Search NASA⌕ Search

SEARCH · Search NASA

Results for “ICP MS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS

Single particle - inductively coupled plasma - mass spectrometry (SP-ICP-MS) is a powerful technique for characterization of the elemental and isotopic composition of individual particles. In this work, the capabilities of the newest generation of MC-ICP-MS with acquisition rates down to 50 ms were evaluated for single particle analysis, with a focus on isotopic precision achievable on a single-particle level. Nd (NdVO 4 ) nanoparticles (~120 nm in diameter) were used as case study and were first characterized in terms of mass (respective size) and particle number concentration by SP-ICP-TOF-MS and then by SP-MC-ICP-MS for isotopic precision. For the isotopic ratio measurements, the MC-ICP-MS performance was compared to the ICP-TOF-MS and it was found that the isotope ratio precision was increased (R 2 between 0.98 and 0.99) compared to ICP-TOF-MS (R 2 between 0.88 and 0.97). The accuracy attained on a single particle level, was compared to bulk digestion followed by MC-ICP-MS analysis, and the SP-MC-ICP-MS technique was able to determine the particle population average to be <4 %, percent relative differences for the 142 Nd/ 144 Nd, 143 Nd/ 144 Nd, 145 Nd/ 144 Nd, 146 Nd/ 144 Nd, and 148 Nd/ 144 Nd ratios The detection limit for the SP-MC-ICP-MS approach was also assessed. Here, when utilizing an all Faraday-cup based detection scheme the determined LOD for the measurements was 0.2fg for Nd, per particle. Based on these results, the newest generation of MC-ICP-MS has demonstrated its utility for performing SP measurement, particularly when high precision isotopic determination is warranted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Rapid analysis of 237 Np and Pu isotopes in unseparated sample matrices using ICP-MS/MS

Inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is an emerging technique for measuring actinide isotopes when assessing pre- and post- detonation nuclear material. In this study, ICP-MS/MS was investigated for direct Np and Pu quantitation in unseparated, dissolved bulk soil matrices. To achieve this, purified nitric oxide (NO) was investigated for the reactivity of Th, Np, U, Pu, Am, and Cm. Purifying NO prior to the collision reaction cell (CRC) results in increased sensitivity and allows for higher gas flows to be utilized for the removal of interferences. Here, the interference from uranium hydrides was mitigated to less than 3.85 x 10 -11 . This method was demonstrated on standard reference materials which were measured for 237 Np and 238,239,240 Pu in dilute sample digestions. The 238 Pu measurement was validated by spiking into a standard reference material and was accurately measured with an excess of 85000 of 238 U.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of gas purity on backgrounds of collision reaction cell-equipped MC-ICP-MS

The advent of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) instruments equipped with collision reaction cells (CRCs) facilitates interference removal/mitigation via online gas phase separations. This approach has proven effective for high intensity ion beams measured on Faraday collectors; however, it has been observed that introduction of gas in the CRC can result in significant background signals relative to the more sensitive ion counters. These backgrounds hinder use of these instruments for low level concentration and isotopic ratio measurements when employing a reaction gas. Here, this work directly evaluates the effect of gas purity on backgrounds of CRC-MC-ICP-MS instruments. Introducing high-purity research grade O 2 (99.999%) into the CRC produces complex background spectra with intensities >10 4 cps observed at most masses across the measured mass range (7-300 m / z ). Some features of the observed spectra (i.e., positive mass defects) can be attributed to molecular compounds comprised of significant hydrogen. Additionally, some specific molecular species can be identified (i.e., MoO x H y + ) and appear to be derived from molybdenum rods comprising the CRC. Further purifying the gas reduces the intensity of these backgrounds by several orders of magnitude, to <10 2 cps in many cases, and reduces complexity of the resulting spectra. This reduction in background appears to be in part driven by removal of impurities (i.e., H 2 O) from the gas. This work demonstrates that additional purification of reaction gases prior to introduction into the CRC significantly reduces backgrounds detected, potentially expanding the utility of CRC-MC-ICP-MS for making low level measurements using inline gas phase ion separations.

Schlieder, Tyler D. [Pacific Northwest National La↗

Exploration of a Combined LIBS and LA-ICP-MS Approach for Apatite Characterisation

A combined laser‐induced breakdown spectroscopy (LIBS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) method is demonstrated for comprehensive apatite analysis. These measurements provide elemental imaging that can be used as a screening technique for chemical selection of grains for subsequent analysis (e.g., U‐Pb geochronology) or can be used to understand elemental distributions within a single grain that would have direct textural‐chemical implications (e.g., zoning patterns). Adding LIBS as a simultaneous measurement, to LA‐ICP‐MS U‐Pb geochronology, allowed for the direct determination of F (H and O show promise for future applications) in addition to major and trace elements of interest. Here, the quantitative measurements were validated against a series of apatites with known values and used to characterise a wide range of samples. Fluorine detection limits were determined to be as low as 70 μg g ‐1 F (broadband CMOS detector) and 4.2 μg g ‐1 F (ICCD detector). U‐Pb age dating was simultaneously collected by LA‐ICP‐MS with the quantitative elemental data from LIBS, providing a comprehensive method for geochronology.

Apatite↗

Development of a Flow-through Cell for Ultrasonic Extraction (UE)─Single Particle (SP)─ICP-MS─an Approach for Nano/Microparticle Elemental and Isotopic Analysis

Nanotechnology is a salient part of the scientific landscape, and analytical approaches are rapidly evolving to enable small-scale characterization of nano- and microparticle compositions and impurities. Here, a flow-through sonicating cell was developed for direct particle extraction from a silicon wafer and integrated with an inductively coupled plasma–mass spectrometer (ICP-MS) for subsequent elemental and isotopic characterization of the released particles. Ultrasonic extraction (UE)─single particle (SP)─ICP-MS offers controlled particle mobilization from solid substrates and allows for increased sample throughput by eliminating the need for pre-extraction of particles and decreasing sample preparation steps. Coupling this device to an ICP-MS with a time-of-flight (TOF) mass analyzer, it is possible to distinguish unique isotopic compositions of the particles. Both tungsten and nickel isotopically tagged particles, which were deposited on Si wafers, are presented here with analysis via UE─SP─ICP-MS. This approach could support efforts in the fields of particle synthesis, nuclear safeguards and forensics, environmental monitoring, and semiconductor industries in which the detection of particles from substrates and wafers is critical.

Paul, Molly [ORNL] (ORCID:0009000009672055)↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Chemistry imaging and distribution analysis of rare earth elements in coal using LIBS and LA-ICP-MS instruments

Currently, demand for rare earth elements (REEs) increased significantly. Coal is actively evaluated as potential economic sources for extraction of REEs. Here, in this work, laser-induced breakdown spectroscopy (LIBS) was evaluated for rapid estimation of REEs content and their distribution in the natural coal samples. The results were compared with similar laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) measurements. Thirteen coal samples (nine standard samples and five natural samples) were used in this study. Powder samples were pressed into pellets while coal chunks were directly ablated for data recording. Pellets of the powder standard samples were used to optimize the data acquisition system and then data recorded with this optimized system was used to identify the proper data acquisition and analysis models. After establishing the proper data acquisition system and analysis model using the standard samples, natural coal samples in powder form and their chunks were utilized to record LIBS and LA-ICP-MS spectra. Multivariate calibration models were developed using four of the natural samples, which were evaluated by predicting the REE content in the fifth sample. Principal component analysis was performed on the LIBS data obtained from the natural samples and it classified all the samples with high accuracy. Two-dimensional (2D) elemental mapping on coal chunk samples was also performed using both LIBS and LA-ICP-MS to study the distribution of REEs in the samples. The resulting elemental images and their correlations can be used to infer mineral distributions.

01 COAL, LIGNITE, AND PEAT↗

Boron isotopic analysis in bulk silicate materials using the Neoma MS/MS MC-ICP-MS

Boron (B) isotopes are a valuable tracer with applications ranging from geological, environmental, and nuclear studies because B isotopic fractionation is highly sensitive to chemical processes yielding distinct isotopic trends in natural and anthropogenic systems. Despite this wide applicability, there remain relatively few measurements on well-described reference materials and in some cases, poor agreement between various methods. We report a method for boron isotope ratio measurement in solution on the Neoma MS/MS MC-ICP-MS specifically targeting bulk silicates. We evaluate the performance of the method and instrument as it relates to the measurement of the absolute boron isotope ratio ( 10 B/ 11 B). The results indicate that the method produces data in agreement with literature values and that the sample–standard bracketing technique is appropriate for the Neoma MS/MS MC-ICP-MS which has been in use for decades on previous generation instruments. Careful tuning of the MS/MS lenses is required to obtain precision comparable to non MS/MS equipped MC-ICP-MS. With careful tuning, internal and external precisions of ∼0.3‰ were achieved. However, when the MS/MS is not properly tuned external precisions exceed 3‰. Nevertheless, our results for IAEA B-6, BCR-2, BHVO-2 and W-2a reference materials overlap the 1σ range of previously reported 10 B/ 11 B. Data are reported for total boron quantities down to a few tens of nanograms. Our procedure yielded blanks as low as 3 ng but up to 29 ng, making blank corrections important for small samples sizes in the few 10s of nanogram range. We report B isotope ratios for AGV-2G, SL-1G, GSC-2G, GSD-2G, GSE-2G, RLS-132, RLS-140, NKT-1G, and T1-G glass reference materials that have not been previously reported in the literature.

Scott, Sean R. [Pacific Northwest National Laborat↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Online collection of LC effluent as droplets for automatic injection into ICP-MS

A sample introduction technique was developed to allow for online, dropwise injection of effluent into a mass spectrometer (MS). This allowed for the coupling of chromatography systems that were not driven by pumps without altering the set-up or separation performance. This capability combined the benefits of coupling separation and measurement while also enabling accurate chromatographic evaluation that would generally be performed offline. The incorporation of a flowing rinse into the system made dropwise resolution possible for any liquid capable of forming drops under ambient conditions. The technique was demonstrated utilizing gas pressurized extraction chromatography (GPEC) and inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) to illustrate the qualitative applications for rapid separation development and procedure evaluation. This method's quantitative applications were evaluated using single and double isotope dilution mass spectrometry (IDMS) with an external mass bias correction to measure analytes across entire elutions including volumes as small as single drops. In conclusion, the total neodymium values afforded by both single and double IDMS were within the uncertainty of the calculated value for evaluation of full elution peaks and for most of the single drops analyzed that reached above 10k cps Nd-144.

GPEC↗

The Curious Case of Pu + : Insight on 5f Orbital Activity from Inductively Coupled Plasma Tandem Mass Spectrometry (ICP-MS/MS) Reactions

A comprehensive understanding of when and how 5f orbitals participate in complex chemical bonding is important for a variety of applications. The actinides are unique in that they possess 5f orbitals and can access high oxidation states, which make them attractive for use in catalysis. Fundamental studies of actinide–ligand interactions offer a mechanism to examine the activation of the 5f orbitals so that the selectivity of 5f orbitals can be assessed. A previous study examined the reaction of Pu + + CO 2 and determined that the reaction efficiency is restricted by a barrier, namely, promotion from the Pu + ground-state configuration, 5f 6 7s, to a reactive-state configuration, 5f 5 6d 2 . Here, the present study illustrates the benefit of activation of Pu’s 5f orbitals when studying the reaction of Pu + + NO. In this reaction, PuO + forms in an exothermic, barrierless process. The 5f orbitals can and do participate in forming a linear intermediate, [N-Pu-O] + , and this drives the exothermic reaction. Understanding the conditions under which 5f orbitals are active in chemical bonding is the key to exploiting the actinides’ selective catalytic capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithium isotope analysis on the Neoma MS/MS MC-ICP-MS

Accurate and precise lithium isotopic composition measurements are achieved on the Neoma MS/MS after careful tuning of the prefilter lenses to allow both Li ion beams to pass through unimpeded.

07 ISOTOPE AND RADIATION SOURCES↗