Photo-cleaned Backgroundless Ion Chambers (Final Report for PDRD SR18010)

Ion chambers are often employed to measure the concentration of tritium within flowing gases. In real world environments the active surfaces of ion chambers become covered with tritiated surface contaminants. This tritiated surface contamination will create a large background response that can mask the signature of interest, which is the tritium concentration in the gas phase. Previous efforts to reduce the effects of surface contamination in ion chambers utilize inert coatings (e.g., gold) and low surface area electrodes (e.g., wire mesh), but this route only reduces the effect and does not necessarily alter the ratio of surface contamination to current collection area. Additionally, gold coating may add a substantial cost to the instrument. In the Tritium Facility, ion chambers are periodically cleaned using an alcohol-based process. This process is time consuming and often leads to ion chamber wear and breakage. In addition, periodic cleaning does not address tritium level ambiguities in gloveboxes. An ideal solution to this issue would be to either develop an ion chamber that does not accrue surface contamination, or one that is self-cleaning while it is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER-484 CED4a Report: AFRRI ER1 Dosimetry Characterization

This report presents an analytical function as the reference neutron and photon dose (normalized to an ion chamber integral) for future nuclear accident dosimeter (NAD) exercise at the Armed Forces Radiobiology Research Institute (AFRRI). Various dosimeters and equipment were positioned within exposure room 1 (ER1) and irradiated using a 1.1 MW Training, Research, Isotope, General Atomics (TRIGA) Mark-F nuclear reactor. An ion chamber located in ER1 was used as a normalization factor in Equation 2. This allows for a quick calculation of neutron and photon dose based on the ion chamber data. Currently, AFRRI is in preparation to host a NAD exercise this summer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Log-N/Period Sensitivity Analysis

The Log-N/Period system utilizes a compensated ion chamber to measure neutron radiation in the reactor core. This analysis focuses on determining a more accurate value for the sensitivity of the installed compensated ion chambers for the Log-N/Period system at the ATR. Using calibration procedures a formula for indirectly calculating the sensitivity of the chambers was derived. Using historical data from approximately ten reactor cycles a new average sensitivity for both channels of the Log-N/Period system was determined.

42 ENGINEERING↗

Irradiation Results of Commercial Neutron and Gamma Sensors at the Ohio State University Research Reactor

This report serves to present the evaluation results of commercial radiation detectors (SPNDs) with the potential to accomplish the data objectives—having sufficient gamma and fast neutron sensitivity—at temperatures near 650°C. The detectors chosen for evaluation are gamma ion chambers from Exosens (previously known as Photonis) models CRGA11 and CRGE32 and tantalum-based self-powered neutron detectors (Ta-SPND) from Mirion. The evaluation was performed in a series of heat irradiations from ambient to 850°C in the 9.5-inch dry tube furnace at the Ohio State University Research Reactor (OSURR). Ion chamber counting curves were measured to evaluate sensor operability at temperature. Detector sensitivity to reactor power and temperature were measured and presented in curve fit parameters. The curve fit equations were used to identify the suggested operational temperatures based on reactor power. Overall, it was evaluated that the CRGA11 was not significantly affected by temperatures up to 650°C and is operable—with higher temperature-contributed signals—up to 700°C. The CRGE32 was more affected by the high temperatures compared to the CRGA11. As a result of increasing temperature, the leakage current was a dominating factor. While the detector can operate up to 600°C and 700°C with lowered high voltage, it is not recommended unless a suitably strong gamma flux field is present. Finally, Ta SPND did not demonstrate good performance beyond 350°C due to the presence of an unknown phenomenon at changing temperatures. The study of the phenomenon is an active research topic outside the scope of this project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SR19007 - Future TCAP Implementation Issues

This project demonstrates the success of the PDRD program in bringing a concept from the R&D phase to direct plant funding. Although Mini-TCAP technology is overall at a TRL of ~6.5, the specific questions addressed in this project were brought from a low (2-3 TRL) to a TRL 5 over the course of the project. This project successfully completed all initial goals ahead of schedule (inventory control, guard bed, ammonia impact, and cycle time) and furthermore addressed additional scope (continued TCAP evaluation, ion chamber) in FY20. First, this project resolved minor inventory control issues by introducing a new parameter tracking and correcting for inventory changes over multiple cycles. This project also involved modification of the previously constructed plant-configured Mini-TCAP in order to allow ammonia impurity studies. TCAP was tested with ammonia in the feed stream both with and without a guard bed present to determine guard bed efficacy and the effect of ammonia if it enters TCAP. The TCAP columns were then replaced with brazed columns, where the LN2 cooling coil is brazed to the column and the column is self-brazed along the coils. This drastically improved heat transfer and consequently reduced cycle time compared to the previous columns, in which the coils were mechanically held in place. Finally, additional scopes were taken on in FY20, including evaluation of TCAP with faster cycle time and procurement of ion chambers for future TCAP integration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beam particle identification and tagging of incompletely stripped heavy beams with HEIST

A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure the time-of-flight, a multi-sampling ion chamber to measure energy loss, and a high-purity germanium detector to identify isomer decays and calibrate the isotope identification system. HEIST has successfully identified 198 Pb and other nearby nuclei at energies of about 75 MeV/A. In the experiment discussed, a typical cut containing 89% of all 198 Pb 80+ in the beam had a purity of 86%. We examine the issues of charge state contamination. Here, the observed charge state populations of these ions are presented and, using an adjusted beam energy, are well described by the charge state model GLOBAL.

47 OTHER INSTRUMENTATION↗

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

Toward the implementation of self-powered, wireless, real-time reactor power sensing

The successful development of real-time, self-powered, wireless reactor power sensing technology would enable key operating parameters of every fuel assembly in a commercial reactor core to be continuously monitored, and potentially be utilized for applications such as closed-loop reactor control. This paper discusses the expansion of successful work on the application of Self Powered Neutron Detectors (SPND) for reactor power monitoring and the wireless transmission of these detector signals using advanced vacuum micro-electronic (VME) transmitter technology developed by Westinghouse in collaboration with the Penn State University Radiation Science and Engineering Center. Results demonstrate that this technology may be successfully applied via long-term testing in the Penn State TRIGA reactor. SPND are inherently slower than, for example, ion chambers due to their dependence on radioactive decay to generate a signal. Additional research developed delay compensation algorithms to accelerate the response of these detectors for use in near-real-time closed-loop reactor control. Initial results indicate that practical signal acceleration can be obtained digitally or with an equivalent analog circuit. Future research will apply an inverse model of the sensor’s balance differential equations to more-effectively accelerate the SPND signal. Use of inverse models will also prove to be adaptive in the sense that time-dependent burn-up of these detectors, due to neutron activation of the detector material, can be modeled and applied in the acceleration algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for estimating X-ray machine output through measurement and simulation

We report ball grid arrays are increasingly being applied in the electronics industry and may require X-ray inspection to ensure the integrity and correct placement of solder pins. However, as the architecture of integrated circuits continues to narrow while simultaneously growing more complex, the risk of electronic failure due to radiation damage increases. While medical X-ray devices have been held to high standards and are repeatedly shown to be well characterized, devices used for electronic inspection are often lacking detailed characterization. This study presents unique methods to solve for important properties in X-ray inspection devices such as source to object distance and energy spectrum. This information can then be applied to Monte Carlo models to achieve better overall dose estimates to electronics, which will lead to superior manufactured products. Since X-ray devices can vary greatly in source characteristics, this work investigates spectral measurement and Monte Carlo representation of three X-ray devices. For a Philips SRO 33 100 medical diagnostic device, the spectral output followed expected trends given by the prediction software SpekCalc and Spektr. For the Dage XD7500NT, direct measurement showed a spectral artifact that through the use of Gafchromic films, was shown to be a contributing effect in the dose output. For the Rad Source RS1800, a high powered irradiation device, direct spectral measurement was not achieved. However, a Monte Carlo model using an assumed spectra was found to match ion chamber measurements to a high degree.

47 OTHER INSTRUMENTATION↗

Use of Receiver Operating Curve Analysis and Machine Learning With an Independent Dose Calculation System Reduces the Number of Physical Dose Measurements Required for Patient-Specific Quality Assurance

Our purpose was to assess the use of machine learning methods and Mobius 3D (M3D) dose calculation software to reduce the number of physical ion chamber (IC) dose measurements required for patient-specific quality assurance during corona virus disease 2019.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Novel Dosimetry Method for Small Animal Irradiators Using 3D-printed Mouse Phantoms and Alanine Dosimeters

Abstract Accurate dosimetry is a crucial component of small animal and preclinical irradiation studies. Various dosimetry options are available but fail to characterize complex geometries and variable energy spectra of modern x-ray irradiators accurately. These options also lack national/international standards of recognition. This paper presents a novel dosimetry system, Dosequate, which uses murine phantoms embedded with alanine dosimeters and paired with x-ray energy spectra corrections to deliver consistent and accurate dosimetry measurements. This study compares Dosequate measurements against a Precision X-RAD 320 internal ion chamber and the treatment planning system of an Xstrahl Small Animal Radiation Research Platform. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. The Dosequate dosimetry method provides a robust and standardized approach for measuring absorbed dose in small animal irradiators. Its accuracy, reproducibility, and ability to account for complex irradiation geometries make it a valuable tool for preclinical research. This system has the potential to significantly improve the intercomparability of studies across different facilities and enhance the reliability of results.

Environmental Sciences & Ecology↗