data, are important to consider when drawing conclusions on the relevance of the data in making decisions at varying levels of the information hierarchy. We will demonstrate several technical challenges associated with these data collection processes, as well as preliminary results that demonstrate application relevance of the data to behavior, traffic, and systems domains.

42 ENGINEERING↗

Device having hybrid hydraulic-electric architecture

A device having a hybrid hydraulic-electric architecture includes a hydraulic pump/motor having first and second ports, and an electric motor. The device is configured to connect to two or more pressure rails, each pressure rail containing hydraulic fluid at a different pressure than the other pressure rails. A flow of hydraulic fluid from one of the pressure rails is driven through the hydraulic pump/motor, and a pressure difference exists between the first and second ports. The electric motor is configured to control a flow rate of the flow of hydraulic fluid and/or the pressure difference.

Li, Perry Yan-Ho↗

GIS Supported Optimal Site Selection for Coastal Structure Integrated Wave Energy Converters: Preprint

There is an urgent need for adaptative engineering towards more resilient coastal communities, and Coastal Structure Integrated Wave Energy Converters (CSI-WECs) are a promising solution. CSI-WECs are wave energy converters (WECs) that are built into coastal protection structures, such as breakwaters. These devices provide the dual benefits of coastal protection and local energy production, and unlike other WECs, maximizing energy production is not always the main objective. CSI-WECs are located near the shore, where the wave resource is lower, thus site selection for these devices differs from the typical offshore WECs. Other attributes of a site that may be more important than wave power include existing coastal structures, port proximity, electric transmission line proximity, and location of disadvantaged communities. Geospatial information systems (GIS) interfaces can be used to easily visualize geospatial data that represents these difference kinds of criteria important for the determination of optimal marine energy sites. Multi-Criteria Decision Analysis (MCDA) is a geospatial analysis method that allows for the evaluation of multiple, usually overlapping, criteria. This project applies GIS-based MCDA methods to two distinct case studies in Puerto Rico and California for CSI-WEC site selection. The two study sites contrast in terms of wave resource, coastal hazards, and local energy needs. This research demonstrates the utility of applying an MCDA framework within GIS to facilitate efficient site selection for devices with unique characteristics in different use cases.

coastal protection↗

Electric vehicle equipment for grid-integrated vehicles

Methods, systems, and apparatus for interfacing an electric vehicle with an electric power grid are disclosed. An exemplary apparatus may include a station communication port for interfacing with electric vehicle station equipment (EVSE), a vehicle communication port for interfacing with a vehicle management system (VMS), and a processor coupled to the station communication port and the vehicle communication port to establish communication with the EVSE via the station communication port, receive EVSE attributes from the EVSE, and issue commands to the VMS to manage power flow between the electric vehicle and the EVSE based on the EVSE attributes. An electric vehicle may interface with the grid by establishing communication with the EVSE, receiving the EVSE attributes, and managing power flow between the EVE and the grid based on the EVSE attributes.

33 ADVANCED PROPULSION SYSTEMS↗

Electric vehicle station equipment for grid-integrated vehicles

Methods, systems, and apparatus transferring power between the grid and an electric vehicle are disclosed. The apparatus may include at least one vehicle communication port for interfacing with electric vehicle equipment (EVE) and a processor coupled to the at least one vehicle communication port to establish communication with the EVE, receive EVE attributes from the EVE, and transmit electric vehicle station equipment (EVSE) attributes to the EVE. Power may be transferred between the grid and the electric vehicle by maintaining EVSE attributes, establishing communication with the EVE, and transmitting the EVSE maintained attributes to the EVE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated rectifier-generator system for AC-to-DC conversion

This disclosure relates AC-to-DC rectification and power flow control of electrical power generators. An integrated rectifier-generator AC-DC conversion circuit and system are disclosed for providing a regulated DC output. The integrated rectifier-generator AC-DC conversion circuit and system may include serially stacked passive and active rectifiers connected to multiple AC ports of an electrical power generator driven by mechanical energy captured by an energy harvester. The integrated rectifier-generator AC-DC conversion circuit and system may be configured to perform active ripple control and a maximum power tracking from the energy harvester by controlling a fraction of an overall power that flow through the active rectifier.

Huynh, Phuc Thanh↗

Potential use of battery packs from NCAP tested vehicles.

Several large electric vehicle batteries available to the National Highway Traffic Safety Administration are candidates for use in future safety testing programs. The batteries, from vehicles subjected to NCAP crashworthiness testing, are considered potentially damaged due to the nature of testing their associated vehicles have been subjected to. Criteria for safe shipping to Sandia is discussed, as well as condition the batteries must be in to perform testing work. Also discussed are potential tests that could be performed under a variety of conditions. The ultimate value of potential testing performed on these cells will rest on the level of access available to the battery pack, i.e. external access only, access to the on board monitoring system/CAN port or internal electrical access to the battery. Greater access to the battery than external visual and temperature monitoring would likely require input from the battery manufacturer.

Lamb, Joshua↗

Summary of Preliminary Concepts for a Port of Alaska Resilient Microgrid

The Port of Alaska in Anchorage enables the economic vitality of the Municipality of Anchorage and State of Alaska. It also provides significant support to defense activities across Alaska, especially to the Joint Base Elmendorf-Richardson (JBER) that is immediately adjacent to the Port. For this reason, stakeholders are interested in the resilience of the Ports operations. This report documents a preliminary feasibility analysis for developing an energy system that increases electric supply resilience for the Port and for a specific location inside JBER. The project concept emerged from prior work led by the Municipality of Anchorage and consultation with Port stakeholders. The project consists of a microgrid with PV, storage and diesel generation, capable of supplying electricity to loads at the Port a specific JBER location during utility outages, while also delivering economic value during blue-sky conditions. The study aims to estimate the size, configuration and concept of operations based on existing infrastructure and limited demand data. It also explores potential project benefits and challenges. The report goal is to inform further stakeholder consultation and next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overview of Preliminary Concepts for a Port of Alaska Resilient Microgrid

The Port of Alaska in Anchorage enables the economic vitality of the Municipality of Anchorage and State of Alaska. It also provides significant support to defense activities across Alaska, especially to the Joint Base Elmendorf-Richardson (JBER) that is immediately adjacent to the Port. For this reason, stakeholders are interested in the resilience of the Ports operations. This report documents a preliminary feasibility analysis for developing an energy system that increases electric supply resilience for the Port and for a specific location inside JBER. The project concept emerged from prior work led by the Municipality of Anchorage and consultation with Port stakeholders. The project consists of a microgrid with PV, storage and diesel generation, capable of supplying electricity to loads at the Port a specific JBER location during utility outages, while also delivering economic value during blue-sky conditions. The study aims to estimate the size, configuration and concept of operations based on existing infrastructure and limited demand data. It also explores potential project benefits and challenges. The report goal is to inform further stakeholder consultation and next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Network Reduction for Power Hardware-in-the-Loop Simulation

This paper proposes single-port equivalent and two-port equivalent network reduction methods to respectively reduce single-port and two-port areas in a large power network. Parameters of the reduced systems are rigorously derived, which guarantees that the electrical quantities at the port(s) remain unchanged over the reduction, including voltage magnitude and phase and active and reactive power injections into the area to be reduced. The proposed techniques are applied to reduce a practical Maui grid, where the total numbers of buses, lines and transformers are respectively reduced from 212, 106 and 108 to 45, 30 and 13. Dynamic behaviors between the full model and the reduced model are compared in detail to illustrate the efficacy and accuracy of the proposed network reduction.

model reduction↗

Power System Network Reduction for Power Hardware-in-the-Loop Simulation: Preprint

This paper proposes a single-port equivalent and a two-port equivalent to respectively reduce single-port and two-port areas in a large power network. Parameters of the reduced systems are rigorously derived, which guarantees that the electrical quantities at the port remain unchanged over the reduction, including voltage magnitude and phase, active and reactive power injections into the area to be reduced. The proposed techniques are applied to reduce a practical Maui grid, where the total numbers of buses, lines and transformers are respectively reduced from 212, 106 and 108 to 45, 30 and 13. Dynamic behaviors between the full model and the reduced model are compared in detail to illustrate the efficacy and accuracy of the proposed network reduction.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Network Reduction for Power Hardware-in-the-Loop (PHIL) Simulation

This paper proposes single-port equivalent and two-port equivalent network reduction methods to respectively reduce single-port and two-port areas in a large power network. Parameters of the reduced systems are rigorously derived, which guarantees that the electrical quantities at the port(s) remain unchanged over the reduction, including voltage magnitude and phase and active and reactive power injections into the area to be reduced. The proposed techniques are applied to reduce a practical Maui grid, where the total numbers of buses, lines and transformers are respectively reduced from 212, 106 and 108 to 45, 30 and 13. Dynamic behaviors between the full model and the reduced model are compared in detail to illustrate the efficacy and accuracy of the proposed network reduction.

41 EE - Solar Energy Technologies Office (EE-4S)↗