Search NASASearch

SEARCH · Search NASA

Results for “NIR spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Near-Real-Time Material Tracking: Combining Vis–NIR Spectroscopy with Flow Sensing for Accurate Nd(III) Quantification

A fiber-optic visible–near-infrared (vis–NIR) absorption spectroscopy and flow sensor system has been developed for near-real-time tracking of Nd mass in the effluent stream from a column in a fume hood. The approach leverages two unique data streams and a partial least-squares regression (PLSR) model trained on vis–NIR absorption spectra of Nd(III) (0–1.5 M) in 1 M HNO 3 . In-line volumetric flow rate and vis–NIR spectra are measured in sequence after a chromatography column. The time stamps from each data stream are then synchronized, which allows integrated volumes to be combined with Nd(III) molarities predicted by a PLSR model to accurately calculate the Nd mass flowing through the column. This integrated measurement provides instantaneous mass flow and accumulates these data over time to obtain the total mass processed. The methodology developed in this study contributes critical technical infrastructure to improve monitoring capabilities to support chemical separations and the production of strategic materials and isotopes.

Irvine, Sawyer B. [Oak Ridge National Laboratory (

Measuring and distinguishing compositional and maturity properties of lunar soils by remote VIS-NIR spectroscopy

Space weathering on the lunar surface affects the spectra/optical character of an exposed lunar soil in three ways: the reflectance is reduced, absorption band depths are reduced, and a red-sloped continuum is created and increased with exposure. As a result, the spectrum of a lunar soil is dependent upon both the degree of exposure at the lunar surface and the original composition. It is critical to the remote analysis of lunar soils to differentiate between the optical effects of maturity and the effects of composition. In the laboratory, it is possible to determine and consequently distinguish the degree of exposure, or soil maturity, as measured by parameters such as I(sub s)/FeO (e.g., 1; mature defined as I(sub s)/FeO greater than or equal to 60), and the composition, as measured by various chemical and petrographical techniques. Lunar soils returned by the Apollo missions provide important ground truth for developing methods for remotely measuring the maturity and the concentration of Fe-bearing minerals in lunar soil. The ground truth spectral data analyzed are from the John Adams lunar soil spectra collection. Soils collected from or near highland terrains are emphasized in the discussion. The mineralogical makeup of mare soils results in behavior somewhat different from highland soils.

Fischer, Erich M.

UV–Vis–NIR Reflectance Spectroscopy and Chemometrics for Monitoring Pu Directly on an Ion Exchange Column

Here, we present a fiber-optic UV–vis–NIR reflectance spectroscopy method for direct, noninvasive monitoring of Pu(IV) in a glass ion exchange column during dynamic loading and elution in a glovebox. A movable probe enables spatially resolved spectral acquisition along the column axis, capturing distinct features associated with Pu(IV) nitrate complexes during loading and free ions during elution. Principal component analysis was applied to extract the dominant spectral variance and resolve relative concentration profiles without requiring precise knowledge of optical penetration depth or species identity. This in situ approach reveals spatial gradients and speciation dynamics in real time, which provides actionable insight into Pu(IV) ion migration, resin saturation, and breakthrough behavior under evolving flow conditions. The method offers a practical, fiber-compatible strategy to monitor glass column–based separations for Pu and other lanthanides or actinides and to characterize metal–resin interactions in flow-through systems.

actinide

Near-infrared spectroscopy as a green analytical tool for sustainable biomass characterization for biofuels and bioproducts: An overview

Biomass, a widely used renewable energy source, requires characterization to optimize biofuel and bioproduct processes, customize feedstocks, and ensure economic and environmental sustainability. Conventional wet-chemistry methods for biomass analysis are slow, expensive, and require significant reagents and skilled personnel. In contrast, near-infrared (NIR) spectroscopy, a faster, cost-effective, and reagent-free green technology, enables non-destructive biomass analysis with minimal sample preparation. This study provides an overview of the fundamentals of NIR spectroscopy and explores its recent applications for analyzing various biomass properties important to the biofuel and bioproduct industry. The study also critically evaluates the challenges and opportunities of using NIR spectroscopy for biomass analysis. This review aims to guide future research for rapid and high throughput characterization of biomass in the biomass industry, supporting the United Nations’ sustainable development goal (SDG) 7: producing affordable and sustainable energy.

Biofuels

Near-Infrared (NIR) Raman Spectroscopy of Precambrian Carbonate Stromatolites with Post-Depositional Organic Inclusions

Raman spectroscopy has promising potential for future Mars missions as a non-contact detection technique for characterizing organic material and mineralogy. Such a capability will be useful for selecting samples for detailed analysis on a rover and for selecting samples for return to Earth. Stromatolites are important evidence for the earliest life on Earth and are promising targets for Mars investigations. Although constructed by microorganisms, stromatolites are organo-sedimentary structures that can be large enough to be discovered and investigated by a Mars rover. In this paper, we report the Raman spectroscopic investigations of the carbonate mineralogy and organic layering in a Precambrian (;1.5 Gyr old) stromatolite from the Crystal Spring Formation of Southern California. Ultraviolet (UV: 266 nm), visible (514 nm, 633 nm), and near-infrared (NIR: 785 nm, 1064 nm) Raman spectra are presented. We conclude that 1064 nm excitation is the optimal excitation wavelength for avoiding intrinsic fluorescence and detecting organic carbon within the carbonate matrix. Our results confirm that NIR Raman spectroscopy has important applications for future Mars missions.

Tanaka, Zuki

Noninvasive Intracranial Pressure and Tissue Oxygen Measurements for Space and Earth

The paper discusses the following: Increasing intracranial pressure in humans during simulated microgravity. and near-infrared monitoring of model chronic compartment syndrome in exercising skeletal muscle. Compared to upright-seated posture, 0 deg. supine, 6 deg. HDT, and 15 deg. HDT produced TMD changes of 317 +/- 112, 403 +/- 114, and 474 +/- 112 n1 (means +/- S.E.), respectively. Furthermore, postural transitions from 0 deg. supine to 6 deg. HDT and from 6 deg. to 15 deg. HDT generated significant TMD changes (p less than 0.05). There was no hysteresis when postural transitions to HDT were compared to reciprocal transitions toward upright seated posture. Currently, diagnosis of chronic compartment syndrome (CCS) depends on measurement of intramuscular pressure by invasive catheterization. We hypothesized that this syndrome can be detected noninvasively by near-infrared (NIR) spectroscopy, which tracks variations in muscle hemoglobin/myoglobin oxygen saturation. CCS was simulated in the tibialis anterior muscle of 7 male and 3 female subjects by gradual inflation of a cuff placed around the leg to 40 mmHg during 14 minutes of cyclic isokinetic dorsiflexion exercise. On a separate day, subjects underwent the identical exercise protocol with no external compression. In both cases, tissue oxygenation (T(sub O2) was measured in the tibialis anterior by NIR spectroscopy and normalized to a percentage scale between baseline and a T(sub O2) nadir reached during exercise to ischemic exhaustion. Over the course of exercise, T(sub O2) declined at a rate of 1.4 +/- 0.3% per minute with model CCS, yet did not decrease during control exercise. Post-exercise recovery of T(sub O2) was slower with model CCS (2.5 +/- 0.6 min) than in control (1.3 +/- 0.2 min). These results demonstrate that NIR spectroscopy can detect muscle deoxygenation caused by pathologically elevated intramuscular pressure in exercising skeletal muscle. Consequently, this technique shows promise as a noninvasive diagnostic tool for CCS.

Hargens, A. R.

NIR Imaging Spectroscopy of the Inner Few Arcseconds of NGC 4151 with OSIRIS at Keck

We present H- and K-band data from the inner arcsecond of the Seyfert 1.5 galaxy NGC 4151 obtained with the adaptive optics assisted near-infrared imaging field spectrograph OSIRIS at the Keck Observatory. The angular resolution is about a few parsecs on-site and thus competes easily with optical images taken previously with the Hubble Space Telescope. We present the morphology and dynamics of most species detected but focus on the morphology and dynamics of the narrow line region (as traced by emission of [FeII]λ1.644 μm), the interplay between plasma ejected from the nucleus (as traced by 21 cm continuum radio data) and hot H2 gas and characterize the detected nuclear HeIλ2.058 μm absorption feature as a narrow absorption line (NAL) phenomenon. Emission from the narrow line region (NLR) as traced by [FeII] reveals a biconical morphology and we compare the measured dynamics in the [FeII] emission line with models proposing acceleration of gas in the NLR and simple ejection of gas into the NLR. In the inner 2.5 arcseconds the acceleration model reveals a better fit to our data than the ejection model.We also see evidence that the jet very locally enhances emission in [FeII] at certain positions in our field-of-view such that we were able to distinct the kinematics of these clouds from clouds generally accelerated in the NLR. Further, the radio jet is aligned with the bicone surface rather than the bicone axis such that we assume that the jet is not the dominant mechanism responsible for driving the kinematics of clouds in the NLR. The hot H2 gas is thermal with a temperature of about 1700 K. We observe a remarkable correlation between individual H2 clouds at systemic velocity with the 21 cm continuum radio jet. We propose that the radio jet is at least partially embedded in the galactic disk of NGC 4151 such that deviations from a linear radio structure are invoked by interactions of jet plasma with H2 clouds that are moving into the path of the jet because of rotation of the galactic disk of NGC 4151. Additionally, we observe a correlation of the jet as traced by the radio data, with gas as traced in Brγ and H2, at velocities between systemic and +/- 200 km/s at several locations along the path of the jet. The HeIλ2.058 μm line in NGC 4151 appears in emission with a blueshifted absorption component from an outflow. The emission (absorption) component has a velocity offset of 10 km/s (-280 km/s) with a Gaussian (Lorentzian) full-width (half-width) at half maximum of 160 km/s (440 km/s). The absorption component remains spatially unresolved and its kinematic measures differ from that of UV resonance absorption lines. From the amount of absorption we derive a lower limit of the HeI 2S column density of 1 × 10(exp 14) cm−2 with a covering factor along the line-of-sight of C(sub los) approximately equal to 0.1.

K-band data

NIRS in Space?

Proponents of near infrared reflectance spectroscopy (NIRS) have been exceptionally successful in applying NIRS techniques to many instances of organic material analyses. While this research and development began in the 1950s, in recent years, stimulation of advancements in instrumentation is allowing NIRS to begin to find its way into the food processing systems, into food quality and safety, textiles and much more. And, imaging high spectral resolution spectrometers are now being evaluated for the rapid scanning of foodstuffs, such as the inspection of whole chicken carcasses for fecal contamination. The imaging methods are also finding their way into medical applications, such as the non-intrusive monitoring of blood oxygenation in newborns. Can these scientific insights also be taken into space and successfully used to measure the Earth's condition? Is there an analog between the organic analyses in the laboratory and clinical settings and the study of Earth's living biosphere? How are the methods comparable and how do they differ?

Peterson, David L.

A quantitative comparison of simultaneous BOLD fMRI and NIRS recordings during functional brain activation

Near-infrared spectroscopy (NIRS) has been used to noninvasively monitor adult human brain function in a wide variety of tasks. While rough spatial correspondences with maps generated from functional magnetic resonance imaging (fMRI) have been found in such experiments, the amplitude correspondences between the two recording modalities have not been fully characterized. To do so, we simultaneously acquired NIRS and blood-oxygenation level-dependent (BOLD) fMRI data and compared Delta(1/BOLD) (approximately R(2)(*)) to changes in oxyhemoglobin, deoxyhemoglobin, and total hemoglobin concentrations derived from the NIRS data from subjects performing a simple motor task. We expected the correlation with deoxyhemoglobin to be strongest, due to the causal relation between changes in deoxyhemoglobin concentrations and BOLD signal. Instead we found highly variable correlations, suggesting the need to account for individual subject differences in our NIRS calculations. We argue that the variability resulted from systematic errors associated with each of the signals, including: (1) partial volume errors due to focal concentration changes, (2) wavelength dependence of this partial volume effect, (3) tissue model errors, and (4) possible spatial incongruence between oxy- and deoxyhemoglobin concentration changes. After such effects were accounted for, strong correlations were found between fMRI changes and all optical measures, with oxyhemoglobin providing the strongest correlation. Importantly, this finding held even when including scalp, skull, and inactive brain tissue in the average BOLD signal. This may reflect, at least in part, the superior contrast-to-noise ratio for oxyhemoglobin relative to deoxyhemoglobin (from optical measurements), rather than physiology related to BOLD signal interpretation.

Non-NASA Center

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS

Multi-site Milling Strategy Reveals Significant Variation in Biomass Composition of Switchgrass ( Panicum virgatum ) Grown at Ten Locations

Cell wall composition influences biomass use as a forage and as a feedstock for biofuel and chemical conversion. To examine the influence of environment on composition of switchgrass (Panicum virgatum L.), we utilized a multi-environment experiment consisting of clones of switchgrass genotypes grown at up to ten locations in the continental US. We tested the influence of different milling treatments on biomass composition trait predictions via near-infrared reflectance spectroscopy (NIRS). We found that most compositional trait predictions (29/34) were significantly different (P < 0.05) when a single lot of biomass was subjected to disparate milling treatments, i.e., knife milling vs. knife milling with an additional cyclone milling. Further, depending on the plant material tested, three to eight compositional trait predictions vary (P < 0.05) when identical biomass was knife milled at different sites followed by cyclone milling at a single site, including for traits such as Klason lignin, nitrogen, and carbon. In some cases, variation due to milling site exceeded environmentally induced compositional variation of a single switchgrass genotype grown at different sites. From these observations, we recommend a protocol with two sequential millings that decouples growth environment from a particular mill. Utilizing this approach, we found that 46/46 biomass composition traits from the warm season herbaceous forage and switchgrass bioethanol NIRS equations vary significantly (P < 0.001) in clones of a switchgrass genotype (WBC) grown at ten sites, with the growth site representing the largest average source of variation (41%). This multi-site milling approach can be used to examine environmental and gene-by-environment influences on composition with the goal of optimizing cell wall composition in different environments for biomass utilization.

09 BIOMASS FUELS

Validation of a New NIRS Method for Measuring Muscle Oxygenation During Rhythmic Handgrip Exercise

Near infrared spectroscopy (NIRS) is commonly used to measure muscle oxygenation during exercise and recovery. Current NIRS algorithms do not account for variation in water content and optical pathlength during exercise. The current effort attempts to validate a newly developed NIRS algorithm during rhythmic handgrip exercise and recovery. Six female subjects, aver age 28 +/- 6 yrs, participated in the study. A venous catheter was placed in the retrograde direction in the antecubital space. A NIRS sensor with 30 mm source-detector separation was placed on the flexor digitorum profundus. Subjects performed two 5-min bouts of rhythmic handgrip exercise (2 s contraction/1 s relaxation) at 15% and 30% of maximal voluntary contraction. Venous blood was sampled before each bout, during the last minute of exercise, and after 5 minutes of recovery. Venous oxygen saturation (SvO2) was measured with a I-stat CG-4+ cartridge. Spectra were collected between 700-900 nm. A modified Beer's Law formula was used to calculate the absolute concentration of oxyhemoglobin (HbO2), deoxyhemoglobin (Hb) and water, as well as effective pathlength for each spectrum. Muscle oxygen saturation (SmO2) was calculated from the HbO2 and Hb results. The correlation between SvO2 and SmO2 was determined. Optical pathlength and water varied significantly during each exercise bout, with pathlength increasing approximately 20% and water increasing about 2%. R2 between blood and muscle SO2 was found to be 0.74, the figure shows the relationship over SvO2 values between 22% and 82%. The NIRS measurement was, on average, 6% lower than the blood measurement. It was concluded that pathlength changes during exercise because muscle contraction causes variation in optical scattering. Water concentration also changes, but only slightly. A new NIRS algorithm which accounts for exercise-induced variation in water and pathlength provided an accurate assessment of muscle oxygen saturation before, during and after exercise.

Hagan, R. Donald

Pressure-Induced Stabilization of Terbium(IV) in CsTb(CrO 4 ) 2 Characterized by X-ray Absorption Spectroscopy

Single crystals of CsTb(CrO 4 ) 2 and CsDy(CrO 4 ) 2 , where the lanthanide metals are in the trivalent state under ambient conditions, have been investigated under high-pressure conditions on the gigapascal scale utilizing a diamond anvil cell. These compounds were characterized by single-crystal X-ray diffraction in addition to high-pressure solid-state UV-vis-NIR spectroscopy, Raman spectroscopy, and Tb L 3 -edge highenergy- resolution fluorescence-detected X-ray absorption near-edge structure (HERFD-XANES). The high-pressure UV-vis-NIR spectra reveal strong broadening of the metal-to-ligand charge transfer band to lower energies, associated with a visible color change from yellow to dark red/black. Clear evidence for the stabilization of Tb 4+ under high pressure is provided by the appearance of a second edge feature characteristic of Tb 4+ , starting at 19.62 GPa in the high-pressure L 3 -edge HERFD-XANES at around 7528 eV. This represents the first example of Tb 4+ being stabilized by high pressure and expands upon the limited chemistry of terbium in the tetravalent state.

Anions

Influence of particle size on NIR spectroscopic characterization of sorghum biomass for the biofuel industry

NIR spectroscopy is a rapid and accurate green technology for high-throughput biomass characterization, including sorghum (Sorghum bicolor), a promising energy crop for the biofuel industry. This study assessed the influence of particle size on NIR spectroscopic analysis (wavelength range: 867–2535 nm) of sorghum biomass composition. Grown under field conditions, a total of 113 types of genetically diverse sorghum accessions were dried, ground, and sieved (<250, 250–600, 600–850, and > 850 µm particle size) for developing partial least square regression (PLSR) prediction models for moisture, ash, extractive, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin (ASL + AIL). Overall, smaller particle sizes provided better model performance, while no single particle size provided the best performance for all the selected components. With only 9 selected bands and 4 latent variables (LVs), the best PLSR model was obtained for moisture with particle size of 600–850 µm with the square root of the coefficient of determination (R) of 0.85, the ratio of prediction to deviation (RPD) of 2.2, and the root mean square error (RMSE) of 0.46 % in external validation. Similar model performances were also obtained for ash, extractive, glucan, and xylan. This study showed that size reduction could effectively improve NIR spectroscopic analysis for lipid-producing sorghum biomass for the biofuel industry.

09 BIOMASS FUELS

Data for Influence of Particle Size on NIR Spectroscopic Characterization of Sorghum Biomass for the Biofuel Industry

NIR spectroscopy is a rapid and accurate green technology for high-throughput biomass characterization, including sorghum ( Sorghum bicolor ), a promising energy crop for the biofuel industry. This study assessed the influence of particle size on NIR spectroscopic analysis (wavelength range: 867–2535 nm) of sorghum biomass composition. Grown under field conditions, a total of 113 types of genetically diverse sorghum accessions were dried, ground, and sieved (<250, 250–600, 600–850, and > 850 µm particle size) for developing partial least square regression (PLSR) prediction models for moisture, ash, extractive, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin (ASL + AIL). Overall, smaller particle sizes provided better model performance, while no single particle size provided the best performance for all the selected components. With only 9 selected bands and 4 latent variables (LVs), the best PLSR model was obtained for moisture with particle size of 600–850 µm with the square root of the coefficient of determination (R) of 0.85, the ratio of prediction to deviation (RPD) of 2.2, and the root mean square error (RMSE) of 0.46 % in external validation. Similar model performances were also obtained for ash, extractive, glucan, and xylan. This study showed that size reduction could effectively improve NIR spectroscopic analysis for lipid-producing sorghum biomass for the biofuel industry.

Biomass Analytics

Time-to-Fatigue and Intramuscular pH Measured via NIRS During Handgrip Exercise in Trained and Sedentary Individuals

In exercising muscles force production and muscular endurance are impaired by a decrease in intramuscular pH. The effects of aerobic training (AT) on preventing acidosis and prolonging exercise time in muscles not specifically targeted by the training are unknown. Purpose: To compare interstitial pH, measured non-invasively with near infrared spectroscopy (NIRS), in the flexor digitorum profundus (FDP) during rhythmic handgrip exercise in sedentary subjects and those who participate in AT activities that target the lower body. Methods: Maximal isometric force (MIF) was measured on three separate days in AT (n=5) and sedentary (n=8) subjects using a handgrip dynamometer (HGD). Isometric muscular endurance (IME) was measured during five trials, each separated by at least 48 hrs. For each IME trial subjects rhythmically squeezed (4 sec at 40% of MVC) and relaxed (2 sec) to fatigue or failure to reach the target force in three consecutive contractions or four non-consecutive contractions. Interstitial pH was derived from spectra collected using a NIRS sensor adhered to the skin over the FDP. The first four IME trials served to familiarize subjects with the protocol; the fifth trial was used for analysis. NIRS-derived pH was averaged in 30 sec increments. Between group differences in MIF and exercise time were tested using paired t-tests. A repeated measures ANOVA was used to analyze effects of AT and exercise time on pH. Results: MIF was not different between groups (mean SD; aerobic=415.6 95.4 N vs. sedentary =505.1 107.4 N). Time to fatigue was greater in the AT than in the sedentary group (mean SD: 611 173 sec vs. 377 162 sec, p<0.05). pH was not different between groups at any time point. Average pH decreased (p<0.05) in both groups from rest (pH=7.4) through 90 sec of exercise (pH=6.9), but did not decrease further throughout the remainder of exercise. Conclusion: Although between group differences in pH were not detected, differences during the onset of exercise may exist with a more frequent sampling. AT individuals appear to better tolerate decreased interstitial pH and are able to continue submaximal muscular work, possibly due to psychological familiarization to muscular fatigue and/or systemic physiological benefits.

Everett, M. E.

NIRS-Derived Tissue Oxygen Saturation and Hydrogen Ion Concentration Following Bed Rest

Long-term bed rest (BR), a model of spaceflight, results in a decrease in aerobic capacity and altered submaximal exercise responses. The strongest BR-induced effects on exercise appear to be centrally-mediated, but longer BR durations may result in peripheral adaptations (e.g., decreased mitochondrial and capillary density) which are likely to influence exercise responses. PURPOSE: To measure tissue oxygen saturation (SO2) and hydrogen ion concentration ([H+]) in the vastus lateralis (VL) using near infrared spectroscopy (NIRS) during cycle ergometry before and after . 30 d of BR. METHODS: Eight subjects performed a graded exercise test on a cycle ergometer to volitional fatigue 7 d before (pre-BR) and at the end or 1 day after BR (post-BR). NIRS spectra were collected from a sensor adhered to the skin overlying the VL. Oxygen consumption (VO2) was measured by open circuit spirometry. Blood volume (BV) was measured before and after BR using the carbon monoxide rebreathing technique. Changes in pre- and post-BR SO2 and [H+] data were compared using mixed model analyses. BV and peak exercise data were compared using paired t-tests. RESULTS: BV (pre-BR: 4.3+/-0.3, post-BR: 3.7+/-0.2 L, mean+/-SE, p=.01) and peak VO2 (pre-BR: 1.98+/-0.24, post-BR: 1.48 +/-0.21 L/min, p<.01) were reduced after BR. As expected, SO2 decreased with exercise before and after BR. However, SO2 was lower post compared with pre-BR throughout exercise, including at peak exercise (pre-BR: 50+/-3, post-BR: 43+/-4%, p=.01). After BR, [H+] was higher at the start of exercise and did not increase at the same rate as pre-BR. Peak [H+] was not different from pre to post-BR (pre-BR: 36+/-2; post-BR: 38+/-2 nmol/L). CONCLUSIONS: Lower SO2 during exercise suggests that oxygen extraction in the VL is higher after BR, perhaps due to lower circulating blood volume. The higher [H+] after BR suggests a greater reliance upon glycolysis during submaximal exercise, although [H+] at peak exercise was unchanged. Taken together, these data suggest that longer duration BR induces a number of changes that result in peripheral adaptations which contribute to cardiovascular and muscular deconditioning as measured by NIRS-derived SO2 and [H+] in the VL and may contribute to lower post-BR exercise tolerance. Supported by the National Space Biomedical Research Institute through NASA NCC 9-58

Lee, S. M. C.