Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Grid Application and Controls Development for Medium-Voltage SiC-Based Grid Interconnects

This paper studies, the grid-interconnection requirements of directly connected medium-voltage (MV) Silicon Carbide-based (SiC-based) converters and details the necessary control implementations. These power electronic converters follow the interconnection standard IEEE 1547-2018, but can also have additional controls supported by the microgrid standards in IEEE 2030.7, which is demonstrated in this work. Additionally, this paper defines the grid applications realized by these directly connected medium-voltage power electronic converters at the distribution scale and demonstrates results. The controls for the studied grid applications are then developed and implemented on the controller. The paper also includes details of the control algorithm development and validations of the control algorithm through hardware-in-the-loop results.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Evolution of Distributed Energy Resource Grid Interconnection Standards for Integrating Emerging Storage Technologies

Grid interconnection standards facilitate safe and reliable grid integration of distributed energy resources (DERs). Evolution of a standard for DERs is expected to capture and accommodate widely different characteristics of DER and minimize unique grid integration challenges. This makes development of a uniform grid interconnection standard for all types of DERs a challenging and an ever-evolving consideration. This paper presents a detailed timeline of evolution, from the early 2000s to 2018, of DER interconnection standards and the research that informed their development. This is followed by a review of the research topics being considered in the grid integration of Energy Storage Systems (ESSs) which are expected to have the most significant growth amongst all DER types. These help in highlighting the need for a new standard to accommodate the unique characteristics of ESSs, and where the existing DER interconnection standard frameworks may be leveraged.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Interconnection and Renewables Deployment Related Air Quality and Human Health Benefits in Southeast Asia

The Association of Southeast Asian Nations (ASEAN) has increasingly focused on multilateral electricity trade, improved grid resiliency and modernization. These opportunities in the power sector have been studied through the ASEAN Interconnection Masterplan Studies, the most recent of which is the ASEAN Interconnection Masterplan Study III (AIMS III). AIMS III assessed four different scenarios of power system in the ASEAN countries that include a base scenario and three additional scenarios (called optimum RE, ASEAN RE, and High RE) considering different levels of deployment of renewable energy (RE) and cross-border generation and trade of electricity for three years (2025, 2030, 2040). In this work, we quantify the potential air quality and public health co-benefits of AIMS III scenarios. For a rapidly expanding, energy hungry region like SE Asia generation is power generation is expected to increase significantly. The AIMS III scenarios' capacity expansion modeling suggest that: 1) Generation nearly doubles from 2025 to 2040 in all four AIMS III scenarios; 2) Most of the increased generation is met by coal in all four AIMS III scenarios; 3) While renewables generation increases in all four AIMS III scenarios, the fraction of total generation (its share) generally decreases because of the much greater increase in non-renewable sources, mostly coal. Only in the High RE Target scenario do renewables represent a higher share in 2040 than in 2025, though even here it is at the expense of natural gas rather than coal; 4) As a result, emissions of gaseous and aerosol pollutants increase significantly in all scenarios. Because emissions increase in 2040 compared to 2025 for all four AIMS III scenarios, so do PM2.5 concentrations. Even for the High RE Target scenario (the scenario with highest share of renewable energy), compared to the Base scenario in 2025, in 2040 PM2.5 concentrations are higher. Compared to the Base scenario in the same years, the Optimum RE and ASEAN RE Target scenarios do not differ very much from the Base in terms of PM2.5 concentration. The High RE Target scenario, on the other hand, yields noticeably lower PM2.5 concentration. For example, in 2040 the population-weighted decrease in annual average PM2.5 concentration in the High RE Target scenario relative to the Base scenario is 0.5 ug m-3. Compared to the Base scenario in 2040, each of the alternative AIMS III scenarios is estimated to result in net reductions in power-sector air quality-related excess mortality in the ASEAN region. Yet there are a few countries for which the Optimum RE and ASEAN RE Target result in increases in PM2.5-related excess mortality (Thailand and Vietnam for the ASEAN RE Target scenario and Thailand for the Optimum RE scenario). However, for the High RE Target scenario, all countries benefit and find reductions in excess mortality resulting from the power sector scenarios modeled in AIMS III with regionwide mortality decreasing by 16,000 compared to the Base scenario in 2040. In summary, our analysis finds that changing power generation emissions is a crucial lever for improving public health in ASEAN member countries and provides a pathway for policymakers to make decision backed by a realistic power sector expansion and air quality analyses.

air quality↗

Flexible Grid Interconnections

Key Considerations: - Long-term coordination and collaboration with utilities and ISOs may provide mutual benefits and support flexible interconnectivity. - Onsite storage and energy production can reduce load fluctuations and support grid resilience in the future. - Geography and resource availability can impact energy demand and grid flexibility.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

IM3 Projected U.S. Western Interconnection Grid Stress Dataset

This dataset provides projected grid stress and reliability results (including all model inputs and outputs from GO WEST and TEP) for Integrated Multisector, Multiscale Modeling (IM3) Phase 2 simulations across eight different scenarios for the U.S. Western Interconnection through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States from a set of Thermodynamic Global Warming (TGW) simulations. These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 GO WEST is an open-source power grid modeling framework for the U.S. Western Interconnection, which allows users to tailor the model depending on their research study and science questions. It covers 28 balancing authorities (BAs) and 12 states in U.S. Western Interconnection. GO WEST allows users to select different number of nodes and come up with a simplified network by utilizing 10,000 nodal topology of the U.S. Western Interconnection (ACTIVSg10k). Users can select different number of nodes, mathematical formulations (linear programming vs. mixed-integer linear programming), transmission line limit scaling factors, and hurdle rate scaling factors. GO WEST offers a unit commitment and economic dispatch (UC/ED) module to simulate grid operations on an hourly scale. In this sense, users can calibrate and validate their model versions by comparing model outputs to historical datasets. TEP is an open-source transmission capacity expansion model, built on the GO WEST framework. It utilizes linear programming to optimize transmission capacity addition investment on existing lines within the GO WEST framework. The TEP model only increases the thermal capacity of existing transmission lines and does not add new lines to the system, which leaves the topology preserved. In order to use TEP model, users need to create scenarios with the GO WEST framework. Please refer to README file for a detailed description of the dataset including individual files and references.

Capacity Expansion Model↗

Automation for Grid Interconnected Laboratory Emulation

As computational capabilities improve, digital twins are becoming vital for evaluating equipment realistically in laboratories. This paper outlines a digital twin architecture for the power grid, employing electromagnetic transient (EMT) simulation alongside real-time simulation of power hardware and hierarchical control systems. EMT simulation occurs on a high-performance computing server for scalability. Additionally, the paper describes a workflow and real-time data streaming software facilitating connectivity among EMT simulation, hierarchical control systems, and power hardware. This software enables automated equipment connectivity in the laboratory for realistic evaluations, aiding in identifying necessary upgrades for both equipment control systems and the power grid.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

The Electric Grid, Distributed Generation, and Grid Interconnection

This fact sheet is part of the Community Planning for Solar toolkit designed to help Massachusetts municipalities and others proactively plan for solar development in their communities. This fact sheet will walk you through the electricity system, and help you understand how the grid is changing as distributed generation (DG) electricity sources become more common.

14 SOLAR ENERGY↗

Inertia Estimation and Trend Analysis of the United States Power Grid Interconnections

The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.

30 DIRECT ENERGY CONVERSION↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Energy Hub Based on Multilevel Cascaded H Bridge-Dual Active Bridge Back-to-Back Converter for Power Distribution Feeders Interconnection and Multiple Simultaneous Grid Services

This paper presents a medium voltage energy hub based on a modular design of a multilevel cascaded H bridge (CHB)-dual active bridge (DAB) converter. The energy hub composed of the two CHB-DAB modules with a back-to-back topology can be utilized as a grid interconnection component between distribution feeders. The energy hub can provide multiple simultaneous grid services such as voltage regulation, power factor correction, as well as active power flow control between the connected feeders, contributing to grid flexibility, efficiency, reliability, and resilience. Circuit structure and control schemes for the energy hub including both local controllers for each converter and outer loop controllers are proposed to enable simultaneous grid services with coordination to prevent the overloading of the hub. To validate the performance of the hub, the hub system is interconnected between two IEEE 4-bus feeders and provides voltage regulation for both feeders, while controlling active power flow between them. The system and the feeders are implemented in Real-Time Digital Simulator (RTDS) for real-time simulation verification.

Choi, Jongchan↗

UL 1741SC Conformance Development, Evaluation, and Proposal [Slides]

V2G AC is a type of grid interconnection by mobile battery that transforms an EV into a DER with the potential to stabilize the grid and lower costs for electricity. UL 1741SC is a critical new standard to enable grid interconnection of V2G AC-capable vehicles, by defining requirements for V2G AC-intended EVSEs as a gatekeeper between the grid and the EV to support grid safety, such as through redundant voltage trip (namely oversight). EVSE manufacturers need a clear set of conformance test cases and criteria by which to evaluate their equipment and confirm the compliance with UL 1741SC, so that the EVSEs performs as intended for the grid safety. Hence, NLR identified necessary conformance tests and performed the tests identified to understand the maturity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Comprehensive Method to Mitigate Forced Oscillations in Large Interconnected Power Grids

Multiple severe forced oscillation events have recently been observed across the North American interconnections and around the world. These forced oscillations have caused power swings, limited power transfer capability, damaged equipment, and persisted indefinitely until the driving source was located and removed. This paper proposes a comprehensive method to mitigate forced oscillations. Once a forced oscillation is detected, a new source location algorithm can be used to locate the source based on the oscillation mode angle without requiring system topology information. If the source cannot be quickly located and removed, a control strategy can be activated to modulate the active power of utility-scale inverterbased battery energy storage systems (BESSs) to reduce the energy of forced oscillations to a safe level and allow sufficient time for locating the exact source. The proposed source location algorithm is validated using measurements collected during the January 11, 2019 forced oscillation event in North America and other actual grid events, while the proposed control strategy is verified using the Eastern Interconnection dynamic model under the replicated January 11, 2019 forced oscillation event. The simulation results demonstrated that the proposed source location algorithm can accurately identify the forced oscillation source, and the proposed control strategy can significantly reduce forced oscillation energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.9, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

13 HYDRO ENERGY↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation

This paper develops a controller for a grid-forming (GFM) inverter that is capable of operating as either a GFM or grid-feeding source that can improve the operation of a microgrid during on-off grid transitions through use of a novel synchronization approach. Furthermore, this controller avoids use of a phase-locked loop (PLL) and the inverter is able to synchronize with the grid with self-generated voltage and frequency. This prevents the inverter from replicating any grid voltage disturbances in its output—a key disadvantage of many grid-connected inverters that use a PLL. To enable fast synchronization, active synchronization control is adopted both during inverter start-up and microgrid reconnection operation and a method of coordinating synchronization of the inverter with a microgrid controller and grid interconnection circuit breaker is presented. Simulation results for multiple microgrid transition operations and unplanned islanding events demonstrate that the developed non-PLL grid-connected GFM inverter controller and synchronization method are effective in synchronizing the inverter and microgrid to the grid, avoiding phase jump during microgrid transition operation, and improving microgrid islanding transients versus a traditional configuration.

27 ARPA - Advanced Research Projects Agency-Energy↗

Enhancing Cloud Cybersecurity: Prescriptive Controls for Operational Technology

This whitepaper provides strategic insights and recommendations into security cloud-based solutions for electric utilities, encompassing operational technology (OT), virtual power plants (VPP), distributed energy resources (DERs), applications, networks, and data storage as they transition to and leverage cloud infrastructure through managed service providers (MSPs) and cloud service providers (CSPs). Principles derived from established frameworks serve as a foundation for best practices across cybersecurity projects and remove the constraints of settling on a single framework. For organizations that prefer not to integrate a specific framework altogether, elements of the proposed approach could be adopted or tailored to best fit defined requirements and expected functionalities. The Cirrus assessment, a utility cloud feasibility tool, and the roadmap it provides serve as a precursor to this paper, which seeks to be a valuable resource for defining next steps following cloud technology integration feasibility appraisal. With its comprehensive approach to adoption, the Cirrus framework offers strategic guidance on responsibly preparing for or deploying a utility cloud solution. The previously published whitepaper, “Use Case-Informed Framework for Utility Cloud Migration,” details the guiding strategy, research, and deployment of cloud solutions within electric and interconnected grid systems. Before implementing the controls suggested in this document, it is recommended that stakeholders complete Cirrus's cloud integration assessment and pair the results with their unique cybersecurity controls to form a comprehensive cloud-based utility cybersecurity plan. The Cirrus outcome will consider a series of future architectures for the grid before and after the energy transition and evaluate the arguments for and against cloud applications for each electric and interconnected grid layer. This document is a companion to the original whitepaper, "Use Case-Informed Framework for Utility Cloud Migration" to further identify and recommend security controls based on Cirrus’s cloud integration assessment output. The following whitepaper outlines the cybersecurity controls that secure cloud-service models pertinent to the electric sector using the predefined categories identify, protect, detect, and respond and recover. The objective is to outline prescriptive security controls based on the type of architecture and data stored in the cloud. The focus includes dissecting the shared responsibility model and elucidating what on-premises Infrastructure as a Service (IaaS), Platform as a Service (PaaS), and Software as a Service (SaaS) entail. A pivotal consideration in this context is allocating responsibility for foundational cybersecurity aspects—having used Cirrus for the cloud integration assessment. The ensuing controls detailed herein also represent a checklist of controls necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and strategic foresight in a safe and responsible manner.

42 ENGINEERING↗

A hub and spoke approach to optimizing energy wheeling of renewable resources

The deployment of zero carbon renewable energy sources needs to increase significantly to support the goal of net zero greenhouse gas emissions by 2050. At the same time energy end use needs to decarbonize. This will change both energy supply and energy demand patterns, requiring the energy delivery infrastructure (grid-based transmission circuits) to become increasingly flexible to maintain security of supply everywhere and always. The integration of zero carbon renewable energy requires cross-border and cross energy system coupling and a fit-for-purpose design. Nowadays, energy systems are planned, designed and operated in silos with a strong national focus. However, large-scale offshore wind production needs to be transported to deep inland locations, across country borders. The increased peak generation capacity of renewable energy sources will, at times, significantly exceed demand (Matthew Langholtz, 2020). The traditional solution of continuously reinforcing and extending the electricity grid is not sustainable from a cost and societal perspective. This paper will, however, propose a deterministic approach on how networked (interconnected grid) Points of receipt (POR) to Points of Delivery (POD) can be optimized for wheeling renewable energy resources while minimizing energy cost with a hub and spoke approach. The statistical approach will be done via using existing daily energy market clearing prices, available transmission capacity and firm daily transmission prices in open access energy markets. Renewable energy targets, including specific offshore wind targets, need to be in line with the ramp-up as implied by the Paris Agreement. These targets are required to provide industry with a secure market outlook that allows them to build up supply chains accordingly. Optimizing wheeled energy paths from carbon neutral resources such as renewables make them not only cost competitive on the unit commitment stack, but also more accessible on the dispatch stack to other carbon heavy forms of generation such as coal and natural gas turbines (Matthew Langholtz, 2020). This correlates to maximizing renewable resource inertia (wind, solar, biomass) within an interconnected grid without having to consider additional expansion of resources via land purchases and de-forestation.

Mukherjee, Srijib↗

Line Faults Classification Using Machine Learning on Three Phase Voltages Extracted from Large Dataset of PMU Measurements

An end-to-end supervised learning method is developed to classify transmission line faults in a twoyear field-recorded dataset that includes synchronized measurements of three-phase voltages recorded by 38 Phasor Measurement Units (PMU) sparsely located in in the US Western Grid interconnection. Statistical analysis is performed to extract features from this large dataset to train Support Vector Machine (SVM), Random Forest (RF), and eXtreme Gradient Boosting (XGBoost) classifiers initially. The training further leverages a simulated dataset from a synthetic grid with 12 PMUs to increase the number of faults of types infrequently seen in the field-recorded dataset. Training the classification models with the combined dataset resulted in a classification accuracy of 97.7%. This is a significant improvement over 89.7% to 92.5% accuracy obtained by relying on the field-recorded dataset alone.

47 OTHER INSTRUMENTATION↗

The Renewable Energy Potential (reV) Model: A Geospatial Platform for Technical Potential and Supply Curve Modeling

The Renewable Energy Potential (reV) model is a platform for detailed assessment of renewable energy (RE) resources and their geospatial intersection with grid infrastructure and land use characteristics. The reV model currently supports photovoltaic (PV), concentrating solar power (CSP) and land-based wind turbine technologies. Modules in the reV framework function at different spatial and temporal resolutions, allowing for assessment of resource potential, technical potential and supply curves at varying levels of detail. The platform runs on NREL's High Performance Computing system, providing scalable and efficient performance from a single location all the way up to continental scales, for a single year or decades of time series resource data. Coupled with NREL's System Advisor Model (SAM), reV supports resource assessment from 5-minute to hourly temporal resolution and provides for analysis of long-term (i.e., year-on-year) variability of RE generation (e.g., interannual variability and exceedance probabilities). Technical potential is measured as a function of resource potential and limitations put on developable land area defined by the user. For example, the user can limit development by land ownership, terrain, land use/cover, and urban areas, as well as custom inputs. Technology, grid interconnection and operation costs, based on the latest market data and future projections, are also embedded in the model. The supply curve module is a spatial sorting algorithm based on plant siting, grid interconnection cost, and regional competition, which provides a geographically discrete estimate of levelized cost of electricity (LCOE) and supply (i.e., capacity) for specific renewable technologies. The reV model currently provides broad coverage across North America, South and Central Asia, South America and South Africa to inform national- and international-scale analyses as well as regional infrastructure and deployment planning.

13 HYDRO ENERGY↗