Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multi-zone model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Data reduction considerations for the burning velocity of spherical constant volume flames of R32 (CH 2 F 2 ) with air

Here, the present work explores data reduction techniques for the measurement of the laminar burning velocities of R32(CH 2 F 2 )-air mixtures using a constant volume combustion device, in which the pressure-time history is the only measured parameter. To allow clear assessment of the accuracy of the data reduction methods, the pressure-time histories used for analysis are synthetically generated via a detailed numerical simulation employing full kinetics and with and without an optically-thin radiation model. Various data reduction models are employed, including a two-zone model and two multi-zone models, and these are compared with the results from the burning velocity obtained from the output of the numerical simulation. The data reduction schemes are shown to be accurate if the same radiation model is employed in the data reduction as was used in the flame simulation to generate the pressure trace used for post-processing. If the incorrect radiation model is employed, however, the errors can be quite large. The effects of stretch, radiation, and different data post-processing methodologies are explored and the errors quantified. Stretch is shown to be important for the early stages and the selected data range that is used for extrapolation has a significant effect on the extrapolated burning velocity. However, with an appropriate choice of data considered for extrapolation, the prediction of the unstretched burning velocity can be quite accurate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physics vs structure: A systematic benchmark of learning strategies for multi-zone building thermal dynamics

Recent advances in physics-informed and data-driven machine learning promise improved thermal models for advanced building control, yet there is limited quantitative evidence on when added physics structure and architectural complexity are beneficial. Here, this work presents a systematic benchmark of five representative system identification methods for modeling multi-zone building thermal dynamics: linear state-space models, multi-layer perceptrons, neural state-space models, neural ordinary differential equations, and physically-consistent neural networks. The methods are evaluated across multiple data regimes and zone coupling strategies. Using a high-fidelity multi-zone commercial building emulator, we examine short-term and long-term prediction accuracy, computational efficiency, and ease of development. Our results reveal critical trade-offs between prediction performance, model complexity, and physical consistency. We demonstrate that decoupled, nonlinear black-box models consistently outperform coupled physics-constrained architectures in both predictive accuracy and out-of-distribution robustness in majority of the test cases for the building type considered in the study. Our findings quantify the cost of complexity in building thermal modeling and provide concrete, actionable, scenario-based guidelines for selecting model classes for control-oriented applications.

Building thermal modeling↗

Quantifying spatiotemporal variability in occupant exposure to an indoor airborne contaminant with an uncertain source location

Well-mixed zone models are often employed to compute indoor air quality and occupant exposures. While effective, a potential downside to assuming instantaneous, perfect mixing is underpredicting exposures to high intermittent concentrations within a room. When such cases are of concern, more spatially resolved models, like computational-fluid dynamics methods, are used for some or all of the zones. But, these models have higher computational costs and require more input information. A preferred compromise would be to continue with a multi-zone modeling approach for all rooms, but with a better assessment of the spatial variability within a room. Here to do so, we present a quantitative method for estimating a room's spatiotemporal variability, based on influential room parameters. Our proposed method disaggregates variability into the variability in a room's average concentration, and the spatial variability within the room relative to that average. This enables a detailed assessment of how variability in particular room parameters impacts the uncertain occupant exposures. To demonstrate the utility of this method, we simulate contaminant dispersion for a variety of possible source locations. We compute breathing-zone exposure during the releasing (source is active) and decaying (source is removed) periods. Using CFD methods, we found after a 30 minutes release the average standard deviation in the spatial distribution of exposure was approximately 28% of the source average exposure, whereas variability in the different average exposures was lower, only 10% of the total average. We also find that although uncertainty in the source location leads to variability in the average magnitude of transient exposure, it does not have a particularly large influence on the spatial distribution during the decaying period, or on the average contaminant removal rate. By systematically characterizing a room's average concentration, its variability, and the spatial variability within the room important insights can be gained as to how much uncertainty is introduced into occupant exposure predictions by assuming a uniform in-room contaminant concentration. We discuss how the results of these characterizations can improve our understanding of the uncertainty in occupant exposures relative to well-mixed models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based predictive control of multi-zone commercial building with a lumped building modelling approach

Here this study investigates the applicability of a lumped building modeling approach to model-based predictive control (MPC) to alleviate the complex modeling process of the grey-box multi-zone building model. Based on experimental data, two building models were estimated in this study. The detailed model as a reference case and a lumped model were estimated with decentralized and conventional approaches, respectively. Then, simulations were performed with two boundary conditions, including the comfort bound and electricity cost structure. The performances of the MPC with the detailed and lumped models were analyzed compared to the feedback control. More savings was achieved with a larger comfort bound and more aggressive electricity cost structure. The savings potential of the proposed lumped model approach was not as high as that of the detailed model. However, the proposed method yields good control performance, whose savings was approximately 8.6% over that of feedback control. These results suggest that the proposed method can be used to facilitate MPC implementation in multi-zone building applications.

42 ENGINEERING↗

Performance analysis and comparison of data-driven models for predicting indoor temperature in multi-zone commercial buildings

Building thermal models, which characterize the properties of a building’s envelope and thermal mass, are essential for accurate indoor temperature and cooling/heating demand prediction. Because of their flexibility and ease of use, data-driven models are increasingly used. Here, this study compared and analyzed the performance of gray-box (resistance-capacitance) and black-box (recurrent neural network) models for predicting indoor air temperature in a real multi-zone commercial building. The developed resistance-capacitance model served as a benchmark model for which full sets of temporal data and building information were used as inputs. The recurrent neural network models were trained and tested assuming various available types and amounts of temporal data and known building physical information to investigate the effects of data and information availability. Feature importance analysis was conducted to select the key variables for different prediction targets under different scenarios. This research provides guidance in selecting an appropriate building thermal response modeling method based on the measured data availability, building physical information, and application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new dynamic zOnal model with air-diffuser (DOMA) - Application to thermal comfort prediction

A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.

Construction & Building Technology↗

Broadband multiwavelength properties of the archetypal blazar 3C 279 during the 2017 Event Horizon Telescope campaign

The archetypal blazar 3C 279 hosts a prominent relativistic jet and exhibits strong broadband variability across the electromagnetic spectrum. In April 2017, the Event Horizon Telescope (EHT) observed 3C 279, alongside one of the most extensive quasi-simultaneous multiwavelength (MWL) campaigns ever conducted. With the aim of investigating the physical processes governing 3C 279, we analyzed individual observations and multiband light curves, and constructed a new quasi-simultaneous MWL spectrum. We also performed phenomenological modeling using the turbulent extreme multi-zone (TEMZ) model to constrain the fundamental physical properties of the source. The EHT observations reveal a clear flux increase in the innermost core between April 5 and 11, 2017. Over a broader timescale, radio measurements at longer wavelengths show concurrent enhancements in core flux and polarization around mid-April, coinciding with the ejection of a superluminal knot. Record UV-optical flares with strong polarization variability occurred in late March, followed by gamma-ray activity that declined before the end of the EHT observing period. During this interval, the source remained in a low X-ray state and showed no detectable VHE emission. The TEMZ modeling suggests that the broadband spectrum and variability of 3C 279 can be explained within a jet scenario in which turbulent plasma cells are compressed by a stationary conical shock. However, alternative interpretations, such as magnetic reconnection or a moving shock-in-jet event, remain plausible. This coordinated MWL campaign advances our understanding of the origin of jet and gamma-ray emission in 3C 279, while also providing a comprehensive publicly available dataset that will serve as a valuable reference for future studies.

Principe, G. [Trieste U.; INFN, Trieste; Bologna, ↗

First-principles-integrated Study of Blazar Synchrotron Radiation and Polarization Signatures from Magnetic Turbulence

Blazar emission is dominated by nonthermal radiation processes that are highly variable across the entire electromagnetic spectrum. Turbulence, which can be a major source of nonthermal particle acceleration, can widely exist in the blazar emission region. The Turbulent Extreme Multi-Zone (TEMZ) model has been used to describe turbulent radiation signatures. Recent particle-in-cell (PIC) simulations have also revealed the stochastic nature of the turbulent emission region and particle acceleration therein. However, radiation signatures have not been systematically studied via first-principles-integrated simulations. In this paper, we perform combined PIC and polarized radiative transfer simulations to study synchrotron emission from magnetic turbulence in the blazar emission region. We find that the multiwavelength flux and polarization are generally characterized by stochastic patterns. Specifically, the variability timescale and average polarization degree (PD) are governed by the correlation length of the turbulence. Interestingly, magnetic turbulence can result in polarization angle swings with arbitrary amplitudes and duration, in either direction, that are not associated with changes in flux or PD. Surprisingly, these swings, which are stochastic in nature, can appear either bumpy or smooth, although large-amplitude swings (>180°) are very rare, as expected. Our radiation and polarization signatures from first-principles-integrated simulations are consistent with the TEMZ model, except that in the latter, there is a weak correlation, with zero lag, between flux and degree of polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating Chemical Kinetics Predictions for Propane Using 3-D and 0-D Models in a Boosted Spark-Ignited Engine

Propane has been shown to be a promising alternative fuel to reduce emissions while simultaneously achieving high efficiencies in medium- and heavy-duty engines. These high-power density applications require boosted engines which, combined with high compression ratio, can lead to auto-ignition and knock. While three-dimensional (3-D) computational fluid dynamics (CFD) models are often used for resolving the complex fluid flow in engines, these models can become computationally expensive when simulating detailed chemical kinetics. Likewise, zero-dimensional (0-D) models are computationally concise enough for kinetics development, but lack any flow-field information which governs the flame propagation processes in spark ignition (SI) engines. This work presents a comprehensive comparison between 3-D and 0-D closed cycle simulations at knocking conditions in a high compression ratio high stroke-to-bore ratio propane engine. In order to initialize the flow-field for the 3-D closed cycle (intake valve closing, (IVC) to exhaust valve opening, (EVO)) simulation, a motored multi-cycle 3-D model was run using Converge to create a map at IVC, reducing the computational time. The map allowed a non-homogeneous 3-D closed cycle simulation to be satisfactorily validated against experiments, while a homogeneous case using only the turbulence field mapping was also simulated, mimicking 0-D modeling. The 3-D simulations were used to prescribe the initial conditions (e.g., IVC thermodynamics, speciation, burn-rate profile) for a 2-zone 0-D SI engine model in Chemkin Pro for both cases. It was found that 2-zone 0-D modeling underpredicted the knock onset timing, likely due to the lack of thermal stratification in the unburned gas region. Future work will carry multi-zone 0-D modeling to capture the fuel auto-ignition in the unburned region.

Douvry-Rabjeau, Julien [Oakland University, Roches↗

LBC (Learning Building Control)

LBC encompasses the source code and data to reproduce and extend results for a manuscript that compares demand responsive control schemes for multi-zone buildings. It includes examples of model predictive control (MPC), value function approximation via CVXPYLAYERS, and differentiable predictive control (DPC). The goal of the study is to evaluate state-of-the-art controllers and establish the efficacy (if any) of learning-based approaches that leverage deep neural networks in one way or another.

Zhang, Xiangyu↗

Online Dynamic Mode Decomposition Based System Identification of Multi-Zone Building HVAC Systems

Many works have recently been conducted to reduce the electricity consumption of smart buildings and allow them to support various grid services. Most of these works require accurate system models for the various appliances in the building including heating, ventilation, and air conditioning (HVAC) units. In this paper, we investigate a recursive data-driven system identification strategy to construct the thermal model for a time-varying building with a multi-zone HVAC unit. The online dynamic mode decomposition (DMD)-based strategy is employed to identify the multi-zone thermal building dynamics, where a simple information update (rank-1) is selected to avoid computational complexity. The DMD-based identification strategy is validated using a real gymnasium building equipped with a 4-zone HVAC unit, and its performance is compared with that of the traditional nuclear-norm subspace identification (N2SID) strategy.

Wu, Tumin [University of Tennessee, Knoxville (UTK↗

Hybrid combustion modeling approach for turbulent jet ignition in natural-gas pre-chamber spark-ignition engines at high EGR

Here, this study presented a hybrid modeling approach for simulating turbulent jet ignition and combustion processes in a natural-gas pre-chamber spark-ignition engine operating under exhaust gas recirculation (EGR) diluted conditions. In-depth analyses of experimental data and simulation results from previous work [Chinnathambi et al., ICEF2021-67836; Kim et al., Fuel 409: 137815, 2026] revealed two key findings: (i) the magnitude of pressure difference between the pre-chamber and main chamber ($∆P_{PC-MC}$) was positively correlated with the combustion duration from the moment of $∆P_{PC-MC}=0$ to the point of 5% mass fraction burned, with larger $∆P_{PC-MC}$ associated with longer duration; and (ii) the turbulent combustion regime in the main chamber transitioned from the broken reaction zone to the corrugated flamelet regime, with the Karlovitz number exceeding 100 immediately after turbulent hot jets were ejected from nozzles, coinciding with observed local extinction events. To accurately simulate the entire combustion process, a hybrid approach was developed under Reynolds-Averaged Navier Stokes framework, combining the G-equation model for pre-chamber combustion with the multi-zone well-stirred reactor approach and a turbulence-chemistry interaction (TCI) submodel for main chamber combustion. The TCI submodel accounted for the attenuation of reaction rates due to turbulent strain and modeled local extinction by suppressing reaction rates under certain flow and flame conditions. When applied to three EGR rate conditions toward the dilution limit, the hybrid modeling approach accurately reproduced experimental data in terms of cylinder pressure, apparent heat release rate, and the observed positive correlation, including the delayed onset of main chamber combustion—a feature not captured by existing combustion models.

computational fluid dynamics simulation↗

EnergyPlus-MCP: A model-context-protocol server for ai-driven building energy modeling

Traditional building energy modeling with the EnergyPlus building performance simulation engine requires domain expertise, programming skills, and intensive manual efforts limiting its effective adoption. This paper introduces EnergyPlus-MCP, the first open-source Model Context Protocol (MCP) server specifically designed for EnergyPlus simulation workflows, establishing a new foundational infrastructure for AI-driven building energy modeling. The MCP server implements a layered architecture with 35 specialized tools spanning model management, editing and analysis, HVAC and other systems configuration inspection, and simulation execution, enabling Large Language Models to interact with EnergyPlus through conversational interfaces. The server addresses critical workflow barriers by automating model validation, streamlining energy efficiency measures modification, and providing intelligent output management with interactive visualization. Through practical demonstrations using a multi-zone building retrofit analysis, we show how the EnergyPlus-MCP server significantly reduces manual efforts while maintaining full simulation rigor. By providing accessible natural language interfaces to sophisticated building energy analysis, this approach enables scalable deployment of simulation expertise across public and private organizations, educational institutions, and research teams, fundamentally transforming traditional building energy modeling practices.

AI↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insights into the broadband emission of the TeV blazar Mrk 501 during the first X-ray polarization measurements

Aims.We present the first multiwavelength study of Mrk 501 that contains simultaneous very-high-energy (VHE)γ-ray observations and X-ray polarization measurements from the Imaging X-ray Polarimetry Explorer (IXPE). Methods.We used radio-to-VHE data from a multiwavelength campaign carried out between March 1, 2022, and July 19, 2022 (MJD 59639 to MJD 59779). The observations were performed by MAGIC,Fermi-LAT,NuSTAR,Swift(XRT and UVOT), and several other instruments that cover the optical and radio bands to complement the IXPE pointings. We characterized the dynamics of the broadband emission around the X-ray polarization measurements through its multiband fractional variability and correlations, and compared changes observed in the polarization degree to changes seen in the broadband emission using a multi-zone leptonic scenario. Results.During the IXPE pointings, the VHE state is close to the average behavior, with a 0.2–1 TeV flux of 20%–50% of the emission of the Crab Nebula. Additionally, it shows low variability and a hint of correlation between VHEγ-rays and X-rays. Despite the average VHE activity, an extreme X-ray behavior is measured for the first two IXPE pointings, taken in March 2022 (MJD 59646 to 59648 and MJD 59665 to 59667), with a synchrotron peak frequency > 1 keV. For the third IXPE pointing, in July 2022 (MJD 59769 to 59772), the synchrotron peak shifts toward lower energies and the optical/X-ray polarization degrees drop. All three IXPE epochs show an atypically low Compton dominance in theγ-rays. The X-ray polarization is systematically higher than at lower energies, suggesting an energy stratification of the jet. While during the IXPE epochs the polarization angles in the X-ray, optical, and radio bands align well, we find a clear discrepancy in the optical and radio polarization angles in the middle of the campaign. Such results further support the hypothesis of an energy-stratified jet. We modeled broadband spectra taken simultaneous to the IXPE pointings, assuming a compact zone that dominates in the X-rays and the VHE band, and an extended zone stretching farther downstream in the jet that dominates the emission at lower energies.NuSTARdata allow us to precisely constrain the synchrotron peak and therefore the underlying electron distribution. The change between the different states observed in the three IXPE pointings can be explained by a change in the magnetization and/or the emission region size, which directly connects the shift in the synchrotron peak to lower energies with the drop in the polarization degree.

Astronomy & Astrophysics↗

A bi-level data-driven framework for fault-detection and diagnosis of HVAC systems

Long-term operation of heating, ventilation, and air conditioning (HVAC) systems will eventually lead to a range of HVAC system failures, resulting in excessive energy consumption and maintenance costs. Here, to avoid HVAC malfunctioning, fault detection diagnostic (FDD) is utilized as a common practice. Machine learning methods have lately received considerable interest for FDD analysis of HVAC systems due to their high detection accuracy. Meanwhile, HVAC malfunctions are regarded as rare occurrences, hence normal operating data samples are much more accessible than data samples in faulty and malfunctioning conditions. The dominating frequency of normal operation in HVAC datasets has also led to heavily biased classification algorithms within the literature. Moreover, the focus of previous literature has been on increasing the accuracy of the models which leads to a high number of false positives (misleading alarms) in the system. In order to enhance the performance of diagnostic procedures and fill the mentioned gaps, this study proposes a novel data-driven framework. A bi-level machine learning framework is developed for diagnosing faults in air handling units (AHUs) and rooftop units (RTUs) based on principal component analysis (PCA), time series anomaly detection, and random forest (RF). It is shown that PCA can reduce the dataset dimension with one principal component accounting for 95% of data variance. Also, the random forest could classify the faults with 89% precision for single-zone AHU, 85% precision for RTU, and 79% for multi-zone AHU. By proposing this framework, three persistent challenges are addressed: (I) minimizing false positives; (II) accounting for data imbalance; and (III) normal condition monitoring of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗