Search NASA⌕ Search

SEARCH · Search NASA

Results for “NaI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Validation and uncertainty quantification of detector response functions for a $1"×2"$ NaI collimated detector intended for inverse radioisotope source mapping applications

Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The quick and ultrasensitive determination of K in NaI using inductively coupled plasma mass spectrometry

A highly sensitive, novel and quick assay method utilizing inductively coupled plasma mass spectrometry was developed for the determination of K in NaI powders and NaI(Tl) scintillator crystals for use in ultralow background applications. The determination of K (viz. 40K), as well as Th and U and their daughters, is important in ultralow background detector materials to ensure incorporation of materials of sufficiently high radiopurity. Through the use of improved instrumentation, cool plasma operating conditions, and meticulously clean sample preparations, detection limits of 11 fg natK∙g-1 (or 341 pBq 40K∙kg-1) was attained for K in pure water. Detection limits in the sample matrix (i.e., NaI) were 0.529 ng natK∙g NaI-1 (or 16.4 Bq 40K∙kg NaI -1). A number of different precursor NaI powder samples and NaI(Tl) scintillator crystals were assayed for their K content. Determinations ranged from 0.757 – 31.4 ng natK∙g NaI-1. This method allows for the screening of materials to unprecedented levels in a fraction of the time compared to gamma counting techniques, providing a useful method for a more effective screening tool of K in ultralow background detector materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrochemistry of the NaI-AlBr 3 Molten Salt System: A Redox-Active, Low-Temperature Molten Salt Electrolyte

NaI-AlBr 3 is a very appealing low melting temperature (<100 °C), salt system for use as an electrochemically-active electrolyte. This system was investigated for its electrochemical and physical properties with focus to energy storage considerations. A simple phase diagram was generated; at >100 °C, lower NaI concentrations had two partially miscible liquid phases, while higher NaI concentrations had solid particles. Considering the fully molten regime, electrical conductivities were evaluated over 5–25 mol% NaI and 110 °C–140 °C. Conductivities of 6.8–38.9 mS cm −1 were observed, increasing with temperature and NaI concentration. Effective diffusion coefficients of the I − /I 3 − redox species were found to decrease with both increasing NaI concentration and increasing applied potential. Regardless, oxidation current density at 3.6 V vs Na/Na + was observed to increase with increasing NaI concentration over 5–25 mol%. Finally, the critical interface between the molten salt electrolyte and electrode materials was found to significantly affect reaction kinetics. When carbon was used instead of tungsten, an adsorbed species, most likely I 2 , blocked surface sites and significantly decreased current densities at high potentials. This study shows the NaI-AlBr 3 system offers an attractive, low-temperature molten salt electrolyte that could be useful to many applied systems, though composition and electrode material must be considered.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Background studies for NaI(Tl) detectors in the ANAIS dark matter project

Several large NaI(Tl) detectors, produced by different companies, have been operated in the Canfranc Underground Laboratory (LSC) in the frame of the ANAIS (Annual modulation with NaI Scintillators) project devoted to the direct detection of dark matter. A complete background model has been developed for a 9.6 kg detector (referred as ANAIS-0 prototype) after a long data taking at LSC. Activities from the natural chains of {sup 238}U and {sup 232}Th, and {sup 40}K in the NaI(Tl) crystal were evaluated applying different methods: discrimination of alpha particles vs beta/gamma background by Pulse Shape Analysis for quantifying the content of the natural chains and coincidence techniques for {sup 40}K. Radioactive contaminations in the detector and shielding components were also determined by HPGe spectrometry. Monte Carlo simulations using Geant4 package were carried out to evaluate their contribution. At high energies, most of the measured background is nicely reproduced; at low energy some non-explained components are still present, although some plausible background sources have been analyzed. The {sup 40}K content of the NaI(Tl) crystal has been confirmed to be the dominant contributor to the measured background with this detector. In addition, preliminary results of the background characterization, presently underway at the LSC, of two recently produced NaI(Tl) detectors, with 12.5 kg mass each, will be presented: cosmogenic induced activity has been clearly observed and is being quantified, and {sup 40}K activity at a level ten times lower than in ANAIS-0 has been determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of CeBr3 with LaBr3:Ce, LaCl3:Ce, and NaI:Tl Detectors

Energy resolution and detection efficiency were compared between two sizes of cerium bromide (CeBr3) scintillators, three sizes of lanthanum bromide (LaBr3:Ce) scintillators, three sizes of sodium iodide (NaI:Tl) scintillators, and a lanthanum chloride (LaCl3:Ce) scintillator. Comparisons are made of key parameters such as energy resolution, detection efficiency, linearity, and self-activity of CeBr3, LaBr3:Ce, LaCl3:Ce, and NaI:Tl scintillator detectors. The scintillator detectors are tested by comparing the peak separation and identification in the energy range up to 3.0 MeV using 133Ba, 152Eu, and naturally occurring radioactive materials [1]. The study has shown that CeBr3 scintillator detectors provided by Saint-Gobain offer better resolution than NaI:Tl scintillator detectors. CeBr3 detectors could resolve some closely spaced peaks from 133Ba and 152Eu, which NaI:Tl could not. LaBr3:Ce has slightly better resolution, and a slightly higher efficiency than CeBr3. In this work, “self-activity” of each of these four detector types was measured by operating the detectors themselves. A comparison of the intrinsic activity for all of the detectors in this study is demonstrated. For CeBr3, the self-activity present may be reduced, or even eliminated in the future, through improved processes for growing the material. It will be discussed if, and under what conditions, CeBr3 may be better than LaBr3:Ce and LaCl3:Ce for detection of certain special nuclear material γ-rays [2]. An overall advantage of CeBr3 detectors over lanthanum halide and NaI:Tl detectors will be discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

NaI (Tl) calorimeter calibration and simulation for Coulomb sum rule experiment in Hall-A at Jefferson Lab

A precision measurment of inclusive electron scattering cross sections is carried out at Jefferson Lab in the quasi-elastic region for 4 He, 12 C, 56 Fe and 208 Pb targets. The longitudinal (R L ) and transverse (R T ) response functions of the nucleon need to be extracted precisely in the momentum transfer range 0.55 GeV/c ≤ |q| ≤ 1.0 GeV/c. To achieve the above goal, a NaI (Tl) calorimeter is used to distinguish good electrons from background, including pions and low energy electrons rescattered from the walls of the spectrometer magnets. Due to a large set of kinematics and changes in HV settings, a number of calibrations are performed for the NaI (Tl) detector. Corrections for a few blocks of NaI (Tl) with bad or no signal are applied. The resolution of the NaI (Tl) detector after calibration reached ɤE/√E ≈ 3% at E = 1 GeV. The performance of the NaI (Tl) detector is compared with a simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Digital pulse processing for NaI(Tl) detectors

We apply two different post-processing techniques to digital pulses induced by photons in a NaI(Tl) detector and compare the obtained energy resolution to the standard analog approach. Our digital acquisition approach is performed using a single-stage acquisition with a fast digitizer. Both the post-processing techniques we propose rely on signal integration. In the first, the pulse integral is calculated by directly numerically integrating the pulse digital samples, while in the second the pulse integral is estimated by a model-based fitting of the pulse. Our study used a 7.62 cm×7.62 cm cylindrical NaI(Tl) detector that gave a 7.60% energy resolution (at 662 keV), using the standard analog acquisition approach, based on a pulse shaping amplifier. The new direct numerical integration yielded a 6.52% energy resolution. The fitting approach yielded a 6.55% energy resolution, and, although computationally heavier than numerical integration, is preferable when only the early samples of the pulse are available. We also evaluated the timing performance of a fast–slow detection system, encompassing an EJ-309 and a NaI(Tl) scintillator. Here, we use two techniques to determine the pulse start time: constant fraction discrimination (CFD) and adaptive noise threshold timing (ANT), for both the analog and digital acquisition approach. With the analog acquisition approach, we found a system time resolution of 5.8 ns and 7.3 ns, using the constant fraction discrimination and adaptive noise threshold timing, respectively. With the digital acquisition approach, a time resolution of 1.2 ns was achieved using the ANT method and 3.3 ns using CFD at 50% of the maximum, to select the pulse start time. Finally, the proposed direct digital readout and post-processing techniques can improve the application of NaI(Tl) detectors, traditionally considered ‘slow’, for fast counting and correlation measurements, while maintaining a good measurement of the energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a new rectangular NaI(Tl) scintillator and spectroscopy of low-energy charged particles

Standard NaI(Tl) scintillators have only one optical window and are housed in airtight protective enclosures to protect against hygroscopicity from moisture in the air. For these reasons, NaI(Tl) scintillators are unsuitable for the collection of scintillation photons or for the detection of low-energy (<1 MeV) charged particles. To overcome these disadvantages, a rectangular NaI(Tl) scintillator has been newly developed. In this paper, we estimate the photon response of this new scintillator. The energy resolution was {Delta}E (Full Width at Half Maximum)=7.5{+-}0.2% for 662 keV gamma rays from a {sup 137}Cs standard source. The number of photoelectrons was 3,686 for the photoelectric peak. Good energy resolution and photon collection were therefore confirmed for this specialized form of NaI(Tl) scintillator. The ability of this scintillator to detect low-energy particles was confirmed by successful measurement of low-energy charged particles (250-700 keV region) from a {sup 137}Cs thin film radioisotope source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and relevance of cosmogenic radionuclides in NaI(Tl) crystals

The cosmogenic production of long-lived radioactive isotopes in materials is an hazard for experiments demanding ultra-low background conditions. Although NaI(Tl) scintillators have been used in this context for a long time, very few activation data were available. We present results from two 12.5 kg NaI(Tl) detectors, developed within the ANAIS project and installed at the Canfranc Underground Laboratory. The prompt data taking starting made possible a reliable quantification of production of some I, Te and Na isotopes with half-lives larger than ten days. Tnitial activities underground were measured and then production rates at sea level were estimated following the history of detectors; a comparison of these rates with calculations using typical cosmic neutron flux at sea level and a selected description of excitation functions was also carried out. After including the contribution from the identified cosmogenic products in the detector background model, we found that the presence of {sup 3}H in the crystal bulk would help to fit much better our background model and experimental data. We have analyzed the cosmogenic production of {sup 3}H in NaI, and although precise quantification has not been attempted, we can conclude that it could imply a very relevant contribution to the total background below 15 ke in NaI detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Serrated flow in $\mathrm{NaI:Tl}$ scintillator crystals

We report the serrated-flow behavior is an important phenomenon that unveils material-deformation mechanisms, as reported for various kinds of materials. NaI doped with Tl (NaI:Tl) is unique among scintillation materials in that the structure contains glide planes that are linked to serration behavior. In the present work, single crystals of NaI:Tl were subjected to room-temperature compression experiments at different strain rates. The serrated flow was observed, and complexity and multifractal analyses were performed to analyze the serration behavior. The findings revealed that the strain rate had a pronounced effect on the complexity and multifractality of the serrated flow, similar to what has been found in other alloy systems. The results also indicate that there may be a strong link between the complexity of the serrated flow behavior and the heterogeneity of the underlying dynamics. It is expected that the present work could be a step toward a better understanding of the deformation behavior and forgeability of NaI:Tl single crystals.

36 MATERIALS SCIENCE↗

Luminescence and radiation resistance of undoped NaI crystals

Highlights: • The performance of NaI scintillators depends on luminescence properties. • A criterion of crystals’ purity level is radiation colorability at room temperature. • The traces of the most dangerous impurities were detected. • Crucial role in efficiency of pure NaI scintillator play the crystal perfection. - Abstract: Undoped NaI single crystal is an excellent scintillator at low temperature. However, scintillation parameters of different quality crystals vary in a wide range, significantly exceeding measurement error. Experimental data demonstrate the features of luminescence, radiation induced coloration, and afterglow dependence on the quality of nominally pure crystals. It is found that defects level that allows to elucidate artefacts introduced by traces of harmful impurities corresponds to 3 × 10{sup 15} cm{sup −3} that significantly overhead accuracy of chemical and absorption analysis. It is shown that special raw material treatment before and during the single crystal growth allows to reach NaI purity level that avoids impurities influence to the basic luminescence data.

36 MATERIALS SCIENCE↗

Two Flavoenzymes Catalyze the Post-Translational Generation of 5-Chlorotryptophan and 2-Aminovinyl-Cysteine during NAI-107 Biosynthesis

Lantibiotics are ribosomally synthesized and post-translationally modified antimicrobial peptides containing thioether rings. In addition to these cross-links, the clinical candidate lantibiotic NAI-107 also possesses a C-terminal S-[(Z)-2-aminovinyl]-d-cysteine (AviCys) and a unique 5-chloro-l-tryptophan (ClTrp) moiety linked to its potent bioactivity. Bioinformatic and genetic analyses on the NAI-107 biosynthetic gene cluster identified mibH and mibD as genes encoding flavoenzymes responsible for the formation of ClTrp and AviCys, respectively. The biochemical basis for the installation of these modifications on NAI-107 and the substrate specificity of either enzyme is currently unknown. Using a combination of mass spectrometry, liquid chromatography, and bioinformatic analyses, we demonstrate that MibD is an FAD-dependent Cys decarboxylase and that MibH is an FADH2-dependent Trp halogenase. Most FADH 2 -dependent Trp halogenases halogenate free Trp, but MibH was only active when Trp was embedded within its cognate peptide substrate deschloro NAI-107. Furthermore, structural comparison of the 1.88-Å resolution crystal structure of MibH with other flavin-dependent Trp halogenases revealed that subtle amino acid differences within the MibH substrate binding site generates a solvent exposed crevice presumably involved in determining the substrate specificity of this unusual peptide halogenase.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Characterization of a Sodium Iodide (NaI) Array for Coincidence Measurements

An array of sodium iodide detectors (NaI) was constructed to record time-correlated gamma ray measurements. The NaI Array consists of twelve 2×4×16-inch detectors. When the array is placed close to an inspected object, this arrangement provides high efficiency for gamma ray detection, particularly for high-energy gamma rays. Data are collected in time-tagged, list-mode format, which is suitable for the application of a variety of coincidence analysis methods. Automated energy calibration of each detector is accomplished by utilizing gamma radiation from thoriated welding rods that are embedded in the system. The energy resolution of spectra that are produced by the NaI array is 7.3% at 662 keV. The data are processed to sum gamma-ray energies for simultaneous detections in adjacent detectors, which are dominated by the escape of scattered photons from one detector and subsequent absorption in an adjacent detector. When data are processed in this way, the photopeak efficiency exceeds 20% over the range 400 keV to 10 MeV; the total efficiency, which includes the Compton continuum and single and double escape peaks, exceeds 70% over this energy range. Utilization of time correlations enables isolation of spectral features that are associated with the same decay cascade or fission event. Characterization of the response of the NaI Array to both gamma rays and neutrons with the Gamma Detector Response and Analysis Software (GADRAS) enables accurate computation for virtually any radiation sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atmospheric {sup 41}Ar Plume Tracking of the UF Training Reactor Using a Large-Volume NaI Detector

The ability to track and monitor gaseous radioactive materials is important in the event of a radioactive release such as from a nuclear power plant accident, weapons testing, or other unintended release scenarios. The International Monitoring System (IMS) is currently in place to monitor for weapons testing and has been used to monitor nuclear power plant accidents. However, only 80 radionuclide stations for the IMS exist in the world and are stationary, limiting the resolution of any radioactive plumes detected. Furthermore, the IMS radionuclide stations are designed to be sensitive specifically to atmospheric radio-xenon and no other radionuclides. Historically, monitoring radioactive releases has been limited to the detection of radio-xenon and radio-krypton, both arising as fission products from nuclear fuel. After the accident at Three Mile Island Unit 2, scientists were interested in finding the dose the public received from released radioactive material. This was achieved by analyzing radiation monitors in the exhaust stack and filters within the reactor building. furthermore, a series of 20 thermoluminescent dosimeters (TLD's), 8 air sampling station positioned around Three Mile Island, and a helicopter survey which used a NaI(Tl) detector array provided data on radionuclides, specifically {sup 137}Cs, that escaped the confines of the reactor building. The TLD's and air sampling stations were stationary, and therefore limited the resolution of the radioactive release plume. The helicopter survey using the NaI detectors was limited by the technology available at the time. The NaI detector array output was compressed from 1024 channels to 256 channels, limiting the energy resolution of the spectral data. The helicopter used a microwave ranging system to establish position. Since this survey was taken in October of 1982, advancements in technology allow spectral data to be saved in its full 1024 channel format and the advent of GPS can give a more accurate account of the detector position. An updated mobile system for tracking a radioactive release would help to alleviate these issues as well as gain the ability to track a radioactive release in real-time. We investigate the feasibility of mobile tracking through study and measurement of the {sup 41}Ar plume released from the University of Florida Training Reactor (UFTR) research reactor. We use a large-volume NaI(Tl) detector placed on the roof near the reactor. This detector may also be placed and moved on a cart to survey the area surrounding the reactor. We compare the spectral data taken when the reactor is running at full power to the background to analyze the effectiveness of the detector at identifying atmospheric {sup 41}Ar. Finally we discuss the implications of these measurements with regards to validation of plume models and the capability to track releases over a localized area from the source. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spectral Multi-peak Analysis Methodology for Eliminating Effects of NaI Temperature Drift

This paper presents a methodology of spectral multi-peak analysis for eliminating temperature drift effects of NaI scintillation gamma-ray detectors. Properties and cost of NaI make it an excellent choice for low energy (< 1-MeV) spectroscopic studies. However, the light output of NaI scintillators has high temperature dependence, and the common practice of selecting a region of interest (ROI) for the peak of study in the measured spectrum requires that NaI temperature drift be monitored and corrected, typically by gain control of the measurement electronics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The nonlinear light output of NaI(Tl) detectors in the Modular Total Absorption Spectrometer

New detector array, the Modular Total Absorption Spectrometer (MTAS),was commissioned at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab(ORNL).Total absorption gamma spectra measured with MTAS are expected to improve beta-feeding patterns and beta strength functions in fission products.MTAS is constructed out of hexagonal NaI(Tl) detectors with a unique central module surrounded by 18 identical crystals assembled in three rings. The total NaI(Tl) mass of MTAS is over1000 kg.The response of the central and other 18 MTAS modules to -radiation was simulated using the GEANT4 tool kit modified to analyze the nonlinear light output of NaI(Tl).A detailed description oftheGEANT4modifications madeisdiscussed.SimulatedenergyresolutionofMTAS modules is found to agree well with the measurements for single transitions of 662keV (137Cs) with 8.2% full width half maximum (FWHM),835keV (54Mn) with FWHM of 7.5% FWHM, and 1115keV (65Zn) with FWHM of 6.5%.Simulations of single and multiple -rays from 60Co are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗