Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hole cleaning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A technique for making clean holes in metallic piping and components

Testing was conducted to develop a technique of providing clean holes in process piping or in a metal surface accessible from one side only without disassembling the system. The method was performed on sample pieces of piping and worked successfully with no contaminants being found on the inside of the pipe. The materials tested were Inconel 600, 304 stainless steel, Hastelloy X, and ASTM-A53 black steel. The technique was developed such that it could be done in the field with hand-held power tools and a portable tungsten inert gas welding machine.

Hecker, T. P.↗

Drill bit design assures clean holes in laminated materials

Drill bit eliminates delamination when drilling laminated material. It cuts or shaves the material as it progresses through it. The bit acts to hold down the material during drilling to prevent tearing or ripping and produces a clean, smooth and defect-free hole. It prevents chipping in stretched plastic windows for high-altitude, high-performance aircraft.

Tillotson, R. N.↗

Tools Make Clean Holes In Honeycomb Panels

Three tools designed used together to prepare honeycomb panels for insertion of hardware to support structural members or electronic packages. Tools speed up and simplify time-consuming operation of manually pushing honeycomb material aside to make room for spool-shaped mounting insert. Tools are core cutter, spotface cutter, and displacement tool.

Wells, Dott↗

Cutting holes in fabric-faced panels

Tool has 2 carbide inserts that bore clean holes through fibrous material with knifelike slicing action. Cutting edge of insert is curved, with plane inner surface at 30 degree angle to tool axis. Drill press or hand-held drill can be used to hold cutting tool.

Peterson, S. A.↗

Noncontaminating technique for making holes in existing process systems

Technique is developed for making cleanly-contoured holes in assembled process systems without introducing chips or other contaminants into system. Technique uses portable equipment and does not require dismantling of system. Method was tested on Inconel, stainless steel, ASTMA-53, and Hastelloy X in all positions.

Hecker, T. P.↗

Batse Triggered Observations of Galactic Superluminal Sources GROJ1655-40

We have analyzed multiwavelength data of galactic superluminal sources including GROJ1655-40. Currently there are thirteen X-ray binaries, in which the masses of the invisible and compact objects have been determined to be much higher than three solar masses, the well-known upper limit to the mass of a neutron star. Because no stable and compact objects are believed to exist above this limit, these compact objects are consequently considered as stellar mass black holes, though clean evidence of strong gravity effects around the assumed black holes is very rare. From optical and radio observations, their system inclination angles have been determined to range between 25 degrees and 80 degrees, but peaked between 60-70 degrees. This peak is not explained in the frame work of Newtonian gravity in these systems. However, this peak is reproduced naturally if we model the observed X-ray radiation as being produced in the accretion disks very close to the black hole horizons, where the extremely strong general and special relativistic effects, caused by the extremely strong gravity near the black hole horizons, modify the local radiation significantly as the X-rays propagate to the remote observer.

Zhang, Shuang Nan↗

Enhancement Of Water-Jet Stripping Of Foam

Improved robotic high-pressure-water-jet system strips foam insulation from parts without removing adjacent coating materials like paints, primers, and sealants. Even injects water into crevices and blind holes to clean out foam, without harming adjacent areas. Eliminates both cost of full stripping and recoating and problem of disposing of toxic solutions used in preparation for coating. Developed for postflight refurbishing of aft skirts of booster rockets. System includes six-axis robot provided with special end effector and specially written control software, called Aftfoam. Adaptable to cleaning and stripping in other industrial settings.

Cosby, Steven A.↗

Obtaining Patterns Of Holes In Directional Couplers

Technique enables reproduction of pattern of holes in hidden common wall of microwave directional coupler. Talcum-dusting procedure yields pattern of powder on adhesive tape showing sizes of distances between holes. Later, coupler cleaned with water or compressed air. Applicable to other equipment containing inaccessible holes in common wall between adjacent tubes.

Perez, Raul M.↗

Focal-Plane Arrays of Quantum-Dot Infrared Photodetectors

Focal-plane arrays of semiconductor quantum-dot infrared photodetectors (QDIPs) are being developed as superior alternatives to prior infrared imagers, including imagers based on HgCdTe devices and, especially, those based on quantum-well infrared photodetectors (QWIPs). HgCdTe devices and arrays thereof are difficult to fabricate and operate, and they exhibit large nonunformities and high 1/f (where f signifies frequency) noise. QWIPs are easier to fabricate and operate, can be made nearly uniform, and exhibit lower 1/f noise, but they exhibit larger dark currents, and their quantization only along the growth direction prevents them from absorbing photons at normal incidence, thereby limiting their quantum efficiencies. Like QWIPs, QDIPs offer the advantages of greater ease of operation, greater uniformity, and lower 1/f noise, but without the disadvantages: QDIPs exhibit lower dark currents, and quantum efficiencies of QDIPs are greater because the three-dimensional quantization of QDIPs is favorable to the absorption of photons at normal or oblique incidence. Moreover, QDIPs can be operated at higher temperatures (around 200 K) than are required for operation of QWIPs. The main problem in the development of QDIP imagers is to fabricate quantum dots with the requisite uniformity of size and spacing. A promising approach to be tested soon involves the use of electron-beam lithography to define the locations and sizes of quantum dots. A photoresist-covered GaAs substrate would be exposed to the beam generated by an advanced, high-precision electron beam apparatus. The exposure pattern would consist of spots typically having a diameter of 4 nm and typically spaced 20 nm apart. The exposed photoresist would be developed by either a high-contrast or a low-contrast method. In the high-contrast method, the spots would be etched in such a way as to form steep-wall holes all the way down to the substrate. The holes would be wider than the electron beam spots perhaps as wide as 15 to 20 nm, but may be sufficient to control the growth of the quantum dots. In the low-contrast method, the resist would be etched in such a way as to form dimples, the shapes of which would mimic the electron-beam density profile. Then by use of a transfer etching process that etches the substrate faster than it etches the resist, either the pattern of holes or a pattern comprising the narrow, lowest portions of the dimples would be imparted to the substrate. Having been thus patterned, the substrate would be cleaned. The resulting holes or dimples in the substrate would serve as nucleation sites for the growth of quantum dots of controlled size in the following steps. The substrate would be cleaned, then placed in a molecular-beam-epitaxy (MBE) chamber, where native oxide would be thermally desorbed and the quantum dots would be grown.

Gunapala, Sarath↗

Fabricating PFPE Membranes for Capillary Electrophoresis

A process has been developed for fabricating perfluoropolyether (PFPE) membranes that contain microscopic holes of precise sizes at precise locations. The membranes are to be incorporated into laboratory-on-a-chip microfluidic devices to be used in performing capillary electrophoresis. The present process is a modified version of part of the process, described in the immediately preceding article, that includes a step in which a liquid PFPE layer is cured into solid (membrane) form by use of ultraviolet light. In the present process, one exploits the fact that by masking some locations to prevent exposure to ultraviolet light, one can prevent curing of the PFPE in those locations. The uncured PFPE can be washed away from those locations in the subsequent release and cleaning steps. Thus, holes are formed in the membrane in those locations. The most straightforward way to implement the modification is to use, during the ultraviolet-curing step, an ultraviolet photomask similar to the photomasks used in fabricating microelectronic devices. In lieu of such a photomask, one could use a mask made of any patternable ultraviolet-absorbing material (for example, an ink or a photoresist).

Lee, Michael C.↗

Multifunction Vacuum Chamber for IC Metallization

Vacuum system chamber processing multilayer metallization on integrated circuits (IC's) performs four operations ordinarily done in separated equipment. Chamber etches holes, removes photoresist, cleans by sputter etching, and deposits final layer of metal. Combinedfunction chamber costs less than separate equipment. Chamber avoids exposing integrated circuits to room air and, to oxidation and dust, between steps. Eliminates time spent in transferring circuits from one apparatus to next.

Routh, D. E.↗

A Dose of Reality: Radiation Analysis for Realistic Human Spacecraft

INTRODUCTION As with most computational analyses, a tradeoff exists between problem complexity, resource availability and response accuracy when modeling radiation transport from the source to a detector. The largest amount of analyst time for setting up an analysis is often spent ensuring that any simplifications made have minimal impact on the results. The vehicle shield geometry of interest is typically simplified from the original CAD design in order to reduce computation time, but this simplification requires the analyst to "re-draw" the geometry with a limited set of volumes in order to accommodate a specific radiation transport software package. The resulting low-fidelity geometry model cannot be shared with or compared to other radiation transport software packages, and the process can be error prone with increased model complexity. The work presented here demonstrates the use of the DAGMC (Direct Accelerated Geometry for Monte Carlo) Toolkit from the University of Wisconsin, to model the impacts of several space radiation sources on a CAD drawing of the US Lab module. METHODS The DAGMC toolkit workflow begins with the export of an existing CAD geometry from the native CAD to the ACIS format. The ACIS format file is then cleaned using SpaceClaim to remove small holes and component overlaps. Metadata is then assigned to the cleaned geometry file using CUBIT/Trelis from csimsoft (Registered Trademark). The DAGMC plugin script removes duplicate shared surfaces, facets the geometry to a specified tolerance, and ensures that the faceted geometry is water tight. This step also writes the material and scoring information to a standard input file format that the analyst can alter as desired prior to running the radiation transport program. The scoring results can be transformed, via python script, into a 3D format that is viewable in a standard graphics program. RESULTS The CAD model of the US Lab module of the International Space Station, inclusive of all the racks and components, was simplified to remove holes and volume overlaps. Problematic features within the drawing were also removed or repaired to prevent runtime issues. The cleaned drawing was then run through the DAGMC workflow to prepare for analysis. Pilot tests modeling transport of 1GeV proton and 800MeV/A oxygen sources show that reasonable results are converged upon in an acceptable amount of overall computation time from drawing preparation to data analysis. The FLUKA radiation transport code will next be used to model both a GCR and a trapped radiation source. These results will then be compared with measurements that have been made by the radiation instrumentation deployed inside the US Lab module. DISCUSSION Early analyses have indicated that the DAGMC workflow is a promising toolkit for running vehicle geometries of interest to NASA through multiple radiation transport codes. In addition, recent work has shown that a realistic human phantom, provided via a subcontract with the University of Florida, can be placed inside any vehicle geometry for a combinatorial analysis. This added functionality gives the user the ability to score various parameters at the organ level, and the results can then be used as input for cancer risk models.

Barzilla, J. E.↗

Vapor Degreasing Of A Large Tank

Vapor degreasing procedure provides for removal of relatively non-volatile oils and greases from insides of large vessels. Solvent refluxed to concentrate less volatile contaminants at bottom. Procedure ensures required degrees of cleaniness in high-purity chemical processing and high-vacuum processing vessels. Devised for cleaning complexly-shaped stainless-steel vacuum chamber containing numerous difficult-to-clean features like screw holes and abutting surfaces. Solvent can be chlorofluorocarbon, if means provided to recover most and minimize portion escaping into air. Alternatively, hydrocarbon or other flammable solvent used, provided flammability tolerable in particular application.

Frazer, Robert E.↗

Plugging of cooling holes in film-cooled turbine vanes

The plugging of vane cooling holes by impurities in a marine gas turbine was closely simulated in burner rig tests where dopants were added to the combustion products of a clean fuel (Jet-A). Hole plugging occurred when liquid phases, resulting from the dopants, were present in the combustion products. Increasing flame temperature and dopant concentration resulted in an increased rate of deposition and hole plugging.

Deadmore, D. L.↗

Geothermal down well pumping system

A key technical problem in the exploitation of hot water geothermal energy resources is down-well pumping to inhibit mineral precipitation, improve thermal efficiency, and enhance flow. A novel approach to this problem involves the use of a small fraction of the thermal energy of the well water to boil and super-heat a clean feedwater flow in a down-hole exchanger adjacent to the pump. This steam powers a high-speed turbine-driven pump. The exhaust steam is brought to the surface through an exhaust pipe, condensed, and recirculated. A small fraction of the high-pressure clean feedwater is diverted to lubricate the turbine pump bearings and prevent leakage of brine into the turbine-pump unit. A project demonstrating the feasibility of this approach by means of both laboratory and down-well tests is discussed.

Matthews, H. B.↗

Analysis of the Spread Across Liquid-5 (SAL-5) Experiment Failure to Fill Properly During Flight

When a pool of flammable liquid is ignited, the flame spread rate can vary widely depending on the initial fuel temperature, pool geometry, ambient atmospheric conditions, and gravitational level. There is substantial decades-old debate in the scientific literature about the role of gravity in these phenomena. The objective of the research was to measure ignition and flame spread across liquid pools in both normal and microgravity with and without forced airflow, and to obtain detailed thermal and velocity field data for comparison to a predictive numerical model that is concurrently being developed. To that end, an experiment known as Spread Across Liquids 5 (SAL 5) was designed to be conducted in a low-gravity environment on a sounding rocket. Unfortunately, during the sounding rocket flight the fuel tray for the experiment failed to fill properly prior to ignition. The primary cause of the failure to fill properly is the geometry of the fuel tray; that is, the presence of the gaps on the side walls and the sharp edge around the thermocouple through-holes. The contamination resulting from the cleaning process is a strong secondary factor which would have prevented proper, timely filling had the primary cause not been present.

Allen, Jeffrey Stuart↗

Bonding-Compatible Corrosion Inhibitor for Rinsing Metals

A corrosion-inhibiting mixture of compounds has been developed for addition to the water used to rinse metal parts that have been cleaned with aqueous solutions in preparation for adhesive bonding of the metals to rubber and rubber-like materials. Prior to the development of this corrosion inhibitor, the parts (made, variously, of D6AC steel and 7075-T73 aluminum) were rinsed by deionized water, which caused corrosion in some places on the steel parts especially in such occluded places as sealing surfaces and threaded blind holes. An integral part of the particular cleaning process is the deposition of a thin layer of silicates and silane primers that increase the strength of the adhesive bond. The corrosion inhibitor is formulated, not only to inhibit corrosion of both D6AC steel and 7075- T73 aluminum, but also to either increase or at least not reduce the strength of the adhesive bond to be formed subsequently. The corrosion inhibitor is a mixture of sodium silicate and sodium tetraborate. The sodium silicate functions as both a corrosion inhibitor and a bond-strength promoter in association with the silane primers. The sodium tetraborate buffers the rinse solution at the optimum pH and functions as a secondary corrosion inhibitor for the steel. For a given application, the concentrations of sodium silicate and sodium tetraborate must be chosen in a compromise among the needs to inhibit corrosion of steel, inhibit corrosion of aluminum, and minimize cosmetic staining of both steel and aluminum. Concentrations of sodium silicate in excess of 150 parts of silicon per million parts of solution (ppm Si) have been determined to enhance inhibition of corrosion; unfortunately, because of the alkalinity of sodium silicate, even a small concentration can raise the pH of the rinse solution to such a level that aluminum becomes corroded despite the inhibiting effect. The pH of a solution that contains a high concentration of sodium silicate can be decreased by adding sodium tetraborate. On the other hand, the addition of sodium tetraborate increases the concentration of dissolved solids to such a high level that cosmetic staining becomes an issue.

Saunders, C. R.↗

General relativistic x ray (UV) polarization rotations as a quantitative test for black holes

It is now 11 years since a potentially easily observable and quantitative test for black holes using general relativistic polarization rotations was proposed (Stark and Connors 1977, and Connors and Stark 1977). General relativistic rotations of the x ray polarization plane of 10 to 100 degrees with x ray energy (between 1 and 100 keV) are predicted for black hole x ray binaries. (Classically, by symmetry, there is no rotation.) Unfortunately, x ray polarimetry has not been taken sufficiently seriously during this period, and this test has not yet been performed. A similar (though probably less clean) effect is expected in the UV for supermassive black holes in some quasars active galactic nuclei. Summarizing: (1) a quantitative test (proposed in 1977) for black holes exists; (2) x ray polarimetry of galactic x ray binaries sensitive to at least 1/2 percent between 1 keV and 100 keV is needed (polarimetry in the UV of quasars and AGN will also be of interest); and (3) proportional counters using timerise discrimination were shown in laboratory experiments able to perform x ray polarimetry and this and other methods need to be developed.

Stark, Richard F.↗