Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRAL PARTICLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Studying fast-ion populations using oscillations in solid-state neutral-particle analyzer signal and neutral-beam injection power

A method for determining the fast-ion population density in magnetically confined plasmas as a function of pitch-radius, (λ, R), using a solid-state neutral-particle analyzer (ssNPA) signal and neutral-beam injection (NBI) power-output data has been developed. Oscillations in the NBI power output are replicated only in the active part of the ssNPA signal, allowing this to be separated from the passive and background signals, which usually complicate data from this diagnostic. Results obtained using this method are compared with those from standard techniques using data from the Mega-Amp Spherical Tokamak Upgrade spherical tokamak.

Instruments & Instrumentation↗

Modelling the Alfvén eigenmode induced fast-ion flow measured by an imaging neutral particle analyzer

An imaging neutral particle analyzer (INPA) provides energy and radially resolved measurements of the confined fast-ion population ranging from the high-field side to the edge on the midplane of the DIII-D tokamak. In recent experiments, it was used to diagnose fast-ion flow in the INPA-interrogated phase-space driven by multiple, marginally unstable Alfvén eigenmodes (AEs). Here, the key features of this measured fast-ion flow are: (I) a fast-ion flow from q min and the injection energy (81 keV) towards lower energies and plasma periphery.(II) A flow from the same location towards higher energies and the plasma core, (III) a phase-space 'hole' at the injected energy and plasma core and (IV) a pile-up at the plasma core at lower energies (~60 keV). Ad hoc energetic particle diffusivity modelling of TRANSP significantly deviates from the observation. Comparably, a reduced modelling, i.e. a combination of NOVA-K and ASCOT5 code with the measured mode structure and amplitude, generally reproduce some key features of the observed phase-space flow, but largely failed to interpret fast ion depletion near the plasma axis. At last, self-consistent, first-principle multi-phase hybrid simulations that include realistic neutral beam injection and collisions are able to reproduce most features of the time-resolved phase-space flow. During consecutive hybrid phases, an RSAE consistent with the experiment grows and saturates, redistributing the injected fast ions. The resulting synthetic INPA images are in good agreement with the measurement near the injection energy. The simulations track the fast-ion redistribution within the INPA range, confirming that the measured fast-ion flow follows streamlines defined by the intersection of phase-space surfaces of constant magnetic moment μ and constant E' = nE + ωP φ , where n and ω are the instability toroidal mode number and frequency, and E and P φ the ion energy and toroidal canonical momentum. Nonperturbative effects are required to reproduce the depletion of fast ions near the magnetic axis at the injection energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Installation of a solid state neutral particle analyzer array on mega ampere spherical tokamak upgrade

A compact solid state neutral particle analyzer (SSNPA) diagnostic, previously installed at NSTX-U, has been moved to MAST-U and successfully operated in the first physics campaign (MU01). The SSNPA operates by detecting the flux of fast neutral particles produced by charge exchange (CX) reactions to diagnose the fast ion distribution. The diagnostic consists of three 16-channel sensors, which provide a radial view of the plasma and have a sightline intersection with the South–South neutral beam line. From this radial geometry, active CX signals from mostly trapped particles are observed. Each channel has a spatial resolution of 3–4 cm, a temporal resolution of 200 kHz, and an average pitch angle resolution of a few degrees. The three-sensor configuration allows for coarse energy resolution of the CX signals; each sensor sees similar sightlines but different filter thicknesses alter the energy cutoffs by known amounts. Experimental data show that all channels are collecting data as intended. The signal to noise ratio is typically around 15. Preliminary data analysis shows a correlation between the SSNPA signal and magnetohydrodynamic activity in the plasma as expected.

Instruments & Instrumentation↗

Artificial intelligence-based predictive modeling for imaging neutral particle analyzers on the DIII-D tokamak

The Imaging Neutral Particle Analyzer (INPA) at DIII-D is a diagnostic system used to accurately resolve the energy and spatial distributions of fast ions in fusion plasmas. A novel artificial intelligence (AI) technique named INPA-net is based on Reservoir Computing Networks and developed here to predict active and passive signals produced by charge-exchange reactions from injected and edge-cold neutrals, respectively, in magnetically confined fusion plasmas. This model is trained using a set of 21 time domain signals between 0 s to 3.35 s that includes injected beam and thermal plasma information, and 6444 real 2D experimental images of the INPA in 12 plasma discharges at DIII-D. The trained neural network is able to forecast experimental images in real-time. The model achieves an R-squared value of 0.91, which is higher than the 0.83 value achieved by a simple linear regression model. This improvement highlights the model's enhanced predictive accuracy for measured images from the validation set. This AI approach is valuable due to its rapid response times and potential for integration into real-time plasma control systems. A version of this model capable of generating syntehic images would be useful for the real-time monitoring of fast-ion transport. A comprehensive sensitivity study reveals that INPA-net maintains high performance even with variations in the input parameters, indicating the model's robustness and reliability. While developed for the INPA, the underlying architecture is adaptable and may be applied to various 2D imaging diagnostics in fusion research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resolving the fast ion distribution from imaging neutral particle analyzer measurements

A recently developed imaging neutral particle analyzer (INPA) on the DIII-D tokamak (Du 2018 Nucl. Fusion 58 082006) enables fast ion velocity-space tomography of high fidelity at the interrogated phase space. To accomplish this, the spatial and energy depending fast ( E < 80 keV) neutral flux towards the INPA stripping foils is calculated with FIDASIM and a newly developed code INPASIM simulates the INPA instrumental response to this neutral flux. Included in INPASIM is the neutral-foil interaction, the Larmor orbit tracing between the foil and the phosphor, the phosphor response to the incident ion flux as well as camera focusing. Benefiting from heavy, localized velocity-space weights and excellent signal to noise, computed tomography using the Ridge regression method is able to successfully reconstruct fine-scale velocity-space structures produced by multiple neutral beams separated by as small as ~3 keV in tests. Applying the inversion method to a sawtooth crash event reveals a significant profile flattening of confined passing particles across q = 1 flux surface, as well as a redistribution of fast ions into the trapped orbits at the plasma edge close to the last closed flux surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visualization of phase-space orbit topological boundary using imaging neutral particle analyzer

A newly-developed imaging neutral particle analyzer (INPA) in the DIII-D tokamak interrogates phase space occupied by fast ions on multiple different orbit topologies, including passing, stagnation, trapped and potato orbits. Depending on plasma parameters and beam injection geometries, this new INPA system is capable of visualizing distributions of fast ions on the selected orbit topology and its associated orbit topology boundaries. More importantly, the system is able to directly visualize the pitch angle scattering process in phase space by measuring fast ions that are scattered across the trapped-passing orbit topology boundaries. It also enables visualization of fast ion confined-loss boundaries, which are determined by particle energy, plasma current and magnetic field.The key goal of this new INPA system is to directly measure pitch angle scattering across phase space induced by drift waves and its interaction with Alfv'en eigenmodes, i.e., a key issue towards \redit{a} future fusion power plant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in modelling fast-ion D-alpha spectra and neutral particle analyzer fluxes using FIDASIM

FIDASIM is a code that models signals produced by charge-exchange reactions between neutrals and ions (both fast and thermal) in magnetically confined plasmas. With the ion distribution function as input, the code predicts the efflux to a neutral particle analyzer diagnostic and the photon radiance of Balmer-alpha light to a fast-ion D α diagnostic, in addition to many other related quantities. A new, parallelized version of the Monte Carlo code FIDASIM has been developed in Fortran90 that is substantially faster than the original interactive data language version. Modified algorithms include more accurate treatments of the time dependent collisional-radiative equations that describe neutral energy levels, of the cloud of ‘halo’ neutrals that surround the injected neutral beam, and of finite Larmor radius effects. Enhanced physics capabilities include modelling ‘passive’ signals from cold edge neutrals, the ability to treat general three-dimensional magnetic confinement configurations, and calculations of diagnostic-specific weight functions that enable tomographic reconstructions of the fast-ion distribution function. Neutral beam attenuation, beam emission, and fast-ion birth profiles are also modelled. Finally, the new algorithms have been successfully validated against experimental data and new features have been tested through benchmarks between two independently developed versions of the code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intrinsic rotation modulation by diffusive neutral particles in tokamaks

Abstract The modulated transport model, a model kinetic ion transport equation for the pedestal and scrape-off layer (SOL), is generalized to self-consistently include effects of a single neutral particle species. The neutrals contribute additional transport terms, modifying the v ∥ -dependent orbit-averaged ion diffusivities of the original work and the resulting predicted intrinsic rotation of the ions. After making simplifying assumptions of the neutral transport, in particular taking the continuous transport limit via a short charge-exchange step expansion, we derive relatively simple analytic expressions that capture the diffusive neutral physics. Within the scope of the model’s validity, the neutral-driven intrinsic rotation can compete with the turbulence-driven intrinsic rotation. However, for physically motivated parameters, the neutral-driven intrinsic rotation appears negligible, either on a term-by-term basis or due to a strong cancellation between the neutral-driven momentum diffusion and pinch terms. It appears that a treatment containing finite charge-exchange steps is necessary to capture neutral transport of strong flow momentum into the confined region from the SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First fluctuation measurements using an Imaging Neutral Particle Analyzer on DIII-D

A recent upgrade to the Imaging Neutral Particle Analyzer (INPA) on DIII-D has allowed for the first fluctuation measurements using an INPA to be taken during a neoclassical tearing mode (NTM). The INPA signal tracked the mode over 150 ms as the mode frequency dropped to zero, capturing both the NTM with poloidal and toroidal mode numbers $m/n=2/1$ and a $3/2$ mode at double the frequency. Analysis shows that the signals originate from charge exchange events near the edge of the plasma, and relative fluctuation amplitudes are greater than 25% for the duration of the NTM. Filtered signals show frequency beating patterns that are phase-space dependent. Simulated signal is dominated by prompt transport from the neutral beams to the INPA sightline, while the contribution from the slowing down distribution is significantly lower. Simulated measurements in the range of pitches that the diagnostic is sensitive to (0.5≤|v∥/v|≤ 0.75) show the signal is dominated by trapped orbits that pass through magnetic islands near the edge of the plasma. Calculations of expected fluctuation levels show that only direct interaction with the NTM can provide the strong relative fluctuation levels seen experimentally. The prompt nature of the orbits and thin radial layer found to contribute to synthetic signals suggest INPA passive data may be used to measure the perturbations of confined orbits on a single pass through a plasma instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine Learning Approach to Modeling of Neutral Particles Transport in Plasma

A propagator‐based approach is investigated for Monte‐Carlo (MC) modeling of neutral particle transport in fusion boundary plasmas. The propagator is based on a Green's function for the neutral kinetic equation, which depends on the plasma profiles. A neural network (NN)‐based model for the propagator provides a fast and accurate solution for the neutral distribution function in plasma. Preliminary results from a small 1D test problem look encouraging. The proposed approach, a propagator‐based NN model for neutral transport in plasma, has potential for generalization to higher dimensions and efficient coupling with plasma models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of the imaging neutral particle analyzer in nearly MHD quiescent plasmas using injected beam ions on DIII-D

The imaging neutral particle analyzer (INPA) is a scintillator-based diagnostic that provides energy and radially resolved measurements of confined fast ions. To verify operation, understanding, and modeling of the diagnostic performance, distributions of deuterium beam ions in low density, nearly MHD-quiescent plasmas are measured on the DIII-D tokamak using the INPA. Here, the distribution is altered by changing the pitch-angle scattering rate with electron cyclotron heating (ECH). Experimental images are mostly reproduced with simulation of core fast ions charge exchanging with injected beam and edge cold neutrals in classical cases. Image comparisons between the experiment and simulation show agreement with less than 25% discrepancies near the beam injection energy of 50 keV. Other strong passive signals, observed in a localized region on the image, are suggested to come from charge exchange between cold neutrals and fast ions around the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrade and characterization of the fast-channels of Imaging Neutral Particle Analyzers in the DIII-D tokamak

This publication presents the characterization of the recently upgraded fast (MHz) channels of the DIII-D Imaging Neutral Particle Analyzers. The new system allows for a phase space resolution of < 10 keV and < 10 cm. The main source of noise is due to the background radiation (neutrons and gammas) present in the diagnostic lab during experiments, which can hit the photomultipliers and generate large spikes in signal. Good linear correlations (r 2 > 0.9) are found between the average rate of noise spikes in the fast channels and the average neutron rate. Additional noise is caused by the scintillation of the optical fibers used to guide the signal to the acquisition system, which is induced by neutron and gamma impacts. A correlation factor r 2 > 0.6 between the baseline noise caused by this scintillation and the signals in the neutron diagnostic was found. Possible mitigation strategies, such as the use of shielding and filters, are discussed. These allow to reduce the noise spike rate by an order of magnitude and the noise baseline by a factor 4. Despite the noise, it is shown that the upgraded fast channels provide enough signal-to-noise ratio to observe coherent fluctuations of the energetic particle population.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for light long-lived neutral particles that decay to collimated pairs of leptons or light hadrons in $pp$ collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for light long-lived neutral particles with masses in the O(MeV–GeV) range is presented. The analysis targets the production of long-lived dark photons in the decay of a Higgs boson produced via gluon–gluon fusion or in association with a W boson. Events that contain displaced collimated Standard Model fermions reconstructed in the calorimeter or muon spectrometer are selected in 139 fb -1 of $\sqrt{s}$ = 13 TeV $pp$ collision data collected by the ATLAS detector at the LHC. Background estimates for contributions from Standard Model processes and instrumental effects are extracted from data. The observed event yields are consistent with the expected background. Exclusion limits are reported on the production cross-section times branching fraction as a function of the mean proper decay length cτ of the dark photon, or as a function of the dark-photon mass and kinetic mixing parameter that quantifies the coupling between the Standard Model and potential hidden (dark) sectors. A Higgs boson branching fraction above 1% is excluded at 95% CL for a Higgs boson decaying into two dark photons for dark-photon mean proper decay lengths between 10 mm and 250 mm and dark photons with masses between 0.4 GeV and 2 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab

This report discusses the quality and performance of currently available PbWO crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron–Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO 4 production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for light neutral particles decaying promptly into collimated pairs of electrons or muons in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for a dark photon, a new light neutral particle, which decays promptly into collimated pairs of electrons or muons is presented. The search targets dark photons resulting from the exotic decay of the Standard Model Higgs boson, assuming its production via the dominant gluon-gluon fusion mode. The analysis is based on 140 fb -1 of data collected with the ATLAS detector at the Large Hadron Collider from proton-proton collisions at a center-of-mass energy of 13 TeV. Events with collimated pairs of electrons or muons are analysed and background contributions are estimated using data-driven techniques. No significant excess in the data above the Standard Model background is observed. Upper limits are set at 95% confidence level on the branching ratio of the Higgs boson decay into dark photons between 0.001% and 5%, depending on the assumed dark photon mass and signal model.

Aad, G. [Aix-Marseille Université] (ORCID:00000002↗