Search NASA⌕ Search

SEARCH · Search NASA

Results for “Offner spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Optical Design and Performance of the Ultra-Compact Imaging Spectrometer

We present the optical design and performance of the Ultra-Compact Imaging Spectrometer (UCIS) currently under development at Caltech's Jet Propulsion Laboratory. The new instrument demonstrates a low optical bench mass of less than 0.5 kg and compact size that enables Mars Rover or other in situ planetary applications. UCIS is a F/4, wide field (30deg) design, covering the spectral range 500-2600 nm and is enabled by a simple all aluminum two-mirror telescope and Offner spectrometer. We discuss here the optical design and alignment method that enables this compact and low mass imaging spectrometer and demonstrate successful spectrometer alignment with smile and keystone levels at 2-3% of a pixel width.

Imaging spectroscopy↗

Thermal Design of the Thermal Infrared Spectrometer (TIRS) Instrument on PREFIRE

The Polar Radiant Energy in the Far-Infrared Experiment (PREFIRE) consists of two 6U CubeSats that each host a Thermal Infrared Spectrometer (TIRS) instrument. The CubeSats are scheduled for launch in March and October of 2023. The purpose of the TIRS instrument is to make spectrally resolved measurements of the Earth’s thermal radiation from the top of the atmosphere. PREFIRE will document, for the first time, variability in spectral fluxes from 4 to 54 microns on hourly to seasonal timescales. The primary mission is 12 months in a polar orbit with inclination of 82 to 98 at altitudes between 450 km and 650 km. The TIRS instrument is an Offner spectrometer that uses a thermopile detector array and a Schwarzchild telescope. In addition, there is a scan mirror which is periodically actuated for calibration. The instrument concept of operation is to collect radiation emitted towards zenith in a nadir sounding orientation with periodic internal and space calibrations. The TIRS thermal control architecture consists of entirely passive elements. The instrument requires all elements be maintained between 0 C and 50 C during operation for the duration of the mission. An overview of the overall thermal control design approach is presented.

Andrade, Andres↗

Instrumentation and First Results of the Reflected Solar Demonstration System for the Climate Absolute Radiance and Refractivity Observatory

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission key goals include enabling observation of high accuracy long-term climate change trends, use of these observations to test and improve climate forecasts, and calibration of operational and research sensors. The spaceborne instrument suites include a reflected solar spectroradiometer, emitted infrared spectroradiometer, and radio occultation receivers. The requirement for the RS instrument is that derived reflectance must be traceable to Sl standards with an absolute uncertainty of <0.3% and the error budget that achieves this requirement is described in previo1L5 work. This work describes the Solar/Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS), a calibration demonstration system for RS instrument, and presents initial calibration and characterization methods and results. SOLARIS is an Offner spectrometer with two separate focal planes each with its own entrance aperture and grating covering spectral ranges of 320-640, 600-2300 nm over a full field-of-view of 10 degrees with 0.27 milliradian sampling. Results from laboratory measurements including use of integrating spheres, transfer radiometers and spectral standards combined with field-based solar and lunar acquisitions are presented. These results will be used to assess the accuracy and repeatability of the radiometric and spectral characteristics of SOLARIS, which will be presented against the sensor-level requirements addressed in the CLARREO RS instrument error budget.

McCorkel, Joel↗

Design of a grating spectrometer from a 1:1 Offner mirror system

A 1:1 Offner mirror system is modified to work as a grating spectrometer for the infrared by placing a grating on the secondary convex mirror of the system. Slight adjustment of the configuration combined with tilt of the secondary provide the necessary degrees of freedom to correct for astigmatism of the system. Additional control may be obtained by using a holographic optical element (HOE), constructed to add necessary compensating aberrations. Details of the best configuration and the limitations of performance are presented.

Kwo, Deborah↗

UV Capabilities of the CETUS Multi-Object Spectrometer (MOS) and NUV/FUV Camera

The Cosmic Evolution Through UV Spectroscopy (CETUS) concept enables parallel observations by the UV multiobject spectrometer (MOS) and near-UV/far-UV camera which operate simultaneously but independently with their separate field of views. The near-UV MOS can target up to 100 objects at a time without confusion with nearby sources or background zodiacal light. This multiplexing will allow over 100,000 galaxies to be observed over a typical mission lifetime. The MOS includes a next-generation micro-shutter array (NGMSA), an efficient aspheric Offner-like spectrometer design with a convex grating, and nanotube light traps for suppressing unwanted wavelengths. The NUV/FUV Camera has the capability to image in a range of sub-bands from 115-400 nm at the same time the MOS is operating at 180-350 nm. The UV camera has a similar Offner-like relay, selectable filters, and two separate detectors to optimize observing in either the far-UV (115-175 nm) or the near-UV (180-400 nm) utilizing a CsI Micro-Channel Plate detector (MCP) and a CCD respectively.

The Cosmic Evolution Through UV Spectroscopy (CETU↗

Alignment and Characterization of High Uniformity Imaging Spectrometers

Imaging spectrometers require precise adjustments, in some cases at the sub-micrometer level, in order to achieve auniform response over both the spectral and spatial dimensions. We describe a set of measurement techniques and theircorresponding alignment adjustments to achieve the 95% or higher uniformity specifications required for Earthobservingimaging spectrometers. The methods are illustrated with measurements from the Next Generation Imaging Spectrometer system that has been built at the Jet Propulsion Laboratory, California Institute of Technology, under contract with the National Aeronautics and Space Administration.

Offner spectrometer↗

Field Calibration Techniques used to Characterize the Radiometric Stability of the GEO-CAPE Airborne Simulator (GCAS)

The GEOstationary Coastal and Air Pollution Events (GEO-CAPE) Airborne Simulator (GCAS) was developed at NASA’s Goddard Space Flight Center (GSFC) and has flown in multiple field campaigns to perform mapping of the regional-scale EPA criteria pollutants nitrogen dioxide, ozone, and formaldehyde. GCAS will also participate invalidation campaigns for NASA’s Tropospheric Emissions: Monitoring POllution (TEMPO) mission and the Korean Geostationary Environment Monitoring Spectrometer (GEMS) mission, both scheduled to launch in the early 2020s. GCAS houses two commercial Offner-type grating spectrometers that measure backscattered solar spectral radiance from the near-ultraviolet to near-infrared at high spatial resolution (typically 250 meters at 8.5 kilometer altitude). These radiances are used to retrieve spatial and temporal distributions of trace gases relevant to the boundary layer and free tropospheric atmospheric chemistry cycles. In this paper, we describe the field calibration techniques employed to characterize the spectral and temporal radiometric stability of the system during its most recent deployment in the 2018 Long Island Sound Trace Ozone Study (LISTOS) field campaign. Overall measurement uncertainty, retrieval impacts, and lessons learned for future deployments will also be described.

NASA’s Tropospheric Emissions: Monitoring POllutio↗

Convex Diffraction Grating Imaging Spectrometer

A 1:1 Offner mirror system for imaging off-axis objects is modified by replacing a concave spherical primary mirror that is concentric with a convex secondary mirror with two concave spherical mirrors M1 and M2 of the same or different radii positioned with their respective distances d1 and d2 from a concentric convex spherical diffraction grating having its grooves parallel to the entrance slit of the spectrometer which replaces the convex secondary mirror. By adjusting their distances d1 and d2 and their respective angles of reflection alpha and beta, defined as the respective angles between their incident and reflected rays, all aberrations are corrected without the need to increase the spectrometer size for a given entrance slit size to reduce astigmatism, thus allowing the imaging spectrometer volume to be less for a given application than would be possible with conventional imaging spectrometers and still give excellent spatial and spectral imaging of the slit image spectra over the focal plane.

Chrisp, Michael P.↗

Compact Infrared Spectrometers

Concentric spectrometer forms are advantageous for constructing a variety of systems spanning the entire visible to infrared range. Spectrometer examples are given, including broadband or high resolution forms. Some issues associated with the Dyson catadioptric type are also discussed.

imaging spectroscopy↗