Search NASA⌕ Search

SEARCH · Search NASA

Results for “L SHELL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Simulation study of 3–5 keV x-ray conversion efficiency from Ar K-shell vs. Ag L-shell targets on the National Ignition Facility laser

Tailored, high-flux, multi-keV x-ray sources are desirable for studying x-ray interactions with matter for various civilian, space and military applications. For this study, we focus on designing an efficient laser-driven non-local thermodynamic equilibrium 3–5 keV x-ray source from photon-energy-matched Ar K-shell and Ag L-shell targets at sub-critical densities (∼n{sub c}/10) to ensure supersonic, volumetric laser heating with minimal losses to kinetic energy, thermal x rays and laser-plasma instabilities. Using HYDRA, a multi-dimensional, arbitrary Lagrangian-Eulerian, radiation-hydrodynamics code, we performed a parameter study by varying initial target density and laser parameters for each material using conditions readily achievable on the National Ignition Facility (NIF) laser. We employ a model, benchmarked against Kr data collected on the NIF, that uses flux-limited Lee-More thermal conductivity and multi-group implicit Monte-Carlo photonics with non-local thermodynamic equilibrium, detailed super-configuration accounting opacities from CRETIN, an atomic-kinetics code. While the highest power laser configurations produced the largest x-ray yields, we report that the peak simulated laser to 3–5 keV x-ray conversion efficiencies of 17.7% and 36.4% for Ar and Ag, respectively, occurred at lower powers between ∼100–150 TW. For identical initial target densities and laser illumination, the Ag L-shell is observed to have ≳10× higher emissivity per ion per deposited laser energy than the Ar K-shell. Although such low-density Ag targets have not yet been demonstrated, simulations of targets fabricated using atomic layer deposition of Ag on silica aerogels (∼20% by atomic fraction) suggest similar performance to atomically pure metal foams and that either fabrication technique may be worth pursuing for an efficient 3–5 keV x-ray source on NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory measurements of the K-shell transition energies in L-shell ions of Si and S [Energy measurements of K-shell transitions in L-shell ions of Si and S]

We have measured the energies of the strongest 1s–2${\ell }\ ({\ell }={\rm{s}},{\rm{p}})$ transitions in He- through Ne-like silicon and sulfur ions to an accuracy of $\lt 1\,\mathrm{eV}$ using the Lawrence Livermore National Laboratory's electron beam ion traps, EBIT-I and SuperEBIT, and the NASA/GSFC EBIT Calorimeter Spectrometer (ECS). We identify and measure the energies of 18 and 21 X-ray features from silicon and sulfur, respectively. The results are compared to new Flexible Atomic Code calculations and to semi-relativistic Hartree–Fock calculations by Palmeri et al. (2008). These results will be especially useful for wind diagnostics in high-mass X-ray binaries, such as Vela X-1 and Cygnus X-1, where high-resolution spectral measurements using Chandra's high-energy transmission grating has made it possible to measure Doppler shifts of $100\,\mathrm{km}\,{{\rm{s}}}^{-1}$. The accuracy of our measurements is consistent with that needed to analyze Chandra observations, exceeding Chandra's $100\,\mathrm{km}\,{{\rm{s}}}^{-1}$ limit. Hence, the results presented here not only provide benchmarks for theory, but also accurate rest energies that can be used to determine the bulk motion of material in astrophysical sources. Finally, we show the usefulness of our results by applying them to redetermine Doppler shifts from Chandra observations of Vela X-1.

74 ATOMIC AND MOLECULAR PHYSICS↗

L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

L-shell dielectronic satellite transitions of Fe XVII

We have used the relativistic multi-reference Møller-Plesset perturbation theory to calculate the positions of the dielectronic satellite transitions involving doubly excited 3ℓ3ℓ' configurations that are associated with the X-ray spectrum of Fe XVII. A comparison of these positions with the wavelengths employed in astrophysical modeling codes shows discrepancies of up to 36 mÅ. Inspection of the spectrum of Capella recorded with the high energy transmission grating on the Chandra X-Ray Observatory reveals several features enhanced by Fe XVI lines formed by dielectronic recombination, one of which may be of future diagnostic use as it is fairly well isolated and in large part formed by dielectronic recombination.

79 ASTRONOMY AND ASTROPHYSICS↗

Using L-shell x-ray spectra to determine conditions of non-local thermal dynamic equilibrium plasmas

K-shell x-ray spectra of Li- to H-like ions have long been used to determine plasma conditions. The ratio of integrated line intensities is used to determine the temperature. At the density of non-local thermal dynamic equilibrium (NLTE) plasmas (ne ≈ 10 21 cm -3 ), the K-shell spectrum is not very sensitive to density. We propose using the L-shell emission of open L-shell ions (C- to Li-like) as an alternative to determine both temperature and density of NLTE plasmas. First, the L-shell models of a mid-Z material need to be verified against the temperatures obtained using a K-shell spectrum of a low-Z material. A buried layer platform is being developed at the OMEGA laser to study the open L-shell spectra of NLTE plasmas of mid-Z materials. Studies have been done using a 250 μm diameter dot composed of a layer of 1200 Å thick Zn between two 600 Å thick layers of Ti, in the center of a 1000 μm diameter, 13 μm thick beryllium tamper. Lasers heat the target from both sides for up to 3 ns. The size of the emitting volume vs time was measured with x-ray imaging (face-on and side-on) to determine the density. The temperature was measured from the Ti K-shell spectra. The use of this platform for the verification of atomic L-shell models is discussed.

36 MATERIALS SCIENCE↗

Modeling X-Ray Photoionized Plasmas: Ion Storage Ring Measurements of Low Temperature Dielectronic Recombination Rate Coefficients for L-Shell Iron

Iron L-shell ions (Fe XVII to Fe XXIV) play an important role in determining the line emission and thermal and ionization structures of photoionized gases. Existing uncertainties in the theoretical low temperature dielectronic recombination (DR) rate coefficients for these ions significantly affects our ability to model and interpret observations of photoionized plasmas. To help address this issue, we have initiated a laboratory program to produce reliable low temperature DR rates. Here, we present some of our recent results and discuss some of their astrophysical implications.

Savin, D. W.↗

Temperature and density dependence of Kr L-shell spectrum in hot dense plasmas

Kr L-shell spectroscopy modeling results are discussed in this paper, focusing on the n = 4 to n = 2 line transitions of Be- and Li-like Kr ions. Collisional radiative atomic kinetic and Stark-broadened spectral line shape calculations show electron temperature Te and density ne sensitivity in the spectrum. The combination of the Te dependence due to the relative intensity of Be-like to Li-like line emissions in the range from 1.5 to 3 keV and the ne sensitivity from the Stark broadening effect on the line shapes in the range from 5×1023 to 2×1024/ cc results in a spectrum that can be employed to diagnose Te and ne. Two different collisional radiative atomic kinetic models i.e., Prismspect [J. J. MacFarlane, et al., Int. Fusion Sci. Appl. Conf. Proc. 457 (2003)] and ABAKO [Florido, et al., PRE, 80, 056402 (2009)] produce similar results in level populations and spectra. In x-ray spectroscopy of implosion cores, this Kr L-shell spectrum may prove useful in an intermediate Te range in which Ar is too ionized for its K-shell to be of diagnostic value and Kr is not ionized enough for its K-shell emission to be useful.

Physics↗

SU-G-IeP3-07: High-Resolution, High-Sensitivity Imaging and Quantification of Intratumoral Distributions of Gold Nanoparticles Using a Benchtop L-Shell XRF Imaging System

Purpose: To demonstrate the ability to perform high-resolution imaging and quantification of sparse distributions of gold nanoparticles (GNPs) within ex vivo tumor samples using a highly-sensitive benchtop L-shell x-ray fluorescence (XRF) imaging system. Methods: An optimized L-shell XRF imaging system was assembled using a tungsten-target x-ray source (operated at 62 kVp and 45 mA). The x-rays were filtered (copper: 0.08 mm & aluminum: 0.04 mm) and collimated (lead: 5 cm thickness, 3 cm aperture diameter) into a cone-beam in order to irradiate small samples or objects. A collimated (stainless steel: 4 cm thickness, 2 mm aperture diameter) silicon drift detector, capable of 2D translation, was placed at 90° with respect to the beam to acquire XRF/scatter spectra from regions of interest. Spectral processing involved extracting XRF signal from background, followed by attenuation correction using a Compton scatter-based normalization algorithm. Calibration phantoms with water/GNPs (0 and 0.00001–10 mg/cm{sup 3}) were used to determine the detection limit of the system at a 10-second acquisition time. The system was then used to map the distribution of GNPs within a 12×11×2 mm{sup 3} slice excised from the center of a GNP-loaded ex vivo murine tumor sample; a total of 110 voxels (2.65×10{sup −3} cm{sup 3}) were imaged with 1.3-mm spatial resolution. Results: The detection limit of the current cone-beam benchtop L-shell XRF system was 0.003 mg/cm{sup 3} (3 ppm). Intratumoral GNP concentrations ranging from 0.003 mg/cm{sup 3} (3 ppm) to a maximum of 0.055 mg/cm{sup 3} (55 ppm) and average of 0.0093 mg/cm{sup 3} (9.3 ppm) were imaged successfully within the ex vivo tumor slice. Conclusion: The developed cone-beam benchtop L-shell XRF imaging system can immediately be used for imaging of ex vivo tumor samples containing low concentrations of GNPs. With minor finetuning/optimization, the system can be directly adapted for performing routine preclinical in vivo imaging tasks. Supported by NIH/NCI grant R01CA155446 This investigation was supported by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Laboratory Measurements of the K-Shell Transition Energies in L-Shell Ions of Si and S

We have measured the energies of the strongest 1s-2 ℓ (azimuthal quantum number) (ℓ = s, p (s, p are angular momentum states)) transitions in He- through Ne-like silicon and sulfur ions to an accuracy of less than 1 electronvolt using the Lawrence Livermore National Laboratory's electron beam ion traps, EBIT-I and SuperEBIT, and the NASA/GSFC EBIT Calorimeter Spectrometer (ECS). We identify and measure the energies of 18 and 21 X-ray features from silicon and sulfur, respectively. The results are compared to new Flexible Atomic Code calculations and to semi-relativistic Hartree-Fock calculations by Palmeri et al. (2008). These results will be especially useful for wind diagnostics in high-mass X-ray binaries, such as Vela X-1 and Cygnus X-1, where high-resolution spectral measurements using Chandraʼs high-energy transmission grating has made it possible to measure Doppler shifts of 100 kilometers per second. The accuracy of our measurements is consistent with that needed to analyze Chandra observations, exceeding Chandraʼs 100 kilometers per second limit. Hence, the results presented here not only provide benchmarks for theory, but also accurate rest energies that can be used to determine the bulk motion of material in astrophysical sources. We show the usefulness of our results by applying them to redetermine Doppler shifts from Chandra observations of Vela X-1.

atomic data↗

Ionization disequilibrium in K- and L-shell ions

Time-gated Sc K-shell and Ge L-shell spectra are presented from a range of characterized thermodynamic states spanning ion densities of 1019–1020cm−3 and plasma temperatures around 2000 eV. For the higher densities studied and temperatures from 1000 to 3000 eV, the Sc and Ge x-ray emission spectra are consistent with steady-state calculations from the modern atomic kinetics model SCRAM. At the lower ion densities achieved through plasma expansion, however, the model calculations require a higher plasma temperature to reproduce the observed Ge spectrum. We attribute this to ionization disequilibrium of the Sc because the ionization time scales exceed the hydrodynamic timescale when the inferred temperatures diverge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of the L-shell copper X-pinch plasma produced by the compact generator of Ecole polytechnique using pattern recognition

Principal component analysis is applied and compared with the line ratios of special Ne-like transitions for investigating the electron beam effects on the L-shell Cu synthetic spectra. The database for the principal component extraction is created over a non Local Thermodynamic Equilibrium (non-LTE) collisional radiative L-shell Copper model. The extracted principal components are used as a database for Artificial Neural Network in order to estimate the plasma electron temperature, density, and beam fractions from a representative time-integrated spatially resolved L-shell Cu X-pinch plasma spectrum. The spectrum is produced by the explosion of 25-μm Cu wires on a compact LC (40 kV, 200 kA, and 200 ns) generator. The modeled plasma electron temperatures are about T{sub e} ∼ 150 eV and N{sub e} = 5 × 10{sup 19} cm{sup −3} in the presence of the fraction of the beams with f ∼ 0.05 and a centered energy of ∼10 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relativistic MR-MP Energy Levels for L-shell Ions of Sulfur and Argon

Calculated level energies for valence and K-vacancy states are given for the ion series S vii–S xiv and Ar ix–Ar xvi. The calculations were performed with the relativistic Multi-Reference Møller–Plesset Perturbation Theory method (MR-MP). The data set includes all the level energies with configurations $1{s}^{2}2{(s,p)}^{q}$, $1{s}^{2}2{(s,p)}^{q-1}{nl}$, $1{s}^{1}2{(s,p)}^{q+1}$, $1{s}^{1}2{(s,p)}^{q}{nl}$, $2{(s,p)}^{q+2}$, and $2{(s,p)}^{q+1}{nl}$, where 1 ≤ q ≤ 8, n ≤ 5, and l ≤ 3. We have compared our results with data from the National Institute of Standards and Technology (NIST) online database and with previous calculations. The average deviation of valence level energies ranges from 0.16 eV in Ne-like ions to 0.01 eV in Li-like ions, demonstrating that the present MR-MP valence level energies are highly accurate. In the case of K-vacancy states, the deviation is generally below 0.3 eV for Li-like S xiv and Ar xvi. The deviation for K-vacancy energies in other L-shell ions (Be-, B-, C-, N-, and O-like Ar ions) is higher but likely because the NIST-recommended values have a higher uncertainty. The data set includes many n = 4 and n = 5 valence and K-vacancy levels in L-shell ions of S and Ar that have not been previously reported. The data can be used for line identification and modeling of L-shell ions of S and Ar in astrophysical and laboratory-generated plasmas, and as energy references in the absence of more accurate laboratory calculations.

79 ASTRONOMY AND ASTROPHYSICS↗

K{sub β} to K{sub α} X-ray intensity ratios and K to L shell vacancy transfer probabilities of Co, Ni, Cu, and Zn

The K to L shell total vacancy transfer probabilities of low Z elements Co, Ni, Cu, and Zn are estimated by measuring the K{sub β} to K{sub α} intensity ratio adopting the 2π-geometry. The target elements were excited by 32.86 keV barium K-shell X-rays from a weak {sup 137}Cs γ-ray source. The emitted K-shell X-rays were detected using a low energy HPGe X-ray detector coupled to a 16 k MCA. The measured intensity ratios and the total vacancy transfer probabilities are compared with theoretical results and others’ work, establishing a good agreement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of charge and light yields for 127 Xe L -shell electron captures in liquid xenon

Dark matter searches using dual-phase xenon time-projection chambers (LXe-TPCs) rely on their ability to reject background electron recoils (ERs) while searching for signal-like nuclear recoils (NRs). ER response is typically calibrated using β -decay sources, such as tritium, but these calibrations do not characterize events accompanied by an atomic vacancy, as in solar neutrino scatters off inner-shell electrons. Such events lead to emission of x rays and Auger electrons, resulting in higher electron-ion recombination and thus a more NR-like response than inferred from β -decay calibration. We present a cross-calibration of tritium β -decays and Xe 127 electron-capture decays (which produce inner-shell vacancies) in a small-scale LXe-TPC and give the most precise measurements to date of light and charge yields for the Xe 127 L -shell electron-capture in liquid xenon. We observe a 6.9 σ ( 9.2 σ ) discrepancy in the L -shell capture response relative to tritium β decays, measured at a drift field of 363 ± 14 V / cm ( 258 ± 13 V / cm ), when compared to simulations tuned to reproduce the correct β -decay response. In dark matter searches, use of a background model that neglects this effect leads to overcoverage (higher limits) for background-only multi-kiloton-year exposures, but at a level much less than the 1 - σ experiment-to-experiment variation of the 90% C.L. upper limit on the interaction rate of a 50 GeV / c 2 dark matter particle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray emission-line spectra of photoionized plasmas - Density sensitivity of the Fe L-shell series

The circumsource environments of accretion-powered X-ray sources are likely to support relatively dense (greater than 10 exp 11/cu cm) photoionized X-ray emission-line regions. The Fe L-shell ions provide a versatile class of plasma diagnostics in this regime, their multielectron structures resulting in diverse spectral phenomena. Attention is given to the spectral response of Fe L-shell ions to variations in electron density over the range 10 exp 11 to 10 exp 16/cu cm. It is found that density-sensitive line ratios exist in the wavelength interval 12-17 A for the ions Fe XVII-XXI. The prominent role of radiative recombination in the population kinetics distinguishes the density-sensitive Fe lines in photoionized plasmas from those which operate in coronal equilibrium plasmas. The results of detailed atomic modeling of these ions are presented and applications to spectroscopic observations of accretion-driven X-ray sources are discussed.

Liedahl, Duane A.↗