Prototype LIBS Sensor for Sub-surface Water Quality Monitoring
Presented by NETL at AICHE, 11/18
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Presented by NETL at AICHE, 11/18
Presented by NETL at SCIX 2018, 10/18
Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.
This presentation presents an electronics free laser sensing technique and its ongoing and potential applications. A laser-based technique, popularly known as laser-induced breakdown spectroscopy has been prototyped for the determination of high-tech elements including rare earth elements and other elements in solid as well as aqueous sources. All optical unit without any electronics has been designed in such a way that it can be installed in the source environment and connected to other required components for controlling and data acquisition from the workstation. Measurement methods and results obtained for selected elemental species and overall performance of the developed prototype will be presented.
The instrument 'Potassium (K) Argon Laser Experiment' (KArLE) is developed and designed for in situ absolute dating of rocks on planetary surfaces. It is based on the K-Ar dating method and uses the Laser Induced Breakdown Spectroscopy - Laser Ablation - Quadrupole Mass Spectrometry (LIBSLA- QMS) technique. We use a dedicated interface to combine two instruments similar to SAM of Mars Science Laboratory (for the QMS) and ChemCam (for the LA and LIBS). The prototype has demonstrated that KArLE is a suitable and promising instrument for in situ absolute dating.
Laser-induced breakdown spectroscopy (LIBS) is starting to light the way for power plant operators who want to reduce coal ash deposition in their boilers. The method was developed by Lehigh University's Energy Research Centre and the Energy Research Co. The LIBS system analyzes the chemical properties of coal using a pulsating laser with two frequencies, one infrared and one visible light. The laser vaporizes a sample, resulting in a distinct elemental signature. From these data, a newly developed software package containing artificial neural network (ANN) models estimates ash fusion temperature and predicts coal slagging potential. LIBS is the size of a table top, safe to use and provides instantaneous data without interrupting the process. The performance of the LIBS system was verified in lab experiments and then the system was set up at Dominion's Brayton Point Power Station, a 1,150-MW coal-fired power plant in Somerset, MA. The project demonstrated the merit of the LIBS system that produces coal elemental analysis and estimated fusion temperatures. Further development is needed to equip a LIBS system with an automatic online coal-sampling attachment and to achieve higher accuracy and repeatability. The researchers have been awarded a second DOE grant to fund development of a commercial prototype of the LIBS system. 2 figs., 2 photos.
A prototype Laser Induced Breakdown Spectroscopy (LIBS) sensor is tested for the determination of rare earth elements (Eu and Yb) in liquid and solid samples. The sensor head, built using a monolithic passively Q-switched (PQSW) Nd:YAG laser, produced a 1064 nm laser beam with 3.3 ns pulses and an energy of 4.2 mJ. The measurements show good calibration linearity for both Eu and Yb with R 2 values above 0.99 for all analyzed spectral lines in liquid and solid samples. Limits of Detection (LODs) obtained were as low as 1 ppm, which are comparable to or better than those reported previously by using table top actively Q-switched systems. This study aims to develop a high sensitivity, field deployable sensor for characterizing existing and new sources of rare earth elements
Research programs are currently underway in the Joint CEA-AREVA Vitrification Laboratory (LCV) to develop and optimize Laser Induced Breakdown Spectroscopy (LIBS) for nuclear waste streams analyses. The laboratory has full scale prototypes with the advantage of working on simulated inactive solutions of fission products. LIBS is an elemental chemical analysis technology that uses a short laser pulse to create a micro-plasma on the sample surface. This analytical technique offers many advantages compared to other techniques. It includes a sample preparation-free measurement and an extremely fast measurement time, from a few seconds to a few minutes. This paper presents the LIBS technique available in the laboratory. The first LIBS analyzes results of liquid samples from the off-gas treatment unit integrated on the full scale vitrification process are also presented and discussed. These complex solutions contain suspended particles and up to 30 chemical elements. A vision of an online LIBS analysis cell is also proposed with the development and associated research steps. (authors)
Research programs are currently underway in the Joint CEA-AREVA Vitrification Laboratory (LCV) to develop and optimize Laser Induced Breakdown Spectroscopy (LIBS) for nuclear waste streams analyses. The laboratory has full scale prototypes with the advantage of working on simulated inactive solutions of fission products. LIBS is an elemental chemical analysis technology that uses a short laser pulse to create a micro-plasma on the sample surface. This analytical technique offers many advantages compared to other techniques. It includes a sample preparation-free measurement and an extremely fast measurement time, from a few seconds to a few minutes. This paper presents the LIBS technique available in the laboratory. The first LIBS analyzes results of liquid samples from the off-gas treatment unit integrated on the full scale vitrification process are also presented and discussed. These complex solutions contain suspended particles and up to 30 chemical elements. A vision of an online LIBS analysis cell is also proposed with the development and associated research steps. (authors)
The prototype of accreting, pulsating white dwarfs (GW Lib) underwent a large amplitude dwarf nova outburst in 2007. We used ultraviolet data from Galaxy Evolution Explorer and ground-based optical photometry and spectroscopy to follow GW Lib for three years following this outburst. Several variations are apparent during this interval. The optical shows a superhump modulation in the months following outburst, while a 19 minute quasi-periodic modulation lasting for several months is apparent in the year after outburst. A long timescale (about 4 hr) modulation first appears in the UV a year after outburst and increases in amplitude in the following years. This variation also appears in the optical two years after outburst but is not in phase with the UV. The pre-outburst pulsations are not yet visible after three years, likely indicating the white dwarf has not returned to its quiescent state.
The prototype of accreting, pulsating white dwarfs (GW Lib) underwent a large amplitude dwarf nova outburst in 2007. We used ultraviolet data from Galaxy Evolution Explorer and ground-based optical photometry and spectroscopy to follow GW Lib for three years following this outburst. Several variations are apparent during this interval. The optical shows a superhump modulation in the months following outburst, while a 19 minute quasi-periodic modulation lasting for several months is apparent in the year after outburst. A long timescale (about 4 hr) modulation first appears in the UV a year after outburst and increases in amplitude in the following years. This variation also appears in the optical two years after outburst but is not in phase with the UV. The pre-outburst pulsations are not yet visible after three years, likely indicating the white dwarf has not returned to its quiescent state.
Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.
Groundwater resources can be contaminated by a variety of surface and subsurface sources. For instance, metals can be leached from surface dumps (e.g. landfills, etc.) and reach groundwater supplies by percolation though the soil. Additionally, subsurface activities such as geologic carbon storage (GCS) could result in contamination. In the event of CO2 leakage, freshwater above the injection site can potentially be contaminated with metals either originating from the formation fluids or leached from formation rocks by CO2 acidification. Detection of these contaminating metals is critical for maintaining water safety and providing an early warning of a containment breach. Therefore, a compact, subsurface capable laser induced breakdown spectroscopy (LIBS) based sensor has been developed for groundwater quality monitoring applications. LIBS sensor technology has been advanced from benchtop feasibility studies to a custom fabricated, watertight prototype. The all optical sensor head is built using a low cost passively Q-switched (PQSW) laser, which is fiber coupled to a control unit containing the pump laser and a gated spectrometer. Separating the LIBS excitation laser from the pump and spectrometer allows the expensive and fragile components to remain in a safe, central location while only the sensor head needs to enter the subsurface. Testing of the prototype sensors show Limits of Detection (LODs) comparable to benchtop, actively Q-switched systems and has verified that the fiber coupling and triggering schemes perform as desired.
Abstract It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO 2 will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0–3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.
Laser-induced breakdown spectroscopy (LIBS) is a technique for measuring surface matter composition. LIBS is performed by focusing laser radiation onto a target surface, ablating the surface, forming a plasma, and analyzing the light produced. LIBS surface analysis is a possible diagnostic for characterizing plasma-facing materials in ITER. Oak Ridge National Laboratory has enabled the initial installation of a laser-induced breakdown spectroscopy diagnostic on the prototype Material-Plasma Exposure eXperiment (Proto-MPEX), which strives to mimic the conditions found at the surface of the ITER divertor. This paper will discuss the LIBS implementation on Proto-MPEX, preliminary design of the fiber optic LIBS collection probe, and the expected results.
Laser-induced breakdown spectroscopy (LIBS) is a technique for measuring surface matter composition. LIBS is performed by focusing laser radiation onto a target surface, ablating the surface, forming a plasma, and analyzing the light produced. LIBS surface analysis is a possible diagnostic for characterizing plasma-facing materials in ITER. Oak Ridge National Laboratory (ORNL) has enabled the initial installation of a laser-induced breakdown spectroscopy diagnostic on the prototype Material-Plasma Exposure eXperiment (Proto-MPEX), which strives to mimic the conditions found at the surface of the ITER divertor. This paper will discuss the LIBS implementation on Proto-MPEX, preliminary design of the fiber optic LIBS collection probe, and the expected results.
Sub-surface activity such as geologic carbon sequestration (GCS) has the potential to contaminate groundwater sources with dissolved metals originating from sub-surface brines or leaching of formation rock. Therefore, a Laser Induced Breakdown Spectroscopy (LIBS) based sensor is developed for sub-surface water quality monitoring. The sensor head is built using a low cost passively Q-switched (PQSW) laser and is fiber coupled to a pump laser and a gated spectrometer. The prototype sensor head was constructed using off the shelf components and a custom monolithic, PQSW laser and testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements (Ca, Sr, and K), quick data collection times, and Limits of Detection (LODs) that are comparable to or better than those of table top, actively Q-switched systems. The fiber coupled design gives the ability to separate the PQSW LIBS excitation laser from the pump source and spectrometer, allowing these expensive and fragile components to remain at the surface while only the low-cost, all optical sensor head needs to be exposed to the hostile downhole environment.
The importance of current Li-ion batteries (LIBs) in modern society cannot be overstated. While the energy demands of devices increase, the corresponding enhancements in energy density of battery technologies are highly sought after. Currently, many different battery concepts, such as Li-S and metal-air among many others, have been investigated. However, their practical implementation has mostly been restricted to the prototyping stage. In fact, most of these technologies require rework of existing Li-ion battery manufacturing facilities and will naturally incur resistance to change from industry. For this reason, one specifically attractive technology, anionic redox in transition metal oxides, has gained much attention in the recent years. Its ability to be directly used in already established processes and higher energy density with similar electrolyte formulation make it a key materials research direction for next generation Li-ion batteries. In regular LIBs, the redox active centers are the transition metal cation. In anion redox, both the anion (typically O) and the transition metal cation are utilized as redox centers with enormous implications for increasing energy density. This new material can be highly competitive for replacing the current LIB technologies. However, much is still unknown about its cyding mechanism. Upon activating the O redox couples, most cationic and anionic redox active materials will either evolve O 2 or undergo irreversible structural degradation with associated severe decreases in electrochemical performance. By understanding the transition from full anion redox to partial cationic and anionic redo; we hope readers can gain a deeper understanding of the topic. This Account will focus mainly on the work that was conducted by our group at Argonne National Laboratory. Herein, the phenomenon of cationic and anionic redox in a lithium-ion battery cathode will first be discussed. Our work in resonant inelastic X-ray scattering to investigate the spectroscopic features of O after delithiation has found potential "fingerprint" signals that could likely be used to identify and confirm reversible O redox if corroborated with other techniques. To follow, we will examine our work on Li-O 2 batteries. While our group and the research community have had many significant contributions and improvements to the field of Li-O 2 (such as decreasing overpotential and achieving cyclability in air environment), its practical application is still far from realization. Perhaps our most important contribution to this area is the discovery that Ir deposited on reduced graphene oxide can be used to halt the reduction of O 2 at the LiO 2 oxidation state. This not only significantly decreases the charge overpotential but also presents the important concept of oxidation-state controlled discharge. Subsequently, we will focus on our oxidation state-controlled redox-based charging of oxygen in a pure oxygen redox Li-ion battery. Future implications of this technology will be emphasized.