Floating Potential Probe Langmuir Probe Data Reduction Results

During its first five months of operations, the Langmuir Probe on the Floating Potential Probe (FPP) obtained data on ionospheric electron densities and temperatures in the ISS orbit. In this paper, the algorithms for data reduction are presented, and comparisons are made of FPP data with ground-based ionosonde and Incoherent Scattering Radar (ISR) results. Implications for ISS operations are detailed, and the need for a permanent FPP on ISS is examined.

Morton, Thomas L.↗

Contamination effects on fixed-bias Langmuir probes

Langmuir probes are standard instruments for plasma density measurements on many sounding rockets. These probes can be operated in swept-bias as well as in fixed-bias modes. In swept-bias Langmuir probes, contamination effects are frequently visible as a hysteresis between consecutive up and down voltage ramps. This hysteresis, if not corrected, leads to poorly determined plasma densities and temperatures. With a properly chosen sweep function, the contamination parameters can be determined from the measurements and correct plasma parameters can then be determined. In this paper, we study the contamination effects on fixed-bias Langmuir probes, where no hysteresis type effect is seen in the data. Even though the contamination is not evident from the measurements, it does affect the plasma density fluctuation spectrum as measured by the fixed-bias Langmuir probe. We model the contamination as a simple resistor-capacitor circuit between the probe surface and the plasma. We find that measurements of small scale plasma fluctuations (meter to sub-meter scale) along a rocket trajectory are not affected, but the measured amplitude of large scale plasma density variation (tens of meters or larger) is attenuated. From the model calculations, we determine amplitude and cross-over frequency of the contamination effect on fixed-bias probes for different contamination parameters. The model results also show that a fixed bias probe operating in the ion-saturation region is affected less by contamination as compared to a fixed bias probe operating in the electron saturation region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined Impedance Probe and Langmuir Probe Studies of the Low-Latitude E Region

The EQUIS-2 sounding rocket and radar campaign, launched from Kwajalein Atoll in 2004, included a mission to study low-latitude irregularities and electrodynamics, led by NASA GSFC. This mission included two instrumented rockets launched into the nighttime E region (apogee near 120 km), which included comprehensive electrodynamics and neutral density instrumentation. These rockets carried the first of a new generation of impedance probes, that utilize a wide-band drive signal to simultaneously measure the impedance of an antenna in a plasma as a function of frequency from 7 kEIz to 4 MHz. at a rapid cadence. This technique promises to permit true plasma spectroscopy, and resulted in the identification of multiple plasma resonances and accurate measurements of the plasma density, even in the low density nighttime E region. We present analyses of the technique and resulting spectra, and show how these data may be combined with fixed-bias Langmuir Probe data to infer the temperature structure of the E region as well as providing accurate absolute calibrations for the very high time resolution fixed-bias probe data. The data is shown to agree well with data from ionosonde, the ALTAIR radar, and the Peruvian beacon experiment.

Rowland, D. E.↗

The digital mirror Langmuir probe: Field programmable gate array implementation of real-time Langmuir probe biasing

High bandwidth, high spatial resolution measurements of electron temperature, density, and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements, either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimized for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customizable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g., real-time control outputs and more voltage states) and scalability through collaboration.

47 OTHER INSTRUMENTATION↗

The Digital Mirror Langmuir Probe: Field Programmable Gate Array Implementation of Real-Time Langmuir Probe Biasing

High bandwidth, high spatial resolution measurements of electron temperature, density and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimised for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customisable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g. real-time control outputs, more voltage states) and scalability through collaboration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High density Langmuir probe array for NSTX scrape-off layer measurements under lithiated divertor conditions

A high density Langmuir probe array has been developed for measurements of scrape-off layer parameters in NSTX. Relevant scale lengths for heat and particle fluxes are 1-5 cm. Transient edge plasma events can occur on a time scale of several milliseconds, and the duration of a typical plasma discharge is {approx}1 s. The array consists of 99 individual electrodes arranged in three parallel radial rows to allow both swept and triple-probe operation and is mounted in a carbon tile located in the lower outer divertor of NSTX between two segments of the newly installed liquid lithium divertor. Initial swept probe results tracking the outer strike point through probe flux measurements are presented.

36 MATERIALS SCIENCE↗

Effect of fast drifting electrons on electron temperature measurement with a triple Langmuir probe

Triple Langmuir Probe (TLP) is a widely used diagnostics for instantaneous measurement of electron temperature and density in low temperature laboratory plasmas as well as in edge region of fusion plasma devices. Presence of a moderately energetic flowing electron component, constituting only a small fraction of the bulk electrons, is also a generally observed scenario in plasma devices, where plasmas are produced by electron impact ionization of neutrals. A theoretical analysis of its effect on interpretation of the TLP data for bulk electron temperature measurement is presented here assuming electron velocity distribution is not deviating substantially from a Maxwellian. The study predicts conventional expression from standard TLP theory to give overestimated value of bulk electron temperature. Correction factor is significant and largely depends on population density, temperature, and energy of the fast component. Experimental verification of theoretical results is obtained in the magnetized plasma linear experimental device of Saha Institute of Nuclear Physics where plasma is produced by an electron cyclotron resonance method and known to have a fast flowing electron component.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fixed bias, floating double probe technique with simple Langmuir probe characteristics

A new floating double-probe method is presented which has advantages over other floated-probe systems previously described in literature. The method utilized two electrodes, one of constant area and the other with a variable area. The two-electrode configuration is separated by a fixed bias voltage. The current-voltage characteristics of the new technique, which are generated by varying the area of the one electrode, are identical to those of a simple Langmuir probe, thus coupling all the advantages of a floated-probe system with the simple analysis scheme generally applied to the Langmuir probe for the determination of plasma density and temperature.

Szuszczewicz, E. P.↗

An Experimental Investigation of an Arcjet Thruster Exhaust Using Langmuir Probes

Electrostatic (Langmuir) probes of both spherical and cylindrical geometry have been used to obtain electron number density and temperature in the exhaust of a laboratory arcjet. The arcjet thruster operated on nitrogen and hydrogen mixtures to simulate fully decomposed hydrazine in a vacuum environment with background pressures less than 5 x 10 to the -2 Pa. The exhaust appears to be only slightly ionized (less than 1 percent) with local plasma potentials near facility ground. The current-voltage characteristics of the probes indicate a Maxwellian temperature distribution. Plume data are presented as a function of arcjet operating condition and also position in the exhaust.

Carney, Lynnette M.↗

Digital smoothing of the Langmuir probe I-V characteristic

Electrostatic probes or Langmuir probes are the most common diagnostic tools in plasma discharges. The second derivative of the Langmuir probe I-V characteristic is proportional to the electron energy distribution function. Determining the second derivative accurately requires some method of noise suppression. We compare the Savitzky-Golay filter, the Gaussian filter, and polynomial fitting to the Blackman filter for digitally smoothing simulated and measured I-V characteristics. We find that the Blackman filter achieves the most smoothing with minimal distortion for noisy data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fixed-bias floating double-probe technique with simple Langmuir-probe characteristics.

A new floating double-probe method is presented which has advantages over other floated-probe systems heretofore described in the literature. The method utilizes two electrodes, one of constant area and the other with a variable area, and the two-electrode configuration is separated by a fixed bias voltage. The current-voltage characteristics of the new technique, which are generated by varying the area of one electrode, are identical to those of a simple Langmuir probe, thus coupling all the advantages of a floated-probe system with the simple analysis scheme generally applied to the Langmuir probe for the determination of plasma density and temperature.

Szuszczewicz, E. P.↗

Behavior of Langmuir Probes in Non-Equilibrium Plasmas

Langmuir probes are diagnostic tools used to determine electron temperature, number density, and plasma potential. Irving Langmuir first used an electrostatic probe in the 1920s to find these characteristics in ionized gases. Single, double, and triple Langmuir probes are commonly used in plasma diagnostics because of their relative simplicity. In the single probe, a swept voltage is applied between the probe tip and circuit common to acquire a waveform showing the collected current as a function of applied voltage. A double Langmuir probe consists of two tips, both inserted into the plasma, with a voltage applied between them. As this voltage is swept, a current-voltage characteristic is measured. In a triple probe three probe tips are electrically coupled to each other with constant non-swept voltages applied between each of the tips. The voltages are selected to represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Triple Langmuir probe measurements have been widely employed for various types of plasmas, including pulsed and time-varying plasmas such as those seen in pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. The typical Langmuir probe analysis for determining electron temperature and number density of the plasma (for a single, double, or triple Langmuir probe) includes an assumption that the plasma is in thermal equilibrium. While the this assumption may be justified for some applications, it is unlikely that it is fully justifiable for pulsed and time-varying plasmas or for the entire time a plasma device is in use. In the present work, we model the responses of Langmuir probes as they are inserted into a range of simple equilibrium and non-equilibrium plasmas. We return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. Comparing the distribution function that was assumed a priori with the plasma density and temperature one would infer when applying standard probe theory to analyze the collected currents serves to illustrate the effect a non- Maxwellian plasma would have on results interpreted using the equilibrium probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.↗

Ion-temperature determination with a baffled Langmuir probe

An electrostatic Langmuir probe for real-time measurements of parameters in magnetized plasma is tested in fully ionized, barium, Q-machine plasma. The small-diameter, long-length, tungsten wire sensor, i.e., the probe tip, oriented with its cylindrical axis perpendicular to the magnetic field (B), is partially shielded by ceramic baffles, or masks, that form sensor-access slots between the baffles. Adjusting the azimuthal orientation of the slots, by rotating the probe about its cylindrical axis, changes the fraction of proximity gyro-orbiting electrons, relative to the fraction of proximity gyro-orbiting ions, that can access the recessed sensor along the magnetic field. Thus, the ratio between the electron and ion saturation currents, $I^{sat}_e$ and $I^{sat}_i$, can be adjusted without having affected the probe bias voltage V b . When optimally shielded ($I^{sat}_e/I^{sat}_i$=1), accurate, real-time measurements of space potential Vs can be acquired. When maximally shielded ($I^{sat}_e/I^{sat}_i$ << 1), accurate, real-time measurements of ion temperature T i can be acquired. Subtracting the floating potential V f of an optimally shielded baffled probe from V f of a maximally shielded baffled probe yields T i (and its fluctuation phase) in real time.

47 OTHER INSTRUMENTATION↗

On the interpretation of Langmuir probe data inside a spacecraft sheath

If a Langmuir probe is located inside the sheath of a negatively charged spacecraft, there is a risk that the probe characteristic is modified compared to that of a free probe in the ambient plasma. We have studied this probe-in-spacecraft-sheath problem in the parameter range of a small Langmuir probe (with radius r{sub LP}<<{lambda}{sub D}) using a modified version of the orbit motion limited (OML) probe theory. We find that the ambient electron contribution I{sub e}(U{sub LP}) to the probe characteristic is suitably analyzed in terms of three regions of applied probe potential U{sub LP}. In region I, where the probe is negatively charged (i.e., U{sub LP} U{sub 1}, there is first a transition region II in applied potential, U{sub 1}<U{sub LP}<U{sub 2}, in which the key factor to determine the shape of I{sub e}(U{sub LP}) is a potential minimum U{sub M} between the probe and the ambient plasma. This minimum gives the depth U{sub pl}-U{sub M} of a potential barrier that prevents the lowest energy ambient electrons from reaching the probe. For a high enough positive probe potential, in region III, the barrier becomes small. Here, I{sub e}(U{sub LP}) again approaches OML theory for a free probe. The boundary U{sub 2} between regions II and III is somewhat arbitrary; we propose a condition on the barrier, U{sub pl}-U{sub M}<<k{sub B}T{sub e}/e, as the definition of region III. The main findings in this work are qualitative rather than quantitative. The existence of the transition region points to that special care must be taken to extract plasma parameters from measured I(U{sub LP}) as the probe characteristic is likely to depart from usual OML in crucial respects: (1) the ambient plasma potential U{sub pl} falls into the transition region, but there is no obvious knee or other feature to identify it, (2) there is in this region no exponential part of I{sub e}(U{sub LP}) that can be used to obtain T{sub e}, instead, (3) the probe size is important in determining the curve shape. We have tentatively applied our simplified probe-in-sheath model to real probe data from the Cassini spacecraft, taken in the dense plasma of Saturn's magnetosphere. We propose that our model gives a better description than OML of measured Langmuir probe sweeps in space plasmas where the Langmuir probe is situated within the spacecraft sheath, i.e., for long Debye lengths. The understanding of these probe sweep effects in such regions may improve by self-consistent particle simulations of the spacecraft environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ram-wake effects on plasma current collection of the PIX 2 Langmuir probe

The Plasma Interaction Experiment 2 (PIX 2) Langmuir probe readings of the same polar magnetospheric regions taken on consecutive orbits showed occasional apparent densities as much as 10 times lower than the average, although each pass clearly showed density structures related to the day/night boundary. At other points in the orbit, Langmuir probe currents varied by as much as a factor of 20 on a time scale of minutes. The hypothesis is advanced that these apparent inconsistencies in Langmuir probe current are the results of the probe's orientation relative to the body of the spacecraft and the velocity vector. Theoretical studies predict a possible depletion in collected electron current by a factor of 100 in the wake. Experimental results from other spacecraft indicate that a wake electron depletion by a factor of 10 or so is realistic. This amount of depletion is consistent with the PIX 2 data if the spacecraft was rotating. Both the Sun sensor and temperature sensor data on PIX 2 show a complex variation consistent with rotation of the Langmuir probe into and out of the spacecraft wake on a time scale of minutes. Furthermore, Langmuir probe data taken when the probe was not in the spacecraft wake are consistent from orbit to orbit. This supports the interpretation that ram/wake effects may be the source of apparent discrepancies at other orientations.

Ferguson, D. C.↗

Properties of the wake of small Langmuir probes on sounding rockets

Split Langmuir probes have been used to study the near wake of small Langmuir probes on sounding rockets. Experiments have been performed on two rocket flights using planar disk and cylindrical geometries, and the results are presented. Significant wake perturbations in plasma density and temperature were found due to the probe body itself, even though the probes were of the order of or smaller than the Debye length. The largest effects of the wake are seen in the electron collection characteristics of the probe. The wake of small probes show apparent magnetic field aligned structure, even though the probes were much smaller than the ion gyroradius. On one flight, a space charge potential large enough to substantially alter photoemission, -3.5 volts, was observed.

Bering, E. A.↗

New insights on boundary plasma turbulence and the quasi-coherent mode in Alcator C-Mod using a Mirror Langmuir Probe

A new “Mirror Langmuir Probe” diagnostic, combined with a double-coil scanning magnetic probe, is used to interrogate Alcator C-Mod's quasi-coherent mode (QCM) with unprecedented detail. In ohmic EDA H-modes, the QCM is found to reside in a region of positive radial electric field, with a radial width (∼3 mm) that spans open and closed field line regions. Large amplitude, in-phase sinusoidal bursts (∼100 kHz) in density, electron temperature, and plasma potential are observed, with potential lagging density by ∼16°, producing an outward radial transport velocity of ∼10 m/s. Mode propagation corresponds to the sum of local E × B and electron diamagnetic drift velocities. Poloidal magnetic field fluctuations project to current filaments carrying peak current densities of ∼25 A/cm{sup 2}. An evaluation of parallel electron force balance (Ohm's law) over a fluctuation cycle indicates a significant electromotive component. Interchange drive is also a contributor in the current continuity (vorticity) equation. Thus, the QCM is primarily a separatrix-spanning electron drift-wave with interchange and electromagnetic contributions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗