Search NASA⌕ Search

SEARCH · Search NASA

Results for “MM algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

CMPLE: Correlation Modeling to Decode Photosynthesis Using the Minorize–Maximize Algorithm

In plant genomic experiments, correlations among various biological traits (phenotypes) give new insights into how genetic diversity may have tuned biological processes to enhance fitness under diverse conditions. Consequently, knowing how the correlations are affected by genetic (G) and environmental (E) factors helps develop climate-resilient plants. However, the current literature lacks any method for assessing the effect of predictors on pairwise correlations among multiple phenotypes together with easily interpretable model parameters. To address this need, we propose to model pairwise correlations directly in terms of G and E and develop a computationally efficient inference procedure. Two major novelties in our methodology are (1) the use of a composite pairwise likelihood method to avoid the positive definiteness restriction on the correlation matrix and (2) the use of a novel Minorize–Maximize (MM) algorithm for the efficient estimation of a large number of parameters. The proposed method shows excellent numerical performance on synthetic datasets. Here, the analysis of the motivating data on cowpea reveals that the rates of solar energy storage by photosynthesis (the aggregate trait) are differentially affected by different genetic loci through two distinct processes: “photoinhibition” which results from photodamage caused by excess light, and “photoprotection” which protects plants from photodamage but also results in energy loss.

Correlation modeling↗

Graph Sparsification by Approximate matrix Multiplication

Graphs arising in statistical problems, signal processing, large networks, combinatorial optimization, and data analysis are often dense, which causes both computational and storage bottlenecks. One way of sparsifying a weighted graph, while sharing the same vertices as the original graph but reducing the number of edges, is through spectral sparsification. We study this problem through the perspective of RandNLA. Specifically, we utilize randomized matrix multiplication to give a clean and simple analysis of how sampling according to edge weights gives a spectral approximation to graph Laplacians, without requiring spectral information. Through the CR–MM algorithm, we attain a simple and computationally efficient sparsifier whose resulting Laplacian estimate is unbiased and of minimum variance. Here, we define a new notion of additive spectral sparsifiers, which has not been considered in the literature.

97 MATHEMATICS AND COMPUTING↗

A method for volumetric imaging in radiotherapy using single x-ray projection

Purpose: It is an intriguing problem to generate an instantaneous volumetric image based on the corresponding x-ray projection. The purpose of this study is to develop a new method to achieve this goal via a sparse learning approach. Methods: To extract motion information hidden in projection images, the authors partitioned a projection image into small rectangular patches. The authors utilized a sparse learning method to automatically select patches that have a high correlation with principal component analysis (PCA) coefficients of a lung motion model. A model that maps the patch intensity to the PCA coefficients was built along with the patch selection process. Based on this model, a measured projection can be used to predict the PCA coefficients, which are then further used to generate a motion vector field and hence a volumetric image. The authors have also proposed an intensity baseline correction method based on the partitioned projection, in which the first and the second moments of pixel intensities at a patch in a simulated projection image are matched with those in a measured one via a linear transformation. The proposed method has been validated in both simulated data and real phantom data. Results: The algorithm is able to identify patches that contain relevant motion information such as the diaphragm region. It is found that an intensity baseline correction step is important to remove the systematic error in the motion prediction. For the simulation case, the sparse learning model reduced the prediction error for the first PCA coefficient to 5%, compared to the 10% error when sparse learning was not used, and the 95th percentile error for the predicted motion vector was reduced from 2.40 to 0.92 mm. In the phantom case with a regular tumor motion, the predicted tumor trajectory was successfully reconstructed with a 0.82 mm error for tumor center localization compared to a 1.66 mm error without using the sparse learning method. When the tumor motion was driven by a real patient breathing signal with irregular periods and amplitudes, the average tumor center error was 0.6 mm. The algorithm robustness with respect to sparsity level, patch size, and presence or absence of diaphragm, as well as computation time, has also been studied. Conclusions: The authors have developed a new method that automatically identifies motion information from an x-ray projection, based on which a volumetric image is generated.

60 APPLIED LIFE SCIENCES↗

SU-E-T-519: Investigation of the CyberKnife MultiPlan Monte Carlo Dose Calculation Using EBT3 Film Absolute Dosimetry for Delivery in a Heterogeneous Thorax Phantom

Purpose To characterize the Cyberknife (CK) robotic system’s dosimetric accuracy of the delivery of MultiPlan’s Monte Carlo dose calculations using EBT3 radiochromic film inserted in a thorax phantom. Methods The CIRS XSight Lung Tracking (XLT) Phantom (model 10823) was used in this study with custom cut EBT3 film inserted in the horizontal (coronal) plane inside the lung tissue equivalent phantom. CK MultiPlan v3.5.3 with Monte Carlo dose calculation algorithm (1.5 mm grid size, 2% statistical uncertainty) was used to calculate a clinical plan for a 25-mm lung tumor lesion, as contoured by the physician, and then imported onto the XLT phantom CT. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0– 800 cGy. The test films (n=3) were irradiated using 325 cGy to the prescription point. Films were scanned 48 hours after irradiation using an Epson v700 scanner (48 bits color scan, extracted red channel only, 96 dpi). Percent absolute dose and relative isodose distribution difference relative to the planned dose were quantified using an in-house QA software program. Multiplan Monte Carlo dose calculation was validated using RCF dosimetry (EBT3) and gamma index criteria of 3%/3mm and 2%/2mm for absolute dose and relative isodose distribution measurement comparisons. Results EBT3 film measurements of the patient plans calculated with Monte Carlo in MultiPlan resulted in an absolute dose passing rate of 99.6±0.4% for the Gamma Index of 3%/3mm, 10% dose threshold, and 95.6±4.4% for 2%/2mm, 10% threshold criteria. The measured central axis absolute dose was within 1.2% (329.0±2.5 cGy) of the Monte Carlo planned dose (325.0±6.5 cGy) for that same point. Conclusion MultiPlan’s Monte Carlo dose calculation was validated using the EBT3 film absolute dosimetry for delivery in a heterogeneous thorax phantom.

60 APPLIED LIFE SCIENCES↗

SU-E-I-13: Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images

Purpose: A new commercially available metal artifact reduction (MAR) software in computed tomography (CT) imaging was evaluated with phantoms in the presence of metals. The goal was to assess the ability of the software to restore the CT number in the vicinity of the metals without impacting the image quality. Methods: A Catphan 504 was scanned with a GE Optima RT 580 CT scanner (GE Healthcare, Milwaukee, WI) and the images were reconstructed with and without the MAR software. Both datasets were analyzed with Image Owl QA software (Image Owl Inc, Greenwich, NY). CT number sensitometry, MTF, low contrast, uniformity, noise and spatial accuracy were compared for scans with and without MAR software. In addition, an in-house made phantom was scanned with and without a stainless steel insert at three different locations. The accuracy of the CT number and metal insert dimension were investigated as well. Results: Comparisons between scans with and without MAR algorithm on the Catphan phantom demonstrate similar results for image quality. However, noise was slightly higher for the MAR algorithm. Evaluation of the CT number at various locations of the in-house made phantom was also performed. The baseline HU, obtained from the scan without metal insert, was compared to scans with the stainless steel insert at 3 different locations. The HU difference between the baseline scan versus metal scan was improved when the MAR algorithm was applied. In addition, the physical diameter of the stainless steel rod was over-estimated by the MAR algorithm by 0.9 mm. Conclusion: This work indicates with the presence of metal in CT scans, the MAR algorithm is capable of providing a more accurate CT number without compromising the overall image quality. Future work will include the dosimetric impact on the MAR algorithm.

60 APPLIED LIFE SCIENCES↗

Component pose reconstruction using a single robotic total station for panelized building envelopes

The construction industry can benefit greatly from increased automation in construction processes in terms of precision, time, and labor costs. This is especially true for prefabricated construction for either new buildings or envelope retrofits. Here, prefabricated components are manufactured offsite according to design specifications and installed onsite. Accurate information on the component’s position and orientation (pose) is needed to achieve this. A tool named “Real-Time Evaluator” (RTE), designed to autonomously track prefabricated components as they are being installed and provide real-time installation instructions, is currently under development using a single robotic total station. This is challenging since at least three points are needed to determine the pose of an object in space. To achieve this goal with a single robotic total station, two key algorithms were developed: the “resection” algorithm aligns the digital twin with the physical twin regardless of the location of the total station, and the “transformation” algorithm gives instructions of translations and rotations to installers to achieve the desired installation pose. The algorithms were evaluated experimentally on a lab-scale demonstration. Results show that the resection algorithm achieved an average error of < 3.1 mm, while the transformation algorithm predicted the rotation angle along a single axis with an error of < 0.5◦.

Tang, Mengjia↗

SU-F-T-626: Intracranial SRS Re-Treatment Without Acquisition of New CT Images

Purpose: Linear accelerator based stereotactic radiosurgery (SRS) for multiple intracranial lesions with frequent surveillance is becoming a popular treatment option. This strategy leads to retreatment with SRS as new lesions arise. Currently, each course of treatment uses magnetic resonance (MR) and computed tomography (CT) images for treatment planning. We propose that new MR images, with course 1 CT images, may be used for future treatment plans with negligible loss of dosimetric accuracy. Methods: Ten patients that received multiple courses of SRS were retrospectively reviewed. The treatment plans and contours from non-initial courses were copied to the initial CTs and recalculated. Doses metrics for the plans calculated on the initial CTs and later CTs were compared. All CT scans were acquired on a Philips CT scanner with a 600 mm field of view and 1 mm slice thickness (Philips Healthcare, Andover, MA). All targets were planned to 20 Gy and calculated in Eclipse V. 13.6 (Varian, Palo Alto, CA) using analytic anisotropic algorithm with 1 mm calculation grid. Results: Sixteen lesions were evaluated. The mean time between courses was 250 +/− 215 days (range 103–979). The mean target volume was 2.0 +/− 2.9 cc (range 0.1–10.1). The average difference in mean target dose between the two calculations was 0.2 +/− 0.3 Gy (range 0.0 – 1.0). The mean conformity index (CI) was 1.28 +/− 0.14 (range 1.07 – 1.82). The average difference in CI was 0.03 +/− 0.16 (range 0.00 – 0.44). Targets volumes < 0.5 cc showed the largest changes in both metrics. Conclusion: Continued treatment based on initial CT images is feasible. Dose calculation on the initial CT for future treatments provides reasonable dosimetric accuracy. Changes in dose metrics are largest for small volumes, and are likely dominated by partial volume effects in target definition.

60 APPLIED LIFE SCIENCES↗

Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers

Purpose: To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. Methods: Twenty-two consecutive patients were enrolled in a prospective trial examining 10-fraction APBI. Titanium clips were implanted intraoperatively around the seroma in all patients. For image-registration, the positions of the clips in daily kV x-ray images were matched to those in the planning digitally reconstructed radiographs. Fiducial and gravity registration errors (FREs and GREs, respectively), representing resulting misalignments of the edge and center of the target, respectively, were compared between the manual and algorithm-based methods. Results: In total, 218 fractions were evaluated. Although the mean FRE/GRE values for the manual and algorithm-based methods were within 3 mm (2.3/1.7 and 1.3/0.4 mm, respectively), the percentages of fractions where FRE/GRE exceeded 3 mm using the manual and algorithm-based methods were 18.8%/7.3% and 0%/0%, respectively. Manual registration resulted in 18.6% of patients with fractions of FRE/GRE exceeding 5 mm. The patients with larger clip deviation had significantly more fractions showing large FRE/GRE using manual registration. Conclusions: For image-registration using fiducial markers in APBI, the manual registration results in more fractions with considerable registration error due to loss of fiducial objectivity resulting from their deviation. The authors recommend the PRBR algorithm as a safe and effective strategy for accurate, image-guided registration and PTV margin reduction.

60 APPLIED LIFE SCIENCES↗

SU-E-T-141: Automated Dose Point Placement for Cervical Cancer Brachytherapy Using Tandem and Ovoid Applicators

Purpose: To develop a standalone application, which automatically and consistently calculates the coordinates of points A and H based solely on the implanted applicator geometry for cervical cancer HDR brachytherapy. Methods: Manchester point A and ABS point H are both located 2cm lateral from the central tandem plane. While both points are located 2cm above the cervical os, surrogates for the os differ. Point A is defined relative to the anatomical cervical os. Point H is defined relative to the intersection of the tandem with the superior aspects of the ovoids. The application takes an input text file generated by the treatment planning system (TPS, BrachyVision, Varian) that specifies the source geometries. It then outputs the 3D coordinates of points A and H in both the left and right directions. The algorithm was implemented and tested on 34 CT scans of 7 patients treated with HDR brachytherapy delivered using tandem and ovoids. A single experienced user retrospectively and manually placed points A and H on the CT scans, whose coordinates were used as the gold standard for the comparison to the automatically calculated points. Results: The automatically calculated coordinates of points A and H agree within 0.7mm with the gold standard. The averages and standard deviations of the 3D coordinate difference between points placed by the two methods are 0.3±0.1 and 0.4±0.1mm for points A and H, respectively. The maximum difference in 3D magnitude is 0.7mm. Conclusion: The algorithm consistently calculates dose point coordinates independently of the planner for cervical cancer brachytherapy treated with tandem and ovoids. Automated point placement based on the geometry of the implanted applicators agrees in sub-millimeter with careful manual placements by an experienced user. This algorithm expedites the planning process and eliminates dependencies on either user input or TPS visualization tools.

60 APPLIED LIFE SCIENCES↗

The high matrix acquisition technique for imaging of atherosclerotic plaque inflammation in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography with time-of-flight: Phantom study

Background: Motion artifact and partial volume effect caused underestimation of coronary plaque inflammation. This study evaluated the high matrix acquisition technique using time-of-flight (TOF) positron emission tomography/computed tomography for imaging of atherosclerotic plaque inflammation with fluorine-18 fluorodeoxyglucose in small and moving phantoms. Methods and Results: All images were reconstructed using a conventional algorithm without TOF (4 × 4 × 4 mm{sup 3} voxel size) and a high matrix algorithm with TOF (2 × 2 × 2 mm{sup 3} voxel size). Microsphere phantoms of 10, 7.9, 6.2, 5.0, and 4.0 mm diameters were acquired in 3-dimensional list-mode for 30 minutes. A heart phantom mimicking cardiac motion consisted of a hot spot simulating a plaque (φ 4 mm, φ 2 mm) on the outside of the left ventricle. In the microsphere and heart phantom study, visual discrimination, maximum activity, and target-to-background ratio using the high matrix algorithm with TOF were better than those using the conventional algorithm without TOF. Conclusion: The high matrix algorithm with TOF improves detection of small targets in phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRA-01: A Procedure for the Fast Semi-Automatic Localization of Catheters Using An Electromagnetic Tracker (EMT) for Image-Guided Brachytherapy

Purpose: To evaluate the feasibility of brachytherapy catheter localization through use of an EMT and 3D image set. Methods: A 15-catheter phantom mimicking an interstitial implantation was built and CT-scanned. Baseline catheter reconstruction was performed manually. An EMT was used to acquire the catheter coordinates in the EMT frame of reference. N user-identified catheter tips, without catheter number associations, were used to establish registration with the CT frame of reference. Two algorithms were investigated: brute-force registration (BFR), in which all possible permutation of N identified tips with the EMT tips were evaluated; and signature-based registration (SBR), in which a distance matrix was used to generate a list of matching signatures describing possible N-point matches with the registration points. Digitization error (average of the distance between corresponding EMT and baseline dwell positions; average, standard deviation, and worst-case scenario over all possible registration-point selections) and algorithm inefficiency (maximum number of rigid registrations required to find the matching fusion for all possible selections of registration points) were calculated. Results: Digitization errors on average <2 mm were observed for N ≥5, with standard deviation <2 mm for N ≥6, and worst-case scenario error <2 mm for N ≥11. Algorithm inefficiencies were: N = 5, 32,760 (BFR) and 9900 (SBR); N = 6, 360,360 (BFR) and 21,660 (SBR); N = 11, 5.45*1010 (BFR) and 12 (SBR). Conclusion: A procedure was proposed for catheter reconstruction using EMT and only requiring user identification of catheter tips without catheter localization. Digitization errors <2 mm were observed on average with 5 or more registration points, and in any scenario with 11 or more points. Inefficiency for N = 11 was 9 orders of magnitude lower for SBR than for BFR. Funding: Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

Universal test fixture for monolithic mm-wave integrated circuits calibrated with an augmented TRD algorithm

The design and evaluation of a novel fixturing technique for characterizing millimeter wave solid state devices is presented. The technique utilizes a cosine-tapered ridge guide fixture and a one-tier de-embedding procedure to produce accurate and repeatable device level data. Advanced features of this technique include nondestructive testing, full waveguide bandwidth operation, universality of application, and rapid, yet repeatable, chip-level characterization. In addition, only one set of calibration standards is required regardless of the device geometry.

Romanofsky, Robert R.↗

SU-F-T-167: Measurement of Proton Beam Spot Size Using a 2D Ion Chamber Array for Daily QA

Purpose: To develop an algorithm which can calculate the Full Width Half Maximum (FWHM) of a Proton Pencil Beam from a 2D dimensional ion chamber array (IBA Matrixx) with limited spatial resolution ( 7.6 mm inter chamber distance). The algorithm would allow beam FWHM measurements to be taken during daily QA without an appreciable time increase. Methods: Combinations of 147 MeV single spot beams were delivered onto an IBA Matrixx and concurrently on EBT3 films for a standard. Data were collected around the Bragg Peak region and evaluated by a custom MATLAB script based on our algorithm using a least squared analysis. A set of artificial data, modified with random noise, was also processed to test for robustness. Results: The Matlab script processed Matixx data shows acceptable agreement (within 5%) with film measurements with no single measurement differing by more than 1.8 mm. In cases where the spots show some degree of asymmetry, the algorithm is able to resolve the differences. The algorithm was able to process artificial data with noise up to 15% of the maximum value. Time assays of each measurement took less than 3 minutes to perform, indicating that such measurements may be efficiently added to daily QA treatment. Conclusion: The developed algorithm can be implemented in daily QA program for Proton Pencil Beam scanning beams (PBS) with Matrixx to extract spot size and position information. The developed algorithm may be extended to small field sizes in photon clinic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced techniques for transverse vorticity measurements

A four wire array of probes is used to determine the velocity components, their derivatives, and the transverse vorticity in a small (approximately 1 x 1 mm) spatial domain. The algorithms that define this calculation scheme and the extended considerations: compensating for minor calibration changes, uncertainty considerations, and the determination of excessive pitch angles in the data set, are presented.

Foss, J. F.↗

GPM Ground Validation at NASA Wallops Precipitation Research Facility

The Wallops Precipitation Research Facility (WPRF) at NASA Goddard Space Flight Center, Wallops Island, VA has been established as a semi-permanent super-site for the Global Precipitation Measurement (GPM) Ground Validation (GV) program. WPRF is home to research quality precipitation instruments, including NASA’s S-band dual-polarimetric radar (NPOL), and a network of profiling radars, disdrometers, and rain gauges. This study investigates the statistical agreement of the GPM Core Observatory Dual Frequency Precipitation Radar (DPR), combined DPR-GPM Microwave Imager (GMI) and GMI Level II precipitation retrievals compared to WPRF ground observations from a six-year collection of satellite overpasses. Multi-sensor observations are integrated using the System for Integrating Multiplatform Data to Build the Atmospheric Column (SIMBA) software package. SIMBA ensures measurements recorded in a variety of formats are synthesized into a common reference frame for ease in comparison and analysis. Given that instantaneous satellite measurements are observed above ground level, this study investigates the possibility of a time lag between satellite and surface mass-weighted mean diameter (D(sub m)), reflectivity (Z), and precipitation rate (R) observations. Results indicate that time lags vary up to 30 minutes after overpass time but are not consistent between cases. In addition, GPM Core D(sub m) retrievals are within Level I mission science requirements as compared to WPRF ground observations. Results also indicate GPM algorithms overestimate light rain (< 1.0 mm hr(exp -1)). Two very different stratiform rain vertical profiles show differing results when compared to ground reference data. A key finding of this study indicates multi-sensor DPR/GMI combined algorithms outperform single sensor DPR algorithm.

Charanjit S Pabla↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 11: Quantification of chest wall motion during deep inspiration breast hold treatments using cine EPID images and a physics based algorithm

Purpose: This work presents an algorithm used to quantify intra-fraction motion for patients treated using deep inspiration breath hold (DIBH). The algorithm quantifies the position of the chest wall in breast tangent fields using electronic portal images. Methods: The algorithm assumes that image profiles, taken along a direction perpendicular to the medial border of the field, follow a monotonically and smooth decreasing function. This assumption is invalid in the presence of lung and can be used to calculate chest wall position. The algorithm was validated by determining the position of the chest wall for varying field edge positions in portal images of a thoracic phantom. The algorithm was used to quantify intra-fraction motion in cine images for 7 patients treated with DIBH. Results: Phantom results show that changes in the distance between chest wall and field edge were accurate within 0.1 mm on average. For a fixed field edge, the algorithm calculates the position of the chest wall with a 0.2 mm standard deviation. Intra-fraction motion for DIBH patients was within 1 mm 91.4% of the time and within 1.5 mm 97.9% of the time. The maximum intra-fraction motion was 3.0 mm. Conclusions: A physics based algorithm was developed and can be used to quantify the position of chest wall irradiated in tangent portal images with an accuracy of 0.1 mm and precision of 0.6 mm. Intra-fraction motion for patients treated with DIBH at our clinic is less than 3 mm.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-02: Attenuation Correction in 4D-PET Using a Single-Phase Attenuation Map

Purpose: 4D-PET imaging has been proposed as a potential solution to the respiratory motion effect in thoracic region. CT-based attenuation correction (AC) is an essential step toward quantitative imaging for PET. However, due to the temporal difference of 4D-PET and a single breath-hold CT, motion artifacts are observed in the attenuation-corrected PET images that can lead to error in tumor shape and uptake. We introduce a practical method for aligning single-phase CT to all other 4D-PET phases using a penalized non-rigid demons registration. Methods: Individual 4D-PET frames were reconstructed without AC. Non-rigid Demons registration was used to derive deformation vector fields (DVFs) between the PET matched with CT phase and other 4D-PET images. While attenuated PET images provide enough useful data for organ borders such as lung and liver, tumors are not distinguishable from background due to loss of contrast. To preserve tumor shape in different phases, from CT image an ROI covering tumor was excluded from non-rigid transformation. Mean DVF of the central region of the tumor was assigned to all voxels in the ROI. This process mimics a rigid transformation of tumor along with a non-rigid transformation of other organs. 4D XCAT phantom with spherical tumors in lung with diameters ranging from 10 to 40 mm was used to evaluate the algorithm. Results: Motion related induced artifacts in attenuation-corrected 4D-PET images were significantly reduced. For tumors smaller than 20 mm, non-rigid transformation was capable to provide quantitative results. However, for larger tumors, where tumor self-attenuation is considerable, our combined method yields superior results. Conclusion: We introduced a practical method for deforming a single CT to match all 4D-PET images for accurate AC. Although 4D-PET data include insignificant anatomical information, we showed that they are still useful to estimate DVFs for aligning attenuation map and accurate AC.

60 APPLIED LIFE SCIENCES↗