Search NASA⌕ Search

SEARCH · Search NASA

Results for “GIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Effects-Based Monitoring of Geomagnetically-Induced Current Using a Convolutional Neural Network

Geomagnetically-induced current (GIC) due to space weather can flow in the power grid causing undesirable effects such as transformer overheating, misoperation of protection devices, and potential blackouts. It is therefore important to monitor GIC in the power grid to improve online situational awareness and decision-making of system operators during a geomagnetic disturbance. To avoid the costly installation of GIC monitors at transformers’ neutrals, it is desirable to find correlations between GIC and already-monitored parameters. Hence, this work proposed the use of a convolutional neural network (CNN) to compute GIC amplitudes from learned patterns in the time-series data of transformer even harmonic currents. Using an electromagnetic transient program, GIC injection simulations were performed for a modeled Dominion Energy Virginia (DEV) substation with two 504 MVA, 500/230 kV transformers. Data collected from these offline simulations were used to train the CNN to provide online GIC monitoring. Testing the CNN performance involved using real GIC measurements from published literature and from a physical GIC monitor in the DEV area. Finally, the results showed that the proposed method was able to provide GIC readings with a root mean squared error of 1.56 A/phase (equivalent to an average accuracy of 94%) for these real GIC waveforms.

42 ENGINEERING↗

Impact of Geomagnetic Induced Current Neutral Blocking Devices on Distance Relays in Sub-transmission Networks with IBR

Geomagnetically induced currents (GICs) can flow through transmission lines during geomagnetic disturbances, such as solar flares or coronal mass ejections. These currents can cause problems like transformer saturation and equipment damage. The most common method of mitigating GICs involves installing GIC neutral blocking devices (NBDs) in transformer neutrals. However, the wide application of capacitive GIC blocking devices may have unintended adverse effects on other devices, such as distance protection relays. As the number of inverter-based resources being connected to the transmission and sub-transmission systems increases, the likelihood of a sub-transmission line protected by a distance relay connected to a transformer with NBDs is increasing. Therefore, distance relays fed by IBRs and transmission lines with GIC-NBDs must be studied. This paper studies the effect of GIC-NBDs on a 69kV sub-transmission line of various lengths fed by a 25 MVA IBR and synchronous source. This work focused on the behavior of the GIC-NBDs using the measured apparent phase-to-ground and phase-to-phase impedance calculated by the relay and the source impedance ratio (SIR) during various electrical faults.

Patel, Trupal R [Sandia National Laboratories (SNL↗

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays↗

Solvent-Mediated, Reversible Ternary Graphite Intercalation Compounds for Extreme-Condition Li-Ion Batteries

Traditional Li-ion intercalation chemistry into graphite anode exclusively utilizes the co-intercalation-free or co-intercalation mechanism. The latter mechanism is based on ternary graphite intercalation compounds (t-GICs), where glyme solvents were explored and proved to deliver unsatisfied cyclability in LIBs. Herein, we report a novel intercalation mechanism, that is, in-situ synthesis of t-THF-GICs in the tetrahydrofuran (THF) electrolyte via a spontaneous, controllable reaction between binary-GICs and free THF molecules during initial graphite lithiation. The spontaneous transformation from b-GIC to t-GIC, which is different from conventional co-intercalation chemistry, is characterized and quantified via operando synchrotron X-ray and electrochemical analyses. The resulting t-GIC chemistry obviates the necessity for complete Li-ion desolvation, facilitating rapid kinetics and synchronous charge/discharge of graphite particles even under high current densities. Consequently, the graphite anode demonstrates unprecedented fast charging (1 min), dendrite-free low-temperature performance, and ultralong lifetimes exceeding 10,000 cycles. Full cells coupled with layered cathode, display remarkable cycling stability upon a 15-min charging and excellent rate capability even at -40 °C. Furthermore, our chemical strategies are shown to extend beyond Li-ion batteries to encompass Na-ion and K-ion batteries, underscoring their broad applicability. Our work contributes to the advancement of graphite intercalation chemistry and presents a low-cost, adaptable approach to achieving fast-charging and low-temperature batteries.

25 ENERGY STORAGE↗

Computational Analysis and Optimized Modeling of Geomagnetically Induced Currents in Power Transformers

In this project we aim to better understand the effect of geomagnetically induced currents (GIC) on power transformers. Expanding upon our previous work focused on producing a methodology for accuracy-enhanced computation of GIC signatures (i.e., time-domain current magnitude variation for the event duration) from a combination of physics-based and data-driven computational tools, we propose the use of these GIC signatures as inputs for a physically-detailed and optimized model of the power transformer to investigate how GIC determination and transformer modeling influence the evaluation of GIC effects on the transformer operation, as well as in its interaction with the power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

Mitigating the Impacts of Uncertain Geomagnetic Disturbances on Electric Grids: A Distributionally Robust Optimization Approach

Severe geomagnetic disturbances (GMDs) increase the magnitude of the electric field on the Earth’s surface (E-field) and drive geomagnetically-induced currents (GICs) along the transmission lines in electric grids. These additional currents can pose severe risks, such as current distortions, transformer saturation and increased reactive power losses, each of which can lead to system unreliability. Today several mitigation actions (e.g., changing grid topology) exist that can reduce the harmful GIC effects on the grids. Making such decisions can be challenging, however, because the magnitude and direction of the E-field are uncertain and non-stationary. In this paper, we model uncertain E-fields using the distributionally robust optimization (DRO) approach that determines optimal transmission grid operations such that the worst-case expectation of the system cost is minimized. We also capture the effect of GICs on the nonlinear AC power flow equations. For solution approaches, we develop an accelerated column-and-constraint generation (CCG) algorithm by exploiting a special structure of the support set of uncertain parameters representing the E-field. Extensive numerical experiments based on “epri-21” and “uiuc-150” systems, designed for GMD studies, demonstrate (i) the computational performance of the accelerated CCG algorithm, (ii) the superior performance of distributionally robust grid operations that satisfy nonlinear, nonconvex AC power flow equations and GIC constraints, in comparison with standard stochastic programming-based methods during the out-of-sample testing.

42 ENGINEERING↗

Physics-informed heterogeneous graph neural networks for DC blocker placement

The threat of geomagnetic disturbances (GMDs) to the reliable operation of the bulk energy system has spurred the development of effective strategies for mitigating their impacts. One such approach involves placing transformer neutral blocking devices, which interrupt the path of geomagnetically induced currents (GICs) to limit their impact. The high cost of these devices and the sparsity of transformers that experience high GICs during GMD events, however, calls for a sparse placement strategy that involves high computational cost. To address this challenge, we developed a physics-informed heterogeneous graph neural network (PIHGNN) for solving the graph-based dc-blocker placement problem. Our approach combines a heterogeneous graph neural network (HGNN) with a physics-informed neural network (PINN) to capture the diverse types of nodes and edges in ac/dc networks and incorporates the physical laws of the power grid. We train the PIHGNN model using a surrogate power flow model and validate it using case studies. Results demonstrate that PIHGNN can effectively and efficiently support the deployment of GIC dc-current blockers, ensuring the continued supply of electricity to meet societal demands. Furthermore, our approach has the potential to contribute to the development of more reliable and resilient power grids capable of withstanding the growing threat that GMDs pose.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DFT simulation of the X-ray diffraction pattern of aluminum-ion-intercalated graphite used as the cathode material of the aluminum-ion battery

Many breakthroughs have been achieved in rechargeable aluminum-ion battery technologies in recent years. Most recently, operando X-ray diffraction (XRD) combined with density functional theory (DFT) calculations was reported to study the chloroaluminate anion (AlCl 4 -)-intercalated graphite cathode of the battery. However, there are quite a few discrepancies between the measured and simulated XRD patterns. This work is focused on the simulation of XRD patterns of graphite intercalation compounds (GICs) with DFT calculations. Our results reveal that both the geometry of AlCl 4 - in graphite and the gallery height of GICs are dependent on the intercalant density. At low intercalant density, the gallery height keeps constant, but at high intercalant densities, the gallery height is linearly related to the intercalant density. Our simulated XRD patterns are highly consistent with the measured operando XRD patterns. Not only do the angles of the peaks match very well, but also the relative intensities and the corresponding electrode capacities show reasonable agreement with the experimental results. The DFT simulation of the XRD pattern provides significant information on the stage index and the charge capacity of the GIC electrode.

25 ENERGY STORAGE↗

Graphite Intercalation Compounds Derived by Green Chemistry as Oxygen Reduction Reaction Catalysts

Precious group metal (PGM) catalysts such as Pt supported on carbon supports are expensive catalysts utilized for the oxygen reduction reaction (ORR) due to their unmatched catalytic activity and durability. As an alternative, PGM-free ORR electrocatalysts that offer respectable catalytic activity are being pursued. Most of the notable PGM-free catalysts are obtained either from a bottom-up approach synthesis utilizing nitrogen-rich polymers as building blocks, or from a top down approach, where nitrogen and metal moieties are incorporated to carbonaceous matrixes. The systematic understanding of the origin of catalytic activity for either case is speculative and currently employed synthesis techniques typically generate large amounts of hazardous waste such as acids, oxidizing agents, and solvents. Herein, for the first time, we investigate the catalytic activity of graphite-based materials obtained via intercalation strategies that minimally perturb the graphitic backbone. Here, our outlined approaches demonstrate initial efforts to not only elucidate the role of each element but also significantly reduce the use of hazardous chemicals, which remains a pressing challenge. Graphite intercalation compounds (GIC) were obtained using fewer steps and solvent-free processes. X-ray diffraction and Raman results confirm the successful intercalation of FeCl 3 between graphite layers. Electrochemical data shows that the ORR performance of FeCl 3 -intercalated GIC displays slight improvement where the onset potential reaches 0.77 V vs RHE in alkaline environments. However, expansion of the graphite and solvent-free incorporation of iron and nitrogen moieties resulted in a significant increase in ORR activity with onset potential to 0.89 V vs RHE, a maximum half-wave of 0.72 V vs RHE, and a limiting current of about 2.5 mA cm –2 . We anticipate that the use of near solvent-free processes that result in a high yield of catalysts along with the fundamental insight into the origin of electrochemical activity will tremendously impact the methodologies for developing next-generation ORR catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic signatures of Lorentzian dynamics and charge fluctuations in lithiated graphite structures

Lithium graphite intercalation compounds (Li-GICs) are essential materials for modern day portable electronics and obtaining insights into their atomic structure and thermodynamics is of fundamental interest. Here we explore the electronic and atomic states of Li-GICs at varying degrees of Lithium loading (i.e., “staging”) by means of ab-initio molecular dynamics simulations and simulated X-ray adsorption spectroscopy (XAS). We analyze the atomic correlation functions and shows that the enhancements of the Li-ion entropy with increased staging result from Lorentzian lithium-ion dynamics and charge fluctuations, which activate low-energy phonon modes. The associated electronic signatures are modulations of the unoccupied π*/σ* orbital energy levels and unambiguous fingerprints in Carbon K-edge XAS spectra. Thus, we extend the canonical view of XAS, establishing that these “static” measurements in fact encode the signature of the thermodynamic response and relaxation dynamics of the system. This causal link between atomic structure, spectroscopy, thermodynamics, and information theory can be generally exploited to better understand stability in solid-state electrochemical systems.

25 ENERGY STORAGE↗

Interlayer fusion bonding of semi-crystalline polymer composites in extrusion deposition additive manufacturing

This work focuses on the evolution of interlayer fracture toughness properties of fiber-reinforced, semi-crystalline polymers in the extrusion deposition additive manufacturing (EDAM) process. Further, this work bridges the gap between the additive process conditions (time-temperature history) and the effective layer-to-layer fracture properties developed within a printed component. This is the first step to predict delamination that can occur during printing, during cooling to room temperature after printing, and during service performance of an additively manufactured geometry. A phenomenological model is developed for fusion bonding of semi-crystalline polymer matrix composites by coupling the interdiffusion of polymer chains with the evolution of polymer crystallinity. While the interdiffusion is captured by reptation theory of polymer dynamics, the evolution of crystallinity is modeled by phenomenological crystallization kinetics and crystal melting dynamics. Further, a methodology is developed to determine the critical strain energy release rate, G IC of the interlayer interface and experiments are conducted utilizing the double cantilever beam fracture test geometry. In conclusion, predictions of GIC as a function of thermal history are compared with experiments.

36 MATERIALS SCIENCE↗

An Integrated Assessment of a G3 GMD Event on Large-Scale Power Grids: From Magnetometer Data to Geomagnetically Induced Current Analysis

Solar activities can cause geomagnetic disturbances (GMDs) that give rise to geomagnetically induced currents (GICs) which may compromise the reliability of the power system. In order to build more reliable models representing GMD interactions with the power grid, the power system’s detailed electrical model must be considered along with fluctuations in the earth’s magnetic and induced surface electric fields. Here, this study investigates the impact of incorporating spatially varying magnetic fields into surface electric field models on GMD risk metrics. A spatially independent magnetic field model and a spatially varying model are compared through simulations. To perform this analysis, the earth’s magnetic field disturbances are transformed into surface electric fields using respective one-dimensional earth conductivity models. Then, the modeling impact of these electric fields is studied using a 2,000-bus grid for Texas and a 25,000-bus grid for the northeast and mid- Atlantic regions of the United States. Simulation results reveal that the inclusion of spatially varying magnetic fields results in considerable differences in GMD risk metrics, highlighting the importance of accounting for spatial variability when assessing GMD risks in the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring Localized Geomagnetic Disturbances in Global MHD: Physics and Numerics

One of the prominent effects of space weather is the formation of rapid geomagnetic field variations on Earth's surface driven by the magnetosphere-ionosphere system. These geomagnetic disturbances (GMDs) cause geomagnetically induced currents to run through ground conducting systems. In particular, localized GMDs (LGMDs) can be high amplitude and can have an effect on scale sizes less than 100 km, making them hazardous to power grids and difficult to predict. In this study, we examine the ability of the Space Weather Modeling Framework (SWMF) to reproduce LGMDs in the 7 September 2017 event using both existing and new metrics to quantify the success of the model against observation. We show that the high-resolution SWMF can reproduce LGMDs driven by ionospheric sources, but struggles to reproduce LGMDs driven by substorm effects. We calculate the global maxima of the magnetic fluctuations to show instances when the SWMF captures LGMDs at the correct times but not the correct locations. To remedy these shortcomings we suggest model developments that will directly impact the ability of the SWMF to reproduce LGMDs, most importantly updating the ionospheric conductance calculation from empirical to physics-based.

79 ASTRONOMY AND ASTROPHYSICS↗