Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low threshold detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Land altimetry using satellite data from the GEOSAT sea altimeter

Several techniques are proposed or assessed from the GEOSAT sea altimeter, and changes are recommended in future RADAR altimeters. The first technique tried was to cross-correlate each waveform with the preceding one. Then the position giving the maximum correlation was taken as the correct placement of the new waveform in its data window. The resulting altitude profile was slightly more variable than that of the on-board tracker over flat rock (Salar de Uyuni), so apparently successive waveforms are too dissimilar to correlate. When cross-correlation failed, compensation was made for averaging. Raw waveforms are averaged in groups of 100 and it is these average waveforms which are available for ground processing. But while the 100 are being received, the window position is moved in time, at different constant rates for the first 50 and last 50. Assuming an unchanging waveform and a single window rate for the 100, first and last waveforms were obtained. Averaging their half-height arrival times gave an altitude profile similar to the median and centroid methods. The variability of this altitude profile suggests that even raw waveforms in a group of 100 may be too dissimilar to correlate. In other techniques, the pulse was judged to have arrived when one of these criteria was met: the wave amplitude meets a certain absolute threshold; wave amplitude meets a certain relative threshold; certain fraction of the area of the waveform has passed; and centroid of the waveform has passed. All methods gave altitude profiles at least as variable as the on-board tracker, and all were biased at least 0.5 meter to low altitudes, except the threshold detector. The threshold detector can be filtered spatially to resemble the on-board tracker, and perhaps it could be implemented without feedback. For operating over land, these changes are recommended in future altimeters: The window should not move while raw waveforms are being averaged; some of the raw waveforms should be telemetered to earth for study, placing the waveform in the window should allow for shape variety; and some form of threshold detector might be used to find the signal and place it.

Luft, Philip E.↗

A 163 micron laser heterodyne radiometer for OH

A 163 micron (1.836 THz) radiometer developed for airplane and/or balloon platforms is described. The laser local oscillator is a CO2 pumped methanol laser operating at a frequency which is approx. 1 GHz from the J = 3/2 - 1/2 transition of OH. The laser is used directly as a local oscillator or is translated in frequency to closer coincidence with the OH emission, depending on achieved detector IF bandwidth. Frequency translation techniques which are described are diode mixing and a method of single sideband generation using an external Stark modulated gas cell. The photoconductive mixer used is a strained Ge crystal, doped with Ga, originally used as an incoherent detector. The uniaxial strain on the Ga doped Ge crystal shifts the threshold for photoconduction from 100/cm to frequencies as low as 50/cm. These detectors are currently being characterized as mixers in the laboratory. Of particular interest are the effect of local oscillator power and strain on IF, bandwidth detector impedance, and conversion loss. Preliminary results of these tests are described and compared with theorectical expectations.

Pickett, H. M.↗

A Broadband X-Ray Imaging Spectroscopy with High-Angular Resolution: the FORCE Mission

We are proposing FORCE (Focusing On Relativistic universe and Cosmic Evolution) as a future Japan-lead X-ray observatory to be launched in the mid 2020s. Hitomi (ASTRO-H) possesses a suite of sensitive instruments enabling the highest energy-resolution spectroscopy in soft X-ray band, a broadband X-ray imaging spectroscopy in soft and hard X-ray bands, and further high energy coverage up to soft gamma-ray band. FORCE is the direct successor to the broadband X-ray imaging spectroscopy aspect of Hitomi (ASTRO-H) with significantly higher angular resolution. The current design of FORCE defines energy band pass of 1-80 keV with angular resolution of <15" in half-power diameter, achieving a 10 times higher sensitivity above 10 keV compared to any previous missions with simultaneous soft X-ray coverage. Our primary scientific objective is to trace the cosmic formation history by searching for "missing black holes" in various mass-scales: "buried supermassive black holes (SMBHs)" (> 10(exp 4) Stellar Mass) residing in the center of galaxies in a cosmological distance, "intermediate-mass black holes" (10(exp 2)-(10(exp 4) Stellar Mass) acting as the possible seeds from which SMBHs grow, and "orphan stellar-mass black holes" (< 10(exp 2) Stellar Mass) without companion in our Galaxy. In addition to these missing BHs, hunting for the nature of relativistic particles at various astrophysical shocks is also in our scope, utilizing the broadband X-ray coverage with high angular-resolution. FORCE are going to open a new era in these fields. The satellite is proposed to be launched with the Epsilon vehicle that is a Japanese current solid-fuel rocket. FORCE carries three identical pairs of Super-mirror and wide-band X-ray detector. The focal length is currently planned to be 10 m. The silicon mirror with multi-layer coating is our primary choice to achieve lightweight, good angular optics. The detector is a descendant of hard X-ray imager onboard Hitomi (ASTRO-H) replacing its silicon strip detector with SOI-CMOS silicon pixel detector, allowing an extension of the low energy threshold down to 1 keV or even less.

Hard X-ray↗

High resolution, low energy avalanche photodiode X-ray detectors

Silicon avalanche photodiodes have been fabricated, and their performance as X-ray detectors has been measured. Photon sensitivity and energy resolution were measured as a function of size and operating parameters. Noise thresholds as low as 212 eV were obtained at room temperature, and backscatter X-ray fluorescence data were obtained for aluminum and other light elements. It is concluded that the results with the X-ray detector are extremely encouraging, and the performance is challenging the best available proportional counters. While not at the performance level of either cryogenic silicon or HgI2, these device operate at room temperature and can be reproduced in large numbers and with much larger areas than typically achieved with HgI2. In addition, they are rugged and appear to be indefinitely stable.

Farrell, R.↗

Ion-implanted extrinsic Ge photodetectors with extended cutoff wavelength

Far-IR Ge detectors fabricated using boron ion implantation are shown to exhibit operating characteristics compatible with requirements for low background applications. Device parameters such as low dark currents, reasonably good sensitivity, and extended wavelength threshold demonstrate that ion-implanted Ge far-IR detectors offer promise for use in astrophysics instrumentation.

Wu, I. C.↗

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗

An improved pulse-height analyzer for energetic particle measurements in the upper atmosphere

An energetic particle spectrometer for measurements in the upper atmosphere by rocket is described. The system has two methods of processing data. One is a staircase generator using threshold detectors; the other is a peak detector. The system incorporates a logarithmic converter for better resolution at low amplitudes and better use of telemetry channels. The circuits are described and calibration procedures are given. Modifications are recommended for high flux environments. Appendices cover sampling error in the peak detector and modifications made to the receiver of the propagation experiment.

Dean, L.↗

GaAs-based optoelectronic neurons

An integrated, optoelectronic, variable thresholding neuron implemented monolithically in GaAs integrated circuit and exhibiting high differential optical gain and low power consumption is presented. Two alternative embodiments each comprise an LED monolithically integrated with a detector and two transistors. One of the transistors is responsive to a bias voltage applied to its gate for varying the threshold of the neuron. One embodiment is implemented as an LED monolithically integrated with a double heterojunction bipolar phototransistor (detector) and two metal semiconductor field effect transistors (MESFET's) on a single GaAs substrate and another embodiment is implemented as an LED monolithically integrated with three MESFET's (one of which is an optical FET detector) on a single GaAs substrate. The first noted embodiment exhibits a differential optical gain of 6 and an optical switching energy of 10 pJ. The second embodiment has a differential optical gain of 80 and an optical switching energy of 38 pJ. Power consumption is 2.4 and 1.8 mW, respectively. Input 'light' power needed to turn on the LED is 2 micro-W and 54 nW, respectively. In both embodiments the detector is in series with a biasing MESFET and saturates the other MESFET upon detecting light above a threshold level. The saturated MESFET turns on the LED. Voltage applied to the biasing MESFET gate controls the threshold.

Lin, Steven H.↗

Gravity Reception and Cardiac Function in the Spider

The following features of the arachnid gravity system were studied. (1) the absolute threshold to hyper-gz is quite low indicating fine proprioreceptive properties of the lyriform organ, the Gz/vibration detector; (2) the neurogenic heart of the spider is a good dependent variable for assessing its behavior to Gz and other stimuli which produce mechanical effects on the exoskeleton; (3) Not only is the cardiac response useful but it is now understood to be an integral part of the system which compensates for the consequences of gravity in the spider (an hydraulic leg extension); and (4) a theoretical model was proposed in which a mechanical amplifier, the leg lever, converts a weak force (at the tarsus) to a strong force (at the patella), capable of compressing the exoskeleton and consequently the lyriform receptor.

Finck, A.↗

FET's Perform Well At Cryogenic Temperatures

New metal-oxide-semiconductor field-effect transistors designed for source-follower preamplifiers operating at liquid-helium temperatures in conjunction with infrared detectors. Lower thresholds and offset give CryoFET's greater dynamic range and linearity than conventional MOSFET's at low temperatures and facilitates pair balancing to reduce offsets in output. Reduces heat loading of cryogenic system, extending life, reliability, and performance of cryogenic infrared instruments.

Sclar, N.↗

Orbiter global positioning system design and Ku-band problem investigations, exhibit B, revision 1

The shuttle Ku-band Costas loop lock detector output signal appears to vary about the lock detection threshold (the lock detect flag is on and off) shortly after the carrier acquisition starts. Real time computer simulation was performed to obtain the signal output from the low pass filter of the lock detector. Based on this simulation, it appears that the oscillation of in-lock and out-lock is related to tracking process and is not caused by the sweep acquisition algorithm.

Lindsey, W. C.↗

The role of fiber optics in mass spectrometer electro-optical ion detection

This paper describes the development of an electro-optical ion detector combining the best features of photographic and electrical ion detection (i.e., wide mass range coverage and low ion detection threshold respectively). A nineteen fold fiber optic image dissector is discussed which reformats the 1 mm x 361 mm mass spectrometer focal plane format to a 19 mm x 19 mm format suitable for vidicon imaging and electronic display of the data.

Norris, D. D.↗

Fine-Pitch CdTe Detector for Hard X-Ray Imaging and Spectroscopy of the Sun with the FOXSI Rocket Experiment

We have developed a fine-pitch hard X-ray (HXR) detector using a cadmium telluride (CdTe) semiconductor for imaging and spectroscopy for the second launch of the Focusing Optics Solar X-ray Imager (FOXSI). FOXSI is a rocket experiment to perform high sensitivity HXR observations from 4 to 15 keV using the new technique of HXR focusing optics. The focal plane detector requires less than 100 micrometers position resolution (to take advantage of the angular resolution of the optics) and approximately equals 1 keV energy resolution (full width at half maximum (FWHM)) for spectroscopy down to 4 keV, with moderate cooling (greater than -30 C). Double-sided silicon strip detectors were used for the first FOXSI flight in 2012 to meet these criteria. To improve the detectors' efficiency (66% at 15 keV for the silicon detectors) and position resolution of 75 micrometers for the second launch, we fabricated double-sided CdTe strip detectors with a position resolution of 60 micrometers and almost 100% efficiency for the FOXSI energy range. The sensitive area is 7.67 mm x 7.67 mm, corresponding to the field of view of 791'' x 791''. An energy resolution of 1 keV (FWHM) and low-energy threshold of approximately equals 4 keV were achieved in laboratory calibrations. The second launch of FOXSI was performed on 11 December 2014, and images from the Sun were successfully obtained with the CdTe detector. Therefore, we successfully demonstrated the detector concept and the usefulness of this technique for future HXR observations of the Sun.

Ishikawa, Shin-nosuke↗

Design, production, and testing of field effect transistors

Cryogenic MOSFETS (CRYOFETS), specifically designed for low temperature preamplifier application with infrared extrinsic detectors were produced and comparatively tested with p-channel MOSFETs under matched conditions. The CRYOFETs exhibit lower voltage thresholds, high source-follower gains at lower bias voltage, and lower dc offset source voltage. The noise of the CRYOFET is found to be 2 to 4 times greater than the MOSFET with a correspondingly lower figure of merit (which is established for source-follower amplifiers). The device power dissipation at a gain of 0.98 is some two orders of magnitude lower than for the MOSFET. Further, CRYOFETs are free of low temperature I vs V character hysteresis and balky conduction turn-on effects and operate effectively in the 2.4 to 20 K range. These devices have promise for use on long term duration sensor missions and for on-focal-plane signal processing at low temperatures.

Sclar, N.↗

Neutron fluences and dose equivalents measured with passive detectors on LDEF

Neutron fluences were measured on LDEF in the low energy (< 1 MeV) and high energy (> 1 MeV) ranges. The low energy detectors used the 6Li(n,alpha)T reaction with Gd foil absorbers to separate thermal (< 0.2 eV) and resonance (0.2 eV-1 MeV) neutron response. High energy detectors contained sets of fission foils (181Ta, 209Bi, 232Th, 238U) with different neutron energy thresholds. The measured neutron fluences together with predicted spectral shapes were used to estimate neutron dose equivalents. The detectors were located in the A0015 and P0006 experiments at the west and Earth sides of LDEF under shielding varying from 1 to 19 g/cm2. Dose equivalent rates varied from 0.8 to 3.3 microSv/d for the low energy neutrons and from 160 to 390 microSv/d for the high energy neutrons. This compares with TLD measured absorbed dose rates in the range of 1000-3000 microGy/d near these locations and demonstrates that high energy neutrons contribute a significant fraction of the total dose equivalent in LEO. Comparisons between measurements and calculations were made for high energy neutrons based on fission fragment tracks generated by fission foils at different shielding depths. A simple 1-D slab geometry was used in the calculations. Agreement between measurements and calculations depended on both shielding depth and threshold energy of the fission foils. Differences increased as both shielding and threshold energy increased. The modeled proton/neutron spectra appeared deficient at high energies. A 3-D model of the experiments is needed to help resolve the differences.

LDEF Project↗

Science Enabling ASICs and FEEs for the JUICE and JEO Missions

A family of science enabling radiation hard Application Specific Integrated Circuits (ASICs), Front End Electronics (FEEs) and Event Processing Systems, with flight heritage on many NASA missions, is presented. These technologies play an important role in the miniaturization of instruments -and spacecraft systems- at the same time increasing performance and reducing power. The technologies target time of flight, position sensing, and energy measurements as well as standard housekeeping and telemetry functions for particle and fields instruments, but find applications in other instrument categories too. More specifically the technologies include: the TOF chip, 1D and 2D Delay Lines with MCP detectors, for high precision fast and low power time of flight and position sensing; the Energy chip for multichannel SSD readout with time over threshold and standard voltage read out for TDC and ADC digitization; Fast multi channel read out chip with commandable thresholds; the TRIO chip for multiplexed ADC and housekeeping etc. It should be mentioned that the ASICs include basic trigger capabilities to enable random event processing in a heavy background of penetrators and UV foreground. Typical instruments include time of flight versus energy and look angle particle analyzers such as: plasma composition, energetic particle, neutral atom imaging as well as fast plasma and deltaE/E ion/electron telescopes. Flight missions include: Cassini/LEMMS, IMAGE/HENA, MESSENGER/EPPS/MLA/X-ray/MLA, STEREO, PLUTO-NH/PEPSSI/LORI, IBEX-Lo, JUNO/JEDI, RBSP/RBSPICE, MMS/HPCA/EPD, SO/SIS. Given the proven capability on heavy radiation missions such as JUNO, MMS and RBSB, as well diverse long duration missions such as MESSENGER, PLUTO and Cassini, it is expected that these technologies will play an important role in the particle and fields (at least) instruments on the upcoming JUICE and JEO missions.

Paschalidis, Nicholas↗