Search NASA⌕ Search

SEARCH · Search NASA

Results for “MECS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Synergistic Thermo-Microbial-Electrochemical (T-MEC) Approach for Drop-In Fuel Production from Wet Waste

This project successfully developed and demonstrated the synergistic thermo-microbial-electrochemical (T-MEC) process, converting food waste into sustainable biofuels while achieving self-sustaining wastewater treatment and hydrogen production. By integrating hydrothermal liquefaction (HTL) and microbial electrolysis cells (MECs), the project advanced waste-to-fuel technology and expanded the understanding of sustainable waste valorization. It established a scalable framework for achieving high carbon efficiency, effective pollutant removal, and energy recovery, showcasing the potential of combining biological, thermal, and electrochemical systems to optimize resource recovery and reduce environmental impacts. The project demonstrated the technical effectiveness of the T-MEC process, achieving over 50% improvement in carbon efficiency and reducing waste processing costs by more than 25% compared to anaerobic digestion (AD). The HTL pilot reactor processed food waste at 90 kg/h, producing up to 200 L/day of biocrude oil with high conversion efficiency. A critical desalting step in pretreatment prevented catalyst fouling, enabling efficient hydrotreating with 100% deoxygenation and denitrogenation and sulfur reduction to <15 ppm. This positioned the kerosene fraction as a strong candidate for sustainable aviation fuel (SAF). The MECs achieved rapid startup, 86.4% COD removal, and hydrogen production rates of 1.8 L H 2 /L cat /day, among the highest recorded for pilot-scale systems. The integrated process achieved 65% carbon efficiency to biocrude and 58% to finished fuels, outperforming AD's 41% and 33% efficiencies for biogas and natural gas vehicle fuels. System analysis highlighted economic potential, with minimum fuel selling prices (MFSP) decreasing from $\$$25/GGE at 5 tpd to $\$$10/GGE at 500 tpd due to economies of scale. Future work will focus on reducing MEC material and membrane costs, enhancing performance through higher current densities, and creating tailored operational strategies for diverse feedstocks. Optimization of the integrated system will improve scalability and feasibility, positioning the T-MEC process as a competitive solution for converting wet waste into sustainable fuels and clean water. Beyond its technical and economic achievements, the project offers significant public benefits. The T-MEC process provides a sustainable alternative to landfilling and incineration, reducing greenhouse gas emissions and conserving resources. Converting waste into SAF and renewable fuels supports decarbonization in the transportation sector, advancing energy independence and reducing reliance on fossil fuels. Additionally, the process minimizes environmental pollutants, transforming them into valuable products like hydrogen and fuels, contributing to a cleaner and more sustainable future.

09 BIOMASS FUELS↗

Optical damage considerations in the design of the matter in extreme condition upgrade (MEC-U) laser systems

The Matter in Extreme Conditions Upgrade (MEC-U) project is a major upgrade to the MEC instrument of the LINAC Coherent Light Source (LCLS) X-ray free electron laser (XFEL) user facility at SLAC National Accelerator Laboratory. Here, the envisioned MEC upgrade will significantly enhance the capabilities of the pump laser sources in current MEC experimental station, boosting the energy of the nanosecond shock driver from 100 J to the kJ level, and increasing the power and repetition rate of the short pulse laser from 25 TW at 5 Hz to 1 PW at 10 Hz rate. Building such high energy/power pump laser systems presents challenges to minimize and mitigate against laser-induced optical damage. Here, as part of the system design, we have identified the optics at high-risk to damage and we have designed the laser systems to mitigate against these damage risks to ensure sustained facility operation.

Coating↗

MEC modeling

2p-2h interactions are crucial for describing ν-Ar scattering, especially in the "dip region" between the Quasi-Elastic (QE) peak and Δ-resonance production. They involve the ejection of two nucleons, leading to two holes in the nuclear ground state. The underlying nuclear dynamics involve short-range correlations (SRC), long-range correlations (Random Phase Approximation, RPA), and the interplay of one- and two-body currents. Several models attempt to describe 2p-2h interactions like Valencia and SuSAv2-MEC. Despite progress, discrepancies exist between models and with data. I Will give an overview of 2p2h from the perspective of two Models Valencia and SuSAv2-MEC. I will introduce my current work to apply reweighting from SuSAv2 to Valencia on argon which will help improving the systematic uncertainty on MEC for SBN and DUNE.

Hassinin, Karim [Houston U.] (ORCID:00090009778353↗

Modeling 2p-2h Interactions in Neutrino-Nucleus Scattering: A Comparative Overview of the Valencia and SuSAv2-MEC Models

2p-2h interactions are crucial for describing ν-A scattering, especially in the "dip region" between the Quasi-Elastic (QE) peak and Δ-resonance production. They involve the ejection of two nucleons, leading to two holes in the nuclear ground state. The underlying nuclear dynamics involve short-range correlations (SRC), long-range correlations (Random Phase Approximation, RPA), and the interplay of one- and two-body currents. Several models attempt to describe 2p-2h interactions, including Microscopic Models (e.g., Valencia), Scaling-Based Models (e.g., SuSAv2-MEC), and Transport Models (e.g., GiBUU). Despite progress, discrepancies exist between models and with data. I Will give an overview of 2p2h from the perspective of two Models Valencia and SuSAv2-MEC.

Hassinin, Karim [Houston U.]↗

The MEC-U Project at LCLS

Here, we describe the Matter in Extreme Conditions Upgrade (MEC-U) project, co-locating kilojoule long pulse and high repetition rate petawatt lasers with LCLS in a new experimental hall at SLAC National Accelerator Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Laboratory and Field Arrays: Technical Report for Performance Enhancement for Marine Energy Converter (MEC) Arrays (Task 5)

Task 5 consisted of two parts, wave energy converter (WEC) arrays and current energy converter (CEC) arrays. The two parts of the project were executed independently, and this report covers only the work on WECs. In this part of the task, the team characterized the behavior of and developed control schemes for wave energy converter (WEC) arrays that improved performance (i.e., maximized aggregate power generation and reduced the levelized cost of energy) over baseline, non-coordinated control approaches. Specifically, for WEC arrays: the team developed optimal layouts of arrays that considered the effect of WEC placement within an array on coordinated array control with real-time estimation schemes. The numerical codes developed through this task were made available to users for array design. These tools utilized existing commercial software as well as software developed within the project team.

13 HYDRO ENERGY↗

Kansas City, Missouri, Streetlight Electric Vehicle Charging: Strategies and challenges for site selection of streetlight electric vehicle infrastructure in Kansas City, Missouri (Final Report)

Public streetlight charging, whether on streets in central business districts or residential areas, provides easy charging access for apartment residents and homeowners alike. While most electric vehicle (EV) drivers charge at home, they do so in garages or on driveways they own. For renters and residents of multifamily housing (MFH), however, this may not be an option. EVs have a lower cost of ownership compared to conventional vehicles, and a used EV may be an affordable option for a lower-income household. But without easy access to charging, even a low-cost used EV may not be an option for a prospective buyer. An affordable curbside charging network has the potential to expand EV adoption into neighborhoods that have to date seen minimal interest and uptake of the technology and associated charging infrastructure. Streetlight charging networks can provide an economical, scalable, and effective approach to providing equitable and convenient charging. Metropolitan Energy Center (MEC) is dedicated to the mission of creating resource efficiency, environmental health, and economic vitality in the Kansas City region and beyond. Since 1983, MEC has provided resources, outreach, and training to make alternative fuels and energy efficiency commonplace. MEC led a streetlight charging pilot project that installed limited EV charging infrastructure on the streetlight system in Kansas City, Missouri, to demonstrate and test the benefits of curbside charging for EVs at existing on-street parking locations. The project aimed to cost-effectively expand the charging network in Kansas City to support residential charging and provide infrastructure in one or more charging deserts throughout the city. This pilot evaluates the impact and overall success of streetlight charging based on community feedback, utilization of charging infrastructure, technical feasibility, and cost. The project has pursued a data- and community-driven site selection process designed to identify sites with high demand and high opportunity for EV charging. This project was funded by the U.S. Department of Energy (DOE) and awarded to MEC through a competitive proposal process. The novelty and complexity of this project required an organization that could facilitate collaboration across levels of government, community members, and industry partners. For the past 25 years, through Kansas City Regional Clean Cities, MEC has worked with numerous public and private fleets on a variety of projects to improve the environmental performance and efficiency of the regional vehicle fleet. To advance affordable, efficient, and clean transportation efforts, DOE Clean Cities and Communities coalitions create local networks of public and private sector stakeholders and engage communities. Rooted within their local communities, the coalitions serve as experts and ambassadors, bringing to bear the collective knowledge, experience, and practical know-how of the entire network from within DOE, its national laboratories, and diverse stakeholders in the field. MEC and its project partners made in-kind contributions to leverage federal dollars for the benefit of the Kansas City community. Findings from this project will help determine the best applications for streetlight charging technologies to maximize funding impact and serve community needs. The team evaluated locations based on expected charging demand, technical feasibility, safety considerations, and enhanced charging network siting needs. Throughout the project, the team gathered feedback and evaluated ways to make public charging for EVs available to all community members. The insights will help Kansas City and other communities streamline future efforts to support EV drivers through public charging in the city right-of-way. Furthermore, this project will inform citywide guidance for future installations. MEC is committed to a transparent and publicly accessible approach that encourages the collaborative evaluation of streetlight charging. The project has engaged the community to proactively identify and evaluate the benefits and impacts of streetlight charging. It was a priority for the project to ensure the benefits of this pilot are distributed equitably to all members of the Kansas City community and that new charging opportunities and associated resources are available in diverse neighborhoods across the city. The charging infrastructure supports an affordable curbside charging network that will enable more drivers to choose EVs and provide easy charging access for all community members interested in driving an EV. The community feedback received through this project informed future resources and opportunities to make EVs more accessible to all members of the Kansas City community. MEC worked with several community partners on this project, including Missouri University of Science and Technology (MST), Pennsylvania State University (Penn State), the National Renewable Energy Laboratory (NREL); the city of Kansas City, Missouri; Evergy; Black and McDonald (B&M); LilyPad EV; EVNoire; and Westside Housing Organization (WHO). Project partners contributed to the cost match required for DOE grants through capital expenditures, personnel, and other in-kind contributions. Detailed descriptions of project team organizations can be found in Appendix A. Project Partners. Analysts at NREL and MST/PennState developed site maps based on demand and equity considerations. MEC conducted outreach to community members to garner input on project design and site selection, and received approval from the Missouri Public Service Commission (PSC) for Evergy’s EV charging station ownership. MEC worked with all partners to gather additional siting criteria and developed a site selection evaluation checklist, and partners conducted site visits to proposed installation sites. Next, B&M, Evergy, and the city executed all site agreements, conducted site-specific engineering design, acquired associated permits, and issued notices to proceed site by site or in small batches. Finally, from January to April 2023, the project team installed 23 EV charging stations built on Kansas City’s streetlight system in six council districts. Evergy will own, operate, and monitor the stations for 10 years, sharing charging data with MEC for at least 1 year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IL-1β is a key inflammatory cytokine that weakens lactation-specific tight junctions of mammary epithelial cells

Highlights: • TNF-α, IL-1β, and IL-6 directly affect tight junctions of MECs in different ways. • IL-1β rapidly disrupts tight junctions at tricellular contacts between MECs. • IL-1β decreases the amount of tight junction proteins and weaken the TJ barrier. • Activation of p38 by IL-1β triggers disruption of tight junctions. In lactating mammary glands, alveolar mammary epithelial cells (MECs) produce milk and form less-permeable tight junctions (TJs). However, alveolar TJs are weakened with a reduction in milk production in mammary glands due to mastitis or weaning in the presence of high levels of IL-1β, IL-6, or TNF-α. In this study, using in vitro cultured model of MECs with milk-producing ability and lactation-specific TJs, we investigated whether the aforementioned cytokines affect MEC TJs. The results showed that TNF-α, IL-1β, and IL-6 affected lactation-specific TJs in different ways. In particular, upon activation of p38 and JNK signalling, IL-1β caused rapid disruption of TJs at tricellular contact points. IL-1β treatment led to decreased CLDN3, CLDN4, and OCLN levels and a weakened TJ barrier. The adverse effects of IL-1β on TJs were mimicked by anisomycin, which is an activator of p38 and JNK signalling, and were blocked by MEC pretreatment with a p38 inhibitor but not a JNK inhibitor. The mislocalization of tricellulin at tricellular contact areas was confirmed in MECs treated with IL-1β or anisomycin. These results indicate that IL-1β is a key cytokine that adversely affects the TJs between MECs by activating p38.

60 APPLIED LIFE SCIENCES↗

Performance and community structure dynamics of microbial electrolysis cells operated on multiple complex feedstocks

Microbial electrolysis is a promising technology for converting aqueous wastes into hydrogen. However, substrate adaptability is an important feature, seldom documented in microbial electrolysis cells (MECs). In addition, the correlation between substrate composition and community structure has not been well established. This study used an MEC capable of producing over 10 L/L-day of hydrogen from a switchgrass-derived bio-oil aqueous phase and investigated four additional substrates, tested in sequence on a mature biofilm. The additional substrates included a red oak-derived bio-oil aqueous phase, a corn stover fermentation product, a mixture of phenol and acetate, and acetate alone. The MECs fed with the corn stover fermentation product resulted in the highest performance among the complex feedstocks, producing an average current density of 7.3 ± 0.51 A/m 2 , although the acetate fed MECs outperformed complex substrates, producing 12.3 ± 0.01 A/m 2 . 16S rRNA gene sequencing showed that community structure and community diversity were not predictive of performance, and replicate community structures diverged despite identical inoculum and enrichment procedure. The trends in each replicate, however, were indicative of the influence of the substrates. Geobacter was the most dominant genus across most of the samples tested, but its abundance did not correlate strongly to current density. High-performance liquid chromatography (HPLC) showed that acetic acid accumulated during open circuit conditions when MECs were fed with complex feedstocks and was quickly degraded once closed circuit conditions were applied. The largest net acetic acid removal rate occurred when MECs were fed with red oak bio-oil aqueous phase, consuming 2.93 ± 0.00 g/L-day. Principal component analysis found that MEC performance metrics such as current density, hydrogen productivity, and chemical oxygen demand removal were closely correlated. Net acetic acid removal was also found to correlate with performance. However, no bacterial genus appeared to correlated to these performance metrics strongly, and the analysis suggested that less than 70% of the variance was accounted for by the two components. This study demonstrates the robustness of microbial communities to adapt to a range of feedstocks and conditions without relying on specific species, delivering high hydrogen productivities despite differences in community structure. The results indicate that functional adaptation may play a larger role in performance than community composition. Further investigation of the roles each microbe plays in these communities will help MECs to become integral in the 21st-century bioeconomy to produce zero-emission fuels.

09 BIOMASS FUELS↗

First report of Staphylococcus pseudintermedius ST71-SCCmec III and ST45-ΨSCCmec57395 from canine pyoderma in Argentina

Abstract Staphylococcus pseudintermedius is an opportunistic pathogen commonly associated with skin infections in dogs. Twenty-three methicillin-resistant S. pseudintermedius (MRSP) isolated in Argentina from dogs with pyoderma were analyzed using whole genome sequencing (WGS) and classified into sequence types (ST) by multilocus sequence typing (MLST) and staphylococcal chromosome cassette mec (SCC mec ) types. Based on the WGS analysis, MLST, and SCC mec type results, we report for the first time in Argentina two MRSP strains, one each, belonging to ST71-SCC mec III and ST45-ΨSCC mec 57395 from dogs with pyoderma. We also identified seven isolates with ST339, which had been previously reported in only two isolates in Argentina. Additionally, we identified ten MRSP isolates harboring variants of the SCC mec V found in S. aureus , seven SCC mec V (5C2&5) with two ccr C1 recombinases, and three SCC mec V (5C2) with one ccr C1 recombinase. Our findings provide important insights into the evolution and geographic spread of these hypervirulent dominant clones that threaten the health of our companion animals and represent a significant risk for zoonotic infections.

Srednik, Mariela E.↗

Enabling microbial electrolysis cell scale-up via electrochemistry-, hydrodynamic-, and microbial ecology-informed framework

Microbial electrolysis cells (MECs) can produce green hydrogen while removing organic contaminants from liquid waste streams by leveraging the metabolic activity of electroactive microorganisms. Despite their potential in a sustainable, circular economy, large-scale MECs that can treat relevant volumes of wastewater have failed to deliver performance proportional to their lab-scale counterparts. The reason behind this lower performance at scale remains unclear. Here, in this study, we developed a combined electrochemistry-, hydrodynamic-, and microbial ecology-informed framework to analyze and optimize MEC performance during scale-up, enabling accurate quantification of major limitations and the identification of strategies to overcome them, ultimately facilitating equivalent performance at scale. Applying this framework to the scale-up of a zero-gap MEC from 9 cm 2 electrode area to 100 cm 2 electrode area, resulted in similar maximum current densities in a 100 cm 2 MEC (21.7 ± 1.1 A/m 2 ) compared to a 9 cm 2 system (25.1 ± 2.7 A/m 2 ), as well as equivalent hydrogen production rates of 69.3 L/L-d (100 cm 2 ) and 67.7 ± 2.4 L/L-d (9 cm 2 ). COMSOL flow dynamics simulations were used to scale up the reactor configuration without negatively affecting electrolyte velocity and distribution in the cell, minimizing the increase in internal resistances during scale-up (11.7 ± 0.5 mΩm 2 at 9 cm 2 ; 19.7 ± 1.3 mΩm 2 at 100 cm 2 ). Microbial community structures were assessed at both scales using high-throughput sequencing, highlighting the differences of populations across electrode dimensions and operational parameters. The framework presented here accelerates the development of effective strategies toward the scale-up of MECs by furthering the understanding of how electrochemical, hydrodynamic, and microbial ecology parameters change as the reactor dimension is increased. Ultimately, this approach contributes to advancing electrochemical biotechnology toward practical deployment in energy-efficient wastewater treatment systems.

Flow path↗

Scalable membrane-less microbial electrolysis cell with multiple compact electrode assemblies for high performance hydrogen production

Bioelectrochemical hydrogen production via microbial electrolysis cells (MECs) is a promising method for sustainable energy production and decarbonization of energy systems. However, the application of MECs is limited by the electrochemical performance, scalability, and the cost associated with expensive materials. Here, in this study, a scalable MEC (500 mL) with novel compact electrode assemblies and high electrode surface area to volume ratio (160 m 2 /m 3 ) was designed and constructed. The use of membranes, precious metal catalyst, and current collectors with high costs was avoided. A high current density at the steady state of 49.5 ± 5.3 A/m 2 was achieved using acetate as the substrate with phosphate buffer under the applied voltage of 1.01 V. The corresponding volumetric current density was 3948 ± 422 A/m 3 . The compact electrode assembly design limited methane production rate to 3.9 ± 0.2 L/L/D, while achieving a hydrogen production rate of 33.7 ± 1.7 L/L/D. With the suppression of microbial hydrogen consumption, the hydrogen production rate was 39.8 ± 1.9 L/L/D, higher by almost one order of magnitude than those of MECs with scaling up attempts. The compact electrode configuration reduced internal resistance to 88.5 ± 4.4 Ω cm 2 . The energy efficiency based on input electricity was 146 ± 7 % to 189 ± 9 % within the applied voltage range of 0.71 to 1.05 V. The results in this study demonstrated successful scaling up of high performance small MECs and offered a new possible approach of scaling up MECs by stacking high-performance subunits, with no trade-offs on electrochemical performance.

08 HYDROGEN↗

Impact of reactor architecture and design parameters on the performance of microbial electrolysis cells revealed by the electrode potential slope analysis

Microbial electrolysis cells (MECs) are appealing for recovering the chemical energy contained in domestic and industrial liquid wastes as hydrogen gas. Despite several years of research in the field, there is still a lack of critical analysis of how the reactor architecture dictates the electrochemical performance of the cell. In this study, internal resistance and onset voltage from the electrode potential slope analysis (EPS) were used in combination with current density, hydrogen production rate, reactor packing density, electrode spacing, membrane type and composition from 23 different studies to identify the reactor design parameters that primarily govern electrochemical performance of MECs. Using anion exchange membranes resulted in smaller internal resistances (AEM R int = 41± 40 mΩ m 2 ) and larger current density (18 ± 14 A m −2 ) compared to single chamber reactors (SC R int = 68 ± 58 mΩ m 2 ; 22 ± 16 A m −2 ) or MECs with cation exchange membranes (CEM R int = 376 ± 280 mΩ m 2 ; 3.0 ± 2.1 A m −2 ). Higher electrochemical performance for AEM- and SC-MECs translated in larger hydrogen gas production rates (0.122 mL H 2 C −1 for AEM vs 0.117 mL H 2 C −1 for SC), but only when inhibitors against hydrogen scavengers were added in single chamber systems (0.080 mL H 2 C −1 for SC without inhibitors). Following membrane type and composition, maintaining a small electrode spacing was the most critical parameter to improve MEC performance, indicating that the low conductivity of the media primarily limit performance by increasing ohmic resistance. Here, reactor volume and electrode surface area negatively correlated with internal resistance and current density, indicating that better performance of scaled-up reactors can likely be obtained by stacking multiple smaller units rather than just increasing reactor size. Although challenges remain in the implementation of MECs for hydrogen production from liquid wastes, advances in electrochemical engineering of the reactors can facilitate scale up and performance prediction at scale.

Electrochemistry↗

Hydrogen production from full-strength corn stover fermentation effluent in single-chamber replaceable-cathode microbial electrolysis cells

Lignocellulosic residual biomass generated by the agricultural sector is an abundant feedstock for biohydrogen production via dark fermentation. However, this process is intrinsically inefficient, converting only ~30% of the reductant energy into H2 and leaving substantial amounts of reduced byproducts. These byproducts, mostly found in the fermentation effluents, can be further valorized in microbial electrolysis cells (MECs) to enhance the overall H2 recovery. However, current MEC configurations are typically dual- or single-chamber systems, yet both suffer from key inefficiencies. Dual-chamber systems rely on proton exchange membranes that are costly and prone to rapid biofouling, whereas single-chamber, membraneless systems are limited by reduced productivity due to H2 recycling and methanogenic consumption In this study, three single-chamber, 50-mL replaceable-cathode microbial electrolysis cells (RC-MECs) were 3D-printed and equipped with a physical separator to isolate anode and cathode compartments and limit H2 migration. Full-strength milled corn stover (MCS) fermentation effluent (COD of ~23.8 g-COD/L) was treated in fed-batch mode over two operational periods spanning 21 (Run 1) and 80 (Run 2) days. The RC-MECs exhibited comparable performance in both runs: after biofilm maturation, current densities exceeded 100 A/m²_cathode, COD removal reached up to 43%. Notably, extended RC-MECs operation led to a substantial methanogenic activity with the CH4 fraction in the cathode gas increasing to as high as 80% of the total biogas. Additions of a methanogenesis inhibitor 2-bromoethanesulfonate (2-BES) produced transient increases in hydrogen yields (11.51 and 5.12 L-H2/L_reactor/day in Runs 1 and 2, respectively); however, sustained 2-BES addition in subsequent cycles reduced total biogas production, decreased COD removal, and led to volatile fatty acid accumulation. Overall, single-chamber MECs can treat high-strength dark fermentation effluents while improving H2 recovery, but methanogenesis remains a key bottleneck, and complete long-term inhibition may be operationally unsustainable.

Hydrogen Production↗

Vapor-Fed Cathode Microbial Electrolysis Cells with Closely Spaced Electrodes Enables Greatly Improved Performance

Hydrogen can be electrochemically produced in microbial electrolysis cells (MECs) by current generated from bacterial anodes with a small added voltage. MECs typically use a liquid catholyte containing a buffer or salts. However, anions in these catholytes result in charge being balanced predominantly by ions other than hydroxide or protons, leading to anode acidification. To enhance only hydroxide ion transport to the anode, we developed a novel vapor-fed MEC configuration lacking a catholyte with closely spaced electrodes and an anion exchange membrane to limit the acidification. This MEC design produced a record-high sustained current density of 43.1 ± 0.6 A/m 2 and a H 2 production rate of 72 ± 2 LH 2 /L-d (cell voltage of 0.79 ± 0.00 V). There was minimal impact on MEC performance of increased acetate concentrations, solution conductivity, or anolyte buffer capacity at applied voltages up to 1.1 V, as shown by a nearly constant internal resistance of only 6.8 ± 0.3 mΩ m 2 . At applied external voltages >1.1 V, the buffer capacity impacted performance, with current densities increasing from 28.5 ± 0.6 A/m 2 (20 mM phosphate buffer solution (PBS)) to 51 ± 1 A/m 2 (100 mM PBS). Furthermore, these results show that a vapor-fed MEC can produce higher and more stable performance than liquid-fed cathodes by enhancing transport of hydroxide ions to the anode.

anion exchange membrane↗

Impact of Fermentation-Derived Substrates on Hydrogen Production in Zero-Gap Microbial Electrolysis Cells

Zero-gap microbial electrolysis cells (MECs) represent a promising platform for hydrogen production from liquid waste streams due to reduced interelectrode spacing that lowers internal resistance and enhances mass transport. However, the performance and stability of zero-gap MECs treating chemically complex feedstocks remain insufficiently characterized. Here, we operated zero-gap MECs with real, unamended, corn stover dark fermentation effluent containing a wide range of organic substrates. The MECs fed fermentation effluent achieved a maximum current density of 24 A/m2 (15+-6 A/m2 over the cycle) and a hydrogen production rate of 75 L/L-d (42+-19 L/L-d over the cycle). The substrates were consumed at different rates, indicating substrate-selective utilization by the anodic microbial community. Acetate supported high and stable current generation, whereas ethanol, formate, lactate, and amino acids induced varying degrees of inhibition depending on their concentration. Residual sugars caused pronounced current fluctuations, consistent with ongoing fermentation and local pH changes. A diverse microbial community was crucial for efficiently utilizing complex organics and maximizing electrochemical performance. These results demonstrate how and to what extent substrate composition regulates zero-gap MEC performance and that microbial community and operational conditions can be leveraged to enhance performance. These novel findings provide practical guidance for achieving robust hydrogen recovery from chemically heterogeneous real liquid waste streams.

08 HYDROGEN↗