Search NASA⌕ Search

SEARCH · Search NASA

Results for “Geothermal Heating and Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

District Geothermal Heating + Cooling Deployment in a CT Environmental Justice Community

The report marks the team’s completion of all required tasks and milestones. Work completed for Task 1 (Technical and Economic Feasibility Assessment & Procurement Drafting) included development of analysis and design model; completion of technical, economic, and environmental assessments; and technical outreach and coalition design. Components for Task 2 (Outreach & Community Engagement) involved broad outreach and community-engagement efforts (including stakeholder meetings and a webinar as well as development of a formal engagement plan) and development of a web page and a case study. For Task 3 (Workforce Transition, Development, & Training Plan), the team undertook a formal statewide geothermal workforce needs assessment, developed corresponding recommendations for both the state as a whole and the Wallingford project, and held several workshops. For Task 4 (Project Management & Data Sharing), the team drafted a data-sharing plan.

15 GEOTHERMAL ENERGY↗

An Online Tool for Preliminary Design and Techno-Economic Analysis of District Geothermal Heating and Cooling Systems

District geothermal heating and cooling systems (DGHCS) have significant benefits for reducing energy consumption as well as building- and grid-level peak electric demand. Currently, no publicly available tools are available to effectively design and conduct techno-economic analysis of DGHCS. GeoWISE was originally developed for preliminary design and techno-economic analysis of geothermal heating and cooling systems in an individual commercial or residential building. This paper introduces recent upgrades of GeoWISE that allow users to design and conduct techno-economic analysis of DGHCS. Several new features are implemented in GeoWISE to allow selection and specification of multiple new or existing buildings. A database of information for over 125 million existing U.S. buildings was used in GeoWISE that allows users easily locate existing buildings of interest based on street addresses, and optionally edit information of the buildings (e.g., footprint, vintage, principal functions, number of floors, window-to-wall ratio). Unique energy simulation models of the selected buildings are then automatically created using the Automatic Building Energy Modeling (AutoBEM) and EnergyPlus simulations are performed to predict thermal loads of the buildings. A simplified DGHCS is then designed and simulated to predict its energy use. A central borehole heat exchanger (BHE) of the DGHCS is sized using the RowWise algorithm of GHEDesigner to meet the thermal loads within user-specified land areas for installing BHE. The upgraded GeoWISE reports the needed capacity of heating and cooling equipment in each building, design of the central BHE, energy consumption reduction, and energy cost saving resulting from using DGHCS compared with conventional HVAC systems. A case study is showcased using the upgraded GeoWISE to design and conduct techno-economic analysis of a simplified DGHCS.

Prem Anand Jayaprabha, Jyothis Anand [ORNL] (ORCID↗

Identifying Regions Favorable for Geothermal Heating and Cooling Storage

Space heating and cooling represents the single largest category of in building energy use for U.S. residential and commercial buildings, with heating representing 61% of residential and 46% commercial energy consumption. Building heating technologies are dominated by natural gas technologies, and are an important opportunity for building electrification to enable a transition to a low CO 2 energy system. FLXenabler study is a joint analysis effort among multiple analysis teams at NREL and focused on examining the role of geothermal heating and cooling (GHC) system with thermal energy storage (TES) providing flexibility. Utilizing information from ResStock the amount of energy consumption associated with heating and cooling by state was calculated. We applied adjusted load shapes to estimate the a maximum grid savings potential of using TES to address building space conditioning. Normalizing grid, fuel, and emissions impacts locations with higher favorability for further study in FLXenabler were identified.

15 GEOTHERMAL ENERGY↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma

This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Assessing Low-Temperature Geothermal Play Types: Relevant Data and Play Fairway Analysis Methods

The U.S. Department of Energy (DOE) Geothermal Technologies Office (GTO) is supporting the Geothermal Heating and Cooling Geospatial Datasets and Analysis project conducted by the National Renewable Energy Laboratory (NREL) as part of a broader effort to demonstrate the multi-faceted value of integrating geothermal power and geothermal heating and cooling (GHC) technologies into national decarbonization plans and community energy plans. Currently, there is a need to establish baseline low-temperature geothermal resource datasets and evaluate methods for deploying these technologies to provide the basis for supporting private sector investment. This project is focused on collecting baseline datasets, updating conceptual models, and creating Play Fairway Analysis (PFA) workflows for low-temperature (<150 degrees Celsius) geothermal resources of different geothermal play types (i.e., sedimentary basin, orogenic belts, and radiogenic geothermal play types) that could be used for geothermal heating and cooling (GHC), combined heat and power (CHP), and other geothermal direct uses (GDU) applications. Low-temperature geothermal resources are defined as reservoirs - natural or engineered - with temperatures <150 degrees Celsius. While the focus in the NREL effort is on GHC, resources at the upper end of this temperature range can also be used for small-scale power generation. This project does not include Ground Source Heat Pumps (GSHPs) technologies because they can be effectively developed almost anywhere. Low-temperature geothermal resources have not been studied as extensively as higher- to medium-temperature geothermal resources, but there is recent interest in improving understanding of these types of resources with an uptick of interest in geothermal technologies for decarbonizing heating and cooling systems. In addition, Enhanced Geothermal Systems (EGS) and other emerging technologies for exploiting petrothermal resources have opened the possibility of utilizing deep sedimentary basin systems, where porous media provide permeability and high temperatures can be reached at great depths. This project takes the approach of classifying low- temperature geothermal resources by geothermal play type (GPT). We defined and characterized three major classes of low-temperature GPT: sedimentary basins, orogenic systems, and radiogenic systems. We develop methodologies for evaluating and analyzing the potential for these resources building off the PFA approach to de-risking geothermal exploration and characterization. The proposed PFA approach for low-temperature geothermal resources includes: 1) identifying relevant data (e.g., datasets such bottom-hole temperatures from oil and gas wells, heat flow data, Quaternary faults and stress field data, geophysical data, etc.); 2) grouping and weighting of relevant datasets into PFA criteria (e.g., geological, risk, and economic criteria); 3) uncertainty quantification; 4) developing favorability or common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection; and 5) estimating electric power generation and heating potential at those locations using the GeoRePORT Resource Size Assessment Tool (RSAT). This project should facilitate future deployment of GHC, CHP, and GDU by providing data, tools, and a workflow applicable to low-temperature geothermal resources. Increased deployment of GHC and GDU will help achieve national and local decarbonization goals.

15 GEOTHERMAL ENERGY↗

Energy efficient data center liquid cooling with geothermal enhancement

A data center cooling system is operated in a first mode, has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and has an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second, different, mode; and, responsive thereto, the data center cooling system is switched to the second mode. The second mode includes at least another of ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion.

Chainer, Timothy J.↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Pilgrim Hot Springs: GEOPHIRES Inputs and Outputs for Direct-Use Geothermal District Heating and Cooling

This dataset includes files for a techno-economic analysis conducted using the GEOPHIRES simulator to examine the feasibility of expanding a larger district heating site in a remote location: Pilgrim Hot Springs, Alaska. Files included here are GEOPHIRES inputs and outputs for five different scenarios with varying demand, cycle, and system design characteristics to analyze. Also included is the link to the GEOPHIRES GitHub, as well as a link to the dataset that contains the energy modelling used to determine the heating demand for the district. For a list of the differences between scenarios, see the included "Input Overview.txt" file. Fields included in the input files are: subsurface technical parameters, surface technical parameters, financial parameters, capital and O&M parameters, as well as simulation parameters. The output files are case reports that summarize all equipment, reservoir characteristics, costs, and heating profiles.

15 GEOTHERMAL ENERGY↗

Low-Temperature Geothermal Geospatial Datasets: An Example from Alaska

This project is a component of a broader effort focused on geothermal heating and cooling (GHC) with the aim of illustrating the numerous benefits of incorporating GHC and geothermal heat exchange (GHX) into community energy planning and national decarbonization strategies. To better assist private sector investment, it is currently necessary to define and assess the potential of low-temperature geothermal resources. For shallow GHC/GHX fields, there is no formal compilation of subsurface characteristics shared among industry practitioners that can improve system design and operations. Alaska is specifically noted in this work, because heretofore, it has not received a similar focus in geothermal potential evaluations as the contiguous United States. The methodology consists of leveraging relevant data to generate a baseline geospatial dataset of low-temperature resources (less than 150 degrees C) to compare and analyze information accessible to anyone trying to understand the potential of GHC/GHX and small-scale low-temperature geothermal power in Alaska (e.g., energy modelers, communities, planners, and policymakers). Importantly, this project identifies data related to (1) the evaluation of GHC/GHX in the shallow subsurface, and (2) the evaluation of low-temperature geothermal resource availability. Additionally, data is being compiled to assess repurposing of oil and gas wells to contribute co-produced fluids toward the geothermal direct use and heating and cooling resource potential. In this work we identified new data from three different datasets of isolated geothermal systems in Alaska and bottom-hole temperature data from oil and gas wells that can be leveraged for evaluation of low-temperature geothermal resource potential. The goal of this project is to facilitate future deployment of GHC/GHX analysis and community-led programs and update the low-temperature geothermal resources assessment of Alaska. A better understanding of shallow potential for GHX will improve design and operations of highly efficient GHC systems. The deployment and impact that can be achieved for low-temperature geothermal resources will contribute to decarbonization goals and facilitate widespread electrification by shaving and shifting grid loads.

15 GEOTHERMAL ENERGY↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

Assessing Low-Temperature Geothermal Play Types: Relevant Data and Play Fairway Analysis Methods

This data catalog contains information on low temperature geothermal play types. The U.S. Department of Energy (DOE) Geothermal Technologies Office (GTO) supports the Geothermal Heating and Cooling Geospatial Datasets and Analysis project, conducted by the National Renewable Energy Laboratory (NREL). This project is part of a broader effort to demonstrate the multifaceted value of integrating geothermal power and geothermal heating and cooling technologies into national decarbonization strategies and community energy plans. There is a need to establish baseline low-temperature geothermal resource data sets and evaluate methods for deploying these technologies. This project aims to reduce exploration risk of low temperature geothermal systems by collecting baseline datasets that can be used for Play Fairway Analysis methodologies. This data catalog contains links to publicly available datasets from different sources that can be relevant for the low temperature geothermal systems. This submission contains data catalogs for Alaska, Hawaii, and the Conterminous United States, as well as a technical report on the methods used to classify and asses the geothermal play types.

15 GEOTHERMAL ENERGY↗

Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States

Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.

15 GEOTHERMAL ENERGY↗

Coupling Subsurface and Above-Surface Models for Optimizing the Design of Borefields and District Heating and Cooling Systems

Accurate dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange for seasonal energy storage. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes without flowing groundwater. While detailed simulation tools for subsurface heat and mass transfer exist, these fall short in simulating above-surface energy systems. To support the design and operation of such systems, the study developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the subsurface. For the first, it uses the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, it uses the TOUGH simulator. The TOUGH family of codes can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. The study validated the coupled modeling approach by comparing the simulation results with one from the g-function based ground response model. It then looked into effects when the water table and the regional groundwater flow are considered in the ground, from the perspective of heat exchange between borehole and ground, and the electrical consumption of the district heating and cooling systems. To access the simulation models, please find the links in the submission: -- For coupled approach validation: see model Buildings.Fluid.Geothermal.Borefields.Examples.BorefieldsWithTough and Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from the "Modelica Building Library" resource, branch issue1495_tough_interface, commit a2667c0. -- For the study of the effect of water table: see model Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO, commit 760de49. -- For the study of the effect of regional groundwater flow: see Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO_3D, commit c2a2d2a. The coupling interface script "GrounResponse.py" can be found from the above links in the folder Buildings/Resources/Python-Sources. Also, the needed files for TOUGH simulation are in the folder Buildings/Resources/Python-Sources/ToughFiles that can be accessed through the above links. A brief description of these files is given below; detailed specifications for the first three files may be found in the TOUGH3 Users Guide (Jung et al., 2018) https://tough.lbl.gov/documentation/tough-manuals/. (1) INCON - initial conditions for each grid block (2) INFILE - main input file with material properties and control parameters (3) MESH - description of the computational grid (4) readsave - Modelica/TOUGH interface program: read the final output of TOUGH simulation after TOUGH time step and prepare for transfer to Modelica for next Modelica time step (5) readsave.inp - input parameters for program readsave (6) writeincon - Modelica/TOUGH interface program: write the output of Modelica after Modelica time step and prepare for transfer to TOUGH as initial conditions for the next TOUGH step (7) writeincon.inp - input parameters for program writeincon

15 GEOTHERMAL ENERGY↗

Low-Temperature Geothermal Play Fairway Analysis for the Denver Basin: Preprint

This project is part of a national initiative to showcase the benefits of incorporating low-temperature geothermal resource assessment into the deployment of geothermal heating and cooling (GHC), combined heat and power (CHP), and geothermal direct use (GDU) technologies. The initiative was established to accelerate the country's decarbonization efforts by identifying potential for low-temperature geothermal resource utilization (< 150 Degrees Celsius, i.e., GHC, CHP, and GDU) in selected sedimentary basins with numerous population centers. The Play Fairway Analysis (PFA) methodologies in this study were adapted from previous PFA investigations of sedimentary basin geothermal play types (SBGPTs) that evaluated the potential for low-temperature resources (< 150 Degrees Celsius). Workflows, relevant datasets, python code, common and composite geological criteria maps are utilized to develop low-temperature geothermal resource favorability maps for the Denver Basin, a sedimentary basin spanning Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. To facilitate future assessment of low-temperature geothermal resources in SBGPTs, this project provides PFA workflows, data, tools, and favorability maps that will ultimately support the utilization of low-temperature geothermal resources in sedimentary basins.

Denver Basin↗

Low-Temperature Geothermal Geospatial Datasets: An Example from Alaska: Preprint

This project is part of a broader effort focused on geothermal heating and cooling with the purpose of demonstrating the multi-faceted value of integrating GHC/GHX into national decarbonization plans and community energy plans. Currently, there is a need to better define and evaluate low-temperature geothermal resource potential to provide the basis for supporting private sector investment. For shallow GHC/GHX fields, there is no formal compilation of subsurface characteristics shared among industry practitioners that can improve system design and operations. Alaska is specifically noted in this work, because heretofore, it has not received a similar focus in geothermal potential evaluations as the contiguous United States. The methodology consists of leveraging relevant data generate a baseline low-temperature resources (< 150 degrees C) geospatial dataset to compare and analyze information accessible to anyone trying to understand the potential of GHC/GHX and small-scale low-temperature geothermal power in Alaska (e.g., energy modelers, communities, planners, and policymakers). Importantly, this project is identifying data related to (1) the evaluation of GHC/GHX in the shallow subsurface, and (2) the evaluation of low-temperature geothermal resource availability. Additionally, data is being compiled to assess repurposing of oil and gas wells to contribute co-produced fluids toward the geothermal direct use and heating and cooling resource potential. The goal of this project is facilitating future deployment of GHC/GHX analysis and community-led programs and update the low-temperature geothermal resources assessment of Alaska. A better understanding of shallow potential for geothermal heat exchange (GHX) will improve design and operations of highly efficient GHC systems. The deployment and impact that can be achieved for low temperature geothermal resources will contribute to decarbonization goals and facilitate widespread electrification by shaving and shifting grid loads.

bottom-hole temperature↗

What are Geothermal Heat Pumps?

Learn how geothermal heat pumps (GHPs) work and why GHPs might be a perfect solution for your heating and cooling needs.

GEOTHERMAL HEAT PUMP↗

Grid Cost and Total Emissions Reductions Through Mass Deployment of Geothermal Heat Pumps for Building Heating and Cooling Electrification in the United States

This report presents the results of a study on the potential grid impacts of national-scale mass deployment of geothermal heat pumps (GHPs) coupled with weatherization in single-family homes (SFHs) from 2022 to 2050. GHPs are a technology readiness level 10, commercially available technology across the United States. This study is an impact analysis only; installed costs and available land areas for installing GHPs are not accounted for in determining their estimated deployment. The three scenarios studied were (1) continuing to operate the grid as it is today (the Base scenario), (2) a scenario to reach 95% grid emissions reductions by 2035 and 100% clean electricity by 2050 (the Grid Decarbonization scenario), and (3) a scenario in which the Grid Decarbonization scenario is expanded to include the electrification of wide portions of the economy, including building heating (the Electrification Futures Study or EFS scenario). The analysis team modeled each of these three scenarios with and without GHP deployment to a large percentage of US building floor space. In all cases, deployment of approximately 5 million GHPs per year demonstrated system cost savings on the grid, consumer fuel cost savings through eliminated fuel combustion for space heating, and CO 2 emission reductions from avoided on-site fuel combustion—and, in the case of the Base scenario, CO 2 emissions reductions from the electric power sector. GHPs have traditionally been viewed as a building energy technology. The most notable result of this study, however, is the demonstration that GHPs coupled with weatherization in SFHs are primarily a grid cost reduction tool and technology that, when deployed at a national scale, also substantially reduces CO 2 emissions, even in the absence of any other decarbonization policy.

15 GEOTHERMAL ENERGY↗