Search NASA⌕ Search

SEARCH · Search NASA

Results for “NIST Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Real-Time Protocol Engineering with the B Language

It is an invariant that critical cyberphysical systems should not fail. Mission assurance requires systems to behave with predictability, especially in their ability to satisfy real-time constraints. The NIST standard for Engineering Trustworthy Secure Systems, National Institute of Standards and Technology (NIST) Special Publication (SP) 800-160v1r1 states that formal methods are the highest level for meeting assurance requirements. There is a tension between the formal method software development process (Figure 1), which does not introduce time specificity until the latter stages of the development process (concrete model), and the need to gain confidence that time constraints will be satisfied. This paper formalizes the practical application of temporal entities e.g. Propositional Temporal Logic (PTL), Temporal Logic of Actions Plus (TLA+), etc. to critical systems.

97 MATHEMATICS AND COMPUTING↗

Corresponding Standard Reference Material Data used in Partial Least Squares Regression Models for Sugar Composition Estimates in Biomass in: Economic Impact of Yield and Composition Variation in Bioenergy Crops: Populus trichocarpa

Corresponding Standard Reference Material Data used in Partial Least Squares Regression Models for Sugar Composition Estimates in Biomass in: Economic Impact of Yield and Composition Variation in Bioenergy Crops: Populus trichocarpa (for corresponding manuscript: DOI: 10.1002/bbb.2148) PDF Files: Images of 1H NMR spectra for neutralized 2-stage acid hydrolysates of 4 NIST Standard Reference Material biomass samples (Monterey Pine 8493, Sugarcane Bagasse 8491, Wheat Straw 8494, and Eastern Cottonwood/Poplar 8492) and 2 Center for Bioenergy Innovation reference biomass samples (Poplar - Populus trichocarpa and Switchgrass - Panicum Virgatum). Suppression of the water peak was achieved using a NOESY-1D with presaturation, a recycle delay of 5 s, and a total of 64 scans. Spectra were acquired at 298 K and processed with automatic phase correction, baseline correction, and chemical shift referencing to TSP-d4. Images show all 1H data from 10 to 1ppm with inset spectra of region of interest (4.0 to 3.1 ppm). Text Files: Spectra for neutralized 2-stage acid hydrolysates of 4 NIST Standard Reference Material biomass samples (Monterey Pine 8493, Sugarcane Bagasse 8491, Wheat Straw 8494, and Eastern Cottonwood/Poplar 8492) and 2 Center for Bioenergy Innovation reference biomass samples (Poplar - Populus trichocarpa and Switchgrass - Panicum Virgatum) were converted into text files for plotting. Files contain 8192 points of raw spectral data from 12.23 to -2.78 ppm. The text file contains 4 columns of data and includes: Point number, Intensity, Hz, and ppm. Xcel Spreadsheet: HPLC measured monomeric sugar concentrations and bucketed 1H NMR data used to build monomeric sugar composition prediction models. Sugar composition in biomass determined from HPLC analyses are given in mg sugar/mg of biomass. Spectral bucketing was performed using Bruker’s AMIX software. Spectra were divided into 0.005 ppm buckets in the region of 3.10– 4.15 ppm for a total of 210 buckets. Headers for the bucketed data are the chemical shift in ppm of the center of the bucket. Bucketed data was used to build partial least squares models for subsequent predictions in The Unscrambler v. 10.5(CAMO A/S, Trondheim, Norway). The formation of methanol during hydrolysis interferes with the quantitative NMR analysis of sugars, so the methanol peak centered at 3.37 ppm and spanning four buckets (3.2925 – 3.2775 ppm) was set to zero for all spectra.

09 BIOMASS FUELS↗

Reference Materials for Laser and Xenon Flash Thermal Diffusivity Systems

This report presents the status of current standard reference materials for thermal diffusivity testing. In most thermal properties testing systems, it is common to use standard reference materials to show the reproducibility of the tests and certify the instrument is producing results within expected uncertainty range. The definition of reference materials or standards vary depending on the quality control protocols of the project. For thermal diffusivity, although there were standards available by the National Bureau of Standards (NBS) 40 years ago, there has been no recent NIST standard reference material (SRM). There are only a few sources that produce and provide traceable reference standards for thermal diffusivity. The certificate typically expires in 5 years and only applies to the specific lot of materials. Other reference materials are provided by the testing systems manufacturers. They are mostly well-known reference materials or materials used by the equipment manufacturers with historic data. However, most these reference materials no longer carry valid certificates. Various reference materials will be discussed along with the industry practice when only secondary standards are available.

36 MATERIALS SCIENCE↗

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Investigation of Barium Sources and Fluid–Rock Interaction in Unconventional Marcellus Shale Wells Using Ba Isotopes

Produced waters from unconventional Marcellus Shale gas wells have anomalously high barium (Ba) concentrations and yield some of the isotopically heaviest Ba measured to date. Experiments were conducted to constrain the source of Ba in these fluids and the controls on barite (BaSO 4 ) precipitation and dissolution in oil and gas wells. Experiments simulating the acidizing stage evaluated the solubility of pure barite and drilling mud in 2 M HCl at 80 °C for periods of 2, 6, and 48 h and resulted in <0.01% barite dissolution with no appreciable change in δ 138 Ba ( 138 Ba/ 134 Ba normalized to NIST standard 3104a). Static autoclave experiments conducted at 66 °C and 20.7 MPa with combinations of ground Marcellus Shale solids and/or barite-bearing drilling mud with synthetic low-Ba fracturing fluid resulted in decreased Ba concentrations in the fluid, with the largest decrease in the shale-only run. Fluid δ 138 Ba values increased by about 0.5‰ as Ba concentrations decreased, consistent with closed-system Rayleigh fractionation. Flow-through experiments in Marcellus Shale core conducted for 28 days resulted in effluent Ba concentrations an order of magnitude lower than the influent, while sulfate concentrations increased over time. Effluent δ 138 Ba values increased over the first 12 days and plateaued at about 1‰ higher than the influent. Modeling suggests a combination of the release of labile shale Ba and barite precipitation. This work indicates that the processes of Ba release from fluid–shale interactions and barite precipitation in fractures and the well bore, while capable of producing high δ 138 Ba fluids, are unlikely to generate fluids with high-Ba concentrations and δ 138 Ba values like those in Marcellus-produced waters. As a result, we find that the release of sulfate from shale pyrite oxidation rapidly catalyzes barite precipitation and that dissolution of drilling mud barite or natural barite in the shale is unlikely to be the major source of Ba in Marcellus-produced waters.

54 ENVIRONMENTAL SCIENCES↗

Bubble Point Measurements of Three Binary Mixtures of Refrigerants: R-32/1234yf, R-32/1234ze(E), and R-1132a/1234yf

In this article, bubble point pressures of three binary mixtures at two compositions each have been measured utilizing a static method. The mixtures studied were difluoromethane + 2,3,3,3-tetrafluoroprop-1-ene (R-32/1234yf), difluoromethane + (E)-1,3,3,3-tetrafluoroprop-1-ene (R-32/1234ze(E)), and 1,1-difluoroethene + 2,3,3,3-tetrafluoroprop-1-ene (R-1132a/1234yf). For all of the mixtures, the minimum temperature measured was 270 K. The maximum temperatures measured for the R-32/1234ze(E), R-32/1234yf, and R-1132a/1234yf mixtures were 360, 345, and 325 K, respectively. A total of 100 bubble point pressures are reported and compared to available literature data relative to the REFPROP database. Lemmon, E. W. [ NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, 10.0; National Institute of Standards and Technology, Standard Reference Data Program: Gaithersburg, 2018]. Additionally, the bubble point pressures obtained in this study are modeled using the perturbed-chain statistical associating fluid theory (PC-SAFT) equation of state. The PC-SAFT model parameters, as well as deviations of this work and literature data from the model, are reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interlaboratory Study for Characterizing Monoclonal Antibodies by Top-Down and Middle-Down Mass Spectrometry

The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product’s primary structure reliably and reproducibly. The major objective of the present study was to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up approaches, such as confirming protein integrity, sequencing variable domains, ruling out artefacts, and revealing modifications and their locations. A panel of three mAbs was selected and centrally provided to twenty laboratories worldwide for the analysis: Sigma mAb standard (SiLuLite), NIST mAb standard, and the therapeutic mAb Herceptin (trastuzumab). A variety of different MS instrument platforms and ion dissociation techniques were employed. Overall, the present study confirms that MD/TD MS strategies are valuable and readily available tools in laboratories worldwide. They provide complementary information to the bottom-up approach and can add unique information, which may be crucial for comprehensive mAb characterization. The current limitations, as well as possible solutions to overcome them, are also outlined. One of the limitations revealed by the results of the present study is that the expert knowledge in both experiment and data analysis is indispensable to practice TD/MD MS, but the number of TD/MD MS experts is still very low.

59 BASIC BIOLOGICAL SCIENCES↗

Operational Energy Life Cycle Data Development for the National Institute of Standards And Technology (NIST) Building Industry Reporting and Design for Sustainability (BIRDS) Neutral Environmental Software Tool (NEST)

For this analysis, regionalized life cycle assessment (LCA) results for environmental impacts (using the Tool for Reduction and Assessment of Chemicals and Other Environmental Impacts [TRACI] 2.1) and cumulative energy demand (using the Federal Life Cycle Analysis Commons Elementary Flow List [FEDEFL] Inventory Methods v1.0.0) were evaluated for the production and utilization of electricity, natural gas, fuel oil, and propane as commodities within residential and commercial buildings. These results can used as a framework for future research into net zero, high-performance buildings, such as done here for the Building Industry Reporting and Design for Sustainability (BIRDS) database by the National Institute of Standards and Technology (NIST) Engineering Laboratory. The geographical results were assigned to each United States (U.S.) Zone Improvement Plan (ZIP) code based on the ZIP code location and corresponding Balancing Authority Area, natural gas basin, and Petroleum Administration for Defense Districts (PADDs). Additionally, previously developed models were utilized to develop future life cycle profiles. Projections were based on data available from the U.S. Energy Information Administration Annual Energy Outlook 2022 through 2050 (AEO 2022). Electricity LCA models were updated based on AEO 2022 projected annual generation mixes, while the natural gas baseline model was updated based on projected shares of natural gas types (conventional, shale, tight, and coalbed methane). Projections of crude oil production rates and export rates were applied to the petroleum baseline model in five-year increments to investigate their effects on the life cycle profile of fuel oil and propane. While only 100-year Global Warming Potential (GWP-100) with climate carbon feedback (CC-FB) and Cumulative Energy Demand are shown in Section 4: Results, the complete results, including Acidification Potential, Eutrophication Potential, Freshwater Ecotoxicity Potential, GWP-100 without inclusion of CC-FB, Human Health Impacts Potentials (Cancer, Non-Cancer), Ozone Depletion Potential, Particulate Matter Formation Potential, and Photochemical Smog Formation Potential, are tabulated for each ZIP code in the Excel worksheets that accompany this analysis. For the Excel spreadsheet tools associated with this report, please go to https://www.netl.doe.gov/energy-analysis/details?id=f8890fac-be55-44ac-aaa9-e2888bfabe93

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A preliminary investigation into the use of molecular oxide and hydride secondary ion relationships for improvement of the 236U/238U determination on a NanoSIMS 50L

Abstract A NanoSIMS 50L is used to investigate uranium molecular ( 235 U 16 O, 236 U 16 O, 238 U 16 O, 235 U 1 H, 238 U 1 H, 236 U 16 O 1 H, and 238 U 16 O 1 H) and elemental ( 235 U, 236 U, and 238 U) secondary ion production during sputtering of synthetic UO 2 and the NIST-610 standard to determine if: (1) the 236 U 16 O/ 238 U 16 O molecular oxide ratio performs better than the 236 U/ 238 U elemental ratio, and (2) there is co-variance between the molecular hydrides and oxides. Despite an order of magnitude greater abundance of 236 U 16 O secondary ions (compared to 236 U), the 236 U 16 O/ 238 U 16 O ratios are less accurate than the 236 U/ 238 U ratios. Further work is needed before the higher count rate of the 236 U 16 O secondary ion can be used to obtain a better 236 U/ 238 U ratio. The second objective was undertaken because correction for the interference of 235 U 1 H on the 236 U secondary ion species typically utilizes the 238 U 1 H/ 238 U ratio. This becomes problematic in samples containing 239 Pu, so our aim was to understand if the hydride formation rate can be constrained independently of having to measure the 238 U 1 H. We document correlations between the hydride ( 238 U 1 H and 238 U 16 O 1 H) and oxide ( 236 U 16 O) secondary ions, suggesting that pursuing an alternative correction regime is worthwhile.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantification of Residual Water in Spent Fuel Dry Storage Canisters Using Mass Spectrometry

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cyber Labeling for Energy Industrial IoT

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security and Emergency Response (CESER), at the request of the Deputy National Security Advisor for Cyber and Emerging Technologies, Anne Neuberger, initiated research in 2023 to develop a cybersecurity labeling proof-of-concept for energy products to expand on the Federal Communications Commission’s (FCC) proposed U.S. Cyber Trust Mark program. DOE mobilized researchers from six National Laboratories to develop and gather feedback on a proof-of concept label for solar inverters and smart meters, which serve as representative products for market-facing energy sector Industrial Internet of Things (IIoT). This report details the research team’s process across two phases and the resulting findings, which include challenges facing cyber labeling programs and recommendations to implement an expanded IIoT cyber labeling program in the U.S.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

Review of Life Cycle Cost Analysis Tools

Life cycle costing (LCC) is a vital aspect of decision-making in building retrofitting. It allows stakeholders to thoroughly assess all expenses involved throughout the lifespan of these retrofits, covering initial costs; ongoing operation, maintenance, and repair costs; and disposal costs of the system. The Federal Energy Management Program of the US Department of Energy has established clear guidelines for conducting LCC analysis, particularly for investments aimed at energy and water conservation, as well as renewable energy projects. These guidelines are detailed in the Code of Federal Regulations, 10 CFR 436, Subpart A, which outlines the methodology and procedure for LCC analysis (Department of Energy 1990). The National Institute of Standards and Technology (NIST) has developed the NIST Handbook 135 (Joshua Kneifel 2022) to standardize the process of LCC analysis within the building industry. Whereas the handbook is tailored to the needs of federal agencies, its principles and methodologies can be valuable for other organizations and industries interested in conducting life cycle costing analyses for their building projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Neural Network Analysis of Nuclear Magnetic Resonance and Infrared Spectra

Nuclear magnetic resonance (NMR) spectroscopy and infrared (IR) spectroscopy are powerful chemical characterization techniques with broad general usage. However, the manual evaluation of the resulting spectra is time-consuming and requires significant expertise, preventing insights from being used in real-time applications. With recent advances in computation and artificial intelligence (AI), new tools are available for automating spectral interpretation. In this work, machine learning (ML) algorithms using 1-dimensional convolutional neural networks (CNNs) were applied to identify common functional groups from spectral information. Raw spectra were collected virtually from the Human Metabolome Database (HMDB) and National Institute of Standards and Technology (NIST) Chemistry WebBook and processed into a suitable standard. Algorithm design was tailored to best fit the nature of the problem, with built-in flexibility to accommodate relevant parameters beyond the raw spectral input, specifically solvent identity and magnetic frequency for NMR. The predictive capability of the algorithm in identifying functional groups is displayed in several examples. This methodology has been compiled into a code repository and could easily be modified to adapt alternative data sources, including other spectrum types. To mitigate overfitting, a common problem in mathematical modeling where overfamiliarity with training data produces trends that are not representative of the general data, a novel metric was developed, referred to as Accufit. Accufit includes a parameter that penalizes substantial differences in the training accuracy and the accuracy of an independent validation set. Examples are presented showing the effectiveness of Accufit in maintaining the model’s predictive capability while controlling the overfitting when used as a custom metric for hyperparameter tuning.

Sturgill, James↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NIST: Soil Respiration, Moisture, Temperature, Chemistry; and Fine Root Measurements from a Transect Through a Forest Edge, Gaithersburg, Maryland, 2017-2021

This dataset contains soil respiration, moisture, temperature, and chemistry, as well as fine root measurements from the National Institute of Standards and Technology (NIST) Forested Optical Reference for Evaluating Sensor Technology (FOREST) research facility at Gaithersburg, Maryland. Measurements were taken at an existing transect array that begins in a grassy meadow, crosses a sharp forest edge, then a small stream, and finally extends upwards in the interior of the forest at the top of a ridge. There are 6 different landscape positions replicated across three transects in the array. Soil respiration was measured during growing seasons in 2017-2019 (2017-06-02 to 2020-02-27). Pedons (1 m3) were isolated from surrounding tree roots using trenching and a fabric to inhibit root ingrowth. Flux measurements inside the pedons were thus assumed to represent heterotrophic only respiration in 2019, and these fluxes were paired with nearby fluxes assumed to represent total respiration. Deep vertical probes measured volumetric moisture content and temperature at the same points in the array every 10 cm in depth to either 90 cm or 120 cm total depth, at 15 minute intervals, from 2019-2021 (2019-07-09 to 2021-09-10). Soil core samples were collected from each of the array points for three different months in early- to mid-2019 (2019-03-19 to 2019-07-10), at three depths each. Soils were analyzed for gravimetric moisture content; pH; total carbon, nitrogen, and phosphorus; texture; microbial biomass carbon, nitrogen, and phosphorus; extractable dissolved organic carbon, nitrogen, and phosphorus; extractable nitrate and ammonia; and extracellular hydrolytic enzyme activities. The fine roots were separated from the cores and segregated by plant functional type (grass or tree species) and if they were dead or alive. Fine roots were then measured for length, surface area, diameter, and dry mass. This dataset contains four data files in comma separated (*.csv) format. These data serve to deepen our understanding of root and soil processes at forest edges and in transitional zones.

54 ENVIRONMENTAL SCIENCES↗