Establishing the accuracy of position–specific carbon isotope analysis of propane by GC–pyrolysis–GC–IRMS

Rationale: Position-specific (PS) δ 13 C values of propane have proven their ability to provide valuable information on the evolution history of natural gases. Two major approaches to measure PS δ 13 C values of propane are isotopic 13 C nuclear magnetic resonance (NMR) and gas chromatography-pyrolysis-gas chromatography-isotope ratio mass spectrometry (GC-Py-GC-IRMS). Measurement accuracy of the isotopic 13 C NMR has been verified, but the requirements of large sample size and long experimental time limit its applications. GC-Py-GC-IRMS is a more versatile method with a small sample size, but its accuracy has not been demonstrated. Methods: We measured the PS δ 13 C values of propane from nine natural gases using both 13 C NMR and GC-Py-GC-IRMS, then evaluated the accuracy of the GC-Py-GC-IRMS method. Results: The results show that large carbon isotope fractionations occurred for both terminal and central carbons within propane during pyrolysis. The isotope fractionations during the pyrolysis are reproducible at optimum conditions, but vary between the two GC-Py-GC-IRMS systems tested, affected by experimental conditions (e.g., pyrolysis temperature, flow rate, and reactor conditions). Conclusions: It is necessary to evaluate and calibrate each GC-Py-GC-IRMS system using propane gases with accurately determined PS δ 13 C values. Finally, this study also highlights a need for PS isotope standards for propane and other molecules (e.g., butane and acetic acid).

03 NATURAL GAS↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Integrated multi-wavelength microscope combining TIRFM and IRM modalities for imaging cellulases and other processive enzymes

We describe a multimodal microscope for visualizing processive enzymes moving on immobilized substrates. The instrument combines interference reflection microscopy (IRM) with multi-wavelength total internal reflectance fluorescence microscopy (TIRFM). The microscope can localize quantum dots with a precision of 2.8 nm at 100 frames/s, and was used to image the dynamics of the cellulase, Cel7a interacting with surface-immobilized cellulose. The instrument, which was built with off-the-shelf components and is controlled by custom software, is suitable for tracking other degradative enzymes such as collagenases, as well as motor proteins moving along immobilized tracks.

09 BIOMASS FUELS↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS↗

Internal Reaction Mass Taxonomy and Narrow-Down Study

Internal reaction mass (IRM) wave energy converters (WEC) capture wave energy by reacting against a moving mass that is suspended within their hulls. Due to their hermetically sealed Power Take Off (PTO), compact form factor and relatively simple mooring requirements, the National Renewable Energy Laboratory has identified IRM WECs are good candidates for applications such as ocean observation. A literature review of existing IRM mechanisms lead to the classification of IRM WECs based on their principal method of energy capture and principal axes of operation. The IRM categories include sliding mass, pendular and gyroscopic devices. A narrow down study was conducted to ascertain the most promising mechanisms for further investigation; devices were evaluated based on a decision matrix of weighted criteria that included device power output, prototypability and power to mass ratio. The narrow down study identified the issue of achieving resonance with pendulum-based designs, as well as the poor response produced by reaction to long period waves. Chaotic pendula and methods to multiply agitation were identified as a means to increase power output. Alternative methods of power generation, such as triboelectric nanogenerators, were also identified as a technology that would benefit from multiplied agitation and chaotic motion. This work was funded under the U.S. Department of Energy's Water Power Technologies Office's Powering the Blue Economy portfolio.

ENGINEERING,TIDAL AND WAVE POWER↗

Magnetic asymmetry induced anomalous spin-orbit torque in IrMn

We demonstrate an anomalous spin-orbit torque induced by the broken magnetic symmetry in the antiferromagnet IrMn. We study the magnetic structure of three phases of IrMn thin films using neutron diffraction technique. The magnetic mirror symmetry M ' is broken laterally in both L 1 0 - IrMn and L 1 2 - IrM n 3 but not γ - IrM n 3 . We observe an out-of-plane dampinglike spin-orbit torque in both L 1 0 - IrMn /permalloy and L 1 2 - IrM n 3 /permalloy bilayers but not in γ - IrM n 3 /permalloy. This is consistent with both the symmetry analysis on the effects of a broken M ' on spin-orbit torque and the theoretical predictions of the spin Hall effect and the Rashba-Edelstein effect. In addition, the measured spin-orbit torque efficiencies are 0.61 ± 0.01, 1.01 ± 0.03, and 0.80 ± 0.01 for the L 1 0 , L 1 2 , and γ phases, respectively. Our work highlights the critical roles of the magnetic asymmetry in spin-orbit torque generation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry

Stable isotope ratio measurements using IRMS have been shown by LANL to be effective for tracking co-processed biogenic carbon, with results approaching that of AMS. The lower cost of an IRMS may enable deployment to refineries improving access and analysis turnaround times (≤ 2-hours), and by extension data that can allow process optimization to maximize renewable carbon in desired refinery products. This work will apply chemical separation approaches as part of the IRMS analyses, enabling biogenic carbon tracking in fuel product streams by boiling point range, by chemical class, or even by compound. This work will show IRMS to be at a minimum as reliable and comparable to AMS, by using separations to improve sensitivity at low blend ratios and enable refinery process optimization through onsite analysis.

36 MATERIALS SCIENCE↗

Practical considerations for amino acid isotope analysis

Over the last few decades, isotopic analysis of amino acids at the compound- and position-specific levels has been rapidly advancing across diverse fields. As these techniques progress, evaluation of isotopic fractionation associated with sample workup is essential. This critical review of analytical methods through the lens of isotope geochemistry provides a benchmark for researchers across disciplines seeking to make compound- and position-specific amino acid isotope measurements. We focus on preparation, acid hydrolysis, clean-up, derivatization, separation, and C, H, N, and S isotope measurement. Despite substantial customizability across these steps, the following general recommendations should maximize recovery while minimizing isotopic fractionation. Samples should be freeze-dried and stored anoxically at ≤ –20 °C prior to conventional acid hydrolysis (6N HCl, 110 °C, 20–24 h, anoxic), which suffices for many residues. Both gas and liquid chromatographic (GC and LC, respectively) techniques are well-established and separate about 15 amino acids; LC bypasses the need for derivatization, while GC provides higher sensitivity. Furthermore, when derivatization is needed, n-acetyl and alkoxycarbonyl esters provide the most reproducible C isotope ratios. For compound-specific analyses, online GC–IRMS and LC–IRMS systems offer the easiest workflow, but EA–IRMS enables potential multi-element isotope analysis. Emerging techniques like high-resolution mass spectrometry are also promising for multi-element analysis and recover position-specific isotopic information. Looking forward to the next decade of innovation, isotope geochemists and ecologists can improve amino acid isotope analysis by focusing on streamlining multi-element analysis and standardizing calibration practices across laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling of the Liquid Sampling–Atmospheric Pressure Glow Discharge to Orbitrap Mass Analyzers for Uranium Isotope Ratio Analysis: Evolution of the Methodology and Implications to the Field

Just over a decade ago, a truly outside-of-the-box approach to isotope ratio mass spectrometry (IRMS) was undertaken between research groups at Clemson University and the Pacific Northwest National Laboratory. The original motivation dealt with projections as to whether or not microplasmas could be developed into practical elemental ionization sources, perhaps for transportable analysis applications. In particular, the use of the liquid sampling–atmospheric pressure glow discharge (LS-APGD) was pursued. Its interfacing to an ultra-high resolution Orbitrap platform, proved not only facile, but opened up a wealth of potential applications. Here, we lay out a historical, tutorial description of the interfacing and the evolution of the methodology regarding IRMS of uranium. Practical challenges and opportunities are described, which hopefully provide guidance to further applications in high resolution IRMS. It is hoped that, while detailed and lengthy, the didactic nature of the presentation provides experimental insights and tips, and also serves as an homage to our very good friend, Professor Gary M. Hieftje, whose scientific inspiration and comradery have been immeasurably important in our own careers.

Koppenaal, David W.↗

Carbon, Nitrogen, and Sulfur Analysis of the Cetama Viognier Standard Reference Material

The Viognier sample was analyzed for C, N, and S concentrations and stable isotope compositions using an Elementar Vario Isotope Cube Elemental Analyzer (EA) that is coupled to an IsoPrime PrecisION IRMS. Powder samples were placed in tin capsules and then loaded onto a rotary autosampler. The autosampler dropped samples into the EA, and samples were combusted at 1175 °C over tungsten oxide in a continuous stream of helium carrier gas. A pulse of oxygen is added to the gas stream resulting in flash combustion of the tin capsule containing the sample, which raises the reaction temperature to approximately 1800 °C for a few seconds. The combustion reaction produces SO 2 , N 2 and CO 2 from any sulfur, nitrogen and carbon present in the sample. The resulting gases were then passed through a reduced copper reactor that was heated to 850 °C, to reduce NO x to N 2 , reduce SO 3 to SO 2 , and trap any volatile halogen compounds on silver wool. Following water removal using an adsorption tube, the N 2 , CO 2 , and SO 2 analyte gases were separated and purified using purge-trap columns. The purified gases were then carried through a thermal conductivity detector. The detector signal was passed to software that calculated elemental abundances based on integrated peak areas. The sample gases were then passed to the IRMS and stable isotope ratios were measured. Raw sample peak areas were corrected by subtracting the average peak area from blanks consisting of empty tin capsules run using the same EA analysis method. Blanks were also run following each replicate to verify that all the material was combusted. The Viognier sample was analyzed in triplicate on two days (target sample masses: 30, 60 and 90 mg). The following standards were analyzed to calibrate EA-IRMS measurements: IAEA-C6, USGS-40, USGS-41, IAEA-S1, and IAEA-S2.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

What can we learn from N 2 O isotope data? – Analytics, processes and modelling

The isotopic composition of nitrous oxide (N 2 O) provides useful information for evaluating N 2 O sources and budgets. Due to the co–occurrence of multiple N 2 O transformation pathways, it is, however, challenging to use isotopic information to quantify the contribution of distinct processes across variable spatiotemporal scales. Here, we present an overview of recent progress in N 2 O isotopic studies and provide suggestions for future research, mainly focusing on: analytical techniques; production and consumption processes; and interpretation and modelling approaches. Comparing isotope–ratio mass spectrometry (IRMS) with laser absorption spectroscopy (LAS), we conclude that IRMS is a precise technique for laboratory analysis of N 2 O isotopes, while LAS is more suitable for in situ/inline studies and offers advantages for site–specific analyses. When reviewing the link between the N 2 O isotopic composition and underlying mechanisms/processes, we find that, at the molecular scale, the specific enzymes and mechanisms involved determine isotopic fractionation effects. In contrast, at plot–to–global scales, mixing of N 2 O derived from different processes and their isotopic variability must be considered. We also find that dual isotope plots are effective for semi–quantitative attribution of co–occurring N 2 O production and reduction processes. More recently, process–based N 2 O isotopic models have been developed for natural abundance and 15 N–tracing studies, and have been shown to be effective, particularly for data with adequate temporal resolution. Here, despite the significant progress made over the last decade, there is still great need and potential for future work, including development of analytical techniques, reference materials and inter–laboratory comparisons, further exploration of N 2 O formation and destruction mechanisms, more observations across scales, and design and validation of interpretation and modelling approaches. Synthesizing all these efforts, we are confident that the N 2 O isotope community will continue to advance our understanding of N 2 O transformation processes in all spheres of the Earth, and in turn to gain improved constraints on regional and global budgets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Development towards stable chlorine isotope measurements of astromaterials using the modified Middleton source of an accelerator mass spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35 Cl and 37 Cl. Chlorine isotope variations (reported as δ 37 Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ 37 Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm 3 of a typical lunar rock sample–the average cathode accuracy is ~1‰. Finally, cathode reproducibility is typically ~1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ~3–6‰ for aliquots with ~1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

07 ISOTOPE AND RADIATION SOURCES↗

Interference Provides Clarity: Direct Observation of 2D Materials at Fluid–Fluid Interfaces

Monolayer particles of two-dimensional (2D) materials represent a scientifically and technologically interesting class of anisotropic particles with colloidal-scale lateral sizes but sub-nanometer thicknesses. This atomic-scale thickness leads to interesting phenomena that can be exploited in next-generation thin-film technologies, and fluid-fluid interfaces provide a potentially scalable platform to confine, assemble, and deposit functional thin films of 2D materials. However, directly observing how these materials interact and assemble into a given film morphology is experimentally challenging because of their sub-nanometer thicknesses. Here, we demonstrate the ability to directly observe graphene, molybdenum disulfide (MoS2), and hexagonal boron nitride (h-BN) particles at fluid-fluid interfaces using interference reflection microscopy (IRM). Monolayer MoS2 and graphene particles demonstrated >10% optical contrast at an air-water interface, which allowed us to quantitatively analyze in situ images of self-assembled MoS2 particles and to map trajectories of interacting graphene particles. Additionally, the Brownian motion of a graphene particle was tracked and analyzed in the context of passive microrheology theory for 2D particle probes. Our results demonstrate how IRM can be used to obtain quantitative spatiotemporal information regarding the self-assembly and dynamics of 2D materials at fluid-fluid interfaces. It will have a significant impact on our ability to investigate systems of atomically thin particles at fluid-fluid interfaces, an area that has fundamental scientific importance and materials science applications but has suffered from a lack of direct, in situ observation techniques.

2D material↗

Isotope ratio-based quantification of carbon assimilation highlights the role of plastidial isoprenoid precursor availability in photosynthesis

Abstract Background We report a method to estimate carbon assimilation based on isotope ratio-mass spectrometry (IRMS) of 13 CO 2 labeled plant tissue. Photosynthetic carbon assimilation is the principal experimental observable which integrates important aspects of primary plant metabolism. It is traditionally measured through gas exchange. Despite its centrality in plant research, gas exchange performs poorly with rosette growth habits typical of Arabidopsis thaliana , mutant lines with limited biomass, and accounts poorly for leaf shading. Results IRMS-based carbon assimilation values from plants labeled at different light intensities were compared to those obtained by gas exchange, and the two methods yielded similar values. Using this method, we observed a strong correlation between 13 C content and labeling time (R 2 = 0.999) for 158 wild-type plants labeled for 6 to 42 min. Plants cultivated under different light regimes showed a linear response with respect to carbon assimilation, varying from 7.38 nmol 13 C mg −1 leaf tissue min −1 at 80 PAR to 19.27 nmol 13 C mg −1 leaf tissue min −1 at 500 PAR. We applied this method to examine the link between inhibition of the 2 C -methyl- d -erythritol-4-phosphate (MEP) pathway and suppression of photosynthesis. A significant decrease in carbon assimilation was observed when metabolic activity in the MEP pathway was compromised by mutation or herbicides targeting the MEP pathway. Mutants affected in MEP pathway genes 1-DEOXY- d -XYLULOSE 5-PHOSPHATE SYNTHASE (DXS) or 1-HYDROXY-2-METHYL-2-(E)-BUTENYL 4-DIPHOSPHATE SYNTHASE (HDS) showed assimilation rates 36% and 61% lower than wild type. Similarly, wild type plants treated with the MEP pathway inhibitors clomazone or fosmidomycin showed reductions of 52% and 43%, respectively, while inhibition of the analogous mevalonic acid pathway, which supplies the same isoprenoid intermediates in the cytosol, did not, suggesting inhibition of photosynthesis was specific to disruption of the MEP pathway. Conclusions This method provides an alternative to gas exchange that offers several advantages: resilience to differences in leaf overlap, measurements based on tissue mass rather than leaf surface area, and compatibility with mutant Arabidopsis lines which are not amenable to gas exchange measurements due to low biomass and limited leaf surface area. It is suitable for screening large numbers of replicates simultaneously as well as post-hoc analysis of previously labeled plant tissue and is complementary to downstream detection of isotopic label in targeted metabolite pools.

2C‑methyl‑d‑erythritol 4‑phosphate pathway↗

High-dimensional isotomics, part 2: Observations of over 100 constraints on methionine's isotome

The abundances of different isotopic forms of a compound, or isotopologues, will vary based on its physical and chemical history. The number of isotopologues increases combinatorically with the size of a molecule, and even small molecules such as amino acids have thousands of potentially observable isotopic variants. However, due to the analytical challenges of separating and observing isotopologues, only a few dimensions of isotopic diversity are routinely measured. Overcoming these challenges requires both an experimental method to observe many isotopic properties and a theoretical framework for interpreting these experiments. In Part 1, we presented such a theoretical framework; here, we demonstrate an experimental method, which we apply to methionine. Our approach uses a Q Exactive HF Orbitrap to perform several “M + N experiments”, where a sample is ionized, a subset of its isotopologues with cardinal mass N daltons greater than the unsubstituted isotopologue is selected and fragmented, and the proportions of all detectable isotopic forms of those fragment ions are quantified. We perform M + 1, M + 2, M + 3, and M + 4 experiments of a methionine sample and standard where the sample has a 100 ‰ enrichment of 13C at the methyl carbon relative to the natural 13C abundance at that position in the standard, and is otherwise identical to the standard. We observe isotopic forms of 8 fragment ion species for each version of the M + N experiment. With the assistance of a forward model of expected mass spectra, we identify isotopic peaks for each fragment ion based on observed mass and abundance, screen these for data quality, and quantify abundances for 146 unique isotopic peaks at precisions of ≈ 0.3–3 ‰. We present our direct observations and use them to reconstruct the concentrations of 19 individual singly, doubly, and triply-substituted isotopologues; doing so gives fewer constraints and broader error bars than working with the direct observations, but may be more interpretable for some applications. We also examine possibilities for measuring additional peaks, which are primarily limited by the detection limit of the Orbitrap-IRMS method. We then suggest some possible uses of our direct measurements for chemical forensics and hypothesis testing. Furthermore, our results demonstrate the diversity of isotopic constraints currently observable and interpretable for organic molecules.

58 GEOSCIENCES↗

Kinetic and equilibrium reactions on natural and laboratory generation of thermogenic gases from Type II marine shale

The phenomenon that laboratory pyrolysis experiments produce much wetter gases than those in natural reservoirs is a long-recognized and debated problem in the investigation of natural gases in sedimentary basins. In this study, we explore the discrepancy by pyrolyzing a type II kerogen from the Woodford Shale in Oklahoma, compared with the previous results on the produced natural gases from the Arkoma Basin generated from the same source rock (Liu et al., 2019) with the discussion of gas and isotopic compositions at bulk and position-specific (PS) levels. An improved GC-pyrolysis-GC IRMS method is applied for the determination of PS δ 13 C of propane produced in the pyrolysis of the Woodford Shale at Easy %R o from 0.76 to 3.27. Kinetic and thermodynamic considerations of the chemical and isotopic compositions of the natural and laboratory pyrolysis gases suggest that the generation of light hydrocarbons involves uni-directional cracking reactions, exchange reactions with water, and likely reversible reactions among light hydrocarbons and other H-containing volatiles. After the gas generation in the unconventional Woodford Shale reservoirs, the C 1 -C 4 gases might have approached close to chemical equilibrium of C 1 -C 3 and isotope equilibrium of C 2 -C 1 and C 3 -C 1 pairs at their peak temperatures. The capping H for the generation of C 1 -C 4 in the Woodford Shale gases appears to have experienced at least partial exchange with the water, while that in the pyrolysis gases is only originated from organic-bound compounds with large kinetic isotope effects (KIE). Our findings indicate that elevated compound-specific and PS δ 13 C values of propane in the wet-gas cracking stage are significantly influenced by the breakdown of the thermally stable compounds (e.g., remaining kerogen, residues). A first synthesis of PS δ 13 C and δ 2 H isotopic compositions of propane from this study and the literature data suggests relatively similar isotopic structures of propane precursors in kerogens. Finally, this study demonstrates that PS isotope analysis of propane can contribute to identifying various geological (e.g., maturation, wet-gas cracking, H exchange, diffusion) and biodegradation processes.

58 GEOSCIENCES↗