Comparison of Feschenko BSM and Fast Faraday Cup with Low Energy Ion Beams

A comparison between Fast Faraday Cup and Feschenko longitudinal bunch shape detectors was recently performed at HELIAC Advanced Demonstrator beamline at GSI. Feschenko bunch shape monitor (BSM) uses the time to space conversion by means of secondary electrons emitted from a wire correlated to a rf deflector, while the fast Faraday cup (FFC) measures the deposited charge in a cup geometry matched to 50 Ohm. The FFC design aims to minimize the bunch shape dilution due to field polarization and secondary electrons produced on irradiation. An He¹⁺ with 100 µA average current and 1.4 MeV/u kinetic energy is utilized for this comparison. A buncher upstream of the detectors was operated to focus the beam longitudinally. The results are discussed in this contribution.

43 PARTICLE ACCELERATORS↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Faraday cup for measuring the longitudinal distribution of particle charge density in non-relativistic beams

A Fast Faraday cup includes a group of electrodes including a ground electrode having a through hole and a collector electrode configured with a blind hole that functions a collector hole. The electrodes are configured to allow a beam (e.g., a non-relativistic beam) to fall onto the ground electrode so that the through hole cuts a beamlet that flies into the collector hole and facilitates measurement of the longitudinal distribution of particle charge density in the beam. The diameters, depths, spacing and alignment of the collector hole and the through hole are controllable to enable the Fast Faraday day cup to operate with a fast response time (e.g., fine time resolution) and capture secondary particles.

Sun, Ding↗

Fast faraday cup for measuring the longitudinal distribution of particle charge density in non-relativistic beams

A Fast Faraday Cup includes a group of electrodes including a grounded electrode having a through hole and a collector electrode configured with a blind hole that functions a collector hole. The electrodes are configured to allow a beam (e.g., a non-relativistic beam) to fall onto the grounded electrode so that the through hole cuts a beamlet that flies into the collector hole and facilitates measurement of the longitudinal distribution of particle charge density in the beam. The diameters, depths, spacing and alignment of the collector hole and the through hole are controllable to enable the Fast Faraday day cup to operate with a fast response time (e.g., fine time resolution) and capture secondary particles.

Sun, Ding↗

Improvements to the Faraday cup fast ion loss detector and magnetohydrodynamic induced fast ion loss measurements in Joint European Torus plasmas

Upgrades to electronic hardware and detector design have been made to the JET thin-foil Faraday cup fast ion loss detector in anticipation of the upcoming deuterium–tritium (DT) campaign. An improved foil stack design has been implemented, which greatly reduces the number of foil-to-foil shorts, and triaxial cabling has mitigated ambient noise pickup. Initial tests of 200 kHz digitizers, as opposed to the original 5 kHz digitizers, have provided enhanced analysis techniques and direct coherence measurements of fast ion losses with magnetohydrodynamic activity. Here, we present recent loss measurements in JET deuterium plasmas correlated with kink modes, fishbone modes, edge-localized modes, and sawteeth. Sources of systematic noise are discussed with emphasis on capacitive plasma pickup. Overall, the system upgrades have established a diagnostic capable of recording alpha particle losses due to a wide variety of resonant fast ion transport mechanisms to be used in future DT-experiments and modeling efforts.

47 OTHER INSTRUMENTATION↗

Lost alpha Faraday cup foil noise characterization during Joint European Torus plasma post-processing analysis

Capacitive plasma pickup is a well-known and difficult problem for plasma-facing edge diagnostics. This problem must be addressed to ensure an accurate and robust interpretation of the real signal measurements vs noise. The Faraday cup fast ion loss detector array of the Joint European Torus (JET) is particularly prone to this issue and can be used as a testbed to prototype solutions. The issue of separation and distinction between warranted fast ion signal and electromagnetic plasma noise has traditionally been solved with hardware modifications, but a more versatile post-processing approach is of great interest. This work presents post-processing techniques to characterize the signal noise. While hardware changes and advancements may be limited, the combination with post-processing procedures allows for more rapid and robust analysis of measurements. The characterization of plasma pickup noise is examined for alpha losses in a discharge from JET’s tritium campaign. In addition to highlighting the post-processing methodology, the spatial sensitivity of the detector array is also examined, which presents significant advantages for the physical interpretation of fast ion losses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geant4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complexby replacing the current linear accelerator (linac) with awarm front end (WFE) capable of accelerating H- beamsup to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To preciselymeasure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wirescanners along the superconducting linac are planned forimplementation. This investigation is centered on refiningthe Faraday cup design for the PIP-II Laser wire scannersby utilizing GEANT4, a Monte Carlo simulation toolkit.Leveraging this method enables a comprehensive analysisof particle trajectories, energy deposition, secondary particle emission, backscattering, etc., facilitating optimizationthrough adjustments to cup geometries, materials, andplacement to maximize its efficacy in beam diagnostics.

43 PARTICLE ACCELERATORS↗

GEANT4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The PIP-II accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complex by replacing the current linear accelerator with a warm front end (WFE) capable of accelerating H- beams up to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To precisely measure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wire scanners along the superconducting linac are planned for implementation. This investigation centers on refining the Faraday cup design for the PIP-II Laser wire scanners by utilizing GEANT4, a Monte Carlo simulation toolkit. Leveraging this method enables a comprehensive analysis of particle trajectories, energy deposition, secondary electron emission, backscattering, etc., facilitating optimization through adjustments to cup geometries, materials, and placement to maximize its efficiency.

43 PARTICLE ACCELERATORS↗

Geant4-based Analysis of Faraday Cup Performance for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab marks a significant advancement in high-energy physics research. This initiative aims to enhance Fermilab's accelerator complex by replacing the existing linear accelerator (linac) with a warm front end (WFE) capable of accelerating H- beams up to 2.1 MeV. Subsequently, a superconducting linac (SCL), that further accelerates these beams up to 800 MeV. To accurately measure the transverse beam profile, traditional wire scanners will be utilized in the WFE section, while Laser wire scanners will be implemented along the SCL. The Faraday cup for the Laser wire scanners has been designed using the GEANT4 simulation toolkit. This poster presents a detailed analysis of its performance along the SCL, focusing on electron absorption, secondary electron emission, backscattering, etc.

Wijethunga, S. A.K.↗

Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS

In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing↗

Study of the Design and Characteristics of a Modified Pulsed Plasma Thruster with Graphite and Tungsten Trigger Electrodes

The paper presents experimental results for a modified pulsed plasma thruster (PPT) with solid propellant, using a coaxial anode–cathode design. Graphite from pencil leads served as propellant, and a tungsten trigger electrode was tested to reduce carbonization effects. Experiments were performed in a vacuum chamber at 0.001 Pa, employing diagnostics such as discharge current/voltage recording, power measurement, ballistic pendulum, time-of-flight (TOF) method, and a Faraday cup. Current and voltage waveforms matched an oscillatory RLC circuit with variable plasma channel resistance. Key discharge parameters were measured, including current pulse duration/amplitude and plasma channel formation/decay dynamics. Impulse bit values, obtained with a ballistic pendulum, reached up to 8.5 μN·s. Increasing trigger capacitor capacitance reduced thrust due to unstable “pre-plasma” formation and partial pre-discharge energy loss. Using TOF and Faraday cup diagnostics, plasma front velocity, ion current amplitude, current density, and ion concentration were determined. Tungsten electrodes produced lower charged particle concentrations than graphite but offered better adhesion resistance, minimal carbonization, and stable long-term performance. The findings support optimizing trigger electrode materials and PPT operating modes to extend lifetime and stabilize thrust output.

Faraday cup↗

Analysis of fusion alphas interaction with RF waves in D-T plasma at JET

This work studies the influence of RF waves in ICRH range of frequency on fusion alphas during the recent JET D-T campaign. Fusion alphas from D-T reactions are born with energies of about 3.5MeV and therefore have significant Doppler shift enabling synergistic interaction between them and RF waves at broad range of frequencies including the ones foreseen for future fusion machines ITER and SPARC. Resonant interaction between RF waves and alphas, also called synergistic effects, will modify the alpha distribution and ultimately will have an impact on alpha orbit losses and heating. Data from JET 3.43T/2.3MA pulses based on the hybrid scenario during the DTE2 campaign were used for the analysis in this study. The impact of synergistic effects on alpha orbit losses and alpha heating is assessed. Conclusions are based on analysis of experimental data for fast alphas losses, i.e. measurements from neutral particle analyser, fast ion losses scintillator detector, Faraday cups, and TRANSP simulations. Experimental data and TRANSP analysis indicate that there are indeed changes in the alphas' distribution function due to interaction with RF waves. Data from the scintillator detector and the Faraday cups were compared for pulses with and without ICRH power and versus cases with enhanced alpha losses due to MHD activities. The trends from these diagnostics consistently show no additional alpha losses due to interaction with RF waves. TRANSP predictions for the impact of the synergistic effects on alpha heating show up to 42% increase in alpha electron heating and up to 25% increase in alpha ion heating. These effects however become negligibly small, less than 1%, when alpha heating is compared to the total auxiliary hearting power in the investigated JET pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Features of ion generation by a picosecond laser in the range of 10 11 –10 13 W cm -2 power densities

Picosecond lasers (ps-lasers) have significant advantages for the generation of low charge state ions compared to nanosecond lasers because the influence of heat conductivity on a solid target is almost negligible in the case of ps-laser ablation for laser pulse durations less than 10 ps. However, there is no comprehensive data on ion yields for different elements and target irradiation conditions for laser power densities at the target surface around and below 10 13 W cm –2 , which is of interest to our study of such plasmas as a source of low charge state ions for various applications, particularly for external injection of those ions into an Electron Beam Ion Source (EBIS). We investigated ion generation from Al, Ti, Cu, Nb and Ta target elements by a ps-laser with power densities in the range of 10 11 –10 13 W cm –2 at the target surface. A ps-laser with 1.27 mJ maximum energy within an 8 ps pulse and repetition rate up to 400 Hz has been used to generate a laser-ablated plasma. Dependencies of ion current versus time, total charge of registered ions as well as ion kinetic energy distributions are characterized using a Faraday cup. Significant difference in ion current dynamics between first, second and following shots onto the same target spot was found for all five target elements. The total charge of ions registered by the Faraday cup increases linearly with increasing laser pulse energy and is almost independent of the target element and number of shots onto the same target spot for all five target elements studied. The results obtained give us a basis for specification and design of the source of low charge state ions for external injection into EBIS.

43 PARTICLE ACCELERATORS↗

Study of Ion Generation by a ps-laser for External Injection into Electron Beam Ion Source

We investigated ion generation from Al, Ti, Cu, Nb and Ta target elements by a picosecond-laser in the range of 10 11 – 10 13 W/cm 2 power densities at the target surface. A ps-laser with 1.27 mJ maximum energy within a 8 ps pulse and repetition rate up to 400 Hz has been used to generate a laser-ablated plasma. Dependencies of ion current vs time, total charge of registered ions as well as ion kinetic energy distributions are characterized using a Faraday cup. Significant difference in ion current dynamics between first, second and following shots onto the same target spot was found for all five target elements. The total charge of ions registered by the Faraday cup increase linearly with increasing laser pulse energy and are almost independent on the target element and number of shots onto the same target spot for all five target elements studied. Target craters have been examined using a commercially available microscope (Nikon Eclipse LV150) and crater cross section areas were found to be in the range of 0.0076 – 0.0172 mm 2 within the first five shots onto the same target spot for different target elements. A linear dependence of crater cross section square on laser pulse energy has been observed for the Ta target. Ion energy distributions for all target elements have a plateau or a slight peak in the energy range of 10 - 100 eV and long low-intensity energy tail up to tens of keV.

43 PARTICLE ACCELERATORS↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗