Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flat mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Overcoming energy limitation in post-compression of picosecond pulses by free beam propagation in air and temporal pulse splitting and recombining

Cryogenically cooled diode-pumped Yb:YAG has been demonstrated to efficiently generate pulses of >1 J energy and several picoseconds duration at a kilohertz repetition rate. Pulse broadening and post-compression techniques capable of operating at these high pulse energies will expand the use of these lasers in applications requiring shorter pulses. Towards this goal, we demonstrate the post-compression of 5.5 ps pulses with energy in the 0.1 J range by spectral broadening of self-collimated large area beams in air. In proof-of-principle experiments, pulses of 65 mJ energy from a cryogenically cooled Yb:YAG laser were compressed to 1.1 ps after 65 m propagation in a compact setup in which the beam was folded using flat mirrors. Further energy scaling was demonstrated by combining this spectral broadening technique with temporal pulse splitting and recombining. 120 mJ pulses were split into two pulses and coherently recombined with 85% efficiency after 50 m of propagation in air to yield 1.4 ps pulses.

High Energy Laser↗

Spinning Hall Probe magnetic compass

In a large range of physics and space experiments, the direction of the magnetic field needs to be determined with an accuracy on the level of one milli radian or better. We have proposed a new type of magnetic compass - a rotation-based one, which provides an alternating signal from the Hall probe proportional to the value of the magnetic field transverse to the axis of rotation. The spinning Hall probe device has been realized. Alignment of the spinning axis for a minimum (zero) value of the signal allows us to find the direction of the magnetic field. The device does not require calibration and is free of any drift problems. The measurement of the rotation axis direction was accomplished by means of a laser and a flat mirror attached to the rotor. The constructed prototype achieved an accuracy for the magnetic field direction in the experiment with the polarized He-3 target on the level of one milli radian.

Wojtsekhowski, Bogdan↗

Chiral flat-band optical cavity with atomically thin mirrors

A fundamental requirement for photonic technologies is the ability to control the confinement and propagation of light. Widely used platforms include two-dimensional (2D) optical microcavities in which electromagnetic waves are confined in either metallic or distributed Bragg reflectors. Recently, transition metal dichalcogenides hosting tightly bound excitons with high optical quality have emerged as promising atomically thin mirrors. In this work, we propose and experimentally demonstrate a subwavelength 2D nanocavity using two atomically thin mirrors with degenerate resonances. Angle-resolved measurements show a flat band, which sets this system apart from conventional photonic cavities. We demonstrate how the excitonic nature of the mirrors enables the formation of chiral and tunable optical modes upon the application of an external magnetic field. Moreover, we show the electrical tunability of the confined mode. Our work demonstrates a mechanism for confining light with high-quality excitonic materials, opening perspectives for spin-photon interfaces, and chiral cavity electrodynamics.

36 MATERIALS SCIENCE↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Optimization of VISAR Mirrors for NIF Targets

The velocity interferometer system for any reflector (VISAR) is a key diagnostic at the National Ignition Facility that is used for measuring propagation and velocities of shocks through a sample for several high energy density campaigns. To support simultaneous measurements with VISAR and other diagnostics, optical mirrors are used to divert the VISAR signal off axis from the primary diagnostic line of sight, which can then be used for other measurements. Here, in this study, we describe our work on investigating issues with these mirrors to support complex new target geometries and signal variance due to system aging and more demanding polling rates. This paper also describes the key mitigation efforts performed to improve both the flatness and reflectivity of these commonly used mirrors.

National Ignition Facility↗

Particle production by a relativistic semitransparent mirror of finite size and thickness

Production of massless scalar particles by a relativistic semitransparent mirror of finite transverse size and longitudinal thickness in (1+3)D flat spacetime is studied. The derived particle spectrum formula is applied to two specific trajectories. One is the gravitational collapse trajectory invoked in (1+1)D perfectly reflecting moving mirror literature to mimic Hawking radiation, and the other is the plasma mirror trajectory proposed to be realizable in future experiments. It is found that the finiteness of the transverse size leads to diffraction, while the nontrivial thickness amplifies the production rate. We also estimated the particle yield as ~ 3000 in a 20-day data acquisition based on the parameters invoked in the proposed AnaBHEL experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lattice regularization of reduced Kähler-Dirac fermions and connections to chiral fermions

We show how a path integral for reduced Kähler-Dirac fermions suffers from a phase ambiguity associated with the fermion measure that is an analog of the measure problem seen for chiral fermions. However, unlike the case of chiral symmetry, a doubler free lattice action exists which is invariant under the corresponding onsite symmetry. This allows for a clear diagnosis and solution to the problem using mirror fermions resulting in a unique gauge invariant measure. By introducing an appropriate set of Yukawa interactions which are consistent with ’t Hooft anomaly cancellation we conjecture the mirrors can be decoupled from low energy physics. Moreover, the minimal such Kähler-Dirac mirror model yields a light sector which corresponds, in the flat space continuum limit, to the Pati-Salam GUT model.

Physics↗

Two-step retrace error calibration removing tilt ambiguity in coherence scanning interferometry

In interferometry measurement, the retrace error often limits its high-precision metrology applications. Retrace error calibration with tilted flats can give a relation between the retrace error and the introduced tilt angles, but there is still an ambiguity between the introduced tilt angles and the tilt terms in the created retrace error. Here, we propose a novel, to the best of our knowledge, two-step calibration method to resolve this tilt ambiguity. It involves additional measurements of spherical mirror(s) with known curvature(s). The experiment shows that the curvature deviation due to the tilt ambiguity can be significantly reduced after applying the proposed method.

36 MATERIALS SCIENCE↗

Low-Cost Heliostat for High-Flux Small-Area Receivers (Final Technical Report)

This project analyzed a two-stage heliostat concept consisting of a tracking stage and a concentrating stage. The tracking stage uses mirrors mounted on a common drive that move to track the sun. The concentrating stage consists of stationary mirrors that each have a unique angle to direct rays towards a small-area, high-flux, point-focused receiver. By splitting the collection and concentrating process into two stages, multiple small, inexpensive mirrors can share a structure and be controlled by a single drive in the tracking stage. The project effort developed modeling techniques that were specifically relevant to this two-stage heliostat concept. Both field-level and unit-level models were developed. The field-level model does not explicitly consider unit-level losses which are predicted by the unit-level model and then integrated into the field-level model through a correlation referred to as an efficiency modifier. This approach is referred to as the two-model approach; the development and demonstration of this two-model approach for a multi-stage heliostat technology is a key outcome of this work. The field-level model is used to design a field that hits a specific design day power given a set of heliostat design parameters. An oversized field is simulated and then heliostat units are removed based on their annual energy production in order to generate the highest performing field. The field reduction procedure fits a smooth curve fit to annual energy production as a function of position in the field which has the effect of reducing the noise that is otherwise caused by the Monte Carlo ray tracing technique. This approach is referred to as the annual energy fit method and substantially reduces computational run time for a given field level modeling accuracy. The annual energy fit approach enables the selection of a properly sized, high-performing field using orders of magnitude fewer rays than would otherwise be possible and the development of this approach is a second key outcome of this work. These models are used within a genetic optimization algorithm in order to optimize the geometric parameters associated with a heliostat in order to achieve the lowest cost per unit of collected design day power. The cost modeling that underlies the optimization is a simple, scaling type analysis backed up by a much more detailed Design for Manufacture and Assembly (DFMA) analysis. Although the figure of merit used for optimization was not cost per mirror area, this metric is reasonable to use as a means of comparison. The optimally designed 500 kW design has a tracking mirror specific cost of $181.85/m 2 , which is significantly larger than the target value and also larger than the current state of the art. The cost of the torque-tube type linkages contributed substantially to the overall cost. Based on this observation, potentially attractive alternative design configuration utilizing a capstan type actuation system should be investigated. Finally, NREL compared the performance of the two-stage heliostat to the performance of a focused and different sized flat conventional heliostats and showed that, as expected, additional losses versus the convention heliostat caused by a worse cosine efficiency, two stages of reflection, and interstage interactions. The two-stage heliostat requires around 75% more reflective area than a flat 1x1 meter conventional heliostat (similar to a focused heliostat) and 40% more than a flat 2x2 meter conventional heliostat.

14 SOLAR ENERGY↗

Replenishing liquid sheet targets to enable high-intensity high-repetition-rate laser–plasma interactions for ion-beam technology

We report on the development of a robust microfluidic nozzle capable of generating replenishing liquid sheet targets with sub-micron thickness at up to kHz repetition rates, a λ/20 surface flatness over areas of at least 100 μm 2 , and in-vacuum dimensions of 6 × 1.5 mm 2 . The platform was evaluated for stability under hundreds of 4.3 J laser shots at 0.5 Hz and 6 × 10 20 W/cm 2 peak intensity, delivered in burst mode, totaling 2.9 kJ on the target. The key metrics of the platform, including sheet characteristics, nozzle aperture morphology, and proton spectra, showed no measurable degradation in the performance of the liquid sheet platform following this experiment. Beyond its application to ion beam technology, we outline a pathway to further develop the capabilities of the platform into a high-repetition-rate plasma mirror.

depth profiling techniques↗

Convolutional double copy in (anti) de Sitter space

The double copy is a remarkable relationship between gauge theory and gravity that has been explored in a number of contexts, most notably scattering amplitudes and classical solutions. The convolutional double copy provides a straightforward method to bridge the two theories via a precise map for the fields and symmetries at the linearised level. This method has been thoroughly investigated in flat space, offering a comprehensive dictionary both with and without fixing the gauge degrees of freedom. In this paper, we extend this to curved space with an (anti) de Sitter background metric. We work in the temporal gauge, and employ a modified convolution that involves the Mellin transformation in the time direction. As an example, we show that the point-like charge in gauge theory double copies to the (dS-) Schwarzschild black hole solution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗