Search NASASearch

SEARCH · Search NASA

Results for “MAGNETIC DISPERSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Shock induced magnetic effects in fine particle iron dispersions

Magnetic effects associated with shock induced transformation of fcc antiferromagnetic iron precipitates in polycrystalline copper disks at levels up to 5 GPa in weak magnetic fields (H not greater than 0.5 Oe) were investigated. The demagnetization and anisotropy associated with second order transition, the effects of plastic deformation in imparting magnetic anisotropy and magnetic hardening, and the influence of post shock thermal transients on magnetization associated with recovery, recrystallization and grain growth were studied. It was found that on the microsecond time scale of the shock induced first order transformation, the field sense is recorded in the transformed iron particles. For a given particle size the degree of transformation of fcc iron depends on the level of the shock. For a given shock level the resultant magnetic properties depend on the particle size distribution, with maximum effects noted in specimens with 400 to 600 A particles.

Wasilewski, P. J.

Evolving Magnetic Structures and Their Relation to Coronal Mass Ejections

Solar activity regions are frequently concentrated into cluster which persist for many solar rotations. These activity complexes are associated with weak dispersed magnetic fields which are most apparent after the activity itself has ceased. We call this combination of persistent activity and dispersed Evolving Magnetic Structures (EMS). Here we show examples of EMSs and describe the evolution of an EMS associated with major Coronal Mass Ejections (CME) and other solar and magnetic disturbances.

magnetic activity

Annealing effects in plated-wire memory elements. II - Recrystallization in Permalloy films.

Results of grain-size measurements in Permalloy platings suggest that recrystallization is possible at temperatures as low as 200 C, but that it is an extremely heterogeneous process. No worthwhile correlation was found to exist between observed grain size and magnetic dispersion in samples aged in the temperature range from 180 to 230 C. It is suggested that the magnetic aging which occurs under these conditions may be due to some other diffusion-controlled process than recrystallization; a process such as chemical homogenization is tentatively preferred.

Marquardt, S. J.

Magnetically oriented nanosheet interlayer for dynamic regeneration in lithium metal batteries

Lithium (Li) metal has been recognized as a promising anode to advance the energy density of current Li-based batteries. However, the growth of the solid–electrolyte interphase (SEI) layer and dendritic Li microstructure pose significant challenges for the long-term operation of Li metal batteries (LMBs). Herein, we propose the utilization of a suspension electrolyte with dispersed magnetically responsive nanosheets whose orientation can be manipulated by an external magnetic field during cell operation for realizing in situ regeneration in LMBs. The regeneration mechanism arises from the redistribution of the ion flux and the formation of an inorganic-rich SEI for uniform and compact Li deposition. With the magnetic-field-induced regeneration process, we show that a Li||Li symmetric cell stably operates for 350 h at 2 mA cm −2 and 2 mA h cm −2 , ~5 times that of the cell with the pristine electrolyte. Furthermore, the cycling stability can be significantly extended in the Li||NMC full cell of 3 mA h cm −2 , showing a capacity retention of 67% after 500 cycles at 1C. The dynamic Li metal regeneration demonstrated here could bring useful design considerations for reviving the operating cells for achieving high-energy, long-duration battery systems.

Ju, Zhengyu

Spin dynamics in the itinerant antiferromagnet SrCr 2 ⁢As 2

SrCr 2 ⁢As 2 is an itinerant antiferromagnet in the same structural family as the SrFe 2 ⁢As 2 high-temperature superconductors. Here, we report our calculations of exchange-coupling parameters 𝐽 𝑖⁢𝑗 for SrCr 2 ⁢As 2 using a static linear-response method based on first-principles electronic-structure calculations. We find that the dominant nearest-neighbor exchange coupling 𝐽 1 >0 is antiferromagnetic whereas the next-nearest-neighbor exchange coupling 𝐽 2 <0 is ferromagnetic with 𝐽 2 /𝐽 1 = −0.68, reinforcing the checkerboard in-plane magnetic structure. Thus, unlike other transition-metal arsenides based on Mn, Fe, or Co, we find no competing magnetic interactions in SrCr 2 ⁢As 2 , which aligns with experimental findings. Moreover, the orbital resolution of exchange interactions shows that 𝐽 1 and 𝐽 2 are dominated by direct exchange mediated by the Cr 𝑑 orbitals. To validate the calculations we conduct inelastic neutron-scattering measurements on powder samples that show steeply dispersive magnetic excitations arising from the magnetic Γ points and persisting up to energies of at least 175 meV. The spin-wave spectra are then modeled using the Heisenberg Hamiltonian with the theoretically calculated exchange couplings. In conclusion, the calculated neutron-scattering spectra are in good agreement with the experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Annealing effects in plated-wire memory elements. I - Interdiffusion of copper and Permalloy.

Results of investigations using X-ray diffraction and electron-beam microprobe techniques have shown that copper and Permalloy platings interdiffuse at low temperatures when plated-wire memory elements are annealed for times as short as 50 hr. Measurable interdiffusion between Permalloy platings and gold substrates does not occur in similar conditions. Both magnetic and compositional changes during aging are found to occur by a thermally activated process with activation energies around 38 kcal/mol. It is shown, however, that copper-diffusion and magnetic-dispersion changes during aging are merely concurrent processes, neither being the other's cause.

Knudson, C. I.

MAVEN Observations of Energy-Time Dispersed Electron Signatures in Martian Crustal Magnetic Fields

Energy-time dispersed electron signatures are observed by the Mars Atmosphere and Volatile EvolutioN (MAVEN) mission in the vicinity of strong Martian crustal magnetic fields. Analysis of pitch angle distributions indicates that these dispersed electrons are typically trapped on closed field lines formed above strong crustal magnetic sources. Most of the dispersed electron signatures are characterized by peak energies decreasing with time rather than increasing peak energies. These properties can be explained by impulsive and local injection of hot electrons into closed field lines and subsequent dispersion by magnetic drift of the trapped electrons. In addition, the dispersed flux enhancements are often bursty and sometimes exhibit clear periodicity, suggesting that the injection and trapping processes are intrinsically time dependent and dynamic. These MAVEN observations demonstrate that common physical processes can operate in both global intrinsic magnetospheres and local crustal magnetic fields.

martian

Nuclear Magnetic Resonance Dynamics of LiTFSI–Pyrazole Eutectic Solvents

Deep Eutectic Solvents (DESs) have emerged as promising candidates to replace conventional organic solvents in various technological applications due to their low vapor pressure, non-flammability, and ease of preparation at low costs. In particular, Type IV DESs, which are composed of metal salts and hydrogen bond donors, are possible replacements for lithium-ion battery electrolytes. In this study, we investigate the molecular dynamics of solvents of lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) and pyrazole (PYR) at varying LiTFSI:PYR molar ratios (1:2, 1:3, 1:4, 1:5) using Nuclear Magnetic Resonance Dispersion (NMRD) and Pulsed Field Gradient (PFG) Nuclear Magnetic Resonance (NMR). PFG NMR reveals composition-dependent diffusion trends, while NMRD provides molecular-level insights into the longitudinal relaxation rate (R 1 = 1/T 1 ). Notably, the LiTFSI:PYR (1:2) sample shows distinct behavior across both techniques, exhibiting enhanced relaxation rates and lower self-diffusion for 1 H compared to the other nuclei ( 19 F and 7 Li), suggestive of stronger and more efficient Li + –pyrazole interactions, as confirmed by the modeling of the relaxation profiles. Our study advances understanding of ion dynamics in azole-based eutectic solvents, supporting their potential use in safer battery electrolytes.

FFC-NMR

High fidelity simulations of contaminant dispersion in an urban environment with comparison to magnetic resonance imaging measurements

The dispersion of a contaminant in an urban environment has the potential to impact a large population of people. In this work, a complex urban canopy flow based on the Oklahoma City downtown business district circa 2003 is studied using Magnetic Resonance Imaging (MRI) and high-fidelity Large Eddy Simulations (LES). MRI is a novel experimental technique that can provide high-resolution measurements in four dimensions (three spatial and temporal) for lab scale models. The experiments and simulations use the same geometry and boundary conditions providing a one-to-one comparison of the two methods. Results are presented on the time-averaged velocity and concentration fields, the temporal dynamics of the concentration plumes for a transient release, and a novel Cloud Identification Algorithm that can separate plumes produced by periodic contaminant releases used for ensemble averaging over many releases. The MRI and LES datasets both include millions of measurement voxels and the comparisons highlight the complex 3D nature of the flow including strong vertical velocities in spanwise street canyons and flow acceleration in streamwise street canyons. The concentration fields are qualitatively similar albeit the LES shows larger dispersion. A quantitative analysis with performance measures compares the datasets pointwise and demonstrates that the two 3D datasets are similar with respect to many measures including a fractional bias of 0.02 (ideal=0.0), correlation coefficient of 0.87 (ideal = 1.0), and the fraction points within a factor of 2 is 0.98 (ideal = 1.0). Plume analysis compares the arrival and residence time of contaminant and is found to vary significantly with location within the urban environment with arrival times between 0 and 1.25 and differences within the contaminant cloud less than 10% at most locations.

54 ENVIRONMENTAL SCIENCES

Pulsar rotation and dispersion measures and the galactic magnetic field.

Use of observations of pulsar polarization and pulse time of arrival at frequencies between 250 and 500 MHz to determine rotation and dispersion measures for 19 and 21 pulsars, respectively. These measurements have been used to calculate mean line-of-sight components of the magnetic field in the path to the pulsars. These and other observations show that there is probably no contribution to the observed rotation measure from the pulsar itself. Low-latitude, low-dispersion pulsars are observed to have strong field components, and a strong dependence of rotation-measure sign on galactic longitude has been found. The observations are consistent with a relatively uniform field of about 3.5 microgauss directed toward about l = 90 deg in the local region, but appear to be inconsistent with the helical model for the local field.

Manchester, R. N.

Recovery of nonferrous metals from scrap automobiles by magnetic fluid levitation.

Ferrofluids are colloidal dispersions of subdomain magnetic solids in carrier liquids. In the presence of a non-homogeneous magnetic field, ferrofluids exert a pressure on immersed nonmagnetic objects in the opposite sense of the field gradient. This pressure force can, when opposite to gravity, levitate objects of higher density than the ferrofluid. This levitation technique can be used to separate solids according to density. Its application to the separation of nonferrous metals from shredded automobiles has been demonstrated on a prototype of a full-scale separator. Its use to recover nonferrous metals from municipal solid wastes also seems practical.

Mir, L.

Magneto-gravity waves

Small amplitude low frequency waves in plasma of infinite conductivity under influence of constant external gravitational and magnetic fields

ATMOSPHERIC CONDUCTIVITY

Plasma waves in a relativistic, strongly anisotropic plasma propagated along a strong magnetic field

The dispersion properties of plasma waves in a relativistic homogeneous plasma propagated along a strong magnetic field are studied. It is shown that the non-damping plasma waves exist in the frequency range omega sub p or = omega or = omega sub L. The values of omega sub p and omega sub L are calculated for an arbitrary homogeneous relativistic function of the particle distribution. In the case of a power ultrarelativistic distribution, it is shown that, if the ultrarelativistic tail of the distribution drops very rapidly, slightly damping plasma waves are possible with the phase velocity (omega/K)c.

Onishchenko, O. G.