Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hyperion system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion

Purpose: Helium ions ({sup 4}He) may supplement current particle beam therapy strategies as they possess advantages in physical dose distribution over protons. To assess potential clinical advantages, a dose calculation module accounting for relative biological effectiveness (RBE) was developed and integrated into the treatment planning system Hyperion. Methods: Current knowledge on RBE of {sup 4}He together with linear energy transfer considerations motivated an empirical depth-dependent “zonal” RBE model. In the plateau region, a RBE of 1.0 was assumed, followed by an increasing RBE up to 2.8 at the Bragg-peak region, which was then kept constant over the fragmentation tail. To account for a variable proton RBE, the same model concept was also applied to protons with a maximum RBE of 1.6. Both RBE models were added to a previously developed pencil beam algorithm for physical dose calculation and included into the treatment planning system Hyperion. The implementation was validated against Monte Carlo simulations within a water phantom using γ-index evaluation. The potential benefits of {sup 4}He based treatment plans were explored in a preliminary treatment planning comparison (against protons) for four treatment sites, i.e., a prostate, a base-of-skull, a pediatric, and a head-and-neck tumor case. Separate treatment plans taking into account physical dose calculation only or using biological modeling were created for protons and {sup 4}He. Results: Comparison of Monte Carlo and Hyperion calculated doses resulted in a γ{sub mean} of 0.3, with 3.4% of the values above 1 and γ{sub 1%} of 1.5 and better. Treatment plan evaluation showed comparable planning target volume coverage for both particles, with slightly increased coverage for {sup 4}He. Organ at risk (OAR) doses were generally reduced using {sup 4}He, some by more than to 30%. Improvements of {sup 4}He over protons were more pronounced for treatment plans taking biological effects into account. All OAR doses were within tolerances specified in the QUANTEC report. Conclusions: The biological {sup 4}He model proposed above is a first approach matching biological data published so far. The advantage of {sup 4}He seems to lie in the reduction of dose to surrounding tissue and to OARs. Nevertheless, additional biological experiments and treatment planning studies with larger patient numbers and more tumor indications are necessary to study the possible benefits of helium ion beam therapy in detail.

60 APPLIED LIFE SCIENCES↗

Controlling Combinatorial Complexity in Software and Malware Behavior Computation

Virtually all software is out of intellectual control in that no one knows its full behavior. Software Behavior Computation (SBC) is a new technology for understanding everything software does. SBC applies the mathematics of denotational semantics implemented by function composition in Functional Trace Tables (FTTs) to compute the behavior of programs, expressed as disjoint cases of conditional concurrent assignments. In some circumstances, combinatorial explosions in the number of cases can occur when calculating the behavior of sequences of multiple branching structures. This paper describes computational methods that avoid combinatorial explosions. The predicates that control branching structures such as ifthenelses can be organized into three categories: 1) Independent, resulting in no behavior case explosion, 2) Coordinated, resulting in two behavior cases, or 3) Goaloriented, with potential exponential growth in the number of cases. Traditional FTT-based behavior computation can be augmented by two additional computational methods, namely, Single-Value Function Abstractions (SVFAs) and, introduced in this paper, Relational Trace Tables (RTTs). These methods can be applied to the three predicate categories to avoid combinatorial growth in behavior cases while maintaining mathematical correctness.

Hyperion system↗

Spatio-temporally shaped deep UV laser source for ultrabright photocathodes using novel upconversion techniques (Final Report)

The goal of this project was to take a VUV laser system designed by Kapteyn-Murnane Labs (KMLabs)—the Hyperion VUV, and increase its functionality, efficiency, and applicability by further probing the fundamental physics taking place in the system and optimizing the system performance. More specifically, DOE accelerator applications—particularly for XFELs that require low-emittance electron beams, require precisely controlled ultrashort pulses in the deep-UV at 250-260 nm to drive the photocathode electron source. This is conventionally done using an ultrafast infrared laser, with subsequent stages of nonlinear upconversion in solid-state nonlinear-optical crystal media (principally BBO, which is commonly used for UV upconversion). However, maintaining high spatial mode beam quality, as well as precisely controlled temporal profile, has proven a persistent challenge. As a possible alternative to this approach, KMLabs has demonstrated a system that generates vacuum ultraviolet light (VUV) by upconverting pulses from an infrared ultrafast laser in a gas-filled hollow waveguide, driving a process of highly cascaded harmonic generation (HCHG). Because HCHG upconversion is done in a gas, rather than a solid, at high intensity in a guided-wave geometry, it retains an excellent beam spatial profile as well as a large spectral bandwidth that allows for control over the temperal structure of the pulse. A challenge, however, is in energy scaling of this HCHG technique to the ~1-20 μJ pulses required for photocathode applications. To-date, the pulse energies used in published HCHG work are sub-10-nJ. This project proposed to explore ways to generate higher-energy pulses using HCHG, as well as to investigate spectral and temporal shaping of the deep UV pulses by pulse shaping the infrared laser used to seed the process. Although we showed that our approach works for generating light at 259 nm, the total pulse energy achieved seems limited to approximately the same value as past work. However, the techniques we investigated may well have benefits for extending this source to much shorter wavelength output.

43 PARTICLE ACCELERATORS↗

Comparison of Infrasound Wind Noise Reduction Systems for Use in Temporary Deployments

Infrasound, or low frequency sound 20 Hz, is produced by a variety of natural and anthropogenic sources. Wind also generates signals within this frequency band and serves as a persistent source of infrasonic noise. Infrasound sensors measure pressure fluctuations, which scale with the ambient density and velocity fluctuations of ground winds. Here we compare four different wind noise reduction systems, or "filters", and make recommendations for their use in temporary infrasound deployments. Our results show that there are two filters that are especially effective at reducing wind noise: (1) a Hyperion high frequency (HF) shroud with a 1 m diameter metal mesh dome placed on top and (2) a Hyperion Four Port Garden Hose shroud with 4 Miracle-Gro Soaker System garden hoses. We also find that placing a 5-gallon bucket over the HF wind shroud should not be done as it provides a negligible decrease in noise up to ~ 1 Hz and then an increase in noise. We conclude that it is up to the researcher to determine which of the other filters is best for their needs based on location and expense. We anticipate this study will be used as a resource for future deployments when a wind noise reduction method is necessary but only needed for a limited time period.

58 GEOSCIENCES↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Numerical simulations of turbulent molecular clouds regulated by radiation feedback forces. I. Star formation rate and efficiency

Radiation feedback from stellar clusters is expected to play a key role in setting the rate and efficiency of star formation in giant molecular clouds. To investigate how radiation forces influence realistic turbulent systems, we have conducted a series of numerical simulations employing the Hyperion radiation hydrodynamics solver, considering the regime that is optically thick to ultraviolet and optically thin to infrared radiation. Our model clouds cover initial surface densities between Σ{sub cl,0}∼10--300 M{sub ⊙} pc{sup −2}, with varying initial turbulence. We follow them through turbulent, self-gravitating collapse, star cluster formation, and cloud dispersal by stellar radiation. All our models display a log-normal distribution of gas surface density Σ; for an initial virial parameter α{sub vir,0}=2, the log-normal standard deviation is σ{sub lnΣ}=1--1.5 and the star formation rate coefficient ε{sub ff, ρ-bar }=0.3--0.5, both of which are sensitive to turbulence but not radiation feedback. The net star formation efficiency (SFE) ε{sub final} increases with Σ{sub cl,0} and decreases with α{sub vir,0}. We interpret these results via a simple conceptual framework, whereby steady star formation increases the radiation force, such that local gas patches at successively higher Σ become unbound. Based on this formalism (with fixed σ{sub lnΣ}), we provide an analytic upper bound on ε{sub final}, which is in good agreement with our numerical results. The final SFE depends on the distribution of Eddington ratios in the cloud and is strongly increased by the turbulent compression of gas.

79 ASTRONOMY AND ASTROPHYSICS↗

2019 Hyperion 5313A and 5119A Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated two variations of a new model of infrasound sensor, the Hyperion 5313A and 5119A. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The Hyperion infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-Term Infrasound Sensor Calibration and Characterization

Previous testing has shown that infrasound sensors deployed in the field can exhibit notable deviations from their nominal, lab-based calibrations. These variations may be due to changes in environmental conditions, long-term sensor drift, or other unresolved features. In early 2018, we installed two identical infrasound elements with five infrasound sensors at each element (Chaparral M50A, Chaparral M64LN, CEA/Martec MB2005, CEA/Seismowave MB3a, and Hyperion IFS-5113A). These sensors were accepted or under consideration for use in the International Monitoring System network of the Comprehensive Nuclear-Test-Ban Treaty. Each element had all sensors connected to a single digitizer and port to the atmosphere. We also recorded instrument enclosure air temperature and humidity and external air temperature. Using the MB2005 as the reference, we examine the relative sensor response (both magnitude and phase) as a function of time and frequency and compare it with quarterly laboratory calibrations and environmental conditions. Here, we find that the magnitude response for all sensors exhibits some variability in both the lab and field, with the amplitude variations often >5%. The field-based variations are more severe and occur on both long-term (months) and short-term (hours) timescales. Short-term variability correlates with changes in environmental conditions and is considerable (up to 25%) for the Chaparral M50A and noticeable (∼5%) for the French Alternative Energies and Atomic Energy Commission (CEA) MB3a. Long-term magnitude variability for the Chaparral M50A was up to 50% and does not clearly correlate with environmental conditions. The other sensors show some long-term magnitude offsets, but they have relatively stable responses in the conditions we examined. The MB3a also displays some frequency-dependent magnitude variability and shows a minor dependence on temperature. Phase estimates are stable and near zero for all sensors tested. These results strongly suggest sensor response and variability due to environmental conditions should be considered in future infrasound data interpretation and sensor selection and development.

Fee, David↗

Hyperion 5113/A Infrasound Sensor Evaluation

Sandia National Laboratories has tested and evaluated an infrasound sensor, the 5113/A manufactured by Hyperion. These infrasound sensors measure pressure output by a methodology developed by the University of Mississippi. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, and dynamic range. The 5113/A infrasound sensor is a new revision of the 5000 series intended to meet the infrasound application requirements for use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Maximum likelihood positioning algorithm for high-resolution PET scanners

Purpose: In high-resolution positron emission tomography (PET), lightsharing elements are incorporated into typical detector stacks to read out scintillator arrays in which one scintillator element (crystal) is smaller than the size of the readout channel. In order to identify the hit crystal by means of the measured light distribution, a positioning algorithm is required. One commonly applied positioning algorithm uses the center of gravity (COG) of the measured light distribution. The COG algorithm is limited in spatial resolution by noise and intercrystal Compton scatter. The purpose of this work is to develop a positioning algorithm which overcomes this limitation. Methods: The authors present a maximum likelihood (ML) algorithm which compares a set of expected light distributions given by probability density functions (PDFs) with the measured light distribution. Instead of modeling the PDFs by using an analytical model, the PDFs of the proposed ML algorithm are generated assuming a single-gamma-interaction model from measured data. The algorithm was evaluated with a hot-rod phantom measurement acquired with the preclinical HYPERION II {sup D} PET scanner. In order to assess the performance with respect to sensitivity, energy resolution, and image quality, the ML algorithm was compared to a COG algorithm which calculates the COG from a restricted set of channels. The authors studied the energy resolution of the ML and the COG algorithm regarding incomplete light distributions (missing channel information caused by detector dead time). Furthermore, the authors investigated the effects of using a filter based on the likelihood values on sensitivity, energy resolution, and image quality. Results: A sensitivity gain of up to 19% was demonstrated in comparison to the COG algorithm for the selected operation parameters. Energy resolution and image quality were on a similar level for both algorithms. Additionally, the authors demonstrated that the performance of the ML algorithm is less prone to missing channel information. A likelihood filter visually improved the image quality, i.e., the peak-to-valley increased up to a factor of 3 for 2-mm-diameter phantom rods by rejecting 87% of the coincidences. A relative improvement of the energy resolution of up to 12.8% was also measured rejecting 91% of the coincidences. Conclusions: The developed ML algorithm increases the sensitivity by correctly handling missing channel information without influencing energy resolution or image quality. Furthermore, the authors showed that energy resolution and image quality can be improved substantially by rejecting events that do not comply well with the single-gamma-interaction model, such as Compton-scattered events.

60 APPLIED LIFE SCIENCES↗

Electronic Spin Relaxation and Clustering in High-Pressure High-Temperature Synthesized Microcrystalline Diamond Particles with Reduced Nitrogen Content

The negatively charged nitrogen-vacancy (NV – ) color center in diamonds is widely studied because of numerous applications of this unique quantum system in sensing and quantum information sciences. While substitutional nitrogen is required to form the NV – centers in diamond, it also yields other paramagnetic defects─primarily the neutrally charged substitutional nitrogen centers (P1)─that decrease NV – spin coherence, which in turn degrades performance in applications. Herein, we investigate high-pressure high-temperature synthesized diamond microparticles (ca. 140–185 μm) having lower─ranging from 3 to 38 ppm─than the typical nitrogen content of type 1b diamond ( ca. 100 ppm and higher) typically used for the production of fluorescent diamond particles with NV – centers. A suite of electron paramagnetic resonance, optically detected magnetic resonance, and nuclear magnetic resonance methods are used to characterize spin properties of P1 and NV – centers in the particles. Upon decreasing the nitrogen content from 29 to 3 ppm, the ensemble NV – T 2 relaxation time increased by about 3-fold as measured directly in the Hahn Echo experiment at magnetic field of 1.2 T. Analysis of electronic relaxation of P1 centers revealed the existence of at least two distinct populations of P1 centers, consisting of fast and slower relaxing spins and allowed for an estimation of local concentrations. Even with <10 ppm nitrogen contents, the analysis indicated a highly heterogeneous distribution of P1 centers, suggesting the possibility of P1 spin clustering even at low nitrogen concentrations. The combined data demonstrate that the particles prepared from HPHT diamond with a low nitrogen content offer improved spin properties that are beneficial for NV – sensing applications.

Carbon↗