At least 19 records

Loose Belt Fault Detection and Virtual Flow Meter Development Using Identified Data-driven Energy Model for Fan Systems

An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable-frequency drives (VFDs) makes the motor-efficiency data published by manufacturers inapplicable for VFD–motor–fan systems, the fan efficiency and drive (belt–motor–VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD–motor–fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency, and drive-efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then, the energy model is identified for an existing VFD–motor–fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD–motor–fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.

42 ENGINEERING↗

Impact of ceiling fan and room air cleaner on air mixing and fate of particulate matter in a multiroom residence

We are exposed to airborne particles of health concern in residences, and Room Air Cleaners (RACs) can remove these particles. However, they are often limited to treating local air in the room or near vicinity of the device. RAC performance in multi-room residences may be improved by ceiling fan whole-house air mixing with a minor increase in energy use. Here, this study analyzed air quality and energy efficiency from experimental measurements using combinations of ceiling fan and RAC operation. We measured removal rates of tracer gas and particles from ultrafine to 5 µm after their release in the kitchen area of a multiroom test house. Results show that the air mixing by ceiling fans increased ultrafine and > 1 µm particle removal over the baseline – with no ceiling fans and no RAC – suggesting increased deposition onto the ceiling fan blades and house surfaces. Also, ceiling fan mixing increased particle removal in all size bins over the RAC performance with no ceiling fans. The removal rate with ceiling fans and the RAC was greater than the sum of the rates from each operating alone, indicating that synergistic interactions between the ceiling fans and the RAC increased the RAC filtration rate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

An algorithmic approach to predicting mechanical draft cooling tower fan speeds from infrasound signals

Mechanical draft cooling towers (MDCTs) serve a critical heat management role in a variety of industries. For nuclear reactors in particular, the consistent, predictable operation of MDCTs is required to avoid damage to infrastructure and reduce the potential for catastrophic failure. Accurate, reliable measurement of MDCT fan speed is therefore an important maintenance and safety requirement. To that end, we have developed an algorithm for automatically predicting the rotational speeds of multiple, simultaneously operating fan rotors using contactless, infrasound measurements. The algorithm is based on identifying the blade passing frequencies (BPFs), their harmonics, as well as the motor frequencies (MFs) for each fan in operation. Using the algorithm, these frequencies can be automatically identified in the acoustic waveform’s short-time Fourier transform spectrogram. Attribution is aided by a set of filters that rely on the unique spectral and temporal characteristics of fan operation, as well as the intrinsic frequency ratios of the BPF harmonics and the BPF/MF signals. The algorithm was tested against infrasound data acquired from infrasound sensors deployed at two research reactors: the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL) and the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory (ORNL). After manually identifying the MDCT gearbox ratio, the algorithm was able to quickly yield fan speeds at both reactors in good agreement with ground truth. Ultimately, this work demonstrates the ease by which MDCT fans may be monitored in order to optimize operational conditions and avoid infrastructure damage.

42 ENGINEERING↗

Reliability Assessment of Cooling Fans for PV Inverters: Testing, Modeling, and Case Studies

The reliability of photovoltaic (PV) inverters is critical for long-term solar system performance, with cooling fan failures frequently leading to costly downtime. While much research exists on general cooling fan reliability, little attention has been given to fans operating within PV inverters and their unique environmental challenges. Here, this article proposes a comprehensive methodology to address this gap. First, a failure mode and effects analysis is performed on fans to identify the key failure mechanisms in PV applications, their corresponding stressors, and the models necessary for lifetime prediction. Second, an accelerated life test is designed and conducted to collect valuable experimental data for PV inverter fans in a reasonable amount of time. Third, a mathematical conversion of dynamic mission profiles into effective constant stress levels is derived. Fourth, case studies are given, showcasing lifetime estimates that account for geographic variations in mission profile data. The results demonstrate that this integrated approach leads to an accurate reliability assessment for PV inverter cooling fans.

accelerated life testing (ALT)↗

Fan and Pump Efficiency in Modelica based on the Euler Number

Simulation programs often assume constant hydraulic efficiency for fan or pump models when performance curves are unavailable. This is inaccurate because the hydraulic efficiency varies with the operation condition. It therefore consistently underestimates the power draw at off-design conditions at which the hydraulic efficiency drops. Use of a modified Euler number allows computing the hydraulic efficiency and shaft power with limited data. Others showed the validity of the modified Euler number for fan efficiency calculations. We show that it is also applicable for pumps, and present its implementation in Modelica for a fan or pump model. Here, the only input required from the user is one data point at which the hydraulic efficiency is at its maximum. The reported method is applicable regardless of the type, size, or operational region of the fan or pump. Across a sample of eighteen sets of pump data and seven sets of fan data, the errors of the computed power from interpolated data were within 15% for the range of 20% - 70% of maximum flow rate and 40% - 90% of maximum pressure rise, excluding outliers.

component model↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Primary Pump Motor Area - Transfer Fan Replacement PLC Design

My poster is about a project that I have worked on in my time at ATR as an intern. The Heating and Ventilation Control Panel (HVB-1) controls thirty-five heating and ventilation fans within the Advanced Test Reactor. This control panel needs replacement, as many of the components inside the existing panel are becoming old and degrading. In preparation for this replacement effort, concepts and component identification for the new control panel needed to be developed. Instead of replacing the new panel with replacement mechanical components, a Programmable Logic Controller (PLC) is proposed as a solution. Although multiple fans are associated with this panel, my poster focuses on the replacement design for the Primary Pump Motor Area Transfer Fan. This will provide an example of how the entire cabinet may be upgraded.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monitoring Warm Wastewater and Evaporation Fans - A Brilliant Duo

The Advanced Test Reactor (ATR) generates warm wastewater which must be stored in warm wastewater ponds. The goal is to evaporate the water from the ponds and using evaporation fans may help to accomplish this. This project explores how much water has been accumulated into the ponds along with how much water has been entering and leaving the ponds over the past 5 years. Furthermore, the implementation of the evaporation fans into the ponds is evaluated to see if they are helpful for improving evaporation rates or not.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing of Portable Air Cleaner Products for Energy Efficiency and Clean Air Performance at Various Fan Settings [Slides]

This document contains the results of a product review and laboratory testing experiment of portable air cleaning devices (PACs). Thirty-four commercially available PACs were reviewed, and from those, 7 products were purchased and underwent AHAM AC-7 clean air delivery rate (CADR) testing. The following research questions were explored: 1) What is the relationship between clean air delivery rate (CADR) and energy across a range of products and what is the general decrement in CADR as a result of operating at lower fan speeds? 2) How might the multiple units at lower power compare to fewer, larger units at full power in terms of energy efficiency and total cost? 3) How do the measured CADR, power, and efficiency compare to the manufacturer specs? 4) Are there product attributes that can be identified that might contribute to better CADR/W performance?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The velocity uniformity and flow angle results from the 3430 stack verification tests, performed in April 2023, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 2.1 %COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20 %COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack (i.e., CFD modeled stack); in this case the CFD modeled average result of 2.85 %COV for the nominal operating range of 22,800 cfm to 62,400 cfm. Additionally, the measured average flow angle at the 3430 stack monitor location was 5.6 degrees. The result is =20 degrees, so the criterion is met.

3430 Building↗

Slant, Fan, and Narrow: The Response of Stellar Streams to a Tilting Galactic Disk

Stellar streams are sensitive tracers of the gravitational potential, which is typically assumed to be static in the inner Galaxy. However, massive mergers like Gaia-Sausage-Enceladus can impart torques on the stellar disk of the Milky Way that result in the disk tilting at rates of up to 10°–20° Gyr –1 . Here, we demonstrate the effects of disk tilting on the morphology and kinematics of stellar streams. Through a series of numerical experiments, we find that streams with nearby apocenters (r apo ≲ 20 kpc) are sensitive to disk tilting, with the primary effect being changes to the stream's on-sky track and width. Interestingly, disk tilting can produce both more diffuse streams and more narrow streams, depending on the orbital inclination of the progenitor and the direction in which the disk is tilting. Our model of Pal 5's tidal tails for a tilting rate of 15° Gyr –1 is in excellent agreement with the observed stream's track and width, and reproduces the extreme narrowing of the trailing tail. We also find that failure to account for a tilting disk can bias constraints on shape parameters of the Milky Way's local dark matter distribution at the level of 5%–10%, with the direction of the bias changing for different streams. Disk tilting could therefore explain discrepancies in the Milky Way's dark matter halo shape inferred using different streams.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

symPACK: A GPU-Capable Fan-Out Sparse Cholesky Solver

Sparse symmetric positive definite systems of equations are ubiquitous in scientific workloads and applications. Parallel sparse Cholesky factorization is the method of choice for solving such linear systems. Therefore, the development of parallel sparse Cholesky codes that can efficiently run on today’s large-scale heterogeneous distributed-memory platforms is of vital importance. Modern supercomputers offer nodes that contain a mix of CPUs and GPUs. To fully utilize the computing power of these nodes, scientific codes must be adapted to offload expensive computations to GPUs. We present symPACK, a GPU-capable parallel sparse Cholesky solver that uses one-sided communication primitives and remote procedure calls provided by the UPC++ library. We also utilize the UPC++ "memory kinds" feature to enable efficient communication of GPU-resident data. We show that on a number of large problems, symPACK outperforms comparable state-of-the-art GPU-capable Cholesky factorization codes by up to 14x on the NERSC Perlmutter supercomputer.

Bellavita, Julian↗