Search NASA⌕ Search

SEARCH · Search NASA

Results for “Helmholtz coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Water-cooled Helmholtz coil for Ultra-low Magnetic Field Testing

Ultra-low magnetic field testing requires precise and finely calibrated instrumentation interacting with very marginal magnetic fields in highly controlled environments. We designed a large Helmholtz coil system for implementation around a 17.825-inch outer diameter Helium-3 Cryogenic fridge, to serve as both a field-zeroing device and to enable higher resolution on magnetic field sweeps during experiments. We present finite volume modeling and finite element analysis results which indicate the device could safely run at 20 [A] in perpetuity, producing a magnetic field of 65 [mT], without the surface facing the Cryogenic fridge exceeding 50°C. The overall system parts expense is $\$$4,882.76.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bioinspired aligned magnetic features in aerogels for humidity sensing

Many natural plant tissues, such as pinecones, utilize structures to transduce changes in humidity into movement or strain. These often employ layered structures with aligned features in order to create differential stress across the material as different portions swell at different rates. Here, by replicating these types of structures in synthetic materials we can create structures that respond to humidity in a similar manner. Taking these aligned features as inspiration, silica aerogels with tailored humidity reactive properties were created. This behavior was achieved by creating aligned features in these aerogels using a Helmholtz coil to produce a uniform magnetic field that aligned ferrofluid droplets into chains and needle like features. These magnetite-based structures were shown to retain their superparamagnetic properties, allowing them to easily be removed from the aerogels, leaving a large number of aligned channels. Aerogels with the removed needles experienced significantly different strains than both unmodified aerogels and aerogels with the aligned features still in place. Aerogels with these tunable aligned features could be used in humidity sensors that can transduce changes in humidity into strain and could be used in applications such as volatile organic compound capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING↗

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation↗

Understanding the impact of an applied axial magnetic field on efficient current coupling on the Z machine

Magnetized liner inertial fusion (MagLIF) is an attractive concept for producing thermonuclear fusion reactions. The MagLIF platform involves the operation of Helmholtz coils to apply a 15 Tesla axial magnetic field to the load region, where a cylindrical, fuel-filled metal liner is imploded by a ∼ 2 0 MA current pulse. The fringe field from these coils extends into the transmission line that delivers the current to the target. We investigated the extent to which this applied field disturbs the nominal power flow within that transmission line. A simplified model of the geometry shows that adding the applied magnetic field results in magnetic field lines that connect the cathode to the anode, suggesting electrons may not be magnetically insulated in this region. Particle-in-cell simulations indicated the addition of the applied magnetic field would not significantly impact the current delivery to the load. Velocimetry was used to experimentally assess the current delivery with and without the applied magnetic field. We find no measurable effects of the applied field on current delivery in the configuration investigated in this study. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Radiative Magneto-Hydrodynamics of Colliding Flow: Instabilities, Reconnection and Exoplanet Atmosphere Connections

Hypersonic flows of magnetized plasmas naturally produce strong shocks when obstructions or self‐interactions (flow collisions) occur. Such complex flows occur in a wide variety of HEDP settings such as Z‐pinches and laser driven implosion experiments that include magnetic fields via explosive Helmholtz coils (MIFEDS) When thermal energy behind the shocks can be lost to optically thin radiation, the flow dynamics becomes even more complex, admitting a range of new instabilities such as the Nonlinear Thin Shell Instability (NTSI). Because of their inherent non‐ linearity, multi‐dimensionality and time‐dependence (i.e. turbulence), the ability to articulate the underlying physics of colliding hypersonic magnetized flows represents a significant frontier in HEDP studies. The addition of radiative cooling to these flows propels the study even further into the domain of extreme plasma physics. Exploration of these forms of HED plasmas is of interest to basic plasma physics as well as of interest for their application to Inertial Confinement Fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of the electrothermal instability from thick rod z pinches subject to dynamically and statically applied axial magnetic field

LDRD Project 229427 aimed to determine how electrothermal instability (ETI) driven heating on a z-pinch rod pulsed with intense current evolves under mixed magnetic field (azimuthal + axial) conditions, which is pertinent to pulsed-power-driven magnetically-insulated transmission lines and physics targets. Experiments focused on diagnosing ETI-driven heating from deliberately-machined and well-characterized micron-scale surface defects (referred to as engineered defects or ED). Prior to the start of this project, understanding of how unmagnetized (B z =0) ED evolve had been obtained—simulations largely reproduce the experimentally observed high temperature spots which develop at the poles of bare/uncoated ED. Project 229427 extended the Mykonos Facility ED experimental platform to include axial field. In the first class of experiments, axial field was provided “dynamically” via a helical return can (HRC). In this case, B z and B θ rise at the same rate. Generally, the HRC generated magnetic field at a fixed polarization angle Φ B =arctan(B z /B θ )=15° on the rod's surface. In the second class of experiments, axial field was provided “statically” via a slow-rising (millisecond) external Helmholtz coil pair. In this case, B z was effectively constant/static throughout the 100 ns rise of the Mykonos current. For either case, a primary goal was to determine whether ETI provides a helical seed perturbation for the subsequent growth of the helical magneto Rayleigh-Taylor modes observed in MagLIF (static B z ) and dynamic screw pinch (DSP, dynamic B z ) experiments. When dynamic field was applied using an HRC, emissions from individual ED aligned toward Φ B , while emissions from ED within pairs elongated and preferentially merged along Φ B . These data strongly support that for a randomized defect distribution, heating from nearby current-density perturbations will favorably merge about Φ B to generate an extended seed perturbation that aligns toward the surface-field polarization, and this may impact the orientation of subsequent MRT growth on imploding liners. The results from the static field experiments were largely inconclusive, as any ETI heating rotation, if present, was obscured/overwhelmed by local/random heating from ED rim imperfections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstrating magnetic field robustness and reducing temporal T1 noise in transmon qubits through magnetic field engineering

The coherence of superconducting transmon qubits is often disrupted by fluctuations in the energy relaxation time (T1), limiting their performance for quantum computing. While background magnetic fields can be harmful to superconducting devices, we demonstrate that both trapped magnetic flux and externally applied static magnetic fields can suppress temporal fluctuations in T1 without significantly degrading its average value or qubit frequency. Using a three-axis Helmholtz coil system, we applied calibrated magnetic fields perpendicular to the qubit plane during cooldown and operation. Remarkably, transmon qubits based on tantalum-capped niobium (Nb/Ta) capacitive pads and aluminum-based Josephson junctions (JJs) maintained T1 lifetimes near 300 μs even when cooled in fields as high as 600 mG. Both trapped flux up to 600 mG and applied fields up to 400 mG reduced T1 fluctuations by more than a factor of two, while higher field strengths caused rapid coherence degradation. We attribute this stabilization to the polarization of paramagnetic impurities, the role of trapped flux as a sink for non-equilibrium quasiparticles (QPs), and partial saturation of fluctuating two-level systems (TLSs). These findings challenge the conventional view that magnetic fields are inherently detrimental and introduce a strategy for mitigating noise in superconducting qubits, offering a practical path toward more stable and scalable quantum systems.

Abdisatarov, Bektur [Fermilab; Jefferson Lab]↗

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗

Development of the high energy engineering X-ray (HEX) superconducting wiggler, magnetic measurement, installation, and commissioning

The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. Here, this paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.

36 MATERIALS SCIENCE↗

Quantifying trapped magnetic vortex losses in niobium resonators at mK temperatures

Trapped magnetic vortices in niobium introduce microwave losses that degrade the performance of superconducting resonators. While such losses have been extensively studied above 1 K, we report here their direct quantification in the millikelvin and low-photon regime relevant to quantum devices. Using a high-quality factor 3D niobium cavity cooled through its superconducting transition in controlled magnetic fields, we isolate vortex-induced losses and find the resistive component of the sensitivity to trapped flux S to be approximately 2 n Ω/mG at 10 mK and 6 GHz. The decay rate is initially dominated by two-level system (TLS) losses from the native niobium pentoxide, with vortex-induced degradation of T 1 occurring above B trap ∼ 50 mG. In the absence of the oxide, even 10 mG of trapped flux limits performance, Q 0 ∼ 10 10 , or T 1 ∼ 350 ms, underscoring the need for stringent magnetic shielding. The resistive sensitivity, S, decreases with temperature and remains largely field-independent, whereas the reactive component, S′, exhibits a maximum near 0.8 K. These behaviors are well modeled within the Coffey–Clem framework in the zero-creep limit, under the assumption that vortex pinning is enhanced by thermally activated processes. Our results suggest that niobium-based transmon qubits can tolerate vortex-induced dissipation at trapped field levels up to several hundred mG, but achieving long coherence times still requires careful magnetic shielding to suppress lower-field losses from other mechanisms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic↗

Exploring Microphase Separation in Semi-Fluorinated Diblock Copolymers: A Combined Experimental and Modeling Investigation

We report the combined experimental and theoretical study of the bulk self-assembly behavior of polystyrene-blockpoly( 2,3,4,5,6-pentafluorostyrene) diblock copolymers. These block copolymers were designed to create highly antagonistic blocks (with a high Flory−Huggins interaction parameter, χ) with minimum disruption to the molecular construct (i.e., only replacing five hydrogen atoms with five fluorine atoms). A large library of diblock copolymers (41 samples) was synthesized by reversible addition− fragmentation chain transfer (RAFT) polymerization to map out a major portion of the phase space. All block copolymers exhibited narrow molecular weight distributions with dispersity (D) values between 1.07 and 1.32, and subsequent thermal annealing revealed phase separation into well-defined nanoscale morphologies depending on their molecular composition, as determined from small-angle X-ray scattering and transmission electron microscopy analyses, with an experimental phase diagram being constructed. The χ value at 25 °C for this block copolymer was estimated to be 0.2 using strong segregation theory, based on trends in phase-separated domain spacing and interfacial width. When applying theoretical approaches, the majority of the domain spacing data trends were captured by a coil−coil diblock copolymer model; however, a better fit to the data for samples with shorter fluorinated blocks was obtained with a rod−coil model, indicating that the chains in these fluorinated blocks likely have a higher inherent stiffness and were thus rod-like. This observation demonstrates that, due to the very high value of χ, a transition from coil−coil to rod−coil behavior can be obtained purely by reducing the length of the stiffer of the two blocks and without varying temperature or the chemical composition of the polymers. Here, this work showcases the presence of strong microphase separation within AB diblock copolymers despite the relatively similar chemical composition of the constituent “A” and “B” units, with a clear transition from rod−coil to coil−coil segregation behavior.

RAFT polymerization↗