Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fixed frequency tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗

Detecting isolated resonance curves using fixed frequency voltage control tests

Isolated resonance curves, or isolas, are resonance branches of the harmonically forced system that exist separately from the main nonlinear forced response curve, leading to excessive vibrations. Traditional stepped or swept sine simulations and tests rely on continuation along the frequency parameter, typically resulting in a jump phenomenon along the primary resonance branch, prior to the disconnected isola. The main objective of this research is to propose an approach to identify isolated resonance curves by performing continuation along the input amplitude that initializes the response from a low-amplitude solution in the linear regime. Furthermore, this is achieved with the open-loop fixed frequency voltage control method that continues along the shaker voltage parameter and measures the so-called S-curves, which are theoretically a continuous solution branch that connect to the isola. The methodology is demonstrated on a fixture-wing-pylon assembly with a vibro-impact nonlinearity localized in a pylon subcomponent attachment. Multi-harmonic balance simulations are deployed to compute both the nonlinear forced response curves and S-curves to demonstrate the isola detection strategy on a reduced-order finite element model of the nonlinear system. Swept sine and fixed frequency voltage control tests are then conducted on the physical structure to demonstrate the isola detection experimentally, revealing the existence of the large amplitude vibrations that are undetected in the forces levels and frequencies measured with traditional frequency sweeping.

Characterization and Analytical Technique↗

QSHS: an axion dark matter resonant search apparatus

We describe a resonant cavity search apparatus for axion dark matter constructed by the quantum sensors for the hidden sector collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles, dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator (DF) and threaded by a solenoidal magnetic field, nominally 8 T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range 2.0–40 μ eV c -2 . The apparatus as currently configured is intended as a test stand for electronics over the relatively wide frequency band attainable with TM 010 the cavity mode used for axion searches. We present performance data for the resonator, DF, and magnet, and plans for the first science run.

Physics - Physics of elementary particles and fiel↗

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob↗

Real-Time FPGA Implementation For Frequency Sweep Interferometry In The LBNF Complex

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, A. Jacob [Fermilab; Unlisted]↗

Design elements and first data from a new Doppler backscattering system on the MAST-U spherical tokamak

A new Doppler backscattering (DBS) system has been installed and tested on the MAST-U spherical tokamak. It utilizes eight simultaneous fixed frequency probe beams (32.5, 35, 37.5, 40, 42.5, 45, 47.5, and 50 GHz). These frequencies provide a range of radial positions from the edge plasma to the core depending on plasma conditions. The system utilizes a combination of novel features to provide remote control of the probed density wavenumber, the launched polarization (X vs O-mode), and the angle of the launched DBS to match the magnetic field pitch angle. The range of accessible density turbulence wavenumbers (kθ) is reasonably large with normalized wavenumbers kθρs ranging from ≤0.5 to 9 (ion sound gyroradius ρs = 1 cm). This wavenumber range is relevant to a variety of instabilities believed to be important in establishing plasma transport (e.g., ion temperature gradient, trapped electron, electron temperature gradient, micro-tearing, kinetic ballooning modes). The system is specifically designed to address the requirement of density fluctuation wavevector alignment which can significantly reduce the SNR if not accounted for.

Instruments & Instrumentation↗

Maximum power point tracking for a multi-layered piezoelectric heel charger with a levered mechanism toward impact-based energy harvesting

The piezoelectric footstep energy harvester does not always work at its maximum power point when the external load is fixed, as the optimal load changes when the walking excitation alters. Thus, the harvesting efficiency is downgraded largely in real-life scenarios compared to in-lab experiments and theoretical or numerical predictions due to the mismatch between the actual load and the optimal load. To address this issue, the concept of Maximum Power Point Tracking (MPPT) is investigated in this paper and the circuit design is implemented for a multi-layered levered piezoelectric footstep energy harvester (heel charger). The proposed event-driven MPPT circuit interface with a customized buck converter aims to maximize the power gained from daily walking using the heel charger to power a fixed load, such as smart insole or shoes. The MPPT circuit design is conceptually simulated and then tested with the heel charger to further validate if it works at its maximum power point when the frequency of the input excitation alters. Results show that the extracted power from the heel charger connected to a fixed resistance load with MPPT implementation is improved up to 300% compared to the one without MPPT implementation in simulation and up to 180% in the experiment when connected to a fixed load. The difference between simulation and experimental results is due to the optimization of using voltage sources as the heel charger and the control signals (pulse width modulation) from the microcontroller in the simulation.

47 OTHER INSTRUMENTATION↗

OC6 Phase I: Investigating the underprediction of low-frequency hydrodynamic loads and responses of a floating wind turbine

Phase I of the OC6 project is focused on examining why offshore wind design tools underpredict the response (loads/motion) of the OC5-DeepCwind semisubmersible at its surge and pitch natural frequencies. Previous investigations showed that the underprediction was primarily related to nonlinear hydrodynamic loading, so two new validation campaigns were performed to separately examine the different hydrodynamic load components. In this paper, we validate a variety of tools against this new test data, focusing on the ability to accurately model the low-frequency loads on a semisubmersible floater when held fixed under wave excitation and when forced to oscillate in the surge direction. However, it is observed that models providing better load predictions in these two scenarios do not necessarily produce a more accurate motion response in a moored configuration.

17 WIND ENERGY↗

Proposal for a proton-bunch compression experiment at IOTA in the strong space-charge regime

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton-based muon source for a muon collider. This paper discusses a proton-bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring that can circulate a 2.5-MeV proton beam with varying beam parameters and lattice configurations. The study will aim to demonstrate a bunch-compression factor of at least 2 in the IOTA ring while examining the impact of intense space-charge effects on the compression process.

43 PARTICLE ACCELERATORS↗

IOTA experiment for proton pulse compression at extreme space-charge

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton driver for a muon collider. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring dedicated to beam physics R&D that can circulate a 2.5-MeV proton beam with extreme space-charge. Using ImpactX and its 3D space-charge solver, simulations indicate that bunch length can be rapidly reduced by a factor of at least two, without appreciable degradation in transverse beam quality, even under strong space-charge conditions. However, longitudinal defocusing presents a large effect in short-pulsed proton beams, and the optimization of bunch compression under such conditions is discussed.

Simons, Benjamin [Northern Illinois U.; Fermilab]↗

Proposal for a Proton-Bunch Compression Experiment at IOTA in the Strong Space-Charge Regime

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton-based muon source for a muon collider. This paper discusses a proton-bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring that can circulate a 2.5-MeV proton beam with varying beam parameters and lattice configurations. The study will aim to demonstrate a bunch-compression factor of at least 2 in the IOTA ring while examining the impact of intense space-charge effects on the compression process.

43 PARTICLE ACCELERATORS↗

Using the Monte Carlo Method to Evaluate the Reliability of Screening Multifamily Housing for Radon

When screening for radon in a multifamily housing complex using a fixed sample density (e.g., testing 1 in 10 (10%) or 1 in 4 units (25%)), the statistical confidence is dependent upon the assumed elevated radon frequency. For example, testing 25% of units in a complex estimated to have eight units with elevated radon levels will provide 90% confidence. However, if it is assumed that, in the same complex, there are only three units with elevated radon levels, the confidence drops to around 58% for the same sample density. Furthermore, in the previous example, if elevated radon levels are not found during the screening, all that can be stated is that the screening provides 90% confidence that there are no more than seven units in the complex with elevated radon levels. To more fully illustrate this uncertainty, ten separate multifamily housing radon data sets with 1 to 10 units with radon levels ≥4 pCi/L (Table 1) were selected for analysis using the Monte Carlo statistical method. Unlike other mathematically based statistical approaches, the Monte Carlo statistical method relies on repeated analysis of randomly selected data. from a 100% sampled complex at various sample densities. Success for each simulation is defined as finding at least one unit with elevated radon levels. In this statistical method, confidence in the overarching conclusion can be greatly enhanced by repeating the simulated screening hundreds or even thousands of times. For this study, each of the ten data sets was simulated 1,000 times. For each simulation, the data set was randomized three times before the fixed percentage of data was selected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

IOTA Experiment for Proton Pulse Compression at Extreme Space-Charge

The longitudinal compression of high-intensity, space-charge-dominated proton bunches is a critical requirement for future proton-driven muon colliders. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to investigate optimal radio-frequency (RF) cavity parameters and lattice configurations. IOTA is a compact, fixed-energy storage ring dedicated to beam physics Research and Development and capable of circulating a 2.5 MeV proton beam under extreme space-charge conditions. Using the ImpactX code with its 3D space-charge solver, simulations indicate that the bunch length can be rapidly reduced by at least a factor of two without appreciable degradation of transverse beam quality--even in the strong space-charge regime. However, longitudinal defocusing due to the space-charge remains a significant challenge in short-pulsed intense proton bunches, and the optimization of compression under these conditions is discussed.

Simons, B. D. [Northern Illinois U.]↗