SEARCH · Search NASA
Results for “FIRST ROBOTICS”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Analysis of the Impact of Radiation on Cameras and Robotic Perception - 19242
Robotic systems are increasingly used for inspection, maintenance, and disaster assistance for nuclear power plants. These robots utilize increasingly high levels of autonomy to operate in environments that are unsafe for humans to operate the robot in or require more precise control over the robot than a human can offer. In these cases, the robot must include perception and computation components to autonomously sense and navigate through the environment to fulfill its mission. This difficult task is complicated by radiation interfering with sensors' operation. The impact of this interference is largely unexplored, as existing works on radiation interference on sensors focus on estimating the incident radiation, rather than how it impacts a robotic system using the sensor. In this work, we seek to quantify and describe the impact of radiation on cameras, and how the radiation affects robotic performance. In this paper we study cameras that are suitable for small, lightweight unmanned aerial vehicles (UAVs) that are increasingly deployed to fly in confined areas in emergencies, where the surrounding environment is unsafe for workers to operate. These small UAVs lack the payload capacity to carry significant radiation shielding, so any onboard sensors will be affected by radiation. In the case of cameras, this radiation appears as noise in the camera imagery. This noise will interfere with the UAV's operation, by obscuring obstacles and interfering with localization and optical flow algorithms that detect detailed features in the environment. To date, there is a lack of information on how the radiation noise in the camera image impacts the overall robot system performance Existing work focuses on estimating the amount of incident radiation by measuring the corruption in the images. However, these works suffer several shortcomings for robotic systems. First, a robot must be able to successfully navigate its environment during a successful mission, and merely quantifying the amount of radiation noise in an image does not adequately explain how it may interfere with higher level navigation and perception tasks. Second, radiation estimation procedures rely on focusing the camera on a known and static background. This is unsuitable for robotic exploration tasks, where the robot frequently moves around an unknown environment that may be dynamically changing. Our work contains two contributions that address these shortcomings. First, we conduct a detailed analysis of the noise radiation causes in cameras by exposing cameras that are commonly used on UAVs [e.g., small form factor complementary metal-oxide-semiconductor (CMOS) cameras] to varying levels of radiation that may be present in emergency scenarios. From this exposure, we quantify not only how much noise is present, but quantify its appearance. By quantifying the appearance and amount of noise in a camera image, researchers can design mitigation strategies for the corruption, so that their robotic systems can operate in these challenging environments. Second, we demonstrate how to leverage this experimental data in robotic simulations. Using data from the first set of experiments allows us to test and verify the robots in simulation. Using simulators allows us to verify the robots will perform as expected during critical times without needing expensive test equipment or damaging valuable robot prototypes. Other researchers using robots for exploration of irradiated environments will benefit from our research by incorporating similar noise models in their research. 1 Southwest Research Institute{sup R} is a registered trademark of Southwest Research Institute in the United States and/or other countries. This will increase the reliability of robotic systems prior to deployment in emergency situations, which will in turn increase their effectiveness and speed the development of robots that would otherwise need expensive and time-consuming test procedures to validate. (authors)
TORONE: Total Characterisation by Remote Observation of Nuclear Environments - 20591
This paper describes the autonomous robotic systems developed in the TORONE project (Total Characterisation by Remote Observation of Nuclear Environments) for combined characterisation by remote techniques in nuclear environments. There are four main components to the system. Firstly, robot operation which uses a Robot Operating System (ROS) allowing ease of communication between hardware and software alongside robot vision systems such as Lidar and/or photogrammetry. Secondly, radiation detection instrumentation for gamma and neutron sources which is also collimated for spatial resolution. Thirdly, photonic characterisation instrumentation for remote material identification by means of Raman spectroscopy and Laser induced breakdown spectroscopy (LIBS). Finally, a data management system is described which contains the TORONE characterisation data with the ability to overlay material characterisation information onto 3D maps of the nuclear environment. Preliminary results are described alongside discussion of some of the synergies of the combined approach. There are many applications of such an autonomous system in nuclear decommissioning, waste management and asset management. (authors)
A SURVEY OF THE HIGH ORDER MULTIPLICITY OF NEARBY SOLAR-TYPE BINARY STARS WITH Robo-AO
We conducted a survey of nearby binary systems composed of main sequence stars of spectral types F and G in order to improve our understanding of the hierarchical nature of multiple star systems. Using Robo-AO, the first robotic adaptive optics instrument, we collected high angular resolution images with deep and well-defined detection limits in the Sloan Digital Sky Survey i' band. A total of 695 components belonging to 595 systems were observed. We prioritized observations of faint secondary components with separations over 10'' to quantify the still poorly constrained frequency of their subsystems. Of the 214 secondaries observed, 39 contain such subsystems; 19 of those were discovered with Robo-AO. The selection-corrected frequency of secondary subsystems with periods from 10{sup 3.5} to 10{sup 5} days is 0.12 ± 0.03, the same as the frequency of such companions to the primary. Half of the secondary pairs belong to quadruple systems where the primary is also a close pair, showing that the presence of subsystems in both components of the outer binary is correlated. The relatively large abundance of 2+2 quadruple systems is a new finding, and will require more exploration of the formation mechanism of multiple star systems. We also targeted close binaries with periods less than 100 yr, searching for their distant tertiary components, and discovered 17 certain and 2 potential new triples. In a subsample of 241 close binaries, 71 have additional outer companions. The overall frequency of tertiary components is not enhanced, compared to all (non-binary) targets, but in the range of outer periods from 10{sup 6} to 10{sup 7.5} days (separations on the order of 500 AU), the frequency of tertiary components is 0.16 ± 0.03, exceeding the frequency of similar systems among all targets (0.09) by almost a factor of two. Measurements of binary stars with Robo-AO allowed us to compute first orbits for 9 pairs and to improve orbits of another 11 pairs.
Wearable robotic systems for supporting a load
Wearable robotic systems including robotic limbs for supporting a load while a user moves through an environment and their methods of use are described. In one embodiment, a robotic system includes robotic limbs with first and second robotic limb segments that are movable between different configurations to support a load while a user is standing or crawling. In another embodiment, a robotic system includes first and second robotic limbs that are substantially located within a plane parallel to a frontal plane of a user when the robotic system is worn. In another embodiment, a wearable robotic system includes first and second robotic limbs and an associated base that is attachable to a user's torso. The first and second robotic limbs may include a plurality of actuators and associated robotic limb segments to couple the robotic legs to the base and control their movement.
Review on robot-assisted polishing: Status and future trends
Nowadays, precision components have been extensively used in various industries such as biomedicine, photonics, and optics. To achieve nanometric surface roughness, high-precision polishing is mandatory. Compared with the conventional polishing techniques, the robot-assisted polishing has the advantages of flexible working ranges and low cost. Therefore, it has been more widely deployed in demanding polishing tasks. However, few review articles were found on this topic to provide a general progress on the development of the robot-assisted polishing technology. Here in this paper reviews the recent advancement of the robot-assisted polishing. Firstly, the integration of robots with various polishing techniques is overviewed, followed by the introduction of the research status of constant force control in robot-assisted polishing. Then, the errors in typical robot-assisted polishing systems are analyzed, together with the corresponding compensation methods. At last, the future trends in the development of robot-assisted polishing are discussed. This review is intended as a roadmap for researchers or engineers who are interested in robot-assisted polishing or machining.
Spot Robot Staffing Augmentation in Process Modeling and Analysis (E-2) [Slides]
In September 2021 E-2 obtained its first Spot robot from Boston Dynamics to evaluate their suitability for work in and around laboratory facilities. Spot is a highly mobile quadruped robot capable of up to 90 minutes of operation. They can be outfitted with payloads up to 30 pounds and support Boston Dynamics-developed equipment, third party payloads, or custom-developed payloads. The platform showed immediate promise resulting in the procurement of a total of four units by the end of FY22 (Trinity, Gadget, Crossroads, and Sandstone).
Characteristics and performance of the first commercial multileaf collimator for a robotic radiosurgery system
Purpose: The “InCise™ multileaf-collimator (MLC)” is the first commercial MLC to be mounted on a robotic SRS/SBRT platform (CyberKnife). The authors assessed characteristics and performance of this novel device in a preclinical five months test period. Methods: Commissioning beam data were acquired with unshielded diodes. EBT3 radiochromic films were employed for measurement of transmission, leaf/bank position accuracy (garden fence) before and after exercising the MLC, for end-to-end testing and further characterization of the beam. The robot workspace with MLC was assessed analytically by transformation to an Euler geometry (“plane,” “gantry,” and “collimator” angles) and by measuring pointing accuracy at each node. Stability over time was evaluated in picket fence and adapted Winston–Lutz tests (AQA). Results: Beam penumbrae (80%–20%, with 100% = 2 × dose at inflection point for field sizes ≥ 50 × 50 mm{sup 2}) were 2.2–3.7 mm for square fields in reference condition (source-axis-distance 800 mm, depth 15 mm) and depended on field size and off-axis position. Transmission and leakage did not exceed 0.5%. Accessible clinical workspace with MLC covered non-coplanar gantry angles of [−113°; +112°] and collimator angles of [−100°; +107°], with an average robot pointing accuracy of 0.12 ± 0.09 mm. For vertical beams, garden fence tests exhibited an average leaf positioning error of ≤0.2 mm, which increased by 0.25 and 0.30 mm (banks X1 and X2) with leaves traveling parallel to gravity. After execution of a leaf motion stress routine, garden fence tests showed slightly increased jaggedness and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.38 ± 0.05 mm in nine end-to-end tests. Picket fence and AQA tests displayed stable results over the test period. Conclusions: The InCise™ MLC for CyberKnife showed high accuracy and adequate characteristics for SRS/SBRT applications. MLC performance after exercise demands specific quality assurance measures.
Robotic surgical devices, systems and related methods
Various medical devices and related systems, including robotic and/or in vivo medical devices, and various robotic surgical devices for in vivo medical procedures. Included herein, for example, is a robotic surgical system having a support beam positionable through an incision, and a robotic device having a device body, first and second rotating shoulder components coupled to the device body, and first and second robotic arms coupled to the first and second shoulder components, respectively.
GRANT: Ground-Roaming Autonomous Neuromorphic Targeter
In this work we describe the design, implementation, and testing of the first neuromorphic robot capable of obstacle avoidance, grid coverage, and targeting controlled by the second generation Dynamic Adaptive Neural Network Array (DANNA2) digital spiking neuromorphic processor. The simplicity of the DANNA2 processor along with the TENNLab hardware/software co-design framework allows for compact spiking networks that can run efficiently on a small, resource-constrained, platform such as a Xilinx Artix-7 field-programmable gate array. Additionally, we present the dynamic reconfigurability of DANNA2 arrays as a method of realizing complex, multi-objective tasks on hardware that is restricted to relatively small networks.
SU-C-BRB-04: Characteristics and Performance Evaluation of the First Commercial MLC for a Robotic Delivery System
Purpose: To assess characteristics and performance of the “Incise™” MLC (41 leaf pairs, 2.5mm width, FFF linac) mounted on the robotic SRS/SBRT platform “CyberKnife M6™” in a pre-clinical 5 months (11/2014–03/2015) test period. Methods: Beam properties were measured with unshielded diodes and EBT3 film. The CyberKnife workspace for MLC was analyzed by transforming robot node coordinates (cranial / body paths) into Euler geometry. Bayouth tests for leaf / bank position accuracy were performed in standard (A/P) and clinically relevant non-standard positions, before and after exercising the MLC for 10+ minutes. Total system and delivery accuracy were assessed in End-to-End tests and dosimetric verification of exemplary plans. Stability over time was evaluated in Picket-Fence-and adapted Winston-Lutz-tests (AQA) for different collimator angles. Results: Penumbrae (80–20%, with 100%=2*dose at inflection point; SAD 80cm; 10cm depth) parallel / perpendicular to leaf motion were 2.87/2.64mm for the smallest (0×76×0.75cm{sup 2}) and 5.34/4.94mm for the largest (9.76×9.75cm{sup 2}) square field. MLC circular field penumbrae exceeded fixed cones by 10–20% (e.g. 60mm: 4.0 vs. 3.6mm; 20mm: 3.6 vs. 2.9mm). Interleaf leakage was <0.5%. Clinically accessible workspace with MLC covered (non-coplanar) gantry angles of [-113°;+112°] (cranial) and [-108°;+102°] (body), and collimator angles of [-100°;+107°] (cranial) and [-91°;+100°] (body). Average leaf position offsets were ≤0.2mm in 14 standard A/P Bayouth tests and ≤0.6mm in 8 non-standard direction tests. Pre-test MLC exercise increased jaggedness (range ±0.3mm vs. ±0.5mm) and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.39±0.06mm in 6 End-to-End tests. Picket-Fence and AQA showed no adverse trends during the test period. Conclusion: The Incise™ MLC for CyberKnife M6™ displayed high accuracy and mechanical stability over the test period. The specific CyberKnife geometry and performance after exercise demand dedicated QA measures. This work is in part funded by a research grant from Accuray Inc, Sunnyvale, USA. Erasmus MC Cancer Institute also has research collaborations with Elekta AB, Stockholm, Sweden. C Fuerweger has previously received speaker honoraria from Accuray Inc, Sunnyvale, USA.
The First Human Trial of Transoral Robotic Surgery Using a Single-Port Robotic System in the Treatment of Laryngo-Pharyngeal Cancer
Background: This study aimed to evaluate the feasibility and safety of the DaVinci SP system for performing transoral robotic surgery (TORS) in patients with head and neck cancer. Methods: From October 2018 to April 2019, the medical records of 41 patients who underwent TORS using the DaVinci SP system were retrospectively reviewed. Results: During TORS, three robotic arms could be used to perform a geometric resection of the lesion in a narrow working space. The mean total operation time was 60 min, and the average time required to set up the robotic system was 10 min or less. All patients successfully underwent TORS. All robotic arms were inserted through a single port, which widened the working space around the patient’s head and allowed the operative assistant an easy approach to the patient during the operation. The joggle joint of the robotic arms aided easy manipulation within the confined working space. The joggle joints of the endoscopic arm were controlled through the navigation system, which was very helpful in securing superior visualization of the surgical site, especially in the area of the larynx and the hypopharynx. Conclusion: The study confirmed that the DaVinci SP system provided technical advantages above the Si and Xi systems for performing TORS. It was especially helpful in ensuring proper visualization of the surgical field and in performing precise surgery during surgery to the tongue base or the hypopharyngeal lesion.
System and method for controlling a vision guided robot assembly
A method includes the following steps: actuating a robotic arm to perform an action at a start position; moving the robotic arm from the start position toward a first position; determining from a vision process method if a first part from the first position will be ready to be subjected to a first action by the robotic arm once the robotic arm reaches the first position; commencing the execution of the visual processing method for determining the position deviation of the second part from the second position and the readiness of the second part to be subjected to a second action by the robotic arm once the robotic arm reaches the second position; and performing a first action on the first part using the robotic arm with the position deviation of the first part from the first position predetermined by the vision process method.
Highly mobile robot for remote inspection
A robotic vehicle can include a plurality of motors coupled to a plurality of gearboxes, each gearbox of the plurality of gearboxes configured to be rotated, a plurality of nested driveshafts coupled to the plurality of gearboxes and including at least a first driveshaft and a second driveshaft, and a plurality of appendages operably coupled to the plurality of gearboxes. A particular appendage of the plurality of appendages can be configured to be rotated in response to a rotational motion of the first driveshaft. The robotic vehicle can include a plurality of wheels coupled to the plurality of appendages and configured to rotate about a plurality of wheel axles. Each wheel of the plurality of wheels can be configured to cause the robotic vehicle to be transported across a contacting surface in response to the rotational motion of the second driveshaft.
Apparatus and method for agricultural data collection and agricultural operations
Aspects of the subject disclosure may include, for example, obtaining video data from a single monocular camera, wherein the video data comprises a plurality of frames, wherein the camera is attached to a mobile robot that is travelling along a lane defined by a row of crops, wherein the row of crops comprises a first plant stem, and wherein the plurality of frames include a depiction of the first plant stem; obtaining robot velocity data from encoder(s), wherein the encoder(s) are attached to the robot; performing foreground extraction on each of the plurality of frames of the video data, wherein the foreground extraction results in a plurality of foreground images; and determining, based upon the plurality of foreground images and based upon the robot velocity data, an estimated width of the first plant stem. Additional embodiments are disclosed.
System and method for member articulation
A system including a robot mean to move a member by using a first camera coupled to the robot, a second camera coupled to the robot, a control device configured to control position of the robot in order to minimize a pixel-wise distance between the member and a target based on alternating input from the first camera and the second camera.
Robotic Assisted Non-Destructive Testing (NDT)
Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.
Robotic D and D: Smart robots - 15093
Project' managers continually seek an ever-greater optimization of time between remote handling operations and those carried out manually; therefore, new technological solutions must be deployed. Robotics offers a great opportunity in this new field of technology to carry out, for example, samplings or remediation in hostile, cluttered surroundings. Teams in charge of dismantling at the CEA have therefore first defined robotizable functions. These functions have been assembled from existing technological blocks to arrive at robots which are operating today [RICAIII, patent: FR 2925702]. Lessons learned, particularly from experience with the RICA robot, have enabled the operating technical specifications to be fine-tuned. A new study phase has been launched applying the same principle of adapting existing, proven means. The growing role of robotics today is unquestioned. Led by research and the academic world; robots such as those equipped with wheels, tracks, feet or even helicopter rotors, are today accessible to the general public, particularly via broadening of the 'open source' concept. Added to these we need tools able to manage large component deconstruction systems, like MAESTRO. Industrialization of such high-potential technological solutions has been aided by: - Easy use, - Increasing reliability, - Flexibility of 'open source' solutions, - Widening skill networks, and therefore greater technical support - Lower costs. Decontamination and dismantling (D and D) projects must be able to meet a number of special demands, increasing the number of unit designs, their costs and delivery times. The complexity of dismantling works sites mean that each is a special case to be dealt with almost independently. Such a way of approaching these projects is not on the same wavelength as industry, with tool and method standardization. The answer to the challenge of operations in difficult environments is an eco-system of functions, performed by a set of inter-connected robots. The first step towards the construction of such robot teams is devoted to functions where strength is not necessary: investigating and clean-up in hostile environments. With this in mind, the CEA Marcoule teams have been given the objective of merging the strengthening commercial robotic world with the needs of D and D, and thus to improve the transversal use of the systems. (authors)