Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motor-Driven Pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Enhanced Component Performance Study: Motor-Driven Pumps 1998-2020

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR≤1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP frequency of start demands (demands per reactor year) • Standby MDP frequency of FTR≤1H hours (hours per reactor year) • Standby MDP frequency of FTR>1H hours • Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: • Standby MDP FTR≤1H failure probability • Normally running MDP FTR failure rate • Standby MDP unavailability • Normally running MDP total unreliability (8-hour mission) • Standby MDP frequency of FTR≤1H events (failures per reactor year) • Normally running MDP frequency of FTR events.

99 GENERAL AND MISCELLANEOUS↗

Modeling of Vertical Motor-driven Pump for Simulation of a Fault Signature \\ for Condition Monitoring

As part of the ongoing effort to transition from preventive maintenance strategies to condition-based maintenance strategies in nuclear power plants, there is significant reliance on using machine learning techniques. To develop a robust machine learning model that can diagnose all the fault modes of a vertical motor-driven pump, data capturing the unique signature of each fault mode is required. In practice, it is difficult to collect or capture data that captures all the fault modes from a single plant site. So to address this situation, a computational model of a vertical motor-driven pump is developed using the multipurpose finite element software COMSOL Multiphysics. The developed model is used to generate simulated data under normal operation and is compared with the vibration data collected using vibration sensors. Once the simulation model is verified under normal operating condition, simulated data for the fault mode for which minimal or no evidence is available in historical plant process data is developed. This simulated data is used to develop fault signatures to achieve robust predictive models. This paper presents modeling details and verification of the model that can used to generate data for fault modes that are not available at a plant site for condition monitoring purpose.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Modeling of Vertical Motor-driven Pump for Simulation of a Fault Signature \\ for Condition Monitoring

As part of the ongoing effort to transition from preventive maintenance strategies to condition-based maintenance strategies in nuclear power plants, there is significant reliance on using machine learning techniques. To develop a robust machine learning model that can diagnose all the fault modes of a vertical motor-driven pump, data capturing the unique signature of each fault mode is required. In practice, it is difficult to collect or capture data that captures all the fault modes from a single plant site. So to address this situation, a computational model of a vertical motor-driven pump is developed using the multipurpose finite element software COMSOL Multiphysics. The developed model is used to generate simulated data under normal operation and is compared with the vibration data collected using vibration sensors. Once the simulation model is verified under normal operating condition, simulated data for the fault mode for which minimal or no evidence is available in historical plant process data is developed. This simulated data is used to develop fault signatures to achieve robust predictive models. This paper presents modeling details and verification of the model that can used to generate data for fault modes that are not available at a plant site for condition monitoring purpose.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Development of a Compact Efficient Cooling Pump for Space Suit Life Support Systems

With the increasing demands placed on extravehicular activity (EVA) for the International Space Station (ISS) assembly and maintenance, along with planned lunar and Martian missions, the need for increased human productivity and capability becomes ever more critical. This is most readily achieved by reduction in space suit weight and volume, and increased hardware reliability, durability, and operating lifetime. Considerable progress has been made with each successive generation of space suit design; from the Apollo A7L suit, to the current Shuttle Extravehicular Mobile Unit (EMU) suit, and the next generation Constellation Space Suit Element (CSSE). However, one area of space suit design which has continued to lag is the fluid pump used to drive the water cooling loop of the Primary Life Support System (PLSS). The two main types of fluid pumps typically used in space applications are rotodynamic pumps (pumping is achieved through a rotary vaned impeller) and displacement pumps (which includes rotary and diaphragm pumps). The rotating and moving parts found in the pumps and electric motor add significantly to the susceptibility to wear and friction, thermal mismatch, and complexity of the pumps. Electric motor-driven pumps capable of achieving high operational reliability are necessarily large, heavy, and energy inefficient. This report describes a development effort conducted for NASA by Lynntech, Inc., who recently demonstrated the feasibility of an electrochemically-driven fluid cooling pump. With no electric motor and minimal lightweight components, an electrochemically-driven pump is expected to be significantly smaller, lighter and achieve a longer life time than conventional rotodynamic and displacement pumps. By employing sulfonated polystyrene-based proton exchange membranes, rather than conventional Nafion membranes, a significant reduction in the actuator power consumption was demonstrated. It was also demonstrated that these membranes possess the necessary mechanical strength, durability, and temperature range for long life space operation. The preliminary design for a Phase II prototype pump compares very favorably to the fluid cooling pumps currently used in space suit portable life support systems (PLSS). Characteristics of the electrochemically-driven pump are described and the benefits of the technology as a replacement for electric motor pumps in mechanically pumped single-phase fluid loops (MPFLs) is discussed.

vanBoeyen, Roger W.↗

Multi-Kernel Adaptive Support Vector Machine for Scalable Predictive Maintenance

Application of data-driven solutions across an industry is challenging, since the data are often stored locally, and increasing privacy and security concerns restrict access to the data. In addition, it is highly unlikely that all potential data patterns are captured in a single data source. Because it is highly unlikely that all potential data patterns are captured in a single data source, machine learning (ML) models developed from a single source cannot be robust enough. An alternative is to train the ML model at each source and develop a distributed knowledge discovery and aggregation approach to build global knowledge. In this paper, we develop and demonstrate a distributed ML model, federated transfer learning (FTL), using a multi-kernel-based adaptive support vector machine (MK-A-SVM). For federated learning (FL), the multi-kernel (MK) approach enables feature-specific model aggregation under data heterogeneity; whereas for transfer learning (TL) the adaptive model enables utilization of an aggregated model from a different task. The proposed approach is validated using nuclear power plant (NPP) vertical motor-driven pump data to predict the health condition of vertical motor-driven pumps as an anomaly detection. The efficiency of the proposed approach is also quantified and compared with neural network.

42 ENGINEERING↗

Enhanced Component Performance Study: Motor Driven Pumps 1998–2022

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP frequency of start demands (demands per reactor year), (2) Standby MDP frequency of FTR=1H hours (hours per reactor year), (3) Standby MDP frequency of FTR>1H hours, and (4) Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP FTR=1H failure probability, (2) Normally running MDP FTR failure rate, (3) Standby MDP unavailability, (4) Standby MDP total unreliability (8-hour mission), and (5) Normally running MDP total unreliability (8-hour mission).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Motor Driven Pumps 1998-2024

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cold startup and low temperature performance of the Brayton cycle electrical subsystem

Cold performance tests and startup tests were conducted on the Brayton-cycle inverter, motor-driven pump, dc supply, speed control with parasitic load resistor and the Brayton control system. These tests were performed with the components in a vacuum and mounted on coldplates. A temperature range of ?25 to -50 C was used for the tests. No failures occurred, and component performance gave no indication that there would be any problem with the safe operation of the Brayton power generating system.

Vrancik, J. E.↗

Deployable UHV Pump

This project presents an external motorized actuation system for a deployable ultra-high vacuum (UHV) pump, enabling internal motion without compromising vacuum conditions. All active components remain external due to environmental and space constraints. A motor-driven mechanical feedthrough transfers motion into the pump, supported by a modular, adjustable mounting system that maintains alignment and integrates with existing hardware. CAD modeling and iterative design were used to refine geometry and ensure proper fit. The final design reliably transfers motion while maintaining alignment and structural integrity. Its adjustability improves installation and maintenance, demonstrating a practical solution for actuation in UHV systems.

Remington, Austin [Northern Illinois U.]↗

Solar-powered Rankine heat pump for heating and cooling

The design, operation and performance of a familyy of solar heating and cooling systems are discussed. The systems feature a reversible heat pump operating with R-11 as the working fluid and using a motor-driven centrifugal compressor. In the cooling mode, solar energy provides the heat source for a Rankine power loop. The system is operational with heat source temperatures ranging from 155 to 220 F; the estimated coefficient of performance is 0.7. In the heating mode, the vapor-cycle heat pump processes solar energy collected at low temperatures (40 to 80 F). The speed of the compressor can be adjusted so that the heat pump capacity matches the load, allowing a seasonal coefficient of performance of about 8 to be attained.

Rousseau, J.↗