Search NASASearch

SEARCH · Search NASA

Results for “Heat removal system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Optimization of the FRIB beam dump: a hybrid genetic algorithm and reinforcement learning approach

The operational envelope of high-power-density systems, such as particle accelerators and advanced nuclear energy systems, is critically constrained by the need to manage extreme thermal loads. To address this, we present a novel hybrid optimization framework combining a genetic algorithm (GA) with a soft actor-critic (SAC) deep reinforcement learning agent. This framework was applied to a practical high-heat-flux problem: redesigning the beam dump at the Facility for Rare Isotope Beams (FRIB) for a power upgrade from 20 kW to 50 kW. The resulting design, validated by three-dimensional conjugate heat transfer simulations, suppresses hazardous hot spots and yields a markedly more uniform temperature distribution. This provides a robust operating margin, increasing the average power-handling capability by 72% relative to the current design, demonstrating the framework’s potential to solve complex thermal management challenges in both accelerator technology and advanced nuclear systems.

Accelerator

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine

Bosch Carbon Catalyst Regeneration in Water I: Bosch Carbon Removal from Reacted Beads Utilizing Mechanical Agitation

The ability to recover oxygen from metabolic carbon dioxide is crucial for crewed long duration missions in which the atmosphere must be recycled. Two physiochemical methods are primarily employed for this purpose: the Bosch process and the Sabatier reaction. This paper focuses on the Bosch process. It utilizes hydrogen in the presence of a catalyst to form water and solid carbon out of metabolic carbon dioxide. The solid carbon product deposits onto the catalyst and eventually causes reactor over pressurization issues. Multiple methods are currently being investigated to regenerate the catalyst’s surface and break up the pressure causing carbon clogs. This paper explores whether water and mechanical abrasion would work to remove Bosch carbon by testing multiple washing conditions. The different washing conditions involved agitation intensity, heating, duration, and volume of water. It was found that it is possible to break up the clumps of carbon formed in the reactor through agitation with room temperature water in one hour and shows promise for completely cleaning the carbon off the beads’ surface.

Agitation

Equivalent System Mass Comparison of ECLSS CO2 Removal Technologies

This project employs equivalent system mass (ESM) analyses to evaluate and compare state-of-the-art spacecraft CO2 removal systems. The ESM methodology converts sizing characteristics such as volume, power, and cooling requirements into a unified metric of mass, allowing for simple quantitative comparison of equipment impacts on a system level. Comparison of six high TRL technologies – the Carbon Dioxide Removal System (CDRS), Thermal Amine Scrubber (TAS), Carbon Dioxide Removal Assembly (CDRA), Four-Bed CO2 Scrubber (4BCO2), CO2 and Humidity Control Swing Bed (CHC), and the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) – was achieved using an existing ESM spreadsheet tool that formerly ranked such technologies for consideration on Gateway. Fidelity of the tool was increased through revision with the most up-to-date sizing and performance data for each technology. ESM values were then estimated using NASA-supplied Lunar, Martian, and low-Earth orbit habitat infrastructure costs. This paper details the ESM approach used, lists major performance variables for each CO2 removal option, and summarizes conclusions of the technology comparison. The results are intended to act as a guide to assist programs in their selection of CO2 technologies best suited for a specific vehicle or mission.

Madeleine C Oliver

Equivalent System Mass Comparison of ECLSS CO 2 Removal Technologies

This project employs equivalent system mass (ESM) analyses to evaluate and compare state-of-the-art spacecraft CO 2 removal systems. The ESM methodology converts sizing characteristics such as volume, power, and cooling requirements into a unified metric of mass, allowing for simple quantitative comparison of equipment impacts on a system level. Comparison of six high TRL technologies – the Carbon Dioxide Removal System (CDRS), Thermal Amine Scrubber (TAS), Carbon Dioxide Removal Assembly (CDRA), Four-Bed CO 2 Scrubber (4BCO2), CO 2 and Humidity Control Swing Bed (CHC), and the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) – was achieved using an existing ESM spreadsheet tool that formerly ranked such technologies for consideration on Gateway. Fidelity of the tool was increased through revision with the most up-to-date sizing and performance data for each technology. ESM values were then estimated using NASA-supplied Lunar, Martian, and low-Earth orbit habitat infrastructure costs. This paper details the ESM approach used, lists major performance variables for each CO 2 removal option, and summarizes conclusions of the technology comparison. The results are intended to act as a guide to assist programs in their selection of CO 2 technologies best suited for a specific vehicle or mission.

Madeleine Oliver

Advanced Space Power PEM Fuel Cell Systems

A model showing mass and heat transfer in proton exchange membrane (PEM) single cells is presented. For space applications, stack operation requiring combined water and thermal management is needed. Advanced hardware designs able to combine these two techniques are available. Test results are shown for membrane materials which can operate with sufficiently fast diffusive water transport to sustain current densities of 300 ma per square centimeter. Higher power density levels are predicted to require active water removal.

PEM

Heat Capacity and Thermal Relaxation of Bulk Helium Very Near the Lambda Point

In October 1992 a low temperature experiment was flown on the Space Shuttle in low Earth orbit. The objective of the mission was to measure the heat capacity and thermal conductivity of helium very close to the lambda point with the smearing effect of gravity removed. We report preliminary results from the experiment, and compare them with related measurements performed on the ground. The sample was s sphere of helium 3.5 cm in diameter contained within a copper calorimeter of vey high thermal conductivity. The calorimeter was attached to a pair of high resolution paramagnetic salt thermometers with noise levels in the 10 -10 K range and suspended from a high stability thermal isolation system. During the mission we found that the resolution of the thermometers was degraded somewhat due to the impact of charged particles. This effect limited the useful resolution of the measurements to about two nanokelvins from the lambda point. The results reported here are limited to about ten nanokelvins from the transition.

John A Lipa

Design and Analysis of Battery Thermal Management Systems

Thermal management of battery cell packs is a critically needed technology. The purpose of this work is to design new and improved Battery Thermal Management Systems (BTMS) for use in electric airplanes. The BTMS should be 3D printable and hold twelve to sixteen 18650 batteries. To minimize aircraft’s weight, an actively air-cooled battery pack was chosen to avoid the excess weight of water-cooled and phase change material (PCM) cooled packs. As a result, significant changes were made to remove all metal in the pack and replace it with lower density polymer matrix composites (PMCs) which can be additively manufactured. Two air cooled battery pack configurations (traditional propeller fans & bladeless fans) were designed, modeled, and compared. These packs were first modeled in SolidWorks 2021 3D CAD, then imported into COMSOL MultiPhysics to be studied using the “Heat Transfer in Solids and Fluids” module. The design with the bladeless fans eliminated the need to use high conductivity heavy metal to remove unwanted thermal energy. These bladeless fans were designed entirely out of PMCs. This thermal pack design weighs 0.04 kg less than that of the traditional propeller fans design and has increased the battery pack energy density by 8.25 Wh/kg.

Thermal Management System for Battery Packs

Characterization of the Mechanical Trash Compactor Bag Removal Force

Managing trash accumulation is a critical challenge in human space explorations since the trash volume and mass can significantly influence launch cost and operational efficiency. This study aids the development of a Mechanical Trash Compactor (Mpactor) by testing the removal force required to remove a “trash bag” from the Mpactor. To do this, a Pneumatic Pressure Mandrel System was designed to simulate the normal force trash would exerts on the trash bag and subsequently the sidewalls of the Mpactor. For various levels of sidewall normal force, the removal force required to remove the simulated trash bag from the Mpactor compaction chamber was measured. This testing is used to identify optimal bag materials. Additionally, testing was done on both the native stainless steel walls of the compaction chamber as well as the walls after being Teflon lined. Split-plot ANOVA, simple main effects analysis, Holm’s post hoc comparisons for interaction, and sensitivity analyses were conducted to assess the influence of trash bag and sidewall materials on the required removal force. It was found that Teflon reduced the force required to remove the trash bag as well as reduced material-dependent variation in removal force. Testing showed that Teflon reduced the required removal force with a Polyvinylidene Fluoride , an unidentified Ethylene acrylate - Low Density Polyethylene copolymer, and a Polyvinyl Chloride all requiring significantly less removal force than the other materials tested.

pressure mandrel

Spacecraft Fire Safety Predictions using Verified Saffire Model

A model developed using Fire Dynamics Simulator (FDS) that aimed to determine the effect of a fire in a spacecraft was validated by data collected during the Saffire campaign. The model used inlet and outlet temperatures and CO 2 concentrations of the Saffire payload where fire spread was taking place to determine the amount of heat and combustion products that made it into Northrop Grumman’s Cygnus vehicle. The model was then validated using six remote sensors in various places in the vehicle, as well as a far field device (FFD) in the open zenith section that was representative of average vehicle values. The current work focuses on using the model to predict fire safety scenarios. One simulation aimed to determine the fate of HCl, which sticks to surfaces. The model prediction showed that the HCl was removed from the atmosphere rapidly. This compared well against the FFD data in the Saffire VI campaign event where a bottle of 5% HCl was released into the vehicle. An additional simulation where the Environmental Control and Life Support System (ECLSS) was shut off once the FFD reached 5 ppm of HCl showed that HCl stayed in the atmosphere considerably longer. Continuing the simulation with the ECLSS activated and after temperatures returned to their initial conditions, resulted in a rapid removal of HCL similar to that observed in the original HCl release scenario model. Finally, a simulation that used the heat release rate from a lithium-ion battery test to determine the effect it would have on a spacecraft was performed. This simulation used a heat addition rate that is considerably higher than what was determined from the burning of solid fuels in the Saffire campaign and hence produced a non-trivial temperature increase in more locations within the vehicle.

Fire Safety

NuMI Graphite Target Fin Removal Assembly

Materials scientists want to study the irradiated graphite target from the Neutrino at the Main Injector (NuMI) beam line. In order to gather these irradiated graphite fins from the target canister, it will have to be done remotely. Therefore, a removal assembly will need to be created in order to do this efficiently and well. This project aims to make progressive steps towards deploying the final target removal assembly. Furthermore, calculations related to the removal assembly design were done, and tests were planned to discover further information about the feasibility of this design. The main result from this project is the deflection of the cantilever arm, which is 0.354 inches due to the weight of the beam and cutting tool. Additionally, more results of this project are the testing assembly CAD model and the feasibility of design. This project concludes that there is still more work that needs to be done for the removal assembly to be deployed, but there were foundational steps that were made in the implementation of this design. Finally, there should be further steps and tests to determine the feasibility of this removal assembly.

Malovski, Azra [NIU, DeKalb]

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling

Overcoming the Entropy Penalty of Direct Air Capture for Efficient Gigatonne Removal of Carbon Dioxide

Atmospheric carbon poses an existential threat to civilization via global climate change. Hundreds of gigatonnes of carbon dioxide must be removed from earth’s atmosphere in the next three decades, necessitating a low-cost, energy-efficient process to extract low concentrations of carbon dioxide for conversion to a stable material permanently stored for thousands of years. In this work, the challenge of removing gigatonnes of CO 2 is described via the scale of effort and the thermodynamics of collecting and reducing this diffuse chemical, the accumulation of which imparts a substantial entropy penalty on any atmospheric carbon capture process. The methods of CO 2 reduction combined with upstream direct air capture (DAC) including absorption, membrane separation, and adsorption are compared with biomass torrefaction and permanent burial (BTB). A Monte Carlo model assesses the mass, energy, and economics of the full process of biomass torrefaction from biomass collection and transport to stable carbon burial to determine that 95% of scenarios could remove carbon for less than $200 per CO 2 -tonne-equivalent. Torrefied carbon is further discussed for its long-term stability and availability at the scale required to substantially mitigate the threat of climate change.

biomass