Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microsurgery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Robotic Assisted Microsurgery - RAMS FY'97

JPL and Microdexterity Systems collaborated to develop new surgical capabilities. They developed a Robot Assisted Microsurgery (RAM) tool for surgeons to use for operating on the eye, ear, brain, and blood vessels with unprecedented dexterity. A surgeon can hold the surgical instrument with motions of 6 degrees of freedom with an accuracy of 25 microns in a 70 cu cm workspace. In 1996 a demonstration was performed to remove a microscopic particle from a simulated eyeball. In 1997, tests were performed at UCLA to compare telerobotics with mechanical operations. In 5 out of 7 tests, the RAM tool performed with a significant improvement of preciseness over mechanical operation. New design features include: (1) amplified forced feedback; (2) simultaneous slave robot instrumentation; (3) index control switch on master handle; and (4) tool control switches. Upgrades include: (1) increase in computational power; and (2) installation of hard disk memory storage device for independent operation and independent operation of forceps. In 1997 a final demonstration was performed using 2 telerobotics simultaneously in a microsurgery suture procedure to close a slit in a thin sheet of latex rubber which extended the capabilities of microsurgery procedures. After completing trials and demonstrations for the FDA the potential benefits for thousands of operations will be exposed.

Source record↗

Telerobotics for Microsurgery

None given. Covers recent advances in robotics and their applicaiton to microsurgery.

telerobotics robotics medicine surgery robot assis↗

Results of Neoadjuvant Short-Course Radiation Therapy Followed by Transanal Endoscopic Microsurgery for T1-T2 N0 Extraperitoneal Rectal Cancer

Purpose: This study was undertaken to assess the short-term outcomes of neoadjuvant short-course radiation therapy (SCRT) followed by transanal endoscopic microsurgery (TEM) for T1-T2 N0 extraperitoneal rectal cancer. Recent studies suggest that neoadjuvant radiation therapy followed by TEM is safe and has results similar to those with abdominal rectal resection for the treatment of extraperitoneal early rectal cancer. Methods and Materials: We planned a prospective pilot study including 25 consecutive patients with extraperitoneal T1-T2 N0 M0 rectal adenocarcinoma undergoing SCRT followed by TEM 4 to 10 weeks later (SCRT-TEM). Safety, efficacy, and acceptability of this treatment modality were compared with historical groups of patients with similar rectal cancer stage and treated with long-course radiation therapy (LCRT) followed by TEM (LCRT-TEM), TEM alone, or laparoscopic rectal resection with total mesorectal excision (TME) at our institution. Results: The study was interrupted after 14 patients underwent SCRT of 25 Gy in 5 fractions followed by TEM. Median time between SCRT and TEM was 7 weeks (range: 4-10 weeks). Although no preoperative complications occurred, rectal suture dehiscence was observed in 7 patients (50%) at 4 weeks follow-up, associated with an enterocutaneous fistula in the sacral area in 2 cases. One patient required a colostomy. Quality of life at 1-month follow-up, according to European Organization for Research and Treatment of Cancer QLQ-C30 survey score, was significantly worse in SCRT-TEM patients than in LCRT-TEM patients (P=.0277) or TEM patients (P=.0004), whereas no differences were observed with TME patients (P=.604). At a median follow-up of 10 months (range: 6-26 months), we observed 1 (7%) local recurrence at 6 months that was treated with abdominoperineal resection. Conclusions: SCRT followed by TEM for T1-T2 N0 rectal cancer is burdened by a high rate of painful dehiscence of the suture line and enterocutaneous fistula, compared to TEM alone and TEM following LCRT, which forced us to stop the study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual finger boosts three-dimensional imaging and microsurgery as well as terabyte volume image visualization and analysis

Three-dimensional (3D) bioimaging, visualization and data analysis are in strong need of powerful 3D exploration techniques. We develop virtual finger (VF) to generate 3D curves, points and regions-of-interest in the 3D space of a volumetric image with a single finger operation, such as a computer mouse stroke, or click or zoom from the 2D-projection plane of an image as visualized with a computer. VF provides efficient methods for acquisition, visualization and analysis of 3D images for roundworm, fruitfly, dragonfly, mouse, rat and human. Specifically, VF enables instant 3D optical zoom-in imaging, 3D free-form optical microsurgery, and 3D visualization and annotation of terabytes of whole-brain image volumes. VF also leads to orders of magnitude better efficiency of automated 3D reconstruction of neurons and similar biostructures over our previous systems. We use VF to generate from images of 1,107 Drosophila GAL4 lines a projectome of a Drosophila brain.

59 BASIC BIOLOGICAL SCIENCES↗

Noncontact microsurgery of cell membranes using femtosecond laser pulses for optoinjection of specified substances into cells

IR femtosecond laser pulses were used for microsurgery of a cell membrane aimed at local and short-duration change in its permeability and injection of specified extracellular substances into the cells. The possibility of noncontact laser delivery of the propidium iodide fluorescent dye and the pEGFP plasmid, encoding the green fluorescent protein, into the cells with preservation of the cell viability was demonstrated. (extreme light fields and their applications)

60 APPLIED LIFE SCIENCES↗

Dexterity enhancement in microsurgery using telemicro-robotics

The presentation will focus on finding the spectrum of dexterity performance while performing microsurgery in various specialties. It will be noted that individuals vary markedly in their performance in the position, velocity, stability, and force domains. There are surgeons who have a tremor who otherwise move very slowly and carefully while there are other surgeons who apply excessive force, but never have a tremor or move excessively fast. There are yet other surgeons who move excessively fast, yet they do not have a tremor. Dexterity enhancement includes position down scaling, tremor filtering, fatigue elimination, and other second-order issues such as confining the work space, velocities, accelerations, or forces. It will be described that the hand's position performance is degraded when it is asked to actuate the tools and that remote actuation alone increases the positioning capabilities. It will be noted that rotary and telescopic functions are far more difficult than writing or engraving-like motions. The safety issues concerning velocities and forces will be discussed and the need for impedance control pointed out. Simplistically, the devices should be made with variable compliance so that they can function rigidly as a robot would or compliantly as a human would, depending on the setting of this parameter. Tool interfaces will be discussed with an emphasis on the overall performance of the position, end effector, and tool as a unit. Space constraints, force, and velocity requirements will be discussed in this section as well. Referencing the coordinate system to pre- or inter-operative imaging systems will be discussed as well as an emphasis on the system architecture.

Charles, Steve↗

Dexterity-Enhanced Telerobotic Microsurgery

The work reported in this paper is the result, of a collaboration between researchers at the Jet Propulsion Laboratory and Steve Charles, MD, a vitreo-retinal surgeon. The Robot Assisted MicroSurgery (RAMS) telerobotic workstation developed at JPL is a prototype of a system that will be completely under the manual control of a surgeon. The system has a slave robot that will hold surgical instruments. The slave robot motions replicate in six degrees of freedom those of tile. surgeon's hand measured using a master input device with a surgical instrument, shaped handle. The surgeon commands motions for the instrument by moving the handle in the desired trajectories. The trajectories are measured, filtered, and scaled down then used to drive the slave robot.

Charles, Steve↗

Tool actuation and force feedback on robot-assisted microsurgery system

An input control device with force sensors is configured to sense hand movements of a surgeon performing a robot-assisted microsurgery. The sensed hand movements actuate a mechanically decoupled robot manipulator. A microsurgical manipulator, attached to the robot manipulator, is activated to move small objects and perform microsurgical tasks. A force-feedback element coupled to the robot manipulator and the input control device provides the input control device with an amplified sense of touch in the microsurgical manipulator.

Das, Hari↗

Laser microsurgery of higher plant cell walls permits patch-clamp access

Plasma membranes of guard cells in epidermal peels of Vicia faba and Commelina communis can be made accessible to a patch-clamp pipet by removing a small portion (1-3 micrometers in diameter) of the guard cell wall using a microbeam of ultraviolet light generated by a nitrogen laser. Using this laser microsurgical technique, we have measured channel activity across plasma membranes of V. faba guard cells in both cell-attached and isolated patch configurations. Measurements made in the inside-out patch configuration revealed two distinct K(+)-selective channels. Major advantages of the laser microsurgical technique include the avoidance of enzymatic protoplast isolation, the ability to study cell types that have been difficult to isolate as protoplasts or for which enzymatic isolation protocols result in protoplasts not amenable to patch-clamp studies, the maintenance of positional information in single-channel measurements, reduced disruption of cell-wall-mediated signaling pathways, and the ability to investigate intercellular signaling through studies of cells remaining situated within tissue.

Non-NASA Center↗

Robot Assisted Microsurgery Development at JPL

A team of engineers at JPL, working in collaboration with MicroDexterity Systems, Inc., and Dr. Steve Charles, recently developed a telerobotic workstation to assist microsurgeons perform surgery.

Microsurgery JPL telerobotic MicroDexterity System↗

Femtosecond lasers for microsurgery of cornea

The review of femtosecond laser installations for medical applications is given and a new femtosecond ophthalmologic system for creation of a flap of corneal tissue during the LASIK operation is described. An all-fibre femtosecond laser emitting {approx}400-fs pulses at 1067 nm is used. The pulse repetition rate can vary from 200 kHz up to 1 MHz. The output energy of the femtosecond system does not exceed 1 {mu}J. A specially developed objective with small spherical and chromatic aberrations is applied to focus laser radiation to an area of an eye cornea. The size of the focusing spot does not exceed 3 {mu}m. To process the required area, scanning by a laser beam is applied with a speed no less than 5 m s{sup -1}. At a stage of preliminary tests of the system, the {Kappa}8 glass, organic PMMA glass and specially prepared agarose gels are used as a phantom of an eye. The femtosecond system is successfully clinically tested on a plenty of eyes of a pig and on several human eyes. The duration of the procedure of creation of a corneal flap does not exceed 20 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Moving-Surface Follower Aids Microsurgery

Novel manipulator follows movements of arteries and muscles, enabling precise placement of probe or other microsurgical tool in moving tissue. Microprobe assembly is mounted on output of pneumatic servo of commercial noncontracting thickness gage. Pulsations of tissue surface to be penetrated by probe are sensed by gage and followed by servo, eliminating relative motion between tissue and probe.

Feldstein, C.↗

Measurement of hand dynamics in a microsurgery environment: Preliminary data in the design of a bimanual telemicro-operation test bed

Data describing the microsurgeon's hand dynamics was recorded and analyzed in order to provide an accurate model for the telemicrosurgery application of the Bimanual Telemicro-operation Test Bed. The model, in turn, will guide the development of algorithms for the control of robotic systems in bimanual telemicro-operation tasks. Measurements were made at the hand-tool interface and include position, acceleration and force between the tool-finger interface. Position information was captured using an orthogonal pulsed magnetic field positioning system resulting in measurements in all six degrees-of-freedom (DOF). Acceleration data at the hands was obtained using accelerometers positioned in a triaxial arrangement on the back of the hand allowing measurements in all three cartesian-coordinate axes. Force data was obtained by using miniature load cells positioned between the tool and the finger and included those forces experienced perpendicular to the tool shaft and those transferred from the tool-tissue site. Position data will provide a minimum/maximum reference frame for the robotic system's work space or envelope. Acceleration data will define the response times needed by the robotic system in order to emulate and subsequently outperform the human operator's tool movements. The force measurements will aid in designing a force-reflective, force-scaling system as well as defining the range of forces the robotic system will encounter. All analog data was acquired by a 16-channel analog-to-digital conversion system residing in a IBM PC/AT-compatible computer at the Center's laboratory. The same system was also used to analyze and present the data.

Charles, Steve↗