Search NASA⌕ Search

SEARCH · Search NASA

Results for “INFANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Advanced Infant Car Seat Would Increase Highway Safety

An advanced infant car seat has been proposed to increase highway safety by reducing the incidence of crying, fussy behavior, and other child-related distractions that divert an adult driver s attention from driving. In addition to a conventional infant car seat with safety restraints, the proposed advanced infant car seat would include a number of components and subsystems that would function together as a comprehensive infant-care system that would keep its occupant safe, comfortable, and entertained, and would enable the driver to monitor the baby without having to either stop the car or turn around to face the infant during driving. The system would include a vibrator with bulb switch to operate; the switch would double as a squeeze toy that would make its own specific sound. A music subsystem would include loudspeakers built into the seat plus digital and analog circuitry that would utilize plug-in memory modules to synthesize music or a variety of other sounds. The music subsystem would include a built-in sound generator that could synthesize white noise or a human heartbeat to calm the baby to sleep. A second bulb switch could be used to control the music subsystem and would double as a squeeze toy that would make a distinct sound. An anti-noise sound-suppression system would isolate the baby from potentially disturbing ambient external noises. This subsystem would include small microphones, placed near the baby s ears, to detect ambient noise. The outputs of the microphone would be amplified and fed to the loudspeakers at appropriate amplitude and in a phase opposite that of the detected ambient noise, such that the net ambient sound arriving at the baby s ears would be almost completely cancelled. A video-camera subsystem would enable the driver to monitor the baby visually while continuing to face forward. One or more portable miniature video cameras could be embedded in the side of the infant car seat (see figure) or in a flip-down handle. The outputs of the video cameras would be transmitted by radio or infrared to a portable, miniature receiver/video monitor unit that would be attached to the dashboard of the car. The video-camera subsystem can also be used within transmission/reception range when the seat was removed from the car. The system would include a biotelemetric and tracking subsystem, which would include a Global Positioning System receiver for measuring its location. This subsystem would transmit the location of the infant car seat (even if the seat were not in a car) along with such biometric data as the baby s heart rate, perspiration rate, urinary status, temperature, and rate of breathing. Upon detecting any anomalies in the biometric data, this subsystem would send a warning to a paging device installed in the car or carried by the driver, so that the driver could pull the car off the road to attend to the baby. A motion detector in this subsystem would send a warning if the infant car seat were to be moved or otherwise disturbed unexpectedly while the infant was seated in it: this warning function, in combination with the position- tracking function, could help in finding a baby who had been kidnapped with the seat. Removable rechargeable batteries would enable uninterrupted functioning of all parts of the system while transporting the baby to and from the car. The batteries could be recharged via the cigarette-lighter outlet in the car or by use of an external AC-powered charger.

Dabney, Richard↗

Melatonin concentrations in the sudden infant death syndrome

The melatonin levels in various body fluids of the sudden infant death syndrome (SIDS) infants are compared with those of infants of comparable age who died of other causes to examine a possible relationship between pineal function and SIDS. After adjusting for age differences, cerebrospinal fluid melatonin levels are found to be significantly lower in the SIDS infants. It is suggested that diminished melatonin production may be characteristic of SIDS and could represent an impairment in the maturation of physiologic circadian organization.

Sturner, W. Q.↗

The Golden Canopies (Infant Radiant Warmer)

The cradle warmer is based on technology in heated transparent materials developed by Sierracin Corporation, Sylmar, California he original application was in heated faceplates for the pressure suit heated faceplates worn by pilots of an Air Force/NASA reconnaissance and weather research plane. Later, Sierracin advanced the technology for other applications, among them the cockpit windows of the NASA X-15 supersonic research vehicle and the helmet faceplates of Apollo astronauts. Adapting the technology to hospital needs, Sierracin teamed with Cavitron Corporation, Anaheim, California, which produces the cradle warmer and two other systems employing Sierracin's electrically-heated transparencies. Working to combat the infant mortality rate, hospitals are continually upgrading delivery room and nursery care techniques. Many have special procedures and equipment to protect infants during the "period of apprehension," the critical six to 12 hours after delivery. One such item of equipment is an aerospace spinoff called the Infant Radiant Warmer, a "golden canopy" which provides uniform, controlled warmth to the infant's cradle. Warmth is vitally important to all newborns, particularly premature babies; they lose heat more rapidly than adults because they have greater surface area in comparison with body mass.

Source record↗

Metabolic studies of transient tyrosinemia in premature infants

The recently developed technique of gas chromatography-mass spectrometry supported by computer has considerably improved the analysis of physiologic fluids. This study attempted to demonstrate the value of this system in the investigation of metabolite patterns in urine in two metabolic problems of prematurity, transient tyrosinemia and late metabolic acidosis. Serial 24-hr urine specimens were analyzed in 9 infants. Transient tyrosinemia, characterized by 5- 10-fold increases over basal excretion of tyrosine, p-hydroxyphenyllactate, and p-hydroxyphenylpyruvate in urine, was noted in five of the infants. Late metabolic acidosis was seen in four infants, but bore no relation to transient tyrosinemia.

Fernbach, S. A.↗

Melatonin concentrations in the sudden infant death syndrome

To examine a possible relationship between pineal function and the sudden infant death syndrome (SIDS), samples of whole blood, ventricular cerebrospinal fluid (CSF) and/or vitreous humor (VH) were obtained at autopsy from 68 infants (45 male, 23 female) whose deaths were attributed to either SIDS (n = 32, 0.5-5.0 months of age; mean plus or minus S.E.M., 2.6 plus or minus 0.2 months) or other causes (non-SIDS, n = 36, 0.3-8.0 months of age 4.3 plus or minus 0.3 months). The melatonin concentrations were measured by radioimmunoassay. A significant correlation was observed for melatonin levels in different body fluids from the same individual. After adjusting for age differences, CSF melatonin levels were significantly lower among the SIDS infants (91 plus or minus 29 pmol/l; n = 32) than among those dying from other causes (180 plus or minus 27; n = 35, P less than 0.05). A similar, but non-significant trend was also noted in blood (97 plus or minus 23, n = 30 vs. 144 plus or minus 22 pmol/l, n = 33) and vitreous humor (68 plus or minus 21, n = 10 vs. 81 plus or minus 17 pmol/l, n = 15). These differences do not appear to be explainable in terms of the interval between death and autopsy, gender, premortem infection, or therapeutic measures instituted prior to death. Diminished melatonin production may be characteristic of SIDS and could represent an impairment in the maturation of physiologic circadian organization.

Sturner, W. Q.↗

Individual recognition between mother and infant bats (Myotis)

The recognition process and the basis for that recognition, in brown bats, between mother and infant are analyzed. Two parameters, ultrasonic communication and olfactory stimuli, are investigated. The test animals were not allowed any visual contact. It was concluded that individual recognition between mother and infant occurred. However, it could not be determined if the recognition was based on ultrasonic signals or olfactory stimuli.

Turner, D.↗

Brain stem auditory evoked responses in human infants and adults

Brain stem evoked potentials were recorded by conventional scalp electrodes in infants (3 weeks to 3 years of age) and adults. The latency of one of the major response components (wave V) is shown to be a function both of click intensity and the age of the subject; this latency at a given signal strength shortens postnatally to reach the adult value (about 6 msec) by 12 to 18 months of age. The demonstrated reliability and limited variability of these brain stem electrophysiological responses provide the basis for an optimistic estimate of their usefulness as an objective method for assessing hearing in infants and adults.

Hecox, K.↗

Obstetrical Forceps Would Limit Force On An Infant's Head

Improved obstetrical forceps proposed to reduce injuries to newborn infants. Fabricated mostly of thermoplastic material. Reinforcing fibers added in hinge region of forceps. Combination of material, size, and shape chosen to make forceps yield elastically by amount keeping applied force from rising beyond maximum allowable value. Fiber-optic sensors for measuring strains embedded in forceps. Strain measurements used to compute tensile and compressive forces applied to infant's head.

Smeltzer, Stan↗

Orientational anisotropy in infant vision

Infants prefer to look at horizontal and vertical gratings rather than at oblique gratings only when they are at or near threshold spatial frequencies, as would be expected if acuity for oblique edges is lower than that for horizontal and vertical edges. That such a bias exists as early as 6 weeks of age suggests that the orientational asymmetry of the visual system depends on endogeneous maturation rather than exposure to a carpentered world.

Cohen Leehey, S.↗

Infant Transport Monitoring

The photo sequence illustrates the movement of an ill infant to a special care hospital by means of a new Pediatric Monitoring and Transport System, in which NASA technology and technical assistance are being applied to an urgent medical problem. Development of the system is a collaborative effort involving several organizations, principally, NASA Ames Research Center and Children's Hospital Medical Center, Oakland, California. Key to the system's efficacy is a custom-designed ambulance-to-hospital and hospital-to-hospital communications network, including two-way voice capability and space-derived biotelemetry; it allows a specialist at the destination hospital to monitor continuously the vital signs of the patient during transit.

Source record↗

Infant Mortality and Wear-Out Failures in Polymer and MnO2 Tantalum Capacitors

Reliability testing of modern tantalum capacitors shows the presence of both types, infant mortality (IM) and wearout (WO) failures. To assure reliable operation, the probability of IM failures should be reduced to below the specified level, and the time of WO inception should be greater than the required useful life of the parts at operation conditions. In this work, several types of MnO2 and polymer cathode tantalum capacitors have been tested at highly accelerated conditions to assess voltage acceleration factors, determine adequate burn-in conditions, and assess the useful life. A modified time dependent dielectric breakdown (TDDB) model has been suggested to explain both types of failure, and a physical mechanism of degradation that is based on migration and reactions of oxygen vacancies explains increase of the defect related, IM failures with the level of stress.

tantalum capacitors↗

An Examination of the U.S. Regional Airline Policies Regarding Child Restraint Systems

A prior study examined the policies of U.S. air carriers with regard to the use of infant restraint systems on board commercial aircraft. This study expands on that earlier study by examining the policies of commuter air carriers in the United States regarding the use of infant restraint systems. The management policy of the commuter air carriers has been investigated and officials of the commuter air carriers were surveyed to determine how the carriage of infants onboard their aircraft varied among commuter airlines. The topics investigated included seat space for infants, restraint systems for infants, and amenities for infant passengers. The results of this study have been analyzed to ascertain if any recommendations can be made to the commuter airlines regarding the carriage of infants onboard their aircraft.

Carstenson, Larry↗

Paramyxovirus Infection Mimics In Vivo Cellular Dynamics in Three-Demensional Human Bronchio-Epithelial Tissue-Like Assemblies

Respiratory syncytial virus and parainfluenza virus cause severe respiratory disease, especially in infants, children and the elderly. An in vitro model that accurately mimics infection of the human respiratory epithelium (HRE) would facilitate vaccine development greatly. Monolayer cultures traditionally used to study these viruses do not accurately and precisely differentiate the replication efficiencies of wild type and attenuated viruses. Therefore, we engineered novel three-dimensional (3D) tissue-like assemblies (TLAs) of human broncho-epithelial (HBE) cells to produce a more physiologically relevant in vitro model of the HRE. TLAs resemble HRE structurally and by expression of differentiated epithelial cell markers. Most significantly, wild type viruses exhibited a clear growth advantage over attenuated strains in TLAs unlike monolayer cultures. In addition, the TLAs responded to virus infection by secreting pro-inflammatory mediators similar to the respiratory epithelia of infected children. These characteristics make the TLA model a valuable platform technology to develop and evaluate live, attenuated respiratory virus vaccine candidates for human use. Respiratory virus diseases, the most frequent and least preventable of all infectious diseases, range in severity from the common cold to severe bronchiolitis and pneumonia . Two paramyxoviruses, respiratory syncytial virus (RSV) and parainfluenza virus type 3 (PIV3), are responsible for a majority of the most severe respiratory diseases of infants and young children. RSV causes 70% of all bronchiolitis cases and is a major cause of morbidity and mortality worldwide, especially in infants. PIV3 causes 10-15% of bronchiolitis and pneumonia during infancy, second only to RSV, and 40% of croup in infants To date, licensed vaccines are not available to prevent these respiratory diseases. At present, traditional monkey kidney (Vero and LLC-MK2) and human (HEp-2) tissue culture cells and small animal models (mouse, cotton rat, guinea pig, ferret, and hamster) fail to accurately imitate viral replication and human disease states (8). Lacking an authentic model has impeded the development and evaluation of live, attenuated vaccine candidates. Development of a physiologically relevant in vitro tissue culture model that reproduces characteristics of the HRE, the primary target of RSV and PIV3, would aid in predicting clinical attenuation and safety of vaccine candidates. Successful tissue engineering of a 3D human intestinal model using novel NASA technology inspired the development of a tri-culture 3D model for the HRE. Sequential layering of primary mesenchymal cells (comprised of normal human fibroblasts and endothelial cells) followed by BEAS-2B epithelial cells derived from human bronchi and tracheae were recapitulated on Cultisphere and/or cytodex3 microcarriers in cylindrical vessels that rotate horizontally creating an organized epithelial structure. Horizontal rotation randomizes the gravity vector modeling aspects of microgravity. Mesenchymal and epithelial cells grown under these conditions reproduce the structural organization, multi-cellular complexity, and differentiation state of the HRE. The opportunity to study respiratory viruses in a nasal epithelium model is invaluable because the most promising respiratory virus vaccine candidates are live attenuated viruses for intranasal administration. Here we characterize the interactions of respiratory viruses and epithelial cells grown under modeled microgravity in comparison to gravity-ladened monolayers. 3D HBE TLAs and traditional monolayers (2D) are infected at 35 C, the upper temperature of the upper HRE, to simulate in vivo infection conditions. Growth kinetics of wild type (wt) RSV and PIV3 viruses were compared in 2D and 3D cells to that of strains attenuated in humans or rhesus macaques. This novel 3D HBE model also offers an opportunity to study whether the epithelial cell function, especially in host defenses recapitulated by mimicking the structural organization of the HRE. In vivo, airway epithelial cells play a significant and dynamic role in host defense by blocking paracellular permeability and modulating airway function through cellular interactions or tight junctions. As regulators of the innate immune response, epithelial cells constitutively express cytokines, chemokines, and colony stimulating factors including RANTES, IL-8, IL-6, GM-CSF, and G-CSF for proactive host defense. In response to viral infection, epithelial cells induce potent immuno-modulatory and pro-inflammatory cytokines that recruit phagocytic and inflammatory cells to clear the virus and enhance protection. Although disease pathogenesis is classically attributed to the cytopathic effects of the pathogen, severe disease states associated with RSV and PIV3 are attributed to the inflammatory response, especially in infants. RSV is a potent inducer of cytokines and pro-inflammatory mediators in epithelial cells in vivo. A differentiated human epithelial model independent of the complete functional immune system will help elucidate the role of epithelial cells in respiratory disease. We reported here, virus and host cell interactions in 3D HBE TLAs are similar to that in vivo. Because the epithelial cell organization of the TLAs impacts not only the expression of airway epithelial characteristics, but also cellular communication, the TLAs represent a more physiologically relevant model of the HRE than BEAS-2B or other non-tumour monolayer models of respiratory disease. As a result, wild type respiratory viruses have a clear growth advantage over attenuated viruses in TLAs unlike traditional monolayers. In addition, the TLAs respond to wild type virus infection by secreting pro-inflammatory mediators characteristic of infected HRE. TLAs expressing microbial defense mechanisms provide an excellent model to study the interactions of respiratory pathogens with their host and to identify the innate immunity mediators. Therefore, 3D HBE TLAs offer advantages for the study of respiratory viruses and the development of viral vaccine candidates.

Deatly, Anne M.↗

Composite redesign of obstetrical forceps

Due to the increase in the number of children being born recently, medical technology has struggled to keep pace in certain areas. In these areas, particular needs have arisen to which the subject of this paper is directed. In the area of obstetrics, the forceps design and function has remained relatively unchanged for a number of years. In an effort to advance the technology, NASA Marshall Space Flight Center has been asked by the obstetrical community to help in a redesign of the obstetric forceps. Traditionally the forceps design has been of tubular stainless steel, constructed in two halves which interlock and hinge to provide the gripping force necessary to aid in the delivery of an infant. The stainless steel material was used to provide for ease of cleaning and sterilization. However, one of the drawbacks of the non-flexible steel design is that excessive force can be placed upon an infants head which could result in damage or injury to the infant. The redesign of this particular obstetric tool involves applying NASA's knowledge of advanced materials and state of the art instrumentation to create a tool which can be used freely throughout the obstetrics community without the fear of injury to an infant being delivered.

Lawson, Seth W.↗

Respiratory Distress

The University of Miami School of Medicine asked the Research Triangle Institute for assistance in improvising the negative pressure technique to relieve respiratory distress in infants. Marshall Space Flight Center and Johnson Space Center engineers adapted this idea to the lower-body negative-pressure system seals used during the Skylab missions. Some 20,000 babies succumb to respiratory distress in the U.S. each year, a condition in which lungs progressively lose their ability to oxygenate blood. Both positive and negative pressure techniques have been used - the first to force air into lungs, the second to keep infant's lungs expanded. Negative pressure around chest helps the baby expand his lungs and maintain proper volume of air. If doctors can keep the infant alive for four days, the missing substance in the lungs will usually form in sufficient quantity to permit normal breathing. The Skylab chamber and its leakproof seals were adapted for medical use.

Source record↗

Baby Solar System

What did our solar system look like in its infancy,...... when the planets were forming? We cannot travel back in time to take an image of the early solar system, but in principle we can have the next best thing: images of infant planetary systems around Sun-like stars with ages of 1 to 5 million years, the time we think it took for the giant planets to form. Infant exoplanetary systems are critically important because they can help us understand how our solar system fits within the context of planet formation in general. More than 80% of stars are born with gas- and dust-rich disks, and thus have the potential to form planets. Through many methods we have identified more than 760 planetary systems around middle-aged stars like the Sun, but many of these have architectures that look nothing like our solar system. Young planetary systems are important missing links between various endpoints and may help us understand how and when these differences emerge. Well-known star-forming regions in Taurus, Scorpius. and Orion contain stars that could have infant planetary systems. But these stars are much more distant than our nearest neighbors such as Alpha Centauri or Sirius, making it extremely challenging to produce clear images of systems that can reveal signs of recent planet formation, let alone reveal the planets themselves. Recently, a star with the unassuming name LkCa 15 may have given us our first detailed "baby picture" of a young planetary system similar to our solar system. Located about 450 light-years away in the Taurus starforming region. LkCa 15 has a mass comparable to the Sun (0.97 solar mass) and an age of l to 5 million years, comparable to the time at which Saturn and perhaps Jupiter formed. The star is surrounded by a gas-rich disk similar in structure to the one in our solar system from which the planets formed. With new technologies and observing strategies, we have confirmed suspicions that LkCa 15's disk harbors a young planetary system.

Currie, Thayne↗