Search NASA⌕ Search

SEARCH · Search NASA

Results for “Implantation Gradients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A dual dynamic shutter system for accelerating ion irradiation sample throughput via lateral gas implantation gradients

Ion irradiation for material performance testing is limited due to its serial nature, which allows for only one value of the implantation (appm) versus dose (dpa) parameter space to be explored for each ion and experiment at a time. While ion irradiation can accelerate the process by up to three orders of magnitude compared to neutron irradiation experiments, the sample throughput for ion irradiation remains relatively low. To address these limitations, a novel capability has been developed at the Michigan Ion Beam Laboratory (MIBL), enabling for the creation of single- and two-dimensional lateral ion implantation gradients using recently installed motorized-controlled ion-beam shutters. This advancement can generate a wide scope of the two-dimensional (H+, He2+) implantation parameter space within a single sample. Integration of this new capability now allows for dual- and triple-ion beam experiments to be performed with full user control over not only the ion implantation depth, but also laterally across the sample by imposing ion implantation concentration gradients, thus providing researchers with a high-throughput means for material testing under various irradiation conditions. Furthermore, recent improvements in MIBL's microbeam ion-beam analysis (IBA) target station now allow for probing these concentration gradients in irradiated alloys with exceptional spatial resolution, down to 10 µm. These two approaches promise to significantly improve ion irradiation capabilities and increase the sample throughput by several orders of magnitude. The application of the shutter technique plus the subsequent microbeam characterization of the imposed implantation gradients are showcased by two proof-of-principle ion-irradiated experiments, one performed on single-crystal Si and the other on the fusion-candidate alloy F82H-IEA. These advancements mark a substantial leap in ion-beam technology, offering researchers a robust, high-throughput method to efficiently investigate candidate alloys with high technological readiness for both advanced fission and fusion reactor applications, in a time- and cost-effective manner.

36 - MATERIALS SCIENCE↗

Thermodynamic assessment of the quaternary WTaCrV refractory high entropy alloy as a means to guide experimental approaches

The deployment of fusion energy poses challenges for materials in plasma facing components to withstand high temperatures and thermal gradients, particle implantation and neutron damage. The current material of choice is tungsten, although property degradation limits its consideration in future fusion reactors. Hence, materials with better resistance to harsh environments need to be developed for fusion energy to become a reality. High entropy alloys are being explored as potential candidates with some compositions showing good radiation resistance to defect cluster formation. One of these materials is the WTaCrV system, although only one composition has been tested under ion irradiation. In this work, we study the thermodynamic properties of the entire quaternary alloy composition range. Coupling first principles calculations, cluster expansion approaches, and Monte Carlo methods, we access the free energy functionals, short-range ordering as a function of temperature, and atomic configurations that can be compared to experimental observations. We use this data to inform experiments into compositions with higher propensity to form solid solutions, instead of phase separating. With this formalism we have developed thermodynamic database (TDB) files that can be used to plot quaternary phase diagrams.

Cluster Expansion↗

Machine learning unifies flexibility and efficiency of spinodal structure generation for stochastic biomaterial design

Abstract Porous biomaterials design for bone repair is still largely limited to regular structures (e.g. rod-based lattices), due to their easy parameterization and high controllability. The capability of designing stochastic structure can redefine the boundary of our explorable structure–property space for synthesizing next-generation biomaterials. We hereby propose a convolutional neural network (CNN) approach for efficient generation and design of spinodal structure—an intriguing structure with stochastic yet interconnected, smooth, and constant pore channel conducive to bio-transport. Our CNN-based approach simultaneously possesses the tremendous flexibility of physics-based model in generating various spinodal structures (e.g. periodic, anisotropic, gradient, and arbitrarily large ones) and comparable computational efficiency to mathematical approximation model. We thus successfully design spinodal bone structures with target anisotropic elasticity via high-throughput screening, and directly generate large spinodal orthopedic implants with desired gradient porosity. This work significantly advances stochastic biomaterials development by offering an optimal solution to spinodal structure generation and design.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation damage study of POCO ZXF-5Q graphite for neutrino production targets using 4.5 MeV helium ions

To address the challenges of increased beam power and target survivability associated with next-generation particle production beam lines, high dose, high-energy proton beam conditions are simulated using irradiation from low-energy ion beams. A low-energy ion irradiation study of POCO ZXF-5Q graphite under conditions similar to those of the NuMI NT-02 neutrino production target at the Fermi National Accelerator Laboratory is reported. Helium ion irradiation was performed at 100 ∘ C to a maximum damage level of 0.9 displacements per atom (DPA). Irradiation induced hardening, swelling of the irradiated region, inter-plane lattice expansion, and intraplane lattice contraction with increasing ion fluence was observed using micromechanical (nanoindentation, atomic force microscopy) and electron microscopy (high-resolution imaging, selected area diffraction) characterization. Similar changes were also observed in post irradiation examination of the NT-02 target indicating that ion irradiation can be a valuable tool for estimating radiation damage in proton beam targets. Caution must be exercised though, because the hardening, lattice alteration, and swelling occur to different magnitudes for a given damage level. The observed hardening and embrittlement were greater for ion irradiated graphite. For He ion irradiated samples the lattice spacing changes were smaller at low damage levels (78% less expansion and 71% less contraction at 0.1 DPA) and larger at high damage levels (38% more expansion and 5% more contraction at 0.9 DPA) relative to that observed in the NT-02 target. The magnitude of swelling was 8.5× greater under ion irradiation which is influenced by the differing damage gradients and inclusion of implanted He ions in the region of interest.

43 PARTICLE ACCELERATORS↗

High Radiation Resistance in the Binary W‐Ta System Through Small V Additions: A New Paradigm for Nuclear Fusion Materials

Abstract Refractory High‐Entropy Alloys (RHEAs) are promising candidates for structural materials in nuclear fusion reactors, where W‐based alloys are currently leading. Fusion materials must withstand extreme conditions, including i) severe radiation damage from energetic neutrons, ii) embrittlement due to H and He ion implantation, and iii) exposure to high temperatures and thermal gradients. Recent RHEAs, such as WTaCrV and WTaCrVHf, have shown superior radiation tolerance and microstructural stability compared to pure W, but their multi‐element compositions complicate bulk fabrication and limit practical use. In this study, it is demonstrated that reducing alloying elements in RHEAs is feasible without compromising radiation tolerance. Herein, two Highly Concentrated Refractory Alloys (HCRAs) − W 53 Ta 44 V 3 and W 53 Ta 42 V 5 (at.%) − were synthesized and investigated. We found that small V additions significantly influence the radiation response of the binary W–Ta system. Experimental results, supported by ab‐initio Monte Carlo simulations and machine‐learning‐driven molecular dynamics, reveal that minor variations in V content enhance Ta–V chemical short‐range order (CSRO), improving radiation resistance in the W 53 Ta 42 V 5 HCRA. By focusing on reducing chemical complexity and the number of alloying elements, the conventional high‐entropy alloy paradigm is challenged, suggesting a new approach to designing simplified multi‐component alloys with refractory properties for thermonuclear fusion applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Planetary noble gases

An overview of the history and current status of research on planetary noble gases is presented. The discovery that neon and argon are vastly more abundant on Venus than on earth points to the solar wind rather than condensation as the fundamental process for placing noble gases in the atmospheres of the terrestrial planets; however, solar wind implantation may not be able to fully reproduce the observed gradient, nor does it obviously account for similar planetary Ne/Ar ratios and dissimilar planetary Ar/Kr ratios. More recent studies have emphasized escape rather than accretion. Hydrodynamic escape, which is fractionating, readily accounts for the difference between atmospheric neon and isotopically light mantle neon. Atmospheric cratering, which is nearly nonfractionating, can account for the extreme scarcity of nonradiogenic noble gases (and other volatiles) on Mars.

Zahnle, Kevin↗

A Printed Microscopic Universal Gradient Interface for Super Stretchable Strain‐Insensitive Bioelectronics

Abstract Stretchable electronics capable of conforming to nonplanar and dynamic human body surfaces are central for creating implantable and on‐skin devices for high‐fidelity monitoring of diverse physiological signals. While various strategies have been developed to produce stretchable devices, the signals collected from such devices are often highly sensitive to local strain, resulting in inevitable convolution with surface strain‐induced motion artifacts that are difficult to distinguish from intrinsic physiological signals. Here all‐printed super stretchable strain‐insensitive bioelectronics using a unique universal gradient interface (UGI) are reported to bridge the gap between soft biomaterials and stiff electronic materials. Leveraging a versatile aerosol‐based multi‐materials printing technique that allows precise spatial control over the local stiffnesses with submicron resolution, the UGI enables strain‐insensitive electronic devices with negligible resistivity changes under a 180% uniaxial stretch ratio. Various stretchable devices are directly printed on the UGI for on‐skin health monitoring with high signal quality and near‐perfect immunity to motion artifacts, including semiconductor‐based photodetectors for sensing blood oxygen saturation levels and metal‐based temperature sensors. The concept in this work will significantly simplify the fabrication and accelerate the development of a broad range of wearable and implantable bioelectronics for real‐time health monitoring and personalized therapeutics.

Song, Kaidong [Department of Aerospace and Mechani↗

Measuring sub-surface spatially varying thermal conductivity of silicon implanted with krypton

The thermal properties of semiconductors following exposure to ion irradiation are of great interest for the cooling of electronic devices; however, gradients in composition and structure due to irradiation often make the measurement difficult. Furthermore, the nature of spatial variations in thermal resistances due to spatially varying ion irradiation damage is not well understood. In this work, we develop an advancement in the analysis of time-domain thermoreflectance to account for spatially varying thermal conductivity in a material resulting from a spatial distribution of defects. We then use this method to measure the near-surface (≲1 μm) thermal conductivity of silicon wafers irradiated with Kr + ions, which has an approximate Gaussian distribution centered 260 nm into the sample. Our numerical analysis presented here allows for the spatial gradient of thermal conductivity to be extracted via what is fundamentally a volumetric measurement technique. We validate our findings via transmission electron microscopy, which is able to confirm the spatial variation of the sub-surface silicon structure, and provide additional insight into the local structure resulting from the effects of ion bombardment. Thermal measurements found the ion stopping region to have a nearly 50x reduction in thermal conductivity as compared to pristine silicon, while TEM showed the region was not fully amorphized. Our results suggest this drastic reduction in silicon thermal conductivity is primarily driven by structural defects in crystalline regions along with boundary scattering between amorphous and crystalline regions, with a negligible contribution being due to implanted krypton ions themselves.

36 MATERIALS SCIENCE↗

Solar-wind and solar-flare maturation of the lunar regolith

Detailed predictions concerning the depth and time-dependent accumulation of solar-wind effects and solar-flare tracks in lunar dust grains were obtained by use of an adaptation of a Monte Carlo soil-mixing computer code described by Duraud et al. (1975). The predictions are compared to experimental measurements obtained by analyzing lunar dust grains as well as artificially irradiated minerals by a variety of techniques. A study of amorphous coatings of solar-wind radiation-damaged material on certain lunar grains sets limits on the integrated residence time of these grains in the ancient solar wind. Other topics discussed include solar wind maturation, the peculiar shape of the experimental distribution of central track densities in 50-micron grains, and the interpretation of both track gradients in 50-micron feldspars and the relatively 'low' concentration of solar-wind species implanted in ilmenite grains.

Bibring, J. P.↗

Reflecting boundary conditions for graded p-n junctions

In a graded junction, the formalism for handling reflecting boundary conditions must be modified. Since a significant drift term is present, zero recombination velocity at the surface does not imply a zero excess carrier gradient but rather zero overall flux. A model for analyzing p-n junctions fabricated by implantation or diffusion is presented, assuming the dominant recombination mechanism in the graded region is Auger. The model enables optimization of diode design. By proper selection of parameters, mainly by reducing surface concentration or by increasing the steepness of the dopant profile, it is possible to drastically reduce the saturation current generated by the graded region.

Schacham, S. E.↗

Short-term hemodynamic performance of the mitral Carpentier-Edwards PERIMOUNT pericardial valve. Carpentier-Edwards PERIMOUNT Investigators

BACKGROUND: Although long-term durability data exist, little data are available concerning the hemodynamic performance of the Carpentier-Edwards PERIMOUNT pericardial valve in the mitral position. METHODS: Sixty-nine patients who were implanted with mitral PERIMOUNT valves at seven international centers between January 1996 and February 1997 consented to participate in a short-term echocardiography follow-up. Echocardiographs were collected at a mean of 600+/-133 days after implantation (range, 110 to 889 days); all underwent blinded core lab analysis. RESULTS: At follow-up, peak gradients were 9.09+/-3.43 mm Hg (mean, 4.36+/-1.79 mm Hg) and varied inversely with valve size (p < 0.05). The effective orifice areas were 2.5+/-0.6 cm2 and tended to increase with valve size (p = 0.08). Trace mitral regurgitation (MR) was common (n = 48), 9 patients had mild MR, 1 had moderate MR, none had severe MR. All MR was central (n = 55) or indeterminate (n = 3). No paravalvular leaks were observed. Mitral regurgitation flow areas were 3.4+/-2.8 cm2 and were without significant volumes. CONCLUSIONS: In this multicenter study, these mitral valves are associated with trace, although physiologically insignificant, central MR. Despite known echocardiographic limitations, the PERIMOUNT mitral valves exhibit similar hemodynamics to other prosthetic valves.

Clinical Trial↗

Large format imaging arrays for the Atacama Cosmology Telescope

We describe progress in the fabrication, characterization, and production of detector arrays for the Atacama Cosmology Telescope (ACT). The completed ACT instrument is specified to image simultaneously at 145, 225, and 265 GHz using three 32x32 filled arrays of superconducting transition edge sensors (TES) read out with time-division-multiplexed SQUID amplifiers. We present details of the pixel design and testing including the optimization of the electrical parameters for multiplexed readout. Using geometric noise suppression and careful tuning of operation temperature and device bias resistance, the excess noise in the TES devices is balanced with detector speed for interfacing with the ACT optics. The design also accounts for practical tolerances such as transition temperature gradients and scatter that occur in the production of multiple wafers to populate fully the kilopixel cameras. We have developed an implanted absorber layer compatible with our silicon-on-insulator process that allows for tunable optical resistance with requisite on-wafer uniformity and wafer-to-wafer reproducibility. Arrays of 32 elements have been tested in the laboratory environment including electrical, optical, and multiplexed performance. Given this pixel design, optical tests and modeling are used to predict the performance of the filled array under anticipated viewing conditions. Integration of the filled array of pixels with a tuned backshort and dielectric plate in front of the array maximize absorption and the focal plane and suppress reflections. A mechanical design for the build of the full structure is completed and we report on progress toward the construction of a prototype array for first light on the ACT.

Chervenak, J. A.↗

Towards a Next Generation Search for Time-Reversal Violation Using Optically Addressable Nuclei in Cryogenic Solids (Final Technical Report, September 2018 - August 2023)

Certain rare pear-shaped nuclei have unmatched sensitivity to new kinds of forces between subatomic particles that are not the same when the arrow of time is reversed. Such forces are believed to be responsible for the near absence of antimatter in the observable Universe. These rare isotopes, some for the first time, will be produced in large numbers at the Facility for Rare Isotope Beams currently under operating at Michigan State University providing an unprecedented opportunity to probe for new physics. In anticipation, we are using abundant isotopes to develop new techniques to manipulate nuclei embedded inside an optically transparent solid at cryogenic temperatures. Implantation into a solid, such as neon and argon, is potentially an effective way to both efficiently capture and repeatedly probe the small number of rare nuclei, such as radium and protactinium. An optically transparent host medium at cryogenic temperatures would allow for the laser manipulation of the nuclei in a thermally quiet and stable environment for a wide variety of guest species such as polar molecules. In such systems, the nuclei are exposed to extraordinarily large electric fields and magnetic field gradients, which significantly amplifies the measurability of certain time-reversal violating effects. The potential sensitivity of this new approach could be at least a few hundred times greater than the current leading experiment which uses stable mercury atoms. We report on the design considerations and preliminary performance of an instrument used to produce and implant molecules into a frozen argon solid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diffusion of Na and K in the uppermost regolith of Mercury

We examine the conditions under which ions impacting the Hermean surface can act as a regional source of enhanced atmospheric column through ion implantation and subsequent release at the surface. At most latitudes, energetic (a few keV) Na or K ions which impact the nightside surface, are released quickly (well before noon) upon warming of the surface. We show that the relative sunrise/sunset difference produced by ion implantation is ((n)(sub SR) - (n)(sub SS)/(n)(sub Ave) = f, where f is the fraction of the photo-ions recycled, (n)(sub SR) is the average zenith column above the sunrise portion of the illuminated hemisphere, (n)(sub SS) is the average zenith column in the sunset portion, and (n)(sub Ave) is the average column over the sunlit disk. Thus, to produce a large sunrise/sunset difference via ion implantation and subsequent release requires efficient (close to total) recycling. We show that the most extensive set of available data reduced to Na column abundance does not show any sunrise enhancement. We argue that the K data do not permit an unambiguous interpretation in favor of sunrise/sunset differences. We further find that if an efficient surface loss process for the alkali is not operating after sunrise, the initial Na and K distribution will relax into the bulk of the solid. Preserved abundance gradients of Na and K in lunar glasses that the Arrhenius coefficients for impact glasses are likely more modest than those for laboratory glasses derived from rock by nonimpact processes, but the effect of the more modest diffusion rates is only to delay the efficient loss of Na by a few Earth days. We argue that implantation can lead to observable regional increases in the observed Na or K column densities only if it occurs at very high latitudes, where diffusion is slow. It is typically lower energy ions which impact at high latitude and these are both more numerous than the high energy ions and possess smaller average penetration depths; thus there are additional reasons to favor a high-latitude locus for any possible prompt return related increases in zenith column. We find that we cannot rule out sputtering as a source process, as the low-energy ions are efficient sputterers. Finally, we argue that the observed Na/K ratio in the atmopshere may be the expression of their different asymptotic rates of loss from the interiors of the regolith grains. If so, this allows us to fix the importance of sputtering and photon stimulated desorption relative to impact vaporization.

Killen, R. M.↗

A Pro‐Angiogenic Immunoprotective Membrane for Cell Therapies

Abstract Immunoisolation strategies that rely on porous membranes play an important role in cell transplantation therapies to protect cells from the host's immune system. These membranes must possess immunoprotective properties while facilitating the transport of nutrients and cell products to maintain the functional integrity of encapsulated cells. An easy and scalable process is described to fabricate a dual function porous polymeric membrane that shields cells against immune cell attack and promotes vascularization to address the nutritional and oxygen requirements of transplanted cells. The fabrication process results in a membrane cross‐section with a gradient of nanopores to micropores that support cell immunoisolation and interfacial vascularization requirements, respectively. The membranes demonstrate excellent cell compatibility and effectively prevent T cell transmigration without compromising glucose diffusion and oxygen permeability. In a murine subcutaneous implantation model, membranes are stable for 60 days and exhibit significantly reduced fibrous capsules, with enhanced vascularization near the membrane. These porous polymeric membranes can potentially be used as pro‐angiogenic immunoprotective membranes for cell transplantation applications where maximizing cell viability and function is of critical importance.

Engineering↗

Methods for Explainable Artificial Intelligence

We explored ways of quantifying information in a neural network. This can be used to determine the right size of a network or to infer the way in which a network is processing information. The first year and a half was somewhat exploratory while the last half of the project focused on approaches that seemed to show the most promise. The introduce a new way of computing explainable artificial intelligence (XAI) saliency maps that is several orders of magnitude faster than methods with similar fidelity We call it FastCAM. The method works be combining a Class Activation Map (CAM) method such as GradCAM with a forward activation map computed with a statistic we call SMOE Scale. The addition of the forward activation maps to CAM methods seems to always improve their fidelity. At the same time, computational overhead is not increased by very much. While Gradients with SmoothGrad scores better on some fidelity measures, it is overall not as good and requires more than 1500 times to compute. We demonstrate two completed applications of FastCAM on tasks outside of the LDRD at LLNL. The source code for FastCAM is currently being implanted into Captum, the official XAI toolkit for the popular deep learning toolkit PyTorch. The LDRD currently has 13 publications released to the public. 10 of them are journal length.

97 MATHEMATICS AND COMPUTING↗

Evaluation of dual-tip micromanometers during 21-day implantation in goats

Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

Non-NASA Center↗

Fiber Optic Sensing Technologies for Battery Management Systems and Energy Storage Applications

Applications of fiber optic sensors to battery monitoring have been increasing due to the growing need of enhanced battery management systems with accurate state estimations. The goal of this review is to discuss the advancements enabling the practical implementation of battery internal parameter measurements including local temperature, strain, pressure, and refractive index for general operation, as well as the external measurements such as temperature gradients and vent gas sensing for thermal runaway imminent detection. A reasonable matching is discussed between fiber optic sensors of different range capabilities with battery systems of three levels of scales, namely electric vehicle and heavy-duty electric truck battery packs, and grid-scale battery systems. The advantages of fiber optic sensors over electrical sensors are discussed, while electrochemical stability issues of fiber-implanted batteries are critically assessed. This review also includes the estimated sensing system costs for typical fiber optic sensors and identifies the high interrogation cost as one of the limitations in their practical deployment into batteries. Finally, future perspectives are considered in the implementation of fiber optics into high-value battery applications such as grid-scale energy storage fault detection and prediction systems.

25 ENERGY STORAGE↗