Tritium Containment Vessel Response to Thermal and Mechanical Abuse Environments for Fire Safety Assessments

This report evaluates leakage behavior from tritium containment vessels under thermal abuse and combined thermal-mechanical abuse conditions to better understand safety implications for releases occurring in a fire scenario. Surrogate gases were used for all tests in this report. Leakage through the valves from thermal pressurization was observed when heating rates >0.8°C/s were sustained to >300°C. Gas plumes were visualized from vessels that were heated above 260°C and then dropped.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic and Responsive Distributed Energy Resource Education Solutions for Building, Fire, and Safety Department Officials (Final Technical Report)

From April 2021 through March 2024, the Interstate Renewable Energy Council (IREC) led a collaborative project to develop a free online clearinghouse of educational resources about solar photovoltaics (PV), energy storage systems (ESS), electric vehicle supply equipment (EVSE), and grid-interactive efficient building (GEB) technologies. Two websites—the Clean Energy Clearinghouse and CleanEnergyTraining.org—housed over 70 educational resources. Over the course of the three-year project, 154,272 unique visitors accessed the learning materials. Learner feedback was overwhelmingly positive. Even through the end of the project, there was sustained demand for education and communication. A primary innovation of the project was to drive multiple complementary audiences to the same place. Building owners, designers, installation contractors and developers, authorities having jurisdiction (AHJs), and fire service personnel all benefit from a shared understanding of clean energy technologies, including safety and code-related requirements. When considering the impact on the target audience, the project team worked with partners and advisors to inform resource creation and delivery in such a way as to address key motivational factors of the target audience and compel each user to seek additional information on the topic and return to the Clean Energy Clearinghouse website as their central location for more information. Resources were intentionally developed to be concise—five to 15 minutes—and accessible, meaning not overly technical. Providing basic information demystified the technologies and invited the professional to explore additional learning opportunities. Awardee and partner collaboration was key to project success. IREC facilitated collaboration among the other Topic 2 awardees, Southface and New Buildings Institute (NBI). The three awardees shared relevant information gained through discovery and validation questionnaires that informed product development and reduced duplication of effort by coordinating the development of complementary, and not competing, educational resources. Inspired by this collaboration, IREC brought on additional partners even in the final year of the project. Five regional energy efficiency organizations were part of the project, which expanded the connection between efficiency and distributed energy resources. We also included resources on the Clearinghouse that were developed through other federally funded projects, such as the Buildings Energy Efficiency Frontiers & Innovation Technologies (BENEFIT) program. The website was developed with the learner in mind, and not solely the funding source. Feedback from stakeholders throughout the project, and especially in its final year, indicated the need for continued education and facilitated communication among stakeholders to further the safe and widespread adoption of clean energy.

14 SOLAR ENERGY↗

Considerations for Fire Service Response to Residential Battery Energy Storage System Incidents

Renewable energy sources (e.g., rooftop photovoltaics, wind turbines) are capable of addressing our grid-level energy challenges by reducing environmental impacts, increasing resiliency, and increasing the supply of input energy. However, renewable energy sources alone are not a complete solution. The generation of power from major renewable energy sources fluctuates with the weather, creating significant challenges in matching electrical power generation to electrical power consumption. The value of renewable power generation sources is multiplied when paired with battery energy storage systems (ESS), which can store excess power generated from renewable energy sources when it is not consumed and deliver that power later when demand exceeds base power generation. Residential ESS units are frequently installed to support renewable energy initiatives by storing energy from intermittent sources such as photovoltaic panels. Residential ESS units also offer an alternative to gas-powered generators or other backup power means. Lithium-ion batteries are the most common residential ESS technology due to their affordability and energy density. Though lithium-ion systems come with benefits, there is also a risk of thermal runaway within this technology which can result in flammable gas release, fire, and explosion. As the installations of these products increase, the frequency of response to fire incidents involving these products will increase. In response to this new and evolving hazard, UL Solutions (ULS) and UL Fire Safety Research Institute (FSRI) have partnered with the International Association of Fire Fighters (IAFF) to conduct a series of large-scale tests sponsored by the US Department of Energy to characterize the challenges for fire fighters responding to fires involving residential energy storage systems. The project focuses on developing size-up and tactical considerations to support the fire service in navigating the evolving modern fireground.

25 ENERGY STORAGE↗

A Review of Regulations, Codes, and Standards for Hydrogen Fuel Cell Electric Bus Use on Airports

This report reviews regulations, codes, and standards to be considered for FCEB operations on airports governing vehicle safety, hydrogen infrastructure, and airport operations. Overall, the review found the existing regulatory framework largely suitable for FCEB operations on airports, with only minor gaps identified pertaining to heavy-duty vehicle fueling, operation and fire safety on airport aprons, and authorization for emergency power use.

08 HYDROGEN↗

Biobased Flame Retardants Towards Sustainable Building Materials with Low Embodied Carbon

Incorporation of fire retardants in different types of products is one of the essential steps in the material production process to minimize fire risk and meet fire safety requirements. A variety of commonly used flame retardants based on halogen, mineral, and other compounds has gained popularity due to their efficient flame-retardant behaviors. However, especially in the case of halides, there are numerous toxicity related issues and environmental pollution effects that have urged the building sector to deviate from their use and focus on the development of non-toxic alternatives. Therefore, to enhance the safety of flame retardants, the synthesis of flame retardants from waste feedstocks using phosphorous chemistry with a dual flame-retardant mechanism has been established. A range of waste feedstocks that include cardanol, vanillin, and gallic acids has been converted into a series of flame retardants using a one-step approach by incorporating phosphorous moieties into their structures. The established pathways allow to develop a range of flame-retardant materials by converting waste feedstocks into phosphorous-based materials with inherent flame retardancy. The introduction of abundant aromatic structures from biobased feedstocks enables high charring capabilities in materials in which these biobased flame retardants have been incorporated, increasing their char yields which significantly enhances the flame suppressing properties of the designed materials. Studies show that inclusion of phosphoric moieties into structures allows the displacement of flame enhancing radicals, by releasing non-flammable and non-toxic gases, therefore inhibiting the spread of fire in the gas phase. The resulting biobased flame retardants have been incorporated in wood substrates, foam insulation, and hemp fibers where the results show that only 1-5% of loading of biobased flame retardant suppressed the flame completely. This study represents a novel approach for the development of flame retardants with high performance while utilizing waste feedstocks as a source for their design.

Demchuk, Zoriana [ORNL] (ORCID:0000000326292235)↗

Numerical modeling of plasma assisted deflagration to detonation transition in a microscale channel

Here, this work numerically studies the plasma assisted deflagration to detonation transition (DDT) of H 2 /O 2 mixtures in a microscale channel with detailed chemistry and transport. The results show that the DDT onset time is non-monotonically dependent on the discharge pulse number. The DDT is accelerated with small pulse numbers, whereas retarded with large ones. Two different DDT regimes, respectively at a small and large plasma discharge number, via acoustic choking of the burned gas and plasma-enhanced reactivity gradient without acoustic choking, are observed. Without plasma discharge, pronounced pressure and temperature gradients in front of the flame are generated by acoustic compression after the choking of the burned gas, triggering DDT via autoignition. With small plasma pulse numbers, the plasma-generated species enhance the ignition kinetics and lead to an increased reactivity in the boundary layer. After the choking of the burned gas, the plasma-enhanced reactivity advances the sequence of autoignition near the wall, strengthens ignition-shock wave coupling, and accelerates DDT. However, with a large discharge pulse number, a direct autoignition initiating DDT can occur without the acoustic choking of the burned gas due to the strongly accelerated reactivity and elevated temperature. In this case, DDT onset is retarded because the elevated temperature increases sonic velocity and the increased reactivity accelerates fuel oxidation in front of the flame, decelerating the formation of a leading shock and subsequent pressure buildup ahead of the flame. The present modeling reveals that no matter with or without plasma discharge, DDT is initiated by autoignition in thermal, pressure, and reactivity gradient fields via the Zel'dovich gradient mechanism. The acoustic choking of the burned gas may not be the necessary condition of DDT with strong plasma-enhanced reactivity gradient. This work provides an answer to the experimentally observed non-monotonic DDT onset time by plasma, which provides guidance to control DDT in advanced detonation engines and fire safety of hydrogen-fueled catalytic reactors in microchannels by non-equilibrium plasma discharge.

33 ADVANCED PROPULSION SYSTEMS↗

Rate constants and third-body collision efficiencies for recombination of Na with OH and O2: Implications for flame inhibition by alkali salts

Flame inhibition by alkali metals has implications for solid fuel combustion, fire safety, and a number of industrial processes. While the mechanism of inhibition is fairly well understood, details related to thermodynamic properties and rate constants are still in question. In the present work, the recombination of Na with OH (R5) and O2 (R7), respectively, was characterized theoretically, and the implications for modeling laminar premixed hydrogen flames doped with sodium species were examined. Third-body collision efficiencies and low-pressure-limit rate constants were obtained using newly fitted ab initio-based potential energy surfaces, classical trajectories, and one-dimensional master equation calculations. The results are consistent with available experimental results and aid in the present modeling study by providing rate information for bath gases and conditions that remain unexplored experimentally. Chemical kinetic modeling of relative Na and absolute H and OH profiles in H2-fueled laminar, premixed flames doped with a sodium salt shows that the most important radical removal cycle is the sequence Na + OH (+M) → NaOH (+M) (R5), NaOH + H → Na + H2O (R12), even under oxidizing conditions. A secondary cycle, Na + O2 (+M) ⇄ NaO2 (+M) (R7), NaO2 + OH → NaOH + O2 (R14), is less important due to the low thermal stability of NaO2. In most flames, reaction R7 is partially equilibrated, and reaction R14 becomes rate-limiting for the second cycle. The flame analysis supports a lower value of k14 than indicated by recent work on KO2 + OH, but more work is required to confirm this.

Jasper, Ahren W.↗

Development and experimental evaluation of new building air leakage measurement methods: measurement of interior air leaks and comparison to conventional methods

Building air leaks (both through exterior and interior surfaces) can have a significant impact on energy consumption, indoor air quality, fire safety, and moisture accumulation affecting structural durability. Blower door testing has been used to measure leaks in buildings, but commonly used testing methods do not directly measure interior leaks. In this paper, new testing methods (guarded interior test and zonal multipoint pressure testing method) are presented that directly measure these interior leaks, utilizing common blower door equipment for both single and multi-point testing. Furthermore, these new methods are compared to conventional methods in terms of the information provided, limitations and time/effort needed. In addition, building leak measurement results are analyzed to reveal a) coupling between power law model values (exponent and coefficient) for an ensemble of buildings, b) the error in using single point testing when estimating low pressure leakage, and c) how building power law models vary from low to high pressure ranges.

99 GENERAL AND MISCELLANEOUS↗

NSRC makes vital vintage films accessible to today's weapons researchers

A few years ago, archivists at the Lab’s National Security Research Center (NSRC) rediscovered 65 special reels of nitrate motion picture film among the 20,000 film reels in the NSRC’s collections. Because nitrate film stock was discontinued in 1951, they realized that the films contained footage from the Lab’s earliest days of nuclear testing. However, nitrate film is highly toxic and flammable. Confirming this hunch would have to wait until the NSRC team devised a strategy for safely preserving and digitizing the reels. Now, after many months of planning and collaboration with LANL fire safety and industrial hygiene teams, the reels – which include footage from Operation Sandstone, Operation Ivy, and the Trinity test – have been digitized by the NSRC archivist team and are accessible to today’s researchers.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Nanosecond Laser Drying in Wafer Foundries for Significant Energy Efficiency Improvement

Surface drying is a critical process in microelectronics wafer fabrication. In order to reduce and eliminate watermarks, many surface drying processes have been studied and used. Most of the wafer foundries currently use drying processes based on Isopropyl Alcohol (IPA), which causes serious safety (fire), health, environmental, and energy efficiency issues. The long-term goal of this project is to develop a fast, effective, chemical-free, and extremely energy efficient wafer drying technology that employs nanosecond laser-induced sub-surface evaporation and explosion. The objectives of this project are to 1) experimentally develop and verify the laser surface drying method, explore and identify how and to what extent various physical parameters influence the drying efficiency and effectiveness; and 2) understand and optimize the underlying thermodynamics in the proposed laser surface drying, including micro/nanoscale sub-surface superheating, evaporation, explosion, and photo/thermochemical bond breaking via atomistic modeling and experimental characterization. Toward these objectives, five tasks have been accomplished successfully, including 1) develop in-lab laser surface drying setup and study the effect of varied laser parameters, 2) use multiscale hybrid-modeling to study and understand the physics of water behavior during drying toward process optimization, 3) investigate the effect of drying conditions on the drying effectiveness, 4) develop a large-scale laser drying scanning system with automatic scanning, and 5) conduct large-scale simulation to study the effect of dopant level and develop strategies for system development toward industry deployment.

42 ENGINEERING↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Development of a 95-Year Solar Dataset for Resource Adequacy Studies

Long-term high-resolution solar data provides enhanced understanding of variability of solar generation and enhances our ability to develop strategies for a resilient and reliable electric grid under high deployment of solar energy. Therefore, it is important to develop long-term synthetic datasets that can provide multiple occurrences of various severe weather scenarios that are expected to test the limits of resource adequacy under scenarios contain various energy generation sources. Examples of such scenarios could be long periods of high temperatures when demand for electricity is high or periods where high winds could lead to a shut-down of transmission lines for long periods of time to ensure fire safety. NREL has developed the first version of such a dataset covering a 95-year period covering 2006-2100 at a 4km hourly resolution. This dataset contains all variables necessary to calculate solar generation. During development of this dataset, we focused on creating unbiased, high-resolution solar irradiance through statistical downscaling methods, using Regional Climate Model (RCM) simulations from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) as input. The National Solar Radiation Database (NSRDB) containing over 25 years of observations was used to calibrate the statistical downscaling models. This presentation will outline the primary steps in developing this dataset, including (1) regridding RCM data to a common grid at 20-km resolution, (2) correcting RCM biases with NSRDB, (3) applying temporal and spatial downscaling methods to generate high-resolution (4-km, hourly) solar and ancillary data. Additionally, we will present an evaluation of the downscaled data against the NSRDB across various zones in the CONUS. Lastly, we will present a user guide for accessing the datasets.

14 SOLAR ENERGY↗

Electric Vehicle Fire Primer for Fleet Managers

The U.S. Department of Energy's Vehicle Technologies Office provides project assistance through Clean Cities, technical expertise, and funding to help stake-holders implement alternative fuels and electric vehicles (EVs). Fleet managers considering EVs can learn about the potential for EV fires and measures to help reduce fire risk.

ADVANCED PROPULSION SYSTEMS↗

Pulse Shape Discrimination in JSNS 2

JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\overline{ν}$ μ → $\overline{ν}$ e appearance oscillations using neutrinos from muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS2 detector is located above ground, on the third floor of the building. We have achieved 94.95% ± 0.15% rejection of neutron events while keeping 92.82% ± 1.77% of signal, electron-like events using a data-driven likelihood method. This article will report the PSD technique using the full fiducial volume of the JSNS2 detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methods and recommendations for large-scale deflagration testing of battery energy storage system enclosures

UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.

Gaudet, Benjamin [UL Solutions] (ORCID:00090006419↗

Defining the State of Safety (SOS) for Lithium-Ion Batteries in EVs: A Discussion

The demand for lithium-ion batteries (LIBs) is skyrocketing, driven by the rapid growth of electric vehicles (EVs) and grid energy storage. However, current LIBs rely on flammable electrolytes, making them susceptible to thermal runaway and fires. Despite ongoing research and development efforts to enhance safety, fire incidents in EVs and energy storage systems persist. As LIB deployment increases, so too does the risk of fires. Therefore, it's crucial to define a "State of Safety" for LIBs - encompassing both operational safety and post-incident safety, such as after a car accident. This concept can help stakeholder and first responders to effectively manage LIB fire risks.

25 ENERGY STORAGE↗

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY↗

Wildfire towers drive firebrand lofting: insights from coupled fire-atmosphere model simulations

Wildfire behavior is shaped by complex fire dynamics, with firebrands playing a critical role in spot fire ignition and fire spread. While previous studies have explored firebrand generation and transport, the specific role of towers and troughs from wildland fires in the lofting of firebrands remains unquantified. This study addresses that gap by using physics-based coupled fire-atmosphere model simulations to examine how wildfire towers (updrafts) and troughs (downdrafts) influence firebrand lofting. Our results show that the majority of firebrands (78.85%) are lofted from towers, where strong updrafts drive long-range transport. In contrast, only 21.15% of firebrands are lofted within troughs, where downdrafts cause most firebrands to fall near the fireline. We also find that firebrand size significantly influences lofting behavior, with smaller particles (1 mm radius) exhibiting the strongest correlation with updraft intensity. These findings highlight the dominant role of wildfire towers in promoting long-distance firebrand dispersal—an essential factor in rapid wildfire growth and wildland-urban interface (WUI) fire risks. By quantifying the relationship between firebrand lofting and fire-induced atmospheric features, this study provides critical insights to improve spot fire modeling, support mitigation planning, and enhance firefighter and WUI community safety in spot fire-prone regions.