Investigation of hydrogen and helium pumping by sputter ion pumps for Jupiter and outer planets mass spectrometer

The phenomena of ion pumping is reviewed with emphasis on the pumping mechanism for hydrogen and helium. The experimental tests measure the performance of a small, flight proven ion pump which has a nominal four liter/second pumping speed for air. The speed of this pump for hydrogen and helium, and for hydrogen/helium mixes, is presented with particular detail regarding the time dependence. Pump test results are related to anticipated performance of the mass spectrometer by the pumping speeds for the gases to the partial pressure in the ion source. From this analysis, the pump specifications are quantified in terms of mission goals and in terms of observed pumping speeds for the various gases, load levels, and time periods.

Scott, B. W.↗

Investigation of a quadrupole ultra-high vacuum ion pump

The new nonmagnetic ion pump resembles the quadrupole ionization gage. The dimensions are larger, and hyperbolically shaped electrodes replace the four rods. Their surfaces follow y sq. = 36 + x sq. (x, y in centimeters). The electrodes, 55 cm long, are positioned lengthwise in a tube. At one end a cathode emits electrons; at the other end a narrowly wound flat spiral of tungsten clad with titanium on cathode potential can be heated for titanium evaporation. Electrons accelerated by a dc potential of the surface electrodes oscillate between the ends on rotational trajectories, if a high frequency potential superimposed on the dc potential is properly adjusted. Pumping speeds (4-100 liter/sec) for different gases at different peak voltages (1000-3000V) at corresponding frequencies (57-100 MHz), and at different pressures 0.00001 to the minus 9 power Torr were observed. The lowest pressure reached was below 10 to the minus 10 power Torr.

Schwarz, H. J.↗

Ion pump and leak life test

The fabrication and long term testing of a flight type ion pump and sintered inlet leak are described. These tests were conducted over a period of one year at an ion pump pressure of approximately 0.000001 torr. These long term tests were conducted to investigate aging of ion pumps and leaks under continuous use. Pumping speed and leak conductance, as well as other parameters, were measured on a weekly basis with ion pump start tests conducted on a monthly basis.

Ierokomos, N.↗

Ion pump provides increased vacuum pumping speed

Multiple-cell ion pumps with increased vacuum pumping speed are used for producing ultrahigh vacuums in vacuum tubes and mass spectrometers. The pump has eight cathode-anode magnetron cells arranged in a cylinder which increase the surface area of the cathode.

Source record↗

Extended ion pumped vacuum friction test

Boundary layer friction data under ion pumped vacuum was taken for sixteen material couples. The test series was an extension of a previous study of the effects of modified ion pumped environments. Sliding distances imposed in the present effort greatly exceeded any studied in the previous contiguous, flight or ground tests. Wear out of specific couples, in particular, thin film lubricants was noted. The behavior of the test hardware including wear out of the mechanisms was noted. As a result, the impact of test interruption was observed for several test couples. Recovery of the friction upon re-establishing sliding in vacuum was generally rapid. The results of the extended sliding study reinforce the previous conclusion that sliding distance (mechanical history) is the primary factor in establishing the force limiting boundary layer friction. General friction value under the extended sliding confirm those observed in previous orbital and the related ground test studies.

Hammel, R. L.↗

Quadrupole ion pump performance characteristics.

A new nonmagnetic ion pump is described that resembles a quadrupole ionization gauge. The dimensions are larger, and hyperbolically shaped electrodes replace the four rods. Pumping speeds (4-100 liters per sec) for different gases at various peak voltages (1000-3000 V) at corresponding frequencies (57-100 MHz) and at different pressures (10 microtorr to 1 nanotorr) are reported.

Schwarz, H.↗

Miniature Lightweight Ion Pump

This design offers a larger surface area for pumping of active gases and reduces the mass of the pump by eliminating the additional vacuum enclosure. There are three main components to this ion pump: the cathode and anode pumping elements assembly, the vacuum enclosure (made completely of titanium and used as the cathode and maintained at ground potential) containing the assembly, and the external magnet. These components are generally put in a noble diode (or differential) configuration of the ion pump technology. In the present state of the art, there are two cathodes, one made of titanium and the other of tantalum. The anodes are made up of an array of stainless steel cylinders positioned between the two cathodes. All the elements of the pump are in a vacuum enclosure. After the reduction of pressure in this enclosure to a few microns, a voltage is applied between the cathode and the anode elements. Electrons generated by the ionization are accelerated toward the anodes that are confined in the anode space by the axial magnetic field. For the generation of the axial field along the anode elements, the magnet is designed in a C-configuration and is fabricated from rare earth magnetic materials (Nd-B-Fe or Sm-Co) possessing high energy product values, and the yoke is fabricated from the high permeability material (Hiperco-50A composed of Fe-Co-V). The electrons in this region collide with the gas molecules and generate their positive ions. These ions are accelerated into the cathode and eject cathode material (Ti). The neutral atoms deposit on the anode surfaces. Because of the chemical activity of Ti, the atoms combine with chemically active gas molecules (e.g. N2, O2, etc.) and remove them. New layers of Ti are continually deposited, and the pumping of active gases is thus accomplished. Pumping of the inert gases is accomplished by their burial several atomic layers deep into the cathode. However, they tend to re-emit if the entrapping lattice atoms are sputtered away. For stable pumping of inert gases, one side of the cathode is made of Ta. Impaction on Ta produces energetic, neutral atoms that pump the inert gases on the anode structure at the peripheral areas of the cathodes (between anode rings). For inert gases stability, a post design has been implemented. Here, posts of cathode material (Ti) are mounted on the cathode. These protrude into the initial part of the anode elements. Materials sputtered from the posts condense on the anode assembly and on the cathode plane at higher rates than in the normal diodes due to enhanced sputtering at glancing angles from geometrical considerations. This increases pumping by burial. This post design has enhanced pumping rates for both active and inert gases, compared with conventional designs.

Sinha, Mahadeva P.↗

Geometry and properties of the plasma in a quadrupole ion pump

The diameter of the plasma in a quadrupole ionization gauge and quadrupole ion pump has been measured as a function of pressure. The radio-frequency quadrupole systems are tuned in such a way that electrons remain on stable trajectories in the center of the tube. Being emitted at one end, the electrons encounter an inverted field at the other end so that they travel on spiral paths back and forth until they collide with the rest gas molecules, producing ions which are collected as an ion current at a cylinder surrounding the four hyperbolically shaped quadrupole electrodes.

Schwarz, H.↗

Model study of ATP and ADP buffering, transport of Ca(2+) and Mg(2+), and regulation of ion pumps in ventricular myocyte

We extended the model of the ventricular myocyte by Winslow et al. (Circ. Res 1999, 84:571-586) by incorporating equations for Ca(2+) and Mg(2+) buffering and transport by ATP and ADP and equations for MgATP regulation of ion transporters (Na(+)-K(+) pump, sarcolemmal and sarcoplasmic Ca(2+) pumps). The results indicate that, under normal conditions, Ca(2+) binding by low-affinity ATP and diffusion of CaATP may affect the amplitude and time course of intracellular Ca(2+) signals. The model also suggests that a fall in ATP/ADP ratio significantly reduces sarcoplasmic Ca(2+) content, increases diastolic Ca(2+), lowers systolic Ca(2+), increases Ca(2+) influx through L-type channels, and decreases the efficiency of the Na(+)/Ca(2+) exchanger in extruding Ca(2+) during periodic voltage-clamp stimulation. The analysis suggests that the most important reason for these changes during metabolic inhibition is the down-regulation of the sarcoplasmic Ca(2+)-ATPase pump by reduced diastolic MgATP levels. High Ca(2+) concentrations developed near the membrane might have a greater influence on Mg(2+), ATP, and ADP concentrations than that of the lower Ca(2+) concentrations in the bulk myoplasm. The model predictions are in general agreement with experimental observations measured under normal and pathological conditions.

NASA Discipline Cardiopulmonary↗